| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L1 | Accepted-AOC Acceptance of Contract | |
| 2 | L2₹38.4 L+₹3.5 L (10.1%)Rejected-Finance CHHANI NANAK TEHSIL MANDAL PHALLAIN JAMMU J K 180003 | JAMMU | JAMMU | J K | 180003 | L2 | Rejected-Finance R | |
| 3 | L3₹38.6 L+₹3.7 L (10.6%)Rejected-Finance | L3 | Rejected-Finance R | |
| 4 | L4₹39.7 L+₹4.8 L (13.6%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L4 | Rejected-Finance R | |
| 5 | Rejected-Technical INDEX NO E 108 HQ CWE NO 2 DELHI CANTT J 636 SECTOR 23 SANJAY NAGAR GHAZIABAD UTTAR PRADESH 201002 | GHAZIABAD | UTTAR PRADESH | 201002 | - | Rejected-Technical No in WLR for QE Apr 2022 of GE IMA |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA DEHRADUN
GE IMA DEHRADUN
REPAIR AND MAINTENANCE OF GEYSERS AND CEILLING FAN
2022_MES_515383_1
GE/IMA/19/2022-23 9196/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA DEHRADUN
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA DEHRADUN
₹90,000
Yes
14 Jun 2022
26 Mar 2022
27 Apr 2022
28 Mar 2022
25 Apr 2022
11 Apr 2022
60 days
Amount
Taking down Ceiling fan 1200 to 1400 mm sweep of any make and set aside in safe custody for rewinding at local workshop and fixing the same complete all as specified and directed.
Taking down exhaust fan/cabin fan/ wall mounted fan of any sweep and set aside in safe custody for rewinding at local workshop and fixing the same complete all as specified and directed
M&L for Rewinding of ceiling fan of any make with super enameled copper wire of same size including necessary varnishing of new winded coil insulation etc complete all as specified and directed of following sweeps:-
1200 mm sweep ceiling fan
1400 mm sweep ceiling fan
M&L for Re-winding of exhaust fan of any make with super enameled copper wire of same gauge as original including necessary varnishing to new winding coil insulation packing, overhauling, cleaning, greasing, reassembling and testing complete all as specified and directedfor the following sizes:-
250 to 300 mm sweep
350mm to 450 mm sweep
600 mm sweep
M&L for Re-winding of cabin fan/table fan upto 450mm sweep of any make with super enameled copper wire of same gauge as original including necessary varnishing to new winding coil insulation packing, overhauling, cleaning, greasing, reassembling and testing complete all as specified and directed
S&F Gun metal bushes as per sample fixed in repair complete all as specified and directed
S&F Capacitor 2.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as specified and directed.
S&F Capacitor 3.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as specified and directed.
S&F Capacitor 04 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as specified and directed.
S&F Capacitor 1/1.5 mfd 230 volt AC 50 HZ suitable for ceiling fan/ exhaust/cabin/table fan of any sweep fixed in repair complete all as specified and directed.
S&F Ball bearings of ceiling fan of any sweep fixed in repair complete all as specified and directed of following sizes:-
Ball bearing No 6201
Ball bearing No 6202
Ball bearing No 6203
Ball bearing No 6204
S&F Ball bearing of suitable size of exhaust fan 250 to 450mm sweep fixed in repair complete all as directed.
S&F Ball bearing of suitable size of wall mounted fan 600mm sweep fixed in repair complete all as specified and directed.
S&F Taking down and Preparation of old painted body and blades of ceiling fan 1200 mm to 1400 mm sweep, cleaning foreign material, filling cavities etc and painting with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging complete all as specified and directed.
S&F Taking down and Preparation of old painted body and blades of exhaust fan 300 mm to 450 mm sweep, cleaning foreign material, filling cavities etc and painting with one coat of synthetic enameled paint by spray painting and marking MES No with paint and hanging complete all as specified and directed
S&F Reel insulator of hard rubber of suitable size for ceiling fan fixed in repair complete all as specified and directed
S&F PVC canopy of the ceiling fan with screw of any size fixed in repair complete all as specified and directed
S&F Down rod clamp in one piece or two piece with split pin, bolt , nut and washer as per sample fixed in repair complete all as specified and directed
S&F Fan regulator electronic 100 watts, 5 step type 230 volts AC fixed in repair complete all as specified and directed.
Lite dimmer type 1000 watt. Make:- Legrend Cat Part No 572740 or equivalent of Havels/ Anchor/Bajaj/Crompton/Usha
S&F Fan regulator modular type, electronic 120 watts, step type, 230 volts as per sample complete fixed in repair complete all as specified and directed.
S&F Nuts, bolts and washer set, 10mm dia, 75 mm long as per sample fixed in repair complete all as specified and directed
S&F Down rod of rigid steel cunduit of 15mm dia 60cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as specified and directed
S&F Down rod of rigid steel cunduit of 15mm dia 90cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as specified and directed
S&F Down rod of rigid steel cunduit of 15mm dia 120cm long for hanging fan with two cut in end of one side pipe approx length 1/2" to 2" and two holes for entering flexible cable both side fixed in repair complete all as specified and directed
S&F MS clamps with 40mmx4mm thick flat iron bent to shape any type having center two holes, nuts & bolts for hanging light fittings complete fixed in repair complete all as specified and directed
S&F Exhaust fan blade metal/plastic set suitable for 250 to 300mm sweep as per sample fixed in repair complete all as specified and directed
S&F Exhaust fan/wall mounted fan blade metalic set suitable for 450/600mm sweep as per sample fixed in repair complete all as specified and directed
S&F Taking down ceiling fan and overhauling/servicing, cleaning, greasing, reassembling, hanging and testing of ceiling fan of any sweep 1200mm to 1400mm including cleaning and greasing material complete all as specified and directed
S&F Taking down exhaust fan and overhauling/servicing, cleaning, greasing, reassembling and testing of Exhaust fans/wall mounted fans of any sweep (i.e. 250mm to 600mm) including cleaning and greasing/replacing any worn out part complete all as specified and directed. Note :- (i) For servicing purpose Machine oil/grease should be used of apprpriate make only duly passed by the Engineer - in-Charge. (ii) replacement of any worn out part like bearing/ bush/shaft will measured & paid separately)
S&F Split pin of suitable size fixed on nuts & bolts complete all as specified and directed
S&F Louvers for exhaust fan of 300mm sweep fixed in repair on wall complete all as specified and directed
S&F Louvers for exhaust fan of 450mm sweep fixed in repair on wall complete all as specified and directed
S&F Blade screws of suitable size or as per site requirement complete with washer complete all as specified and directed
S&F Metal ceiling fan blade suitable for 1200 to 1400 mm sweep as per sample fixed in repair complete all as specified and directed
S&F Shaft suitable for ceiling fan of any type/size as per sample complete fixed in repair complete all as specified and directed
S&F Sheet metal enclosure, triple pole and neutral with three pin and earth plug and socket with and including one single pole MCB 20. Amps, 240 volts,10 KA complete fixed in repair complete all as specified and directed.
Supply and fix in replacement of ceiling fan 1200 mm sweep, 230 volts 5h Hz, energy saving model single phase, copper wound motor, five star, pearl white in colour complete with blade, down rod , canopy and connected with ceiling rose etc complete all as specified and directed.
Supply and fix in replacement of ceiling fan 1400 mm sweep, 230 volts 5h Hz, energy saving model single phase, copper wound motor, five star, pearl white in colour complete with blade, down rod , canopy and connected with ceiling rose etc complete all as specified and directed.
Supply and fix in replacement of metal body exhaust fan 300 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Turbojet SP of Havells and equivalent of Bajaj/Usha.
Supply and fix in replacement of metal body exhaust fan 450 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Turbojet SP of Havells and equivalent of Bajaj/Usha.
Supply and fix in replacement of metal body exhaust fan 600 mm sweep, 900 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Turbojet SP of Havells and equivalent of Bajaj/Usha.
Supply and fix in replacement of plastic body exhaust fan 300 mm sweep, 1000 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Model No-Maxima DX 5 blade of Bajaj and equivalent of Havells/Usha.
Supply and fix in replacement of plastic body exhaust fan 200 mm sweep, 1000 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Model No-Maxima DX 5 blade of Bajaj and equivalent of Havells/Usha.
Supply and fix in replacement of plastic body exhaust fan 250 mm sweep, 1000 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Model No-Maxima DX 5 blade of Bajaj and equivalent of Havells/Usha.
Taking down unserviceable heating Element gas chullah of any size/capacity and S&F heating element 3KW 230 volts tria flange with check nut 40 mm dia as per sample suitable for baine marry complete all as specified and directed
Taking down unserviceable heating Element gas chullah of any size/capacity and S&F heating element 5KW 230 volts tri flange with check nut 40 mm dia as per sample suitable for baine marry complete all as specified and directed
Taking down unserviceable thermostate any size and S&F thermostate thermal cut out single phase 240 volts as per sample suitable for baine marry complete all as specified and directed
Taking down unserviceable cutting blade any size and S&F cutting blade for bread cutting machine approximate length 30 to 35 cm as per samplecomplete all as specified and directed
Taking down unserviceable copper pipe 8mm dia and S&F copper pipe 8mm dia suitable for cooking range as per sample complete all as specified and directed.
Taking out existing defective starting capacitor and S&F, starting capacitor 8-30 MFD as per sample complete all as specified and directed.
Taking out existing defective starting capacitor and S&F, starting capacitor 30-50 MFD as per sample complete all as specified and directed.
Taking down unserviceable thermostat and S & F thermostat cut out 3 phase 415 volts suitable for dishwashing machine complete all as specified and directed.
Taking down unserviceable B type burnor any size and S&F B type burner 2 to 3 inch dia ISI marked as per sample complete all as specified and directed.
Taking down unserviceable pilot burner any size and S&F pilot burner 5mm to 20mm dia ISI marked as per sample complete all as specified and directed.
Taking down unserviceable rubber castors and S&F rubber castors with ball bearing 6 to 8 inch, capacity 500 Kgs suitable for food service trolly complete all as specified and directed.
Taking down unserviceable fan belt and S&F fan belt suitable for exhaust system complete all as specified and directedof following size:-
Taking down unserviceable burner and S&F burner small size T-35 as per sample complete all as specified and directed.
Taking down unserviceable burner and S&F burner medium size T-35 as per sample complete all as specified and directed.
Taking down unserviceable burner and S&F burner big size G-8 as per sample complete all as specified and directed
Taking down unserviceable Chinese burner and S&F Chinese burner as per sample complete all as specified and directed
Taking down unserviceable LPG gas, regulator and S&F LPG gas high pressure regulator industrial screw type ISI marked complete all as specified and directed
Taking down unserviceable Rotary switch of gas burner and S&F rotary switch single phase 240 volts 3 step (pole) 32 amps as per sample complete all as specified and directed.
Taking down unserviceable LPG gas connection pipe and S&F LPG gas connection pipe ISI Marked fibre thread bedded industrial type including GI clip on both ends complete all as specified and directed
Disconnecting the electric connection opening cutting the burnt wire from motor and clean slots for rewinding with new copper wire of same size varnishing, drying complete and refixing in the original position complete all as specified and directed of following size of exhaust system of kitchen motor:-
1 HP motor single phase
2 HP motor single phase
7.5 HP motor 3 phase
10 HP motor 3 phase
S&F Ball bearing (FK-207) with cover for blower shaft suitable for exhaust system as per sample, complete fixed in repair all as specified and directed.
Servicing of wet grinder machines of capacity 5 ltr including Greasing & replacement of bearings, fan belts, nut bolts as per direction of Engineer-in-Charge complete all as specified and directed.
Servicing of wet grinder machines of capacity 15 ltr including Greasing & replacement of bearings, fan belts, nut bolts as per direction of Engineer-in-Charge complete all as specified and directed.
S&F Minor repair and servicing of electric driven single phase motor in Atta kneading machine and fixing rotating handle such as adjustment, and testing of capacity 2 HP motor, Greasing & replacement of bearings, fan belt, nut bolts if any required complete all as specified and directed.
S&F Servicing of mincing machine Greasing & replacement of bearings, fan belt, nut bolts as required and testing complete all as specified and directed
S&F Maintenance and servicing of potato pillar machine with weaving and fixing new surface in machine including, Greasing & replacement of bearings, fan belt, nut bolts as required and testing as directed.
S&F Servicing of Exhaust system & Fresh air system, cleaning of dust with suitbale chemical at both ends including oiling & greasing of motor and attending minor repairs as required complete all as specified and directed.
S&F Taking down air curtain for repair and servicing and refixing after repair / servicing at its original position complete all as specified and directed (Note- spare parts of air curtain shall be measured and paid saperately under respetive item)
M&L for Rewinding of air curtain blower motor 2 HP single phase with superenameled copper winding wire of existing guage complete all as specified and directed.
M&L for Supply only motor ball bearing with cover of blower shaft of existing size.
M&L for Supply only blower fan blades of existing size
M&L for Wall fans 230 Volts single phase oscillating 400 mm sweep suitable for wall mounting complete all as specified and directed. Make:- Havells, Model No. Platina HS or equivalent of Bajaj/Usha.
M&L for Pedestal fan 230 Volts single phase oscillating 400 mm sweep 3 blades with remote free standing complete all as specified and directed. Make:- Havells, Model No. Sprint LED remote or equivalent of Bajaj/Usha.
M&L for MCCB,63 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting including taking out existing unserviceable MCCB complete all as specified and directed
M&L for MCCB,100 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting including taking out existing unserviceable MCCB complete all as specified and directed
M&L for MCCB,125 Amps, 4 pole, 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting including taking out existing unserviceable MCCB complete all as specified and directed
M&L for Taking down unserviceable storage type electric water heater (Geysers) after isolating electric supply of capacity 25/35 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as specified and as directed.
Taking down unserviceable storage type electric water heater (Geysers) after isolating electric supply of capacity 50 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as specified and as directed.
Taking down unsv storage type electric water heater (Geysers) any make after isolating electric supply capacity 100/150 litres from site for desclaing the inner container with cleaning solution including refixing in same position or where directed complete all as specified and as directed.
Taking down unserviceable storage type electric water heater (Geysers) from site of capacity 25/ 35/50 ltr for necessary repair of inner tank for water leakage and including with stainless steel welding and refixing in same position or as directed and testing complete all as specified and as directed.
M&L for Stainless steel inner container (tank) of capacity 25/35 litres and testing complete of make. Pearl, Ditz, Racold, Gilco, Sahas including taking down of old unserviceable tank complete all as directed.
M&L forStainless steel outer container for 25/35 litres tank capacity geyser and testing complete of make.Pearl, Ditz, Racold, Gilco, Sahas including taking down old unserviceable outer cover complete all as specified and as directed.
M&L for Stainless steel inner container (tank) of capacity 50 litres and testing complete of make. Pearl, Ditz, Racold, Gilco, Sahas including taking down old unserviceable tank complete all as specified and as directed.
M&L for Stainless steel outer container for 50 litres tank capacity geyser and testing complete of make.Pearl, Ditz, Racold, Gilco, Sahas including taking down old unserviceable outer cover complete all as specified and as directed.
M&L for Non return valves cast copper alloy 15 mm dia ISI mark complete including taking down old existing NRVcomplete all as specified and as directed..
Taking down old/unserviceable assembly of water heater of capacity 25/35 ltr & S&F new stainless steel chromium plated assembly ISI marked as per sample suitable for water heater of capacity 25/35 ltrs complete all as specified and as directed.
Taking down old/unserviceable assembly of water heater of capacity 50 ltr & S&F new stainless steel chromium plated assembly as per sample suitable for water heater of capacity 50 ltrs complete all as specified and as directed.
S&F Heating element 2 KW 230 volt, ISI marked, round /triangular type as per sample for storage type electric water heater including taking down existing unserviceable element complete all as specified and as directed.
S&F Heating element 2.0 KW 230 volt, ISI marked square/rectangular type as per sample for storage type electric water heater including taking down existing element complete all as directed.
S&F Heating element 1.5 KW 230 volt, ISI marked square/rectangular type as per sample for storage type electric water heater including taking down existing element complete all as directed.
Heating element 3 KW, 230 volts ISI markded Round shape base with provn of Thermostate Racold Model PL-150, ISI Marked including taking down existing element complete all as specified and as directed.
S&F Thermostat switch 220- 240 volt 16 Amp 0-75° /80° C ISI marked as per sample suitable for round including taking down existing complete all as specified and as directed.
S&F Thermostate switch 220- 240 volt 16 Amp 0-75° / 80° C ISI marked as per sample suitable for square/rectangular type of element including taking down existing complete all as specified and as directed.
S&F Indicating lamp 230 volt AC for geyser fixed in repair of Green & Red colourcomplete all as specified and as directed..
S&F Heavy duty PVC connection with 15mm dia 450mm long CP with brass nuts and leads PVC washer 02 Nos on each ends for geyser connection fixed in repair complete all as specified and as directed.
S&F Heavy duty PVC connection with 15mm dia 600mm long CP with brass nuts and leads PVC washer 02 Nos on each ends for geyser connection fixed in repair complete all as specified and as directed.
S&F Chromium Plated pipe connection with washer and bolt, size 15mm dia, 450mm long including taking down existing complete all as directed.
S&F Chromium Plated pipe connection with washer and bolt, size 15mm dia, 600mm long including taking down existing complete all as specified and as directed.
S&F Metal clad Industrial plug top ISI mark, 3 pin with earth, 230 to 250 Volts including taking down existing complete all as specified and as directed.
S&F PVC insulated copper cable size 3 core 70/.0076, AC 1100/660 volt including taking down existing unserviceable cable complete all as specified and as directed.
S&F PVC insulated copper cable size 2 core 23/.0076, AC 1100/660 volt including taking down existing unserviceable cable complete all as specified and as directed.
S&F Metallic fastener screw 75mm long 6mm dia with bolt for hanging Geyser complete all as directed.
S&F Multifunction safety valve cast copper alloy 15 mm dia ISI marked complete including taking down existing valve complete all as specified and as directed.
S&F 3 Pin plug top 15 amps complete ncluding taking down existing top complete all as specified and as directed.
S&F Sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20. Amps, 240 volts,10 KA complete fixed in repair complete all as specified and as directed.
S&F MCB SP 6 to 40 Amps, 240 volts 'B' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair complete all as specified and as directed.
S&F MCB SPN 6 to 40 Amps, 240 volts 'B' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair complete all as specified and as directed..
S&F MCB TPN 63 Amps, 415 volts 'B' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair complete all as specified and as directed.
S&F MCB TPN 100 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete fixed in repair complete all as specified and as directed.
S&F Heating element 1.5 KW 230 volt, ISI marked, round /triangular type as per sample for storage type electric water heater including taking down existing unserviceable element complete all as directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 10 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 10 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 6 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required in 6 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 4 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 4 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. Make of wire : Finolex, Plaza, Havells, Polycab NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for Sub main wiring with two single core PVC insulated unsheathed FR cable 1100 Volt grade, 2.5 Sqmm size with multi stranded copper conductor drawing into and including PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 2.5 Sqmm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB complete all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for Water heater (Geyser) storage type, electric,capacity 25 litres five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMGTWH025or equivalent in Bajaj/Usha/Recold
M&L for Water heater (Geyser) storage type, electric,capacity 50 litres five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like fastensers, nuts, washers complete all as specified and directed. Make: Havells cat part No. GHWAMESWH050 or equivalent in Bajaj/Usha/Recold
M&L for Water heater (Geyser) storage type, electric,capacity 100 litres five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rustproof metal body, stainless steel inner container, high efficiency heating element, autocut thermostate, pressure release safety system, fire retardent cable with 3 pin plug top, white colour including fixing accessories like PCC/Bricks foundation, bolts, nuts, washers and fastensers complete all as specified and directed. Make: Havells cat part No. GHWAMESWH100 or equivalent in Bajaj/Usha/Recold
S&F Supply only top plug 15 amp, 240 volts, ISI marked.
S&F Supply only top plug 5 amp, 240 volts, ISI marked.
S&F Switch piano, flush type, single pole one way 15 Amp fixed in repair complete all as specified and directed
S&F Bib tap cast copper alloy with crutch or butter fly handle screwed down 15mm bore including taking down existing tap etc complete all as specified and directed.
S&F Stop valve cast copper alloy chromium plated screwed down high pressure with crutch or butter fly handle 15mm bore including taking down existing tap etc complete all as specified and directed.
M&L for Circuit/submain wiring with single core FRLS PVC insulated copper stranded conductor cable drawing into existing PVC rigid conduit surface /concealed/ casing caping as required of following sizes, including taking down unserviceable existing wiring etc complete of following sizes as directed.
S&F Metal clad industrial plug top and porcelain socket 3 pin 20 Amps with earth pin 230 to 250 Volts including taking down existing complete all as specified and directed.
Supply and fix in repair Pressure release valve 15mm dia for 50 Ltr capacity geyser complete all as specified and directed.
Supply and fix in repair Rubber gasket for fall plate for 25 Ltr capacity geyser complete all as specified and directed
Supply and fix in repair Rubber gasket for fall plate for 50 Ltr capacity geyser complete all as specified and directed.
M&L for PVC insulated copper cable size 3 core 2.5 sq mm, AC 1100/660 volt including taking down existing unserviceable cable complete all as specified and directed.
M&L for PVC insulated copper cable size 3 core 1.5 sq mm, AC 1100/660 volt including taking down existing unserviceable cable complete all as specified and directed.
Supply and fix in repair Thermostat for 100/150 Ltrs tank capacity geyser of existing pattern as required at site complete all as specified and directed.
Socket outlet, multipurpose 2 in 1 5 pin, 15 Amp fixed in repair complete all as specified and directed
Supply only REO Modular AC MCB box protected socket PVC pastic base 3-Model including 25 amps plug top and MCB 25 amp fixed in repair complete all as specified and directed.
Extruded aluminium surface and wall mounted LED batten fitting, 22 W, 230 volts AC , with all accessories complete suitable for and including 20 W LED tube rod complete and connected the same with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down existing fitting complete all as directed. Make: Philips cat part No. BN021C LED 22S PSU CW GR S2 or equivelent of Wipro/Havells.
Extruded aluminium surface and wall mounted LED batten fitting, 10 W, 230 volts of Extruded aluminum AC, all accessories complete suitable for and including 10 W LED tube rod etc and connected with using PVC sheathed and insulated 3 core flexible 23/0.0076 copper conductor cable including all accessories and fixing arrangement for fixing the light fitting to walls including taking down. Make:- Philips cat part No. BN021 LED 10S 6500 PSU GR S1 or equivalent of Havells/ Wipro.
KULDEEP SINGH
M/s Anamika Enterprises
JS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .