Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.7 LAccepted-Finance | L1 | Accepted-Finance Lowest Vendor | |
| 2 | L2₹75.6 L+₹2.9 L (3.99%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹77.6 L+₹4.9 L (6.74%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹78.6 L+₹5.9 L (8.11%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹82.8 L+₹10.1 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
9 Apr 2025, 6:00 pmClosed
GE (I) DM, Visakhapatnam
GE (I) DM, Visakhapatnam
DAY TO DAY MAINTENANCE, CALL ON REPAIRS FOR 24HRS AND ATTENDING BREAKDOWNS AND ALLIED WORKS INCLUDES REPLACEMENT OF UNSV ITEMS FOR LT PANELS, DOL AND STAR-DELTA STARTERS, METERING EQUIPMENT, SWITCH GEARS, PRESSURE TRANSMITTERS, MAIN AND AUXILIARY CON
2025_MES_700290_1
8258/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (I) DM, Visakhapatnam
₹1.8 L
Yes
7 Oct 2025
5 Mar 2025
11 Apr 2025
5 Mar 2025
9 Apr 2025
26 Mar 2025
Amount
Attending day to day work and breakdown on call for uninterupted shore power supply to LT Panels and DOL starter of NDD pump house equipment for carrying out following Repairs, Overhauling, Servicing, Preventive Maintenance and refixing the same after carrying out rapairs / overhauling complete all as specified and as directed : (a) Check and found if any cracked case when inspected should be replaced. (b) Check all contacting tips condition weather they are in good condition or corroded, if corroded do proper alchohol clearing. (c) Check alignment of foundation and make it in exact fixing location and provide grounding facility. (d) Check the compotnents of the LT panel with actual designs as provided drawings.
(e) Check all mechanical interlocks and ensure all connections in tightining. (f) Check phasing connection of busbar with provided drawings. (g) Mechanical check and visual inspection for air circuit breakers and moulded case circuit breakers. (h) Check the coil codtion and current ratings while in operation. (j) Check the correct opreation of NO & NC of auxilary contacts (k) Verify proper operation and remove any accumulation of dust material on moving parts and contacts and clean upto zero (l) Contractor shall not claim for outsourcing Note: All Consumables & spares will be supplied by firm only.
Supply only the following spare parts for LT Panel & Switch Gear as specified and as directed.
Supply only ACB 3 pole 415 V, with thermal Magnetic Release of capacity 1250 A with breaking capacity 50 KA - L&T, CN - CS, 1250 S1 all as specified and directed.
Supply only ACB 3 pole 415 V, with thermal Magnetic Release of capacity 800 A with breaking capacity 50 KA - L&T, DN3B, 800M, 800A, VIMP 8KV, ICU- 50KA, ICS- 100% all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 630 A with breaking capacity 36 KA - L&T, DN3, 630M, 630A, VIMP 8KV, ICU- 50KA, ICS - 100% all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 400 A with breaking capacity 36 KA - L&T, DN3, 400M, 400A, VIMP 8KV, ICU- 50KA, ICS - 100% all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 250 A with breaking capacity 36 KA- L&T, DN2, 250D, 250A, VIMP 8KV, ICU- 50KA, ICS - 100%
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 100 A with breaking capacity 36 KA- L&T, DN0 - 100D, 100A, VIMP 8KV, ICU- 50KA, ICS - 100% all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 800 A with breaking capacity 36 KA SIEMENS - 3VA1580-5GF42-OAAO, 800A all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 800 A with breaking capacity 36 KA SIEMENS - 3VA1340-5EE32, 400A all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 200 A with breaking capacity 36 KA SIEMENS - 3VA1220-4EE32, 200A all as specified and directed.
Supply only MCCB 3 pole 415 V, with thermal Magnetic Release of capacity 160 A with breaking capacity 36 KA SIEMENS - 3VA1116-4GE42,160A all as specified and directed.
Supply only MCB 3 pole 415 V, with thermal Magnetic Release of capacity 32 A with breaking capacity 10 KA SIEMENS - 3VA1132-3EE32,32A all as specified and directed.
Supply only components/ material/ item/ spare of DOL starters as specified and as directed.
MAIN CONTACTOR - L&T, MNX 9
AUX. CONTACTOR - L&T, MX0, 22E
AUX. CONTACTOR - L&T, MNX, A1
OLR - L&T, MN2, 25A
MCB - 3POLE, C-25, 25A
INDICATION LAMPS - RED
INDICATION LAMPS - GREEN
PUSH BUTTON ON/OFF (NO,NC) - RED
PUSH BUTTON ON/OFF (NO,NC) - GREEN
SIEMENS,SIRIUS-3RT2026-1AP00, WITH 3NO+2NC
SIEMENS,SIRIUS-3RT2018-1AP01, WITH 3NO+2NC
SIEMENS,SIRIUS-3RT2027-1AL20
SIEMENS,SIRIUS-3RH2122-1AP00
MCB-3POLE,C-25,25A
INDICATION LAMPS-RED, GREEN, LED, 230V
INDICATION LAMPS-RED, YELLOW, BLUE, LED, 230V
PUSH BUTTON ON/ OFF( NO, NC ) RED, GREEN
EMERGENCY STOP, 230V ,10A
Attending day to day work and breakdown on call for uninterupted shore power supply to Star-Delta Starters, Main & Auxilary contacts of NDD pump house equipment for carrying out following Repairs, Overhauling, Servicing, Preventive Maintenance and refixing the same after carrying out rapairs / overhauling complete all as specified and as directed : (a) Check and found if any cracked case when inspected should be replaced. (b) Check all contacting tips condition weather they are in good condition or corroded, if corroded do proper alchohol clearing. (c) Check alignment of foundation base and make it in exact fixing location and provide grounding facility. (d) Check the compotnents of the Star-Delta starter with actual designs as provided drawings. (e) Check all mechanical interlocks and ensure all connections in tightining.
(f) Check phasing connection of busbar with provided drawings. (g) Mechanical check and visual inspection for Star-Delta Starter moulded case circuit breakers. (h) Check the coil codtion and current ratings while in operation. (j) Check the correct opreation of NO & NC of auxilary contacts (k) Verify proper operation and remove any accumulation of dust material on moving parts and contacts and clean upto zero (l) Contractor shall not claim for outsourcing Note: All Consumables & spares will be supplied by firm only.
Supply only components/ material/ item/ spare of Star-Delta starters as specified and as directed.
Main Contactor L&T, MNX 225 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 140 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 110 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 95 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 80 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 70 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 50 WITH 2NC+2NO, COIL - 240V
Main Contactor L&T, MNX 32 WITH 2NC+2NO, COIL - 240V
AUX. CONTACTORS - L&T, MNX0 WITH COIL - 240V
TIMER (ELECTRONIC TIMER) Y-A, GIC 12SDTO MICON 175
OLR L&T, MN12, NORMAL CT-RATIO - 30
OLR L&T, MR2745
MCB, 2 POLE - 10A
EMERGENCY PUSH BUTTON (NC), 240V, 10A
START PUSH BUTTON (NO), 240V, 10A
SIEMENS,SIRIUS-3RT2036-1AL20
SIEMENS,SIRIUS-3RT2036-1AG20
SIEMENS,SIRIUS-3RT1066-6….6
SIEMENS,SIRIUS-3RT 1054-6…6
SIEMENS,SIRIUS-3RT1064-6….6
INDICATION LAMPS-RED, GREEN, LED, 230V
INDICATION LAMPS-RED, YELLOW, BLUE, LED, 230V
PUSH BUTTON ON/ OFF( NO, NC ) RED, GREEN
EMERGENCY STOP, 230V ,10A
Attending day to day work and breakdown on call for uninterupted shore power supply to Metering Devices of NDD pump house equipment for carrying out following Repairs, Overhauling, Servicing, Calibration, Preventive Maintenance and refixing the same after carrying out rapairs / overhauling complete all as specified and as directed : (a) Metering Devices visual inspection, cleaning and tightening of connections. (b) Check the device and found any cracked case and unclear display when inspected should be replaced. (c) Verify proper operation and remove any accumulation of dust of material on moving parts. (d) Calibrate the device by Authorised agency and display the calibration talley on every device. For calibration, the witness of the user rep is mandatory along with Authorised/ competent person. (l) Contractor shall not claim for outsourcing Note: All Consumables & spares will be supplied by firm only.
Supply only components/ material/ item/ spare of Metering Devices as specified and as directed.
SECURE ELITE 440 MULTI LINE DIGITAL DISPLAY PANEL METER (Multi Function Meter)
ELMEASURE ALPHA +3A
ELMEASURE ALPHA +3V
Protection Relay L&T MPR 300
Protection Reley SIEMENS-7SR10 ( 7SR1053-2LA21-2E AO/EE)
Current Transformer (CT) CT RATING 300/ 5A
Timer SIEMENS, 3RP 1576-INP30 (STAR-DELTA
Repair and replacement of unsv ACBs/ MCCBs/ MCBs along sub electric/ electronic protection units of capacity (100 A – 1250 A) range include taking out & replacing the damaged doors of LT panels and handover to user department all as specified and directed.
Repair and replacement of unsv Switch Gears include taking out & replacing the damaged doors of LT panels and handover to user department all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. mm 3.5 core including taking out old unserviceable comlete all as specified and directed.
All as per item No.11.00 above, but of capacity 150 sq. mm 3.5 core
All as per item No.11.00 above, but of capacity 16 sq. mm 4.0 core
All as per item No.11.00 above, but of capacity 10 sq. mm 4.0 core
All as per item No.11.00 above, but of capacity 4 sq. mm 4.0 core
M/S SRI VENKATA BHAVANI CONSTRUCTIONS (BID ID -3274738)
aswitha engineering works (BID ID -3275642)
AARAV POWER CONTROLS (BID ID -3278985)
CIVILEC ENGINEERING WORKS (BID ID -3278441)
BALAJI MATRIX HOLDINGS (BID ID -3279119)
SOUTHERN BUILDERS (BID ID -3278713)
SPAAN Infratech (BID ID -3278870)
S.S.TRADERS (BID ID -3278920)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .