Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC | ₹4.6 Cr | L1 | Accepted-AOC After deducting sch of credit |
| 2 | L2₹4.7 Cr+₹15.2 L (3.33%)Rejected-Finance | ₹4.7 Cr+₹15.2 L (3.33%) | L2 | Rejected-Finance Other than lowest quoted bidder |
| 3 | L3₹4.7 Cr+₹15.4 L (3.38%)Rejected-Finance | ₹4.7 Cr+₹15.4 L (3.38%) | L3 | Rejected-Finance Other than lowest quoted bidder |
| 4 | L4₹4.7 Cr+₹16.8 L (3.69%)Rejected-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹4.7 Cr+₹16.8 L (3.69%) | L4 | Rejected-Finance Other than lowest quoted bidder |
| 5 | L5₹5.1 Cr+₹53.8 L (11.8%)Rejected-Finance | ₹5.1 Cr+₹53.8 L (11.8%) | L5 | Rejected-Finance Other than lowest quoted bidder |
Tender Value
Refer Docs
EMD Value
₹3.9 L
Closing Date
10 Mar 2021, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
HQ Chief Engineer Navy Station Road Visakhapatnam 530004
PROVISION OF DEFICIENT GYMNASIUM AT INS KALINGA, BHEEMUNIPATNAM
2018_MES_193440_3
CE NAVY/VIZ/TOKEN/10 OF 2018-19
Open Tender
Civil Works
Lump-sum
365 days
INS Kalinga
As per NIT
9 documents required · 9 mandatory
₹2,000
GE P Navy Kalinga
₹3.9 L
10 Jul 2021
10 Feb 2021
11 Mar 2021
10 Feb 2021
10 Mar 2021
24 Feb 2021
Amount
Phase-I
Lumpsum price worked out by the contractor for "Buildings and Structures", for the Lumpsum price of Rs. 2,13,50,000.00 inserted by MES as listed in Schedule "A" Part – I on Serial Page No. 34
Lumpsum price worked out by the contractor for " [SITE CLEARANCE/AREA DEVELOPMENT/EARTH WORK EXCAVATION]", for the Lumpsum price of Rs. 15,40,451.85 inserted by MES as listed in Schedule "A" Part – II on Serial Page No. 35
Lumpsum price worked out by the contractor for " INTERNAL WATER SUPPLY", for the Lumpsum price of Rs. 51,030.20 inserted by MES as listed in Schedule "A" Part – III on Serial Page No. 36
Lumpsum price worked out by the contractor for "[INTERNAL ELECTRIC SUPPLY ]", for the Lumpsum price of Rs. 1,28,522.50 inserted by MES as listed in Schedule "A" Part – IV on Serial Page No. 39
Lumpsum price worked out by the contractor for "[EXTERNAL WATER SUPPLY]", for the Lumpsum price of Rs. 45,422.20 inserted by MES as listed in Schedule "A" Part – V on Serial Page No. 40
Lumpsum price worked out by the contractor for " [EXTERNAL ELECTRIC SUPPLY]", for the Lumpsum price of Rs. 3,40,300.69 inserted by MES as listed in Schedule "A" Part – VI on Serial Page No.41
Lumpsum price worked out by the contractor for "[ROAD/PATH/CULVERT AND HARDSTANDING ] ", for the Lumpsum price of Rs. 10,19,247.64 inserted by MES as listed in Schedule "A" Part – VII on Serial Page No.44
Lumpsum price worked out by the contractor for " [SEWAGE DISPOSAL]", for the Lumpsum price of Rs.1,04,983.14 inserted by MES as listed in Schedule "A" Part – VIII on Serial Page No. 46
Lumpsum price worked out by the contractor for "[AREA DRAINAGE]", for the Lumpsum price of Rs.1,92,744.36 inserted by MES as listed in Schedule "A" Part – IX on Serial Page No. 47
Lumpsum price worked out by the contractor for "[RAIN WATER HARVESTING]", for the Lumpsum price of Rs.33,647.36 inserted by MES as listed in Schedule "A" Part – X on Serial Page No. 49
Schedule "A" Part - XI MISCELLANEOUS ITEMS FOR INTERNAL ELECTRIC SUPPLY, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIC SUPPLY, SEWAGE DISPOSAL AND ARBORICULTURE (TO BE QUOTED BY THE TENDERER)
INTERNAL ELECTRIC SUPPLY
Modular switch socket combination 6 Amps 2/3 pin combined,240 volts 3 Module
Modular switch socket combination 15 Amps ,240 volts 3 Module
Submain wiring for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories complete for 2 runs 4.0 Sqmm and 1 runs of 4.0 Sqmm complete and making good the disturbed area. (For Metal Plug Sockets)
Submain wiring for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories complete for 2 runs 6.0 Sqmm and 1 runs of 6.0 Sqmm complete and making good the disturbed area.(For 8 way DB's)
Submain wiring for single phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories complete for 2 runs 2.5 Sqmm and 1 run of 2.5 Sqmm complete and making good the disturbed area. (For Bay light fittings)
Submain wiring for three phase supply with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit of suitable size with accessories complete for 4 runs 6.0 Sqmm and 2 runs of 6.0 Sqmm complete and making good the disturbed area.(For 12 way DB's)
Energy efficient LED light fitting with tube 20 watt or minimum lumen output is not less than 2000 lumens, 230 V, including drive, surface mounted LED batten type with extruded aluminium/ CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified.
LED security light fitting with tube 25W or minimum lumen output is not less than 2500 lumens, New generation energy saving & environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as sourced and HF electronic driver pre wired with 1.5 Sq mm copper conductor cable upto connector including 1.5 Mtr long GI tubing Medium grade 32 mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified and as directed.
Energy efficient LED ceiling light fitting 15 watt, minimum 1500 lumnes output including drive, integral round shape, 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified.
Energy efficient LED mirror light fitting with luminare 10 watt or minimum lumen output is not less than 1000 lumens 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Ceiling fans AC single phase 230 V of size 1200 mm sweep with complete set with fixtures, 5 star rating, ISI marking, metallic body complete all as specefied and directed.
Exhaust fan 300 mm sweep or nearest size, non metallic body, complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed
Wall mounting fan 450 mm sweep or nearest size, metal body (Heavy duty),oscillating with speed control mechanisum with complete with suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed
LED High bay light fitting, robust, IP 65 with luminare 80 watt, minimum lumnes output is not less than 8000 lumens, 230V mounted with necessary diffuser complete with mounting bracket with necessary fitting and fixture etc including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified.
Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC M-10 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm bore GI medium grade earth lead protection pipe connected upto DBs, and suitable C.I top cover with handle, funnel, strainer, charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be included excavation and earth work in any type of soil with PCC type B2 in pad and pit complete all as specefied and directed.
EXTERNAL WATER SUPPLY
Construction of Valve chamber of size 900x 900x 900mm (internal dimentions) including excavation of earth work in any type of soil,100mm thick PCC M-7.5 type D2 as in foundation , made out of 230mm thick brick work in cement mortar 1 :6 with 15mm thick plastering in cement mortar 1:4 internally complete and upto 150mm below ground level for external faces with 100mm thick plain cement concrete M-10 type C1 using 20mm graded aggregate as in coping, cover frame made up of 50x50x6mm and 3.15mm thick MS sheet as cover with two Nos of hinges and one No handle made out of MS round bar 10mm dia with neccssary locking arrangement including finishing the exposed steel sufraces with two coats of synthetic enamel paint over a coat of red oxide primer and two coats of white wash on plastered surfaces complete all as specified.
Cutting existing CI line tubing for alterations or additions necessarily done in position without taking down, dewatering for inserting "TEE" of size 150X150X40 mm dia for branch connection withnecessary CI specials as required at site, etc all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and fix HOT moulded (FRP) junction box for street light pole with locking arrangment with IP 65 protection of size 280 x 200 mm with 16 Amp 4 way heavy duty terminal block with 10 Amp, MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directed.
Supply and commission, testing of LT Panel board CPRI approved outdoor type, 415 Volts, 3 phase 4 wire weather and dust/vermin proof factory made powder coated made out of 3.15mm thick CRCA sheet pedestal type, total enclosed with front and rear opening door with necessary hinged doors with projected an raised suitable platform size necessaray locking arrangements along with lugs, cable glands of various sizes for cable, danger notice plate, strickering of switcher gear and the nut/bolts etc., used are to be made of rust proof meterial including as per IS: 8623 Aluminium bus bar of 300 Amps rating with heat proof colour cade, insulations suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and bedded in suitable size PCC M-15 type B1 platform complete all as specified with and including the following:-
i) INCOMMING: LT 415 volts 3 phase, 4 wire 50 cycles, 25 KA, Adjustable type MCCB of 125 Amp rated complete with over load protection, no-volt thermal based release. ii) OUTGOING: LT 415 volts 3 phase, 4 wire 50 cycles, 16 KA, Adjustable type MCCB of 100 Amp rated complete with over load protection, no-volt thermal based release-01 No (Gymnasium)
Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to using galvanised iron earth iron stip 32x6 mm as earthing lead by means of bolts and nuts check nuts and washers of galvanised iron or steel all as specified and shown in electrical plate No 3 of SSR Part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC M-10 type C1 chamber with CI Cover of 10 mm thick with MS rod 6 mm dia 150 mm long reinforcement, watering funnel with 20 mm dia medium grade for watering and for protection of earth electrode 50 mm dia GI Pipe all a specified and directed and tested on completion.
LED Street light fitting luminaire 45 Watts, compreising of epoxy powder coated, pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing complete all as specified .
Temper proof Three phase static enegy meter (KWH) of accuray class 1.0, 3 X 240 volts, 50 HZ with Backlite LCD display of rating 10-60 A complete all as specified and directed
Sheet metal encloser dust and vermin proof cubical type made out of 2mm thick MS sheet mounting on walls, locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer for fixing of MCB DB, energy meter, space for repairs, drilling holes for incomoing and out going cables etc and making good the distrubed area complete all a specified.
SEWAGE DISPOSAL
Under ground drainage double wall corrugated HDPE pipe 150 mm dia SN 4 confirming to IS: 16098(Part II) single socketed in any length laid in trenches or floors etc all as specified.
ARBORICULTURE
Supply only approved best quality red soil/earth without containing moorum and having suitable PH & EC as recommended by the saline water scheme and manure mixing in the ratio of 3:1 {03 parts soil & 01 part mixture of manure such as vermi compost, polydol dust, neem cake,DAP,Novacron and organic manure( cow dung) etc} all as specified and as directed by the Engineer-In-Charge. Note 1:- Red soil well seived 90% to pass through IS Seive of 10 mm size free from stone rubbish like lurops, stones and other foreigh materials, suitable for gardening. The soil should be fresh from quarry. The colour of the soil generally be red and the cost including of all royallity and carriage, all T&P, taxes, actroi etc all complete as specified, directed and approved by Engineer-in-Charge. 2:- Manure shall be well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material,. The colour of manure shall be black, the manure screened through seive at 1.5 designation 4.75 micron including carrige at site. 3:- The soil shall be stacked neatly on level ground.
PLANTATION
Supply, transport and Plantation of the following saplings for plants at site including excavation in post hole(similar holes) each n.exc 0.5 Cum (Minimum 0.5X0.5m size) in any type of soil and refilling the trench after plantation with approved red soil with manure. Note:- Supply only red soil with manure shall be measured and paid seperately. However, labour orient for filling deemed to be included.
Border plants(Golden Durantv) pack size 8", ht 3 to 4 feet
Mango(Hybrid) pack size 8", ht 3 to 4 feet
Coconut tree package size 8" ht 3 to 4 feet
Ufarbia Ned package size 8" ht 3 to 4 feet
GRASS
Best quality Korean grass carpet by piece turfing including preparation of earth and covering with red earth organic manure, farm yard manure and neem cake, polidal complete all as directed by Engineer-in-Charge. Note:-(i) Supply only red soil with manure given shall be measured and paid seperately. However, labour orient for filling and rolling with hand/ mechanical roller deemed to be included.
MAINTENANCE OF ARBORICULTURE [Phase-II ] [Schedule "A" Part – XII]:
Maintenance and supervision of trees, plants, shrubs, grass etc as specified in particular specification, as directed by Engineer-In-Charge and as recommended by Horticulture including spreading of pesticides, insecticides in the desired periodicity, weeding, watering etc from the certified date of completion of Phase-I work.
Note: (i) The unit rate deemed to be included all labour, materials, tools and plants and regular watering using necessary sprinklers, including supply and spreading/ spraying organic manure, chemical fertilisers, pesticides, garden soil (red soil with manure) to the required extent complete all as specified and as directed by the Engineer-In-Charge.
(ii) Water for arboriculture and maintenance will not be issued by the department. However, water for arboriculture including maintenance shall be utilised from STP treated water sump without any extra cost. Necessary transport/ tools and plants and make his own arrangements for storing the water required at his own expense.
(iii) The arboriculture maintenance work shall be carried out by the experienced staff and with atleast 02 No’s of semi skilled gardeners per day throughout the maintenance period of 12 months for the entire work of Arboriculture, spread various pockets as shown in the site plan and as directed by Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .