Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.4 LAdmitted-Finance | -38.70% | ₹17.4 L | L1 | Admitted-Finance |
| 2 | L2₹20.0 LAdmitted-Finance | -29.40% | ₹20.0 L | L2 | Admitted-Finance |
Tender Value
₹28.3 L
EMD Value
₹57,000
Closing Date
11 Mar 2026, 5:00 pmClosed
GM (JAL)
sec.5, Noida
O/M of Sewer line and MSPS/SPS at Expressway (Two Year Lighting Arrangement and other electrical work at IPS-5,6,7,8 and MSPS-2 along RHS Noida Gr. Noida Expressway) Noida
2026_NOIDA_1121437_1
07/SM(JAL-OA)/25-26
Open Tender
Civil Works - Others
730 days
NOIDA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,124
NOIDA
₹57,000
7 Apr 2026
5 Mar 2026
12 Mar 2026
5 Mar 2026
11 Mar 2026
5 Mar 2026
CAPABILITY STATEMENT
* It is compulsory for the bidder to fill this statement and the bidder must upload only those document that support this statement
TENDER REFRENCE No. -07/SM(JAL-OA)/25-26 Select
Name of work : O/M of Sewer line and MSPS/SPS at Expressway (Two Year Lighting Arrangement and other electrical work at IPS-5,6,7,8 and MSPS-2 along RHS Noida Gr. Noida Expressway) Noida Provided
Name of Tenderer Not Provided
TOTAL NIT COST OF PROJECT Excluding Labour Cess (In Rs.) (In lacs) 2832961
S. NO. ELIGIBILITY CRITERIA (Value To Be Filled By the Tenderer In Indian Rs.) Status FINAL STATUS QUALIFIED
1 SOLVENCY (Issued within a period of minimum six months). 40% OF TOTAL ESTIMATED COST NOT QUALIFIED NOT QUALIFIED
2 EXPERIENCE (WITH GOVERNMENT/SEMI- GOVERNEMTN/ PSUs ONLY) completed works during the last 7 years ending last day of the month previous to the one in which applications are invited Three similar completed works each costing not less than the amount equal to 40% of estimated cost put to tender NOT QUALIFIED
Two similar completed works each costing not less than the amount equal to 60% of estimated cost put to tender NOT QUALIFIED NOT QUALIFIED
One similar completed works costing not less than the amount equal to 80% of estimated cost put to tender NOT QUALIFIED NOT QUALIFIED
RESULT OF EXPERIENCE NOT QUALIFIED
3 TRUN OVER DETAIL (DURING THE IMMEDIATE LAST 3 CONSECUTIVE FINANCIAL YEARS) WITH NOATRY) YEAR1
Average annual financial turnover on construction works should be atleast 30% of the estimate cost during the immediate last 3 consecutive financial years.
4 TECHNICAL STAFF ON Rs. 10 AFFIDAVIT (AFFIDAVIT MUST BE BOTH SIDE SCAN IN PDF.) Select
5 TOOLS & MACHINERY ON Rs. 10 AFFIDAVIT (AFFIDAVIT MUST BE BOTH SIDE SCAN IN PDF.) Select
6 Character certificate of Indivisual / Partners / Directors issued from District Magistrate Select
7 AFFIDAVIT OF NOT BLACK LISTED (AFFIDAVIT MUST BE BOTH SIDE SCANE IN PDF.) Select
8 Address Proof/Id. Proof of indivisual/ partners/ directors. Select
9 Filled in from capability Statement Select
10 Certified Copies of relevant pages of following documents Select
a Memorandum and Article of Association showing objectives of the Company/firm and authority to sign the e-Bid/ contract or delegate the power to others for signing the e-Bid/contract. Select
b Place of registration. Select
c The power-of-attorney authorizing the tenderer to singn the e-bid/ contract. Select
d PAN certificate of the company/ firm. Select
e GST registration certificate of the company/firm Select
f Electrical license as per Clause No.124 (Only for Electrical work) Select
11 Notarised Affidavit for No Blood Relation is Noida Authority on Non Judicial Stamp paper of Rs.100/- as per Appendix ‘E’ Select
Note- If tender value is ten lacs and below ten lacs then above condition No. 01, 02 & 03 will not applicable
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: GENERAL MANAGER
Name of Work :-O/M of Sewer line and MSPS/SPS at Expressway (Two Year Lighting Arrangement and other electrical work at IPS-5,6,7,8 and MSPS-2 along RHS Noida Gr. Noida Expressway) Noida
Contract No: 07 /SM-(JAL-OA)/2025-26
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
S/L of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below round level over a cushion of 75 mm. thick sand all around and rotected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq.mm 4 core Mtr. Excess(+) Full Conversion INR
10 sq. mm 4 core Mtr. Excess(+) Full Conversion INR
S/F of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the E/I 70 sq. mm No. Excess(+) Full Conversion INR
120 sq.mm No. Excess(+) Full Conversion INR
Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit concealed in wall, with one number 14 SWG copper earth continuity wire etc., complete in all respects including matching colour wash etc. complete in all respect.wall complete with one number 8 SWG GI earth continuity wire etc.,complete in all respects including matching colour wash etc. complete in all respect. As in item no.1304 (B) but in 20 mm dia heavyduty (2mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire. Mtr. Excess(+) Full Conversion INR
ST Pole 11 Metre. No. Excess(+) Full Conversion INR
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. each Excess(+) Full Conversion INR
S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve Each Excess(+) Full Conversion INR
Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA Nos Excess(+) Full Conversion INR
Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.CAT- AAA Nos. Excess(+) Full Conversion INR
Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. Each Excess(+) Full Conversion INR
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 120 Sqmm Nos Excess(+) Full Conversion INR
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: 120 Sqmm Nos Excess(+) Full Conversion INR
S/F of 11 KV TPMO make complete in all respects as per direction fo E/I Set Excess(+) Full Conversion INR
200 amps. TPN, rising mains in metal enclosure with aluminium busbar including fixing clamp Mtr. Excess(+) Full Conversion INR
Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 140 to 150 Watt. Confirming to IP 66 Protection complete in all respects CAT-AAA No Excess(+) Full Conversion INR
S&F of 800 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of E/I.. 800 Amp. four pole on 50mm x 50mm x 6mm angle iron frame Nos Excess(+) Full Conversion INR
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm Mtr. Excess(+) Full Conversion INR
2 x 2.5 sq. mm Mtr. Excess(+) Full Conversion INR
2 x 4 sq. mm Mtr. Excess(+) Full Conversion INR
S/f following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. ( F-II -40 A TPN) Each Excess(+) Full Conversion INR
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe on surface, complete with 14 SWG copper earth continuity wire,GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed . No Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_2086626.pdf
techsummary_2086626.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
C.xls
Additional Documents • 0.05 MB
BOQ_2086626.xls
BOQ • 0.28 MB
TD.pdf
Tender Documents • 1.18 MB
Download all tender documents and submit your bid