Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹98.0 L
EMD Value
₹2.0 L
Closing Date
16 Oct 2026, 3:00 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
WORKS
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnoverof V/N or 'V' whichever is less; where V= Advertised value of the tenderin crores of Rupees N= Number of years prescribed for completion ofwork for which bids have been invited. The average annual contractualturnover shall be calculated as an average of "total contractualpayments" in the previous three financial years, as per the auditedbalance sheet. However, in case balance sheet of the previous year isyet to be prepared/ audited, the audited balance sheet of the fourthprevious year shall be considered for calculating average annualcontractual turnover. The tenderers shall submit requisite information asper Annexure-VIB, along with copies of Audited Balance Sheets dulycertified by the Chartered Accountant/ Certificate from CharteredAccountant duly supported by Audited Balance Sheet
a)The tenderer must have successfully completed or substantiallycompleted any one of the following categories of work(s) during last 07(seven) years, ending last day of month previous to the one in whichtender is invited: (i)Three similar works each costing not less than theamount equal to 30% of advertised value of the tender, or (ii)Two similarworks each costing not less than the amount equal to 40% of advertisedvalue of the tender, or (iii)One similar work costing not less than theamount equal to 60% of advertised value of the tender. (b) (1)In case oftenders for composite works (e.g. works involving more than one distinctcomponent, such as Civil Engineering works, S&T works, Electrical works,OHE works etc. and in the case of major bridges - substructure,superstructure etc.), tenderer must have successfully completed orsubstantially completed any one of the following categories of work(s)during last 07 (seven) years, ending last day of month previous to theone in which tender is invited: (i)Three similar works each costing notless than the amount equal to 30% of advertised value of eachcomponent of tender, or (ii)Two similar works each costing not less thanthe amount equal to 40% of advertised value of each component oftender, or (iii)One similar work each costing not less than the amountequal to 60% of advertised value of each component of tender. Note forb(1): Separate completed works of minimum required values shall alsobe considered for fulfillment of technical eligibility criteria for differentcomponents. (b)(2)In such cases, what constitutes a component in acomposite work shall be clearly pre-defined with estimated tender cost ofit, as part of the tender documents without any ambiguity. (b) (3) Toevaluate the technical eligibility of tenderer, only components of work asstipulated in tender documents for evaluation of technical eligibility, shallbe considered. The scope of work covered in other remainingcomponents shall be either executed by tenderer himself if he has workexperience as mentioned in clause 7 of the Standard General Conditionsof Contractor through subcontractor fulfilling the requirements as perclause 7 of the Standard General Conditions of Contract or jointly i.e.,partly himself and remaining through subcontractor, with prior approvalof Chief Engineer in writing. However, if required in tender documents byway of Special Conditions, a formal agreement duly notarised, legallyenforceable in the court of law, shall be executed by the main contractorwith the subcontractor for the component(s) of work proposed to beexecuted by the subcontractor(s), and shall be submitted along with theoffer for considering subletting of that scope of work towards fulfilmentof technical eligibility. Such subcontractor must fulfill technical eligibilitycriteria as follows: The subcontractor shall have successfully completedat least one work similar to work proposed for subcontract, costing notless than 35% value of work to be subletted, in last 5 years, ending lastday of month previous to the one in which tender is invited through aworks contract. Note: for subletting of work costing up to Rs 50 lakh, noprevious work experience of subcontractor shall be asked for by theRailway.
Note for Technical Eligibility Criteria: Work experience certificate fromprivate individual shall not be considered. However, in addition to workexperience certificates issued by any Govt. Organisation, workexperience certificate issued by Public listed company having averageannual turnover of Rs 500 crore and above in last 3 financial yearsexcluding the current financial year, listed on National Stock Exchange orBombay Stock Exchange, incorporated/ registered at least 5 years priorto the date of closing of tender, shall also be considered provided thework experience certificate has been issued by a person authorized bythe Public listed company to issue such certificates. In case tenderersubmits work experience certificate issued by public listed company, thetenderer shall also submit along with work experience certificate, therelevant copy of work order, bill of quantities, bill wise details of paymentreceived duly certified by Chartered Accountant, TDS certificates for allpayments received and copy of final/last bill paid by company in supportof above work experience certificate
Definition of Single Similar Work: For the purpose of this work, Single Similar work shall be taken as "Any signal interlocking works involving El 1.1.1 or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HASSDAC)or Automatic signalling"
27 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit full Bid Security and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract for works 2022, with all correction slips up-to-date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We offer to do the work for DRM/S&T/TVC, at the rates quoted in the attached schedule and hereby bind myself/ourselves to complete the work in all respects within the period of completion stipulated in the tender document, from the date of issue of letter of acceptance of the tender. The amount as stipulated in the tender document is herewith forwarded as Bid Security. Full value of the bid security shall stand forfeited without prejudice to any other right or remedies in case my/our Tender is accepted and if : (a) I/We do not execute the contract documents as stipulated in performance guarantee clause of GCC for works 2022 as detailed in general instructions. (b) I/We do not commence the work within seven days after receipt of orders to that effect.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of Bid Security and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Appostille certificate.
INSTRUCTIONS TO TENDERERS
The tenderer shall thoroughly go through the entire tender documents and strictly adhere the instructions and directions given at different pages.
Tender Document Cost for this work is Nil.
Unreleased Bid Security, if any, held with the Railway Administration, shall not be adjusted towards the Bid security to be remitted.
If the Tenderer(s) deliberately give(s) wrong information/ incorrect documents in his/their tender or create circumstances for the acceptance of his/their tender, the Railway reserves the right to reject such tender at any stage. The entire Bid Security and any other dues available with Railway against that contract will be forfeited. Action will be taken to suspend the business with the tenderer for a period of two years. In addition, Administration reserves the right to prosecute under suitable law.
All terms and conditions in the tender documents are binding on the Tenderers.
Railways reserves the right to accept or reject any or all the tenders and to award the work in whole or in part without assigning the reason for any such action.
The Tenderers are advised to visit the site of work in their own interest and acquaint themselves with the site conditions and expected quantum of work and assess all the site specific difficulties to be experienced while executing the same and the rate shall be arrived duly considering all the facts above and quoted in the tender. Any representation at a later date specifying the site difficulties shall not be considered.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. If the bidding unit is Above/ Below/ Par, the bidder can select the %Above, %Below or %At Par option from the drop down list in the same column. If the bidding rate is Rs. or Rs./ unit, the bidder has to quote his rate for the item group or individual item accordingly
All the bidders/tenders should ensure that they are GST compliant and their quoted tax structure/rates are as per GST Law
In case of any wrong information submitted by tenderer, the contract shall be terminated, Bid security, Performance Guarantee(PG) and Security Deposit(SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 2(Two) years
Provision of signalling arrangements in connection with TTR works and casual renewal of Bridge Sleepers in TVC division
TVC-SNT-SIG-26-27-22~SR
TVC-SNT-SIG-26-27-22
Open
Works - General
18 Months
Thiruvananthapuram, Kerala
₹0
₹2.0 L
24 Sept 2026
24 Sept 2026
2 Oct 2026
57 items across 1 schedule · ₹75,90,704.95 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers | 14.00 | 1,707.55 | 23,905.7 |
| 2 | Supply o f L o w maintenance secondary cells of t h e f o l l o w i n g c a p a c i t i e s w i t h necessary i n s p e c t i o n a s p e r specificatio n/ drawing/ description enclosed in this document.b)Supply of Secondary cells - 2V-80AH capacity | Numbers | 60.00 | 3,379.2 | 2,02,752 |
| 3 | Supply of 'B type choke IRS:S 65-83 | Numbers | 15.00 | 2,855.6 | 42,834 |
| 4 | Supply o f 2 4 Core x 1 . 5 Sq.mm PVC insulated Armoured, unscreened underground Railway Signalling copper cable as per IRS: S-63/2014 REV.4 | Metre | 4000.00 | 388.15 | 15,52,600 |
| 5 | S u p p l y o f 1 2 C x 1 . 5 S Q M M P V C insulated Armoured, unscreened underground Railway Signalling copper cable a s p e r IR S: S-63/2014 REV.4 | Metre | 3000.00 | 215.92 | 6,47,760 |
| 6 | S u p p l y o f Underground j e l l y fi l l e d 6 QUAD, 0.9MM Dia as per spec IRS:TC 30-05 with amd 5 or latest | Metre | 2000.00 | 301.05 | 6,02,100 |
| 7 | S u p p l y a n d provision o f n o r m a l j o i n t using T h e r m o s h r i n k jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 or latest.& jointing kit to be inspected by RDSO) for 4/6 quad cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing the same after completion o f cable j o i n t a s p e r t h e i n s t r u c t i o n o f Railway representative at site. | Numbers | 30.00 | 4,628.91 | 1,38,867.3 |
| 8 | Supply and provision of derivation joint complete for 6 Quad cables using thermoshrink jointing kit for LC's/stations | Numbers | 15.00 | 4,901.27 | 73,519.05 |
| 9 | Supply of RCC cable markers (Supply of RCC cable markers a s p e r drawing No.CSTE/CN/OFC/1. T h e lettering o n the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.) as per drawing enclosed | Numbers | 165.00 | 262.65 | 43,337.25 |
| 10 | Preparation of Cement concrete for covering of G I Pipes/cables. Providing & Laying in position c e m e n t c o n c r e t e o f specified proportion i n c l u d i n g c o s t o f cement, centering and shuttering with 1:3:6 composition 1 Cement: 3 Sand: 6 grade stone aggregate 25mm nominal size) (Cement, M-Sand, stone jelly of 25mm and a l l other misc materials required f o r the work should be supplied by Contractor). | cum | 15.00 | 9,361.46 | 1,40,421.9 |
| 11 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre | 3300.00 | 64.1 | 2,11,530 |
| 12 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by r a m m i n g a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / R C C p i p e s . During excavation o f trench, i t has t o b e ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e from t h e b o t t o m o f sleepers for track crossings. Laying of cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 96.00 | 385.45 | 37,003.2 |
| 13 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply o f DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre | 60.00 | 501.03 | 30,061.8 |
| 14 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre | 210.00 | 208.54 | 43,793.4 |
| 15 | Provision o f G I pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported b y concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall b e closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out a s per the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule). [Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Metre | 150.00 | 182.87 | 27,430.5 |
| 16 | Laying o f signaling/power/ telecommunication cables a s p e r c a b l e plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included i n this schedule). | Metre | 9000.00 | 18.18 | 1,63,620 |
| 17 | Placing of one row of country bricks of size approximately 2 2 0 m m x 1 0 0 m m x 60mm breadth wise horizontally above the cables in 0.3m width trench.[Country bricks of size 220mm x 100mm x60 mm (approximately) shall be supplied by the Contractor]. | Metre | 3300.00 | 62.99 | 2,07,867 |
| 18 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling." | Metre | 3300.00 | 15.4 | 50,820 |
| 19 | "Digging of pit to a depth of 800mm of size 300mmX300mm, casting of concrete foundation o f size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. T h e cable markers s h a l l b e provided a t an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions a n d also a t every track/road crossing." | Numbers | 165.00 | 123.35 | 20,352.75 |
| 20 | " R o a d c r o s s i n g / T r a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 t o 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe o r any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre | 72.00 | 1,351.45 | 97,304.4 |
| 21 | Supply o f KLCR relays 24V, A C I (Supply of Key Lock Checking Relay (KLCR) with one number K- 50 neutral Relay to work on 24V DC n o n AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt-1 or latest (with one extra ward plate andwith case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers | 20.00 | 10,722.72 | 2,14,454.4 |
| 22 | Supply of electronic time delay units (120/60 secs) with plug boards, connectors and retaining c l i p s w i t h n e c e s s a r y i n s p e c t i o n as per specification/ drawing/ description enclosed in this document. | Numbers | 40.00 | 2,742.03 | 1,09,681.2 |
| 23 | Supply of lamp proving relays(QECX-61) for a)LED aspects with plug boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers | 20.00 | 5,901.5 | 1,18,030 |
| 24 | Supply of QBCA1 - heavy duty contact relays with necessary inspection as per specification/ | Numbers | 25.00 | 6,613.75 | 1,65,343.75 |
| 25 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set | 10.00 | 4,945.51 | 49,455.1 |
| 26 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. b)Wiring of Signal/ Point/ LC control circuit (up to 8 relays/plug in type) | Set | 6.00 | 8,786.26 | 52,717.56 |
| 27 | Manufacture and supply o f M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug in type as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing o f p l u g boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F 5 , wiring a n d termination as per approved c i r c u i t d i a g r a m a n d painting the particulars.[Wire P V C coppe r, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, f o r fi x i n g resistors and condensers, M S flats 2 5 m m x 6 m m brass bolts a n d n u t s , paints, soldering materials, resistors, condensers and all other miscellaneous materials required f o r the work shall be supplied by the contractor]. c)Wiring of Signal/ Point/ LC control circuit (up to 12 relays/plug in type) | Set | 4.00 | 11,355.02 | 45,420.08 |
| 28 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit | 120.00 | 167.99 | 20,158.8 |
| 29 | Fixing o f P B T terminal block/ P B T fuse block, rubber grommets, clamping of cables using t e a k w o o d c a b l e c l a m p s a n d base planks, termination of cables, provision of ND type fuses o f required capacities, provision o f copper bus b a r f o r supply terminals, wiring, provision of termination particulars diagra m b o a r d using plywood of thickness 12mm - teakwood finish of size 1800mm x 1 2 0 0 m m w i t h Aluminium grooved channel frame i n t h e relay room. The blank spaces over the top of the cable termination rack shall b e covered with phynolic sheet of thickness 3mm wherever required. The termination a n d cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply o f P B T terminal blocks 25mm & 60mm centers and PBT Fuse blocks is not covered in the schedule) [Wire PVC 3/0.75mm copper, b r a s s bolts and n u t s and washers, f o r fi x i n g PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 5 0 m m x 50mm for c a b l e c l a m p s , 25mmx 100mm f o r base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic s h e e t 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b)Termination u s i n g P B T f u s e b l o c k i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit | 15.00 | 201.27 | 3,019.05 |
| 30 | Fi x i n g o f additional p l u g b o a r d s , 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall b e provided w h e r e v e r required. Alterations t o Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , p l u g boards, connectors and retaining c l i p s a n d 5 0 way terminal boards is not covered in this schedule). [Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors a n d condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made o f PVC, paint, v a r n i s h a n d a l l other miscellaneousmaterials required f o r t h e work shall be supplied by the Contractor ] | Per Relay | 30.00 | 726.5 | 21,795 |
| 31 | Carrying out alterations to the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. T h e w o r k includes painting alterations a n d releasing the unwanted wires carefully without disturbing the existing wiring. [ W i r e P V C 1 6 / 0 . 2 m m c o p p e r , soldering m a t e r i a l s , b u n c h i n g t h r e a d s , condensers, resistances and teakwood plank for fixing them a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay | 36.00 | 695.67 | 25,044.12 |
| 32 | S u p p l y o f D o u b l e w a l l e d corrugated p i p e - 1 0 3 . 5 m m i n n e r d i a & 1 2 0 m m o u t e r dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6 m o f pipe as per Technical specification | Metre | 216.00 | 365.19 | 78,881.04 |
| 33 | Supply of GI pipes - 50mm dia -3.65mm thick as per Technical specification | Metre | 126.00 | 457.88 | 57,692.88 |
| 34 | Supply of GI pipes - 100mm dia-4.5mm thick as per Technical specification | Metre | 90.00 | 1,119.16 | 1,00,724.4 |
| 35 | S u p p l y o f High-Density Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters a s p e r specification N o . I S 4984: 2016 with latest amendments a n d Material Grade:PE 80 | Metre | 72.00 | 853.55 | 61,455.6 |
| 36 | Supply of nylon Insulations for IRS point machine | Set | 30.00 | 1,671.75 | 50,152.5 |
| 37 | Supply of Bond Pins (pack of 100) | Numbers | 60.00 | 191.85 | 11,511 |
| 38 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. a)Supply of PBT terminals 25mm centre. | Numbers | 600.00 | 61.44 | 36,864 |
| 39 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. b)Supply of PBT terminals 60mm centre. | Numbers | 750.00 | 93.02 | 69,765 |
| 40 | Supply o f P B T terminals 25mm/ 60mm centre and PBT Fuse blocks with necessary inspection a s p e r specification/ drawing/ description enclosed in this document. c)Supply of PBT fuse block without ND fuse | Numbers | 150.00 | 103.84 | 15,576 |
| 41 | Supply of Red Oxide Paint | Litre | 80.00 | 203.96 | 16,316.8 |
| 42 | Supply of Aluminium Paint | Litre | 60.00 | 352.43 | 21,145.8 |
| 43 | Installation of combined type point machine-IRS t y p e a n d connecting a l l ground connections including wiring and termination in point machine a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm c o p p e r w i r e and p a i n t i n g . This work i n c l u d e s p r o v i s i o n of insulation to stretcher bars, throw b a r l u g and "D" bracket w h e r e v e r r e q u ir e d , c u t t i n g of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required f o r t h e work shall be supplied by the Contractor]. | Numbers | 63.00 | 16,383.88 | 10,32,184.44 |
| 44 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers | 6.00 | 4,234.65 | 25,407.9 |
| 45 | Alteration t o existing D C Track Circuits to suit RE/Non R E standard a s p e r approved signaling p l a n . T h i s w o r k includes provision of double bonding and parallel jumpers, provision o f bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track l e a d connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers | 6.00 | 3,850.31 | 23,101.86 |
| 46 | "Excavation o f pit, casting concrete foundation and erection o f apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing o f o n e hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & n u t s a n d a l l o t h e r miscellaneous materials required f o r t h e work shall b e supplied by the Contractor]""" | Numbers | 4.00 | 8,787.04 | 35,148.16 |
| 47 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. T h e w ork includes ensuring the safety of the signaling system, releasing t h e cable coils to g i v e a c c e s s for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative a t s i t e . I f the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. b) Shifting of apparatus case (half) | Numbers | 6.00 | 3,545.06 | 21,270.36 |
| 48 | Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. T h e w ork includes ensuring the safety of the signaling system, releasing t h e cable coils to g i v e a c c e s s for shifting/turning t h e location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative a t s i t e . I f the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. c) Shifting of apparatus case (Quarter) | Numbers | 60.00 | 2,929.01 | 1,75,740.6 |
| 49 | Termination o f n e w main/tail c a b l e s o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r a p p r o v e d circuit diagram. T h e terminal particulars a r e to be repainted /corrected o n t h e doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry o f n e w cables in the apparatus cases w ith masonry brick work and sealing the bottom o f the apparatus cases/ cable termination racks w ith cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall b e supplied b y the contractor]. (Per Unit = Per Terminal block) | Per Unit | 375.00 | 73.59 | 27,596.25 |
| 50 | Termination o f main, tail, Signaling and power cables a n d internal w i r i n g on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base p l a n k , fi x i n g of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing o f terminals/ fuse blocks o n t h e terminal b o a r d , drilling of necessary h o l e s , termination o f cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso on the inner side o f t h e d o o r s of apparatus cases. After terminations are "over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n t h i s schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit | 168.00 | 172.14 | 28,919.52 |
| 51 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit | 380.00 | 151.09 | 57,414.2 |
| 52 | Termination o f main, tail, Signaling and power cables a n d internal wiring b y fixing additional terminals/ fuse blocks o n the existing terminal boards of apparatus cases, cable termination boxes etc. T h e work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, o n the existing terminal boards, drilling o f necessary holes, termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, as p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e s i d e openings of apparatus case foundation shall b e closed with brick work, cement plastered, the inter-space filled with M s a n d u p t o b a s e l e v e l a n d the bottom surface s h a l l b e s e a l e d w i t h sealing compound. b)Termination of cables o n PBT fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit | 60.00 | 188.86 | 11,331.6 |
| 53 | Installation of charged secondary cells of the f o l l o w i n g c a p a c i t i e s i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit | 60.00 | 491.59 | 29,495.4 |
| 54 | Provision of E type lock with key for fixing the same in LC/HP/FP Locks/SM slides | Numbers | 112.00 | 697.45 | 78,114.4 |
| 55 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections a n d o t h e r accessories available complete without a n y damage t o the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. | Numbers | 63.00 | 2,698.69 | 1,70,017.47 |
| 56 | Protection adjustments a n d re-instating of S&T gears by deputation of Helpers/Unskilled Labour f o r executing additional S & T portio n o f the works. The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- Days | 104.00 | 847.59 | 88,149.36 |
| 57 | Protection, adjustment a n d reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work c a n involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cables, minor patch work on damages at location box, Plastering, Concreting b r i c k w o r k , wiring alterations, cable jointing etc a s per instruction of Railway representatives at size. | Man- Days | 78.00 | 1,073.45 | 83,729.1 |
| Schedule total | ₹75,90,704.95 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022.pdf
ATTACHMENT
GCCCorrectionslip1-5.pdf
ATTACHMENT
GCCCorrectionslip6-11.pdf
ATTACHMENT
SOR2022BOOKLET.pdf
ATTACHMENT
LetterPoliceVerification.pdf
ATTACHMENT
CableCutpenaltyLetter.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf Model form of Bank Guarantee
ATTACHMENT
ScopeofworkandATC_5.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .