| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | ₹26.2 L | L1 | Accepted-AOC (L1) The lowest bidder |
| 2 | L2₹30.7 L+₹4.6 L (17.4%)Rejected-AOC | ₹30.7 L+₹4.6 L (17.4%) | L2 | Rejected-AOC Other than lowest bidder |
| 3 | L3₹30.8 L+₹4.6 L (17.7%)Rejected-AOC | ₹30.8 L+₹4.6 L (17.7%) | L3 | Rejected-AOC Other than lowest bidder |
| 4 | L4₹31.3 L+₹5.1 L (19.6%)Rejected-AOC | ₹31.3 L+₹5.1 L (19.6%) | L4 | Rejected-AOC Other than lowest bidder |
| 5 | L5₹31.8 L+₹5.7 L (21.7%)Rejected-AOC | ₹31.8 L+₹5.7 L (21.7%) | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
12 Mar 2020, 6:00 pmClosed
CWE(SUB) BARRACKPORE
Commander Works Engineer, Military Engineer Services, Post-Barrackpore Kolkata-700120
SPL REPAIRS TO LT PANEL BOARDS, FEEDER PILLARS, UG CABLES, TWO POLE AND FOUR POLE STRUCTURE, LT SWITCH GEAR ACCESSORIES AT BH, 05N DET NAVY, SFQ MD ACCN AND RCTC MD ACCN UNDER GE BARRACKPORE
2020_MES_324945_1
CWE/BKP/47 OF 2019-2020
Open Tender
Miscellaneous Works
Item Rate
180 days
GE BARRACKPORE
Class D and Category b (i)
5 documents required · 5 mandatory
₹500
GE BARRACKPORE
₹58,000
Yes
8 May 2020
13 Feb 2020
14 Mar 2020
13 Feb 2020
12 Mar 2020
27 Feb 2020
Amount
SCHEDULE 'A'
Taking out existing old unserviceable pole (09 and 11) metres long of any type from the PCC foundation, couping and including carefully taking down existing ACSR conductor,cables, street light, security light fitting, GI brackets, looping boxe, stay assembly of any type & patten etc, after disconnection of electric supply by using necessary T&P/Crane/ any mechanical method will be applied and disposal of debris upto distance not exc 100 m complete all as specified and directed. Note:- Hire charges of T&P / crane etc for disconnection of electric supply and cost of disposal of debris shall deemed to be included in the unit quoted rate.
Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black japan paint after preparation of surface complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid separately.
Supply, fixing and erection of steel tubular swaged type pole 11 metrs long, pole weight approximately 241 kgs, pole should be in one piece only and smooth finishing, ISI marked complete with all accessories such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified type 410 SP-56 and conforming to IS:2713-1980 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified. Notes:- (i) Excavation and earth work shall be measured and paid separately. (ii) Two/ Four pole structure preparation and connected accessories will be measured and paid separately.
Dismantling of existing old unserviceable insulators of any type and size from poles all as directed.
S&F insulator pin type porcelain vitreous, white, brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 1100 volt grade complete all as specified and directed.
S&F insulator disc type, porcelain, viterous, white/brown or green including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut bolts dia 20mm and 150mm height, 150mm dia dection of straps in 38x5mm for conductor working pressure 1100 volt grade complete all as specified and directed.
S&F loop type insulator, vitreous, porcelain white, brown or green, large size, over all dimension 150mm x 150mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
M&L cross arms, bracings, supports, clamps and back plates fabricated in structural steel sections including nuts, bolts,washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat zink primer and two coats of synthetic enamel paint and removing old unserviceable item complete all as specified and directed
M&L Aluminium conductor steel reinforced(ACSR), of any size, type, fixed to poles and stretching properly drawn for overhead lines on poles including binding at site to insulator with suitable size of wire and it is to be deremined by measuring horizontal distance between centre of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra addaed for sag including 15mm dia PVC seperater at equal interval and removing old unserviceable ACSR conductors complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C-1, of size (45X 45X 45) CM, RCC cover 1:2:4 type B1 of size (45X45X6) CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including dismantling and removing old item complete all as specified and directed. Note:- Nacessary, excavation and earth work shall be included in the quoted rate.
M&L Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip(25x4) mm size and from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C-1, of size (45X 45X 45) CM, RCC cover 1:2:4 type B1 of size (45X45X6) CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including dismantling and removing old item complete all as specified and directed. Note:- Nacessary, excavation and earth work shall be included in the quoted rate.
Supply, install, testing and commissioning of ACB 800 Amps 04 pole, 65 Ka, 415 volts and 50 Hz manual drawout type with microprocessor released, spring charged mechanism and the air circuit breaker shall be enclosed in CRCA sheet steel enclosure complete and all as directed. Note:- CRCA Sheet metal enclosure shall be measured and apid separately.
M&L for ACB sheeel steel enclosure made out of 02 mm thick CRCA sheet duly painted with powder coating in approved shade, rubber, gasket, hinged door having front and rear opening, locking arrangement and any manufacturer shall be follwed CPRI norms suitable for fixing of LT ACB draw out type , 03 phase, 04 pole , 415 volts and including providing of holes for incoming anf outgoing cables, CT's control fuses control wiring, pahes indication lamps, gland plate cover, danger notice plate and including incoming and out going suitable rating bus bars, neutral bars, earthing bars and including MS angle iron (50x50x6) mm with supports at a height 01 meter with red oxide primer and two coats of synthetic enamel paint to MS sections and embeded in floor with nacessary PCC foudation complete and all as directed. Notes:- (i) The contractor shall be arranged factory inspection and general and circuit lay out drawings as approved by the Accepting officer and Engr-in-charge before procurement (ii) Provision of ACB is not included in the scope of above item.
M&L stay assembly complete with accessories as shown in electrical plate No-1 SSRPt-I, dia of stay 20mm dia 190cm long stay wire 7/4 mm stranded including MS galvanised stay plate of size 300mmx300mmx6mm thick and galvanized thimble after dismantling of unserviceable stay set (above GL) including excavation in earth work, PCC (1:3:6) type C1 (using 20mm graded stone aggregate) foundation including dismantling of old unserviceable stay assembly complete all as specified and directed. Note:- Cost of excavation, concrete work, removing of surplus soil, returning filling shall deemed to be included in the unit quoted rate.
S&F cable junction box, water proof, fire retardent, out door type of approved size, hinged/screwed type, made of SMC plastic, single door with incoming and outgoing connector/terminals and comprising of MCB SP 6 Amps, 240V, 10KA, 'C' Series including galvanised flat iron clamps of size (25 x 5)mm thick - 02 Nos, GI nuts, bolts & washers etc for fixing on PCC/Steel tubular pole/ wall surface including taking down and removing of old unserviceable junction box complete all as specified and directed. (Make:- Sintex cat No. GSJB 4030/ Hensel cat No. K 9255 as approved by GE.)
S&F in repair PVC conduit heavy duty of size 20 mm dia from looping box to street light connector, holding in MS clamp of size (25 x 2) mm thick at every one metre, used in each pole, with necessary nut,bolts and washers etc including PVC sheathed three core multi-stranded copper conductor cable of size 1.5 sqmm from looping box to light fitting connector and complete all as specified and directed.
Supply, install,, testing and commissioning LT panel board outdoor type of size 2000mm long x 2000mm width x 650mm depth suitable for working on 03 phase, 04 wire, 415 volts, AC, 50Hz cubical and shall have air ventilation arrangement, IP-54 protection floor mounted, free standing , dust and vermin proof, made out of 3.15mm thick at outer sheet and 2.00mm thick at internal compartments CRCA sheet and nacessry angle/ flat irons duly powder coated, hinged doors with rubber gasket, handles. Panel shall have front and rear opening, ocking arrangement, cable alloys, cable entry holed for incoming and out going cables, busbar chamber and switch gear compartment, see through glass for ndicator lamps, control copper wiring and safety fuses, earthing terminals, affix danger notice plate, aluminum busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminum busbars only with RYB color code sleeves/taps and the panel will be mounted on 50mm x 50mm x 6mm MS angle iron frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminum lugs and cable glant and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B-1 with studs, bolts nuts and washers as per requirement and including comprising of following are give below notes of Srl No 18:-
All as per Srl item No 17 here-in-before Supply, install,, testing and commissioning LT panel board outdoor type of size 1750mm long x 1750mm width x 600mm depth suitable for working on 03 phase, 04 wire, 415 volts, AC, 50Hz cubical and including comprising of following are give below notes of Srl No 20:-
All as per Srl item No 17 here-in-before Supply, install,, testing and commissioning LT panel board outdoor type of size 1400mm long x 1400mm width x 500mm depth suitable for working on 03 phase, 04 wire, 415 volts, AC, 50Hz cubical and including comprising of following are give below notes of Srl No 22:-
M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 400 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed. Note applicable for Srl item No 23 to 34 here-in-after:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately.
All as per item No. 23.00 here-in-before but cross-sectional area 300 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 240 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 185 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 120 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 95 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 25 sqmm, 4 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 16 sqmm, 4 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 16 sqmm, 2 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 10 sqmm, 2 core complete.
All as per item No. 23.00 here-in-before but cross-sectional area 6 sqmm, 2 core complete.
S&F GI bracket pipe of size 40 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate MS flat iron clamps of (30X6)mm thick -02 Nos suitable for fixing any place of poles with nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed.
S&F LED secruity light fitting of capacity 70 to 75 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed. (Make: Jaquar Item Code: LSRTO1S072XW / Crompton cat ref No.LSTP-72-CDL/Eveready Cat No. LEDSL072I5-02 / Century LED (Magik) product code: SPOR072W /Halonix Cat No.HLSLD-10-72-CWL-I as approved by GE.)
S&F LED street light fitting of capacity 90 Watt in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing including taking down existing old unserviceable light fittings complete all as specified and directed. (Make: Crompton cat ref No.LSTP-90-CDL/Halonix Cat No.HLSLD-10-90-CWL-I / Century LED (Magik) product code: SPOR090W / HPL Product Code: HPLLEDSL9060S as approved by GE.)
S&F LED post top lantern 40 watts made in cast aluminium spigot housing with decirative opal polycarbonate diffser and IP65 protection and providing suitable fixing arrangements such as lugs, glands, nuts, bolts and washers including taking down existing old unserviceable light fittings complete all as specified and directed. (Make: Century LED (Magik) product code: APBY040C /Bajaj Cat No. BGCL 40 W LED WH /Halonix Cat No. HLPT-04-40-CW / HPL Product Code: HPLLEDPCR40W as approved by GE.).
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr below the road surface) with the help of GI tubing of dia not exc 100mm for passing of UG cable all as specified and as directed.
M&L PCC (1:4:8) type D-2 (using 40mm graded aggregates) as in foundation for stay set /pole etc, filling and mass concrete including necessary formwork, as required, complete all as specified and as directed.
M&L PCC (1:2:4) type B-1 (using 20 mm graded stone aggregates) as in coping around pole etc including necessary form work, finished even and smooth without using extra cement complete as specified and directed.
Supply and filling sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified in SSR Pt-I and as directed. (Note : Punned thickness will be measured for payment.)
M&L for earth continuity conductor or main earthing lead, 8 mm dia galvanised iron wire, laid in trenches alongwith the under ground cable, earth conectivity upto each pole looping box earth terminal, buried in ground or fixed to poles or any other location, as directed, drawn in and including PVC conduit, medium grade, 15 mm dia, for loop earthing etc, including taking down and removing old unserviceable earth wire complete all as specified and directed. Note:- Rate of required length of PVC Conduit 15mm medium grade pipe shall be included in the quoted rate.
Excavation in trenches not exc 1.50 m wide and n exc 1.50 mtr in depth; for foundation etc. not exc 10 sqm on plan and getting out in soft/loose soil etc complete all as directed.
Excavation in trenches not exc 1.50 m wide, exc 1.50m depth and n exc 03 mtr in depth; for foundation etc. not exc 10 sqm on plan and getting out in soft/loose soil etc complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil etc complete all as specified and as directed.
Removing excavated materials (soils) to a distance not exc. 50 mtr and depositing where directed at level not exc 1.5 m above the starting point etc complete all as specified and as directed.
Supply and laying bricks burnt clay bricks sub class 'B' for cable of size (250 x 125 x 75)mm for protection under ground cable complete all as specified and directed
Supply and laying un-reinforced precast concrete cable cover, class LV, type I, flat, size 250mm x 150mm x 40mm for protection of cable complete all as specified and directed.
M&L for GI pipe 80 mm dia "light grade" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed .
All as per Srl item No 50 here-in-before but 50mm dia
All as per Srl item No 50 here-in-before but 40mm dia
NC BOSE AND CO
MAZUMDER AND CO
JAGATRAM CONSTRUCTION
S S ENTERPRISE
JADAV CONSTRUCTION
M/S. CHAKRABORTY ENTERPRISE
S.M. ISHAQUE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .