| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.0 L+₹1.8 L (8.34%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹24.7 L+₹3.5 L (16.3%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹25.0 L+₹3.8 L (17.8%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹33.2 L+₹12.0 L (56.5%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 May 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-03-2020-21 REPAIRS / MAINTENANCE OF INTERNAL WIRING IN BLAST PENS, CEILING / EXHAUST FANS AND CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREAS AT AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_338203_1
GE AF/AMB-03/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE AF AMBALA
₹60,000
Yes
24 Jun 2020
9 Apr 2020
18 May 2020
9 Apr 2020
16 May 2020
24 Apr 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc. not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for plain cement concrete in 1:3:6 (type C-2) using 40mm graded stone aggregates as bed blocks, bed to air termination rods including necessary formwork complete all as specified and as directed
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed
Supplying, fixing / laying steel water tubing, light grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for protection of electric clables including taking out and disposing of old / unserviceable tubings complete all as specified and as directed for the following bores:
Supply, laying, jointing, connecting and testing XLPE insulated, screened, PVC sheathed cable 1100V (earthed) grade, screwed PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor laid in trenches, etc. including taking out old unserviceable cable, brick covers from any location and disposing off complete all as specified and as directed of the following sizes: Note: Excavation and earthwork will be measured and paid separately under respective item herein
3.5 core 50sqmm
4 core 16sqmm
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for cutting into roads / paths / hard standing, concrete / tiled / bituminous, etc. for insertion of GI protection / passing through pipes 50mm bore at any length at any location including making good the disturbed surfaces after laying of pipes complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink joint indoor type with jointing material and accessories suitable for 4 core, 25 to 50mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
M&L for cable jointing kit for 1.1kV earthed grade cable for end termination heat shrink joint indoor type with jointing material and accessories suitable for 4 core, 70 to 120mm², XLPE insulated armoured aluminium conductor cable including taking out and disposing off old joint complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V TPN 4 way double door, surface on walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V SPN 8 way double door, surface on walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V SPN 12 way double door, surface on walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs sheet metal enclosures for MCB distribution board 230V SPN 2 way double door, surface on walls, etc. with 200Amps rated busbar with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs sheet metal enclosures 4 way for MCCB incomer, 12 module outgoings, vertical type, TPN load line distribution board suitable for mounting MCCB 100A as incomer, double door, IP 43 protection class, conforming to IS 8623-III, with 160A rated bus bar, blanking plates, duly flushed in wall and making good the disturbed surfaces with and including necessary thimbles, plugs, nuts, bolts, etc. complete all as specified and as directed
S&F in repairs MCB TPN 63A 415V 50Hz 10kA complete all as specified and as directed
S&F in repairs MCB SPN 6 to 32A 240V 50Hz B curve 10kA complete all as specified and as directed
S&F in repairs MCB SP 6 to 32A 240V 50Hz B curve 10kA complete all as specified and as directed
S&F in repairs MCCB 4P 100A 16kA 50Hz with adjustable thermal release fixed magnetic protection complete all as specified and as directed
S&F industrial metal clad socket outlet with single pole and neutral enclosure with 5 pin and earth plug socket 8 module, 32A, IP-54 protection class, including 1No. MCB 4P 32A 10kA and taking down and disposing off old/unserviceable socket complete all as specified and as directed
Supply, installation, testing & commissioning of powder coated compartmentalized cubical LT feeder pillar box / panel, of suitable size, symetrical with overload, short circuit and earth fault protection, having bus bar chambers with 150A rated aluminium bus bar, duly insulated with coloured PVC sleeves as per standard code, rigidly mounted on bakelite / DMC insulators (square / round with good insulation resistance), fabricated out of 3.15mm thick CRCA sheet steel, totally enclosed, dust proof, weather proof, vermin proof, double door with suitable locking arrangements and suitable for operation on 240V, 50Hz, 1 phase, 2 wire AC supply with gland plates, cable glands, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables, mounted/fixed on and including MS angle iron stand /frame 40cm height from FFL, fabricated out of 50x50x6mm thick MS angle legs (4Nos.) duly grouted in and including 100mm thick PCC 1:3:6 platform of suitable size (with 0.5m offset to all sides of panel/feeder), painting all exposed metal surfaces with two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer with, accommodating and including the under mentioned and connecting up and taking down and disposing off old panel complete all as specified and as directed (i) MCCB three phase adjustable type with thermal magnetic release 100A 25kA FP - 1No. (ii) MCCB three phase adjustable type with thermal magnetic release 63A 16kA TP - 3Nos. (iii) Digital ampere meter and voltmeter (iv) Indicator lamp RYB - 1No.
M&L for carrying out repairs / maintenance of existing LT panels at any position / location and of any size, by disconnecting connections, etc. cleaning the entire compartments, arranging cables in proper manner, changing burnt lugs by providing new lugs, thimbles, etc., taping with insulated tapes of all naked cable joints/ends, preparation of old treated surfaces and applying one coat of grey synthetic enamel paint including all necessary welding works to reinstate broken / damaged doors, hinges, supports, legs, etc. and cleaning the surrounding upto 2m all around complete all as specified and as directed
Supplying, fixing / laying in repairs PVC insulated aluminium conductor cable, 2 core 10sqmm, flat, solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in service connections suspended by and including insulated hangers not more than 1.0m c/c and 4mm suspension wire complete all as specified and as directed
S&F in repairs security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.2m long fixed with including flat iron clamp made of FI 25x3mm, nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint over a coat of red oride zinc chrome primer complete all as specfied and as directed
M&L for test point terminal block made of gun metal phosphorus bronze, size 75x75x25mm, drilled and screwed with sheet metal enclosure of size 100x100x100mm fabricated out of steel sheet not less than 1.6mm thick and including 3Nos. 8mm dia 25mm long hexagonal head screws, taking down and siposing off old unserviceable block complete all as specified and as directed
S&F in repairs air termination, single pointed aluminium rod 12mm dia and 300mm long including suitable insulated base plate and connecting up complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
One bell point controlled by one bell push
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sheet (1.6mm thick) sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover for 3 pin 15Amps switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 2 runs of 4sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories surface on walls / roofs / floors / ceiling etc. and including provision of 2.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly, including cutting chases for conduit and sinking for box and making good to the surface to match the existing and MS sunken box or pressed steel terminal boxes with provision of 3mm thick plastic laminated sheet top cover complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, surface on walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15Amps switch socket power point on independent board complete all as specified and as directed
M&L for point wiring with 2 runs of 4sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through and including non-metallic rigid PVC conduit not less than 20mm dia and conduit accessories, concealed in walls / roofs / floors / ceiling etc. and PVC insulated heavy duty, ISI marked, unsheathed copper conductor 2.5sqmm for earth continuity conductor and connected to common earth dolly for power points on independent board complete all as specified and as directed
M&L for point wiring with 1.5sqmm, single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100volts grade with multi-stranded copper conductor, drawn through existing non-metallic rigid PVC conduit concealed on walls, ceiling etc., and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly and drawing out and disposing off old damaged existing cables complete all as specified and as directed for the following:
One light / ceiling fan / exhaust fan point controlled by one 6A one way switch
One switch socket outlet 3 pin 6Amps on independent board
One switch socket outlet 3 pin 5Amps on same board
M&L for point wiring with 2 runs of 2.5sqmm, single core PVC FRLS insulated, heavy duty, ISI marked, unsheathed cable 1100volts grade with multistranded copper conductor drawn through existing PVC conduit, concealed type with PVC insulated heavy duty, ISI marked, unsheathed copper conductor 1.5sqmm for earth continuity conductor and connected to common earth dolly for 3 pin 15Amps switch socket power point including drawing out and disposing off old damaged existing cables complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 5amps, 230V complete all as specified and as directed
S&F switch piano flush modular type, single pole, ISI marked, one way 15amps, 230V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 6amps modular type, ISI marked, 230V complete all as specified and as directed
S&F socket outlet, multi-purpose, 3 pin, 16Amps, and 1 pin 6Amps, modular type, ISI marked, 230V controlled by one switch complete all as specified and as directed
S&F electronic fan regulator, stepped modular type (5 steps), 120W, 50Hz, 230V, ISI marked with cover plate duly connected up complete all as specified and as directed
S&F electronic fan regulator, stepped type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed
S&F modular white cover plate with frame ISI marked complete all as specified and as directed suitable for the following:
2 modules
3 modules
4 modules
6 modules
8 modules
S&F modular metal flush box ISI marked complete all as specified and as directed suitable for the following:
2 modules
3 modules
4 modules
6 modules
8 modules
S&F switch piano flush button type, single pole, ISI marked, one way 5amps, 240V complete all as specified and as directed
S&F switch piano flush button type, single pole, ISI marked, one way 15amps, 240V complete all as specified and as directed
S&F socket outlet, 3 pin, multipurpose 5amps flush type, ISI marked, 240V complete all as specified and as directed
S&F socket outlet, 2 in 1, 3 pin, multipurpose 15amps flush type, ISI marked, 240V complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed
S&F PVC lamp holder, insulated body, bracket holder / angle holder 240V complete all as specified and as directed
S&F bell push flush button type, 5Amps, 240V complete all as specified and as directed
S&F in repairs LED tube light fitting 1x18W, 230V, PF 0.9, CRI> 70, L 70, in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tubelight with high efficient LED in aluminium housing with clear & milky diffuser with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
S&F in repairs indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.9, CRI> 70, L 70 and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
S&F in repairs recess/surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36W, PF 0.9, CRI> 70, L 70 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
S&F in repairs LED bulk head 10W with pressure die cast aluminium housing high efficient LEDs and enclosed with milky diffuser IP 66 protection, PF 0.9 , CRI> 70, L 70 with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
S&F in repairs LED flood light 70W with high power discreet LED, PDC housing and integral driver with IP 65 protection galaxy-I type with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
S&F in repairs LED security light luminaire IP 66, CRI>70, PF > 0.9, lumens minimum 90lux/watt, aero-dynamically designed with better thermal management 90W complete all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conducter cable of size 4sqmm and 1 run of 2.5sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 20mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 2 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conducter cable of size 10sqmm and 1 run of 6sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 25mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
M&L for submain wring using proper colour coding with 4 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100volt, multistranded, copper conducter cable of size 6sqmm and 2 runs of 4sqmm multistranded, copper conductor cable 1100volts green colour for earth conductor drawn through and including PVC conduit 32mm bore, heavy duty, ISI marked fixed on wall/ceiling, etc. with all required accessories including taking down old sub-main wiring any type complete all as specified and as directed
Notes for item Nos. 81 to 84: (i) 2/4 runs of 4/6/10sqmm main cable, 1/2 runs of earth conductors and 1 run of PVC conduit as per item shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of conduit as per requirement at site
S&F in repairs recess mounting LED down light 15W with all accessories pre-wired including connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old unserviceable light fittings complete all as specified and as directed
S&F in repairs recess mounting low height backlit round LED down light 18W with all accessories pre-wired including connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old unserviceable light fittings complete all as specified and as directed
S&F in repairs recess mounting low height backlit square LED down light 6W with all accessories pre-wired including connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old unserviceable light fittings complete all as specified and as directed
S&F in repairs LED post top lantern 36/40W made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP 65 protection of 36/40 watt with all accessories pre-wired including connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old unserviceable light fittings complete all as specified and as directed
Supplying, installation and testing water proof fountain light 23W (in combination of 06Nos LED bulb) of approved design suitable for fixing to 40mm pipe with suitable driver, with all accessories pre-wired including connecting with twin core twisted flexible copper conductor cable and taking down and disposing off old unserviceable light fittings complete all as specified and as directed
S&F driver 230V suitable for 45/60/90/120W LED street lights of existing make and type complete all as specified and as directed
S&F driver suitable for LED strip of 1/3/5W of existing make and type complete all as specified and as directed
S&F LED strip 1W flexible type warm white in colour 10mm width of approved deisgn, make and type complete all as specified and as directed
M&L for taking down old street light / security light / high mast light / guard post light fittings and refixing after necessary repairs including all necessary staging, etc. for cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing and dead bulb / tube rod, worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: Minor parts, bulb/tube rod shall be measured and paid separately under respective items herein
Supply only open construction ballast 150W suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only open construction ballast 250W luminaire type suitable for HPSV/MH fitting, 220/240V, 50Hz complete all as specified and as directed
Supply only ignitors for 70 to 250W suitable for HPSV lamps, 240V, 50Hz complete all as specified and as directed
Supply only capacitors 20MFD + 5%, 240V, AC, 50Hz complete all as specified and as directed
Supply only capacitors 33MFD + 5%, 240V, AC, 50Hz complete all as specified and as directed
Supply only HPSV lamp 150W tubular, 240V complete all as specified and as directed
Supply only HPSV lamp 250W tubular, 240V complete all as specified and as directed
Supply only MH lamp 150W tubular, 240V complete all as specified and as directed
Supply only MH lamp 250W tubular, 240V complete all as specified and as directed
Supply only lamp holder suitable for 70/150/250W HPSV/MH lamp, 240V 50Hz complete all as specified and as directed
Taking down carefully exhaust fans (with or without louvers), any type, from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed of the following sizes: Note: Replaced minor spares shall be meaured and paid under respective items herein
Taking down carefully ceiling fans, 1200/1400mm sweep from any position / location, dismantling blades, taking out unserviceable / damaged minor components, etc. and replacing same with new parts, cleaning the fans, greasing moving parts, replacing rubber reel, split pins, check nuts, PVC connectors, etc. refixing the fan in position by providing nuts / bolts as required, replacing old worn out connecting cable with 3core 1.5sqmm, 1.5m long from fan to ceiling rose, testing fans for workability and cleaning off the premises complete all as specified and as directed Note: Replaced minor spares shall be meaured and paid under respective items herein
Supply only PVC 3 core chord, flexible copper insulated cable 24/0.2mm size black/grey in colour and fixed / laid complete all as specified and as directed
Supply only condenser 2.5/3.5/4MFD for ceiling fans / exhaust fans complete all as specified and as directed
Supply only gun metal bushes of existing sizes suitable for ceiling fans / exhaust fans complete all as specified and as directed
Supply only ball bearing of existing size suitable for 1200/1400 ceiling fans complete all as specified and as directed
Supply only ball bearing of existing size suitable for 300/380/400mm exhaust fans complete all as specified and as directed
Supply only fan blades of existing size, type suitable for 1200/1400 ceiling fans of approved design complete all as specified and as directed
Supply only MS clamps for hanging ceiling fan with providing new nuts, checknuts and 2Nos. bolts 2" x 3/8" and rubber rings (reel)
Supply only down rod of 20mm GI tubing, medium grade for extension rod not exceeding 600mm in length each for ceiling fans including all necessary cutting, threading and drilling holes, etc.
Supply only louvers made of GI sheet, 3mm thick suitable for 450mm sweep exhaust fans
Supply only louvers made of GI sheet, 3mm thick suitable for 230/300mm sweep exhaust fans
M&L for removing old worn out paint from fan and blades of ceiling / exhaust fans by rubbing with suitable emery paper, etc. and spray painting with two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer and writing MES number of fans (tint as approved and suitable sized font) in body of fan and cleaning off the premises complete all as specified and as directed
M&L for taking out burnt winding of exhaust fans of size 230 / 300mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of exhaust fans of size 400/450mm carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
M&L for taking out burnt winding of ceiling fans of size 1200/1400mm sweep carefully without damaging the stator and rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning complete all as specified and as directed
S&F PVC body air freshner / diffuser 220/230mm sweep, single phase, 230V with lovers and fixing arrangements of approved design and type including taking down and disposing off old diffuser complete all as specified and as directed
S&F check valve, brass of size 15/25/32mm dia suitable for pressure pump of capacity 0.5 -1.0HP as per existing including taking down and disposing off old valve complete all as specified and as directed
S&F auto-cut pressure release valve suitable for pressure pump of capacity 0.5 -1.0HP as per existing including taking down and disposing off old valve complete all as specified and as directed
M&L for dismantling and taking out pressure pump of capacity 0.5 -1.0HP at any location, carting to reputed workshop and rewinding the pressure pump with the same gauge and number of winding of copper wire and replacing as required unserviceable spares parts like bushes, shafts, fasteners, bearings, capacitors for making the same functional including reinstalling / refixing the pump after repairs in its original position complete all as specified and as directed Note: Quoted rate shall be deemed to be inclusive of any minor spares / parts replaced for successful functionality of the pump
S&F in repairs GI strip of size 25x4mm with saddles and fixing screws, etc. for roof conductors, down conductors and wall conductors above the ground, etc. complete all as specified and as directed
M&L for earthing using GI earthing strip 32x6mm with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI strip of size 32x6mm extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed
Notes for serial item Nos. 128: (i) The cost of copper / GI earth continuity wire with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge
R N Enterprises
Saurav Enterprises
M/S Sonu Traders
Esha Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .