Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.7 L+₹1.7 L (24.9%)Rejected-AOC | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
6 Sept 2021, 6:00 pmClosed
BA Nirmal Kumar EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_468935_1
8625
Open Tender
Civil Works - Canal
Item Rate
150 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹16,000
Yes
2 Dec 2021
18 Aug 2021
7 Sept 2021
18 Aug 2021
6 Sept 2021
24 Aug 2021
19 Aug 2021 - 20 Aug 2021
Amount
Excavation in trenches nexc 1.5 mtr wide and n exc in depth for taking out cable / pipe line n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil complete.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm. Complete
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point complete.
M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete.
M&L well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete
Supply, Laying jointing and testing in replacement electric under ground LT cable 95 Sqmm 3.5 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.
Supply, Laying jointing and testing in replacement electric under ground LT cable 70 sqmm 3.5 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.
Supply, Laying jointing and testing in replacement electric under ground LT cable 50 sq mm 3.5 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.
Supply, Laying jointing and testing in replacement electric under ground LT cable 25 sq mm 3.5 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.
Supply, Laying jointing and testing in replacement electric under ground LT cable 16 sq mm 4 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.16 sq mm 4 core
Supply, Laying jointing and testing in replacement electric under ground LT cable 10 sq mm 2 core PVC / XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches, ducts, pipe on walls, poles etc. Complete.
M&L for GI tubing light grade 50 mm dia bore fixed on wall / pole laid in trenches / under road complete.
M&L for KAPITRODE Earthing with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25x5mm dia galvanised iron strip including the following, : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450x450x450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost complete.
M&L for in replacement, installing commissioning and testing of vertical switch air break gang operated HV 11 KV triple pole out door type and rated capacity 200 Amp with 9 insulator and steel frames mechanically operated mechanism consisting of three male contacts & three female contacts of tinned copper, three arching horns, three MS jumper carrier equipped with braided copper belt , operating rod of light grade 25mm bore GI pipe of suitable length worked from ground level with locking arrangement with clamp of flat iron 50X6 mm complete and testing on load.
Supply, installing, commissioning and testing in replacement of vertical expulsion type drop out fuse unit HV 11 KV triple pole out door type and rated capacity 200 complete.
S&F in replacement steel tubular swaged cast iron plate base plate, finial plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtr including earth work, PCC for foundation, copping all around the pole duly painted with aluminium paint over a red oxide primer as per SSR Part I complete.
Dismantling / taking out old defective cable from street light poles (Junction box to fitting / overhead line to fitting) and S&F 4 Sqmm two core aluminium conductor multistranded / solid on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete
Dismantling / taking out old defective cable form street light poles (Junction box to fitting / overhead line to fitting) and S&F 6 Sqmm two core aluminium conductor multistranded / solid on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete
S&F in replacement 25 mm bore grade GI pipe medium grade fixed as bracket for street light on LT poles / walls, suitable for street light fittings, not less than 1.20m long and bent to shape as required complete.
S&F in replacement 40 mm bore grade GI pipe medium grade fixed as bracket for street light on LT poles / walls, suitable for street light fittings, not less than 1.20m long and bent to shape as required complete.
S&F in repair post top lantern fitting comprising with LED lamp similar to CAT Part No. LPTO-40-CDL/M, 40 watt of CG complete.
M&L in replacement MCCB 4 pole 100 Amps, 415 volts, 25 KA complete.
M&L in replacement MCCB TPN 63 Amps, 415 volts, 16 KA complete.
S&F in repairs MCCB 4 pole 160 Amps, 36 KA thermal magnetic complete.
S&F in repairs MCCB 4 pole 250 Amps, 36 KA thermal magnetic complete.
S&F in repairs Resin filled capacitor heavy duty 7.5 KVAr complete.
S&F in repairs Resin filled capacitor heavy duty 10 KVAr complete.
S&F in repairs Resin filled capacitor heavy duty 15 KVAr complete.
Supply, install, testing & commissioning in replacement of factory made Junction box of 0.75m x 0.60m x 0.45m outdoor type pedestal mounting, approx height 0.45mtr from ground level totally enclosed made with MS sheet of 3.15 mm thick & dust proof busbar chamber, double shutter, front & back opening incl PCC (1:3:6) type C1 for pedestal of suitable size incl provision of incoming MCCB 250 Amp 25 KA & outgoing comprising Copper bus bar 3 Nos for phase of size 20 x 10mm for neutral 10 x 10mm, copper conductor with PVC insulated cable lugs etc and duly powdered coated etc complete.
CENTAUR ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .