Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BELLO II PO PS KIMIN PAPUMPARE ARUNACHAL PRADESH PIN 791121 | PAPUM PARE | ARUNACHAL PRADESH | 791121 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 04 SUDARSHNA COOLING CENTRE ADP ROAD CHRISTIANPATTY NAGAON ASSAM 782001 | NAGAON | ASSAM | 782001 | Admitted-Finance |
Tender Value
₹12.6 L
EMD Value
₹25,200
Closing Date
21 Mar 2020, 3:00 pmClosed
AGM(EM)
AGM(EM), FCI, RO, Guwahati
ARMO work to internal and external electrical installation at FSD North Lakhimpur
2020_FCI_549232_1
06/2019-20
Open Tender
Repair and Maintenance Services
Works
60 days
Lakhimpur
Please refer Tender documents.
12 documents required · 12 mandatory
₹590
FCI
₹25,200
28 Apr 2020
3 Mar 2020
23 Mar 2020
3 Mar 2020
21 Mar 2020
3 Mar 2020
Amount
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
3 x 1.5 sq. mm
6 x 1.5 sq. mm
9 x 1.5 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Supplying and fixing 6 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required of make C&S/STANDARD/HAVELLS/LeGrand. (But without MCB/RCCB/Isolator)
Supplying and fixing 63 A TP&N MCB inside the existing panel board including deilling holes in panel, Mking connections etc as required (Havells Cat No. ) (Make Havells, Legrand, Schnider, L&T)
Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. of make HAVELLS/STANDARD
Single pole
Single Pole & neutral
Supplying and fixing 5/6 amps switch make Havells/Anchor piano type/tumbler switch/ socket on the existing switch box/ cover including connections etc. as required.
Replacement of the existing unserviceable phenolic laminated sheet 3 mm thick i/c cutting. Drilling and fixing of piano type switch/socket i/c interconnections etc. as reqd.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
3 Module (100mmX75mm)
Supplying and fixing of 1200 mm sweep capacitor type A.C ceiling fan complete with 30 cm down rod with hanging shackle , blade canopy suitable for 230/240 volt, 50 cycles/sec., single phase supply conforming to ISI-374/1966 of make Bajaj/ Crompton cat No. GRACE GOLD/HILL BREEZE as amended from time to time.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply of following type of XLPE POWER CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 of make POLYCAB/HAVELLS/MESCAB as required.
CABLE SIZE 3.5 X 35 SQ.MM
CABLE SIZE 3.5 X 25 SQ.MM
CABLE SIZE 2 X 10 SQ.MM
Laying of one No. PVC insulated & PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
upto 35 sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade up to 35 sq.mm in the existing RCC/ HUME/ METAL pipe as required.
Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE al conductor cable of 1.1KV grade Upto 35 sq. mm (clamped with 1mm thick saddle) on the wall surface as reqd.
Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required.
S/I/T/C of 18W LED tube light fitting of make Bajaj/Crompton/Philips catalog no. BLRB-DB 118 Bajaj including all accessories i.e., installation of Led tube on wall/truss with round block, screw etc as required.
Supply of LED tube and batten, 2x18 W LED lamp to be directly fitted in the luminaire BLRB-DB 218 Bajaj make or equivelant make of Phillips/Havells complete with two NOs LED tube rod of make Bajaj/Crompton/Phillips make .
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent/LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of LED street light fitting of 72 watts, AC 240 volts of Bajaj make cat no. BRLEP 72W LED V2 of Pressure die cast Al. housing or its equiavlent of make HPL/Philips/Crompton complete with all accessories etc.
Supply of LED street light fitting of 45 watts, AC 240 volts of make Bajaj catalog no. 45W BRTFG LED V2 of Pressure die cast Al. housing or its equiavlent of make HPL/Philips complete with all accessories etc
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
I/T/C of prewired street light fittings complete with all accessories on the existing G.I. pipe bracket on pole /wall including wiring & connections as required.
P/F of cable termination of M.S. box of size 15cm X 15cm X 10 cm with compression termination arrangements, 6-10 Amp SP MCB and double natural link etc as required.
Less credit for dismantaled old damaged steel conduit and scrap
Less credit for dismantaled old damaged 8 way MCB DB
Less credit for dismantaled old damaged 4+12 way MCB DB
Less credit for dismantaled old damaged Single pole MCB 6 to 32 Amp
Less credit for dismantaled old damaged 5/6Amp piano type switch
Less credit for dismantaled old damaged phenolic sheet and scrap
Less credit for dismantaled old damaged 150 W HPSV Fitting
Less credit for dismantaled old damaged Flourescent fitting
Less credit for unservisable box type flourescent fitting and scrap
Less credit for dismantaled old damaged cable termination M.S box and scrap
HALOI TRADERS
M/s Indra Construction
AKIN ENTERPRISE
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .