| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.7 LAccepted-Finance R O SUBHAN COTTAGE HIMGIRI COLONY DHALLI SHIMLA 12 H P | ₹2.7 L | 1 | Accepted-Finance L1 |
| 2 | 2₹2.8 LRejected-Finance | ₹2.8 L | 2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | ASHISH THAKUR L1 | VIRENDER KUMAR L2 |
|---|---|---|---|---|---|
| 1.00 | Excavation in foundation and trenches etc. in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling / wedging out of rock / where blasting prohibited) saturated soil stacking the excavated soil as directed by the Engineer-in-charge clear from the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge in all leads and lifts. | 5.46 | Cum | 405 ₹2,211.30 | 408 ₹2,227.68 |
| 2.00 | Providing and laying cement concrete 1: 6: 12 (1Cement: 6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth in all leads and lifts | 1.74 | Cum | 7,000 ₹12,180 | 7,050 ₹12,267 |
| 3.00 | Random rubble masonry coursed with hard stone of approved quality in foundation and plinth including racking out joints in CM 1:6(1cement:6sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge. | 3.18 | Cum | 8,000 ₹25,440 | 8,050 ₹25,599 |
| 4.00 | Brick work using commcon burnt clay building bricks 2nd class in super structure above plinth level upto floor two level in cement mortar 1:4 (1cement:4sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge. | 7.67 | Cum | 10,000 ₹76,700 | 10,500 ₹80,535 |
| 5.00 | Providing wood work in frames of doors, windows, clearstory, windows and other frames wrought framed and fixed in position 2nd class deodar wood in all leads and lifts and to the entire satisfaction of the Engineer-in-charge. | 0.1 | Rmt | 1,01,000 ₹10,100 | 1,01,060 ₹10,106 |
| 6.00Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens ballies, height of propping and cent ring below supporting floor to ceiling not exceeding 4 mtr and removal of the same for in-situ reinforced concrete and plain concrete work in:- | |||||
| 6.01 | Flat surfaces such as soffits of suspended floor landings and the like up to 200mm thickness and to the entire satisfaction of the Engineer-in-charge. | 16.84 | Sqmt | 500 ₹8,420 | 550 ₹9,262 |
| 6.02 | Beams, cantilevers, girders & lintels, sides & soffits of beams, haunching, cantilevers,bressumers 1.00 mts. In depth in all heights from floor and to the entire satisfaction of the Engineer-in-charge. | 7.87 | Sqmt | 400 ₹3,148 | 450 ₹3,541.50 |
| 6.03 | Edges of slab and breaks in floor and walls under 20 cm wide in all leads and lifts and to the entire satisfaction of the Engineer-in-charge | 17.44 | Sqmt | 120 ₹2,092.80 | 120 ₹2,092.80 |
| 7.00Providingand laying cement concrete 1:2:4 (1cement:2sand: 4 graded stone agg. 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for RCC work in | |||||
Tender Value
₹2.6 L
EMD Value
₹5,185
Closing Date
20 Feb 2026, 11:00 amClosed
Executive Engineer
Jal Shakti Division Bilaspur
Providing drinking water facility to mining affected area in GP Dhoun Kothi Dhar Tatoh Jamthal Panjgain Barmana in Tehsil Sadar District Bilaspur (SH Construction of single room pump house 11.97 sqmt. and storage of bleaching powder for existing bore
2026_HPIPH_128063_5
BLP-BLP-0736-NIT No. 12543-12643 Dated 08/02/2026
Open Tender
Civil Works
90 days
Sub Division Bilaspur Section NBT
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹5,185
3 Mar 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
20 Feb 2026
11 Feb 2026
Excavation in foundation and trenches etc. in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling / wedging out of rock / where blasting prohibited) saturated soil stacking the excavated soil as directed by the Engineer-in-charge clear from the edge of excavation and then returning the stacked soil in 15 cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge in all leads and lifts.
Providing and laying cement concrete 1: 6: 12 (1Cement: 6 sand:12 graded stone aggregate 40mm nominal size) and curing complete excluding the cost of form work foundation and plinth in all leads and lifts
Random rubble masonry coursed with hard stone of approved quality in foundation and plinth including racking out joints in CM 1:6(1cement:6sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Brick work using commcon burnt clay building bricks 2nd class in super structure above plinth level upto floor two level in cement mortar 1:4 (1cement:4sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providing wood work in frames of doors, windows, clearstory, windows and other frames wrought framed and fixed in position 2nd class deodar wood in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens ballies, height of propping and cent ring below supporting floor to ceiling not exceeding 4 mtr and removal of the same for in-situ reinforced concrete and plain concrete work in:-
Flat surfaces such as soffits of suspended floor landings and the like up to 200mm thickness and to the entire satisfaction of the Engineer-in-charge.
Beams, cantilevers, girders & lintels, sides & soffits of beams, haunching, cantilevers,bressumers 1.00 mts. In depth in all heights from floor and to the entire satisfaction of the Engineer-in-charge.
Edges of slab and breaks in floor and walls under 20 cm wide in all leads and lifts and to the entire satisfaction of the Engineer-in-charge
Providingand laying cement concrete 1:2:4 (1cement:2sand: 4 graded stone agg. 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for RCC work in
Suspended floor roofs landing shelves and their supports balconies, beams girders bressumers and cantilevers up to floor two level.
Providing tor steel reinforcement for RCC works including bending binding, cutting and placing in position complete in all depths and heights and to the entire satisfaction of the Engineer-in-charge.
6mm thick cement plaster to ceiling in cement mortar 1:3 (1cement: 3 sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
15 mm cement plaster in single coat of rough side of brick/Concrerete /stone walls for interior plastering up to floor two level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80 mm in girth and finished even and smooth CM 1:6 (1cement: 6sand) in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providingand fixing glazed and panelled , glazed or panelled shutters for doors, windows and clerestory windows including bright finished black enamelled iron butt hinges with necesssary screws (a) 40mm thick 2nd class deodar wood within all leads and lifts
Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil dirt grease and other foreign matter sand papering and knotting ready mixed paint brushing wood primer pink in all leads and lifts.
Painting two coats (excluding priming coat) on new wood based surface with ready mixed paint, brushing to give an even shade including cleaning of all dirt, dust and other foreign matter and sand papering and stopping with ready mixed paint other than white in all leads and lifts complete in all respect.
Distempring (two coat) with oil bound washable distemper of approved brand and manfuacture and of required shade on undecorated wall surfaces to give an even shade over and including a priming coatwith distemper primer of approved brand and manufacgure after throughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth priming coat with distemper primer and to the entire satisfaction of the Engineer-in-charge.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats) to give an even shade after throughly brushing the surface to remove all dirt and remains of loose powdered materials and to the enitre satisfaction of the Engineer-in-charge.
Providing and fixing anodized aluminium handles anodized transparent or dyed to required shade with necessary screw etc. complete in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providing and fixing anodized aluminium tower bolts (Berrel type) anodized transparent or dyed to required shade with necessary screw etc. complete 150x10mm
Providing and fixing anodized aluminium sliding door bolts anodized transparent or dyed to required shade with necessary screw etc.complete 150x16mm
Providing under layer for plinth protection of 75mm thick unconsolidated bed dry bricks/stone aggregate 40 mm nominal size wall rammed and unconsolidated and rammed and consolidated with fine sand including preparation of grade and to the entire satisfaction of the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6 (1cement: 3sand: 6 graded stone agg. 20mm nominal size) including finishing of the top surface of concrete smooth in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providing and fixing MS fan clamp (Type01( of 15mm dia MS barbent to shape with hooked enc in RCC slab during laying including painting the exposed portion of loop all as per standard design complete pump house in all leads and lifts and to the entire satisfaction of the Engineer-in-charge.
Providing 40mm thick cement concrete flooring 1:2:4 (1cement: 2sand: 4 graded stone aggregate 20mm nominal size laid in one layer finished with floating coat of neat cement and to the entire satisfaction of the Engineer-in-charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.24 MB
PWD6.pdf
Tender Documents • 0.34 MB
PWD8.pdf
Tender Documents • 1.43 MB
Termsandconditions.pdf
Tender Documents • 0.17 MB
BOQ_189175.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid