| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹21.3 L+₹6.0 L (39.0%)Rejected-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹22.0 L+₹6.7 L (43.9%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹23.4 L+₹8.1 L (53.1%)Rejected-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹23.7 L+₹8.4 L (55.0%)Rejected-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
9 Mar 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
REPAIR TO OH LINE, UG CABLE AND PANEL BOARD WITH CONNECTION WORK UNDER GE RAMGARH
2023_MES_578135_1
8300/3154/E8
Open Tender
Civil Works
Item Rate
270 days
GE RAMGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH
₹50,000
Yes
27 Apr 2023
31 Jan 2023
11 Mar 2023
31 Jan 2023
9 Mar 2023
23 Feb 2023
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
M&L Sand filling in cable trenches for cable protection with clean dry sand unwashed incuding gently punning in a layer of 15 Cm and 8 Cm (total 23 CM) in thickness all across the laid portion of LT Cable in trenches complete all as specified and directed. Note :- Punned thickness shall only be considered for payment
Supplying and laying old size sub class “B” bricks kiln brunt, neatly laid adjacent to each other with axis of bricks perpendicular to the axis of cable for cable protection complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in bed plates and copings including necessary form work complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling, base & mass concrete etc complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete etc complete all as specified and directed.
M & L for brickwork using old size well burnt brick with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 120 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4.0 coreincluding taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 4.0 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 2.0 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 10 Sq mm 2.0 core including taking down old unserveciable cable complete all as specified and directed.
Supplying and fixing as in replacement MCCB Tfour pole 63 amps 415 volt , 50 Hz breaking capacity not less than 16 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 100 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 125 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 160 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 200 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 250 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 400 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Dismentling old and unserveciable stay assembly complete comprising of stay clamp, stay wire, stay insulator, stay grip, thimble, bow, stay rod 16 mm dia and stay plate etc including breaking of cement concrete complete all as specified and as directed.
M&L for stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps excavation and concrete measured separately), stay rod of size 20mm dia complete all specified and directed .
Supply and fixing in repairs loop type insulators, vitreous porcelain, white, brown or greeen of large size, with overall dimensions 90 mm X 140 mm, clearance of hole 25.5 mm complete all as specified and directed. Make: Bengal Potteries/ Jayashree/ Mysore Porcelain/ Jaipuria/ Bhel/ Southern Insulators/ WS Insulators.
Dismantling old and unserveciable prestressed concrete poles/steel tublar poles of any type including breaking cement concrete complete all as specified and directed.
Supply, erecting in position steel tubular swaged pole (410 SP-37), 9.50 Mtr long confirming to IS-2713 complete with cast iron base plate, finial taper plug, pole cap, bolts, nuts, screws and washers, welded and reduced section and longitudinal weld throughout entire length of pole including two coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint including above GL and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / coping and writing pole numbers with bold letters with black and white paint after painting complete all as specific and as directed. (Note: Excavation and earth work and PCC in foundation shall be measured and paid separately)
M&L for painting to existing steel tubular/concrete LT poles, 8.5m/9m/9.5m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality dust proof and weather proof of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers with bold letters with black and white paint after painting complete all as specific and as directed.
Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Dismantling and removal of ACSR conductor any size from the pole and labour for restringing the same with insulator including replacementt of binding wire, aluminium jumper, etc chopping of trees branches (coming in the way/line) complete all as directed by Engr-in-Charge. Note : The unit rate quoted by bidder is deemed to be included the T&P cost like rope manila,ladders etc required at site.
S & F in repair ACSR conductor of (weasel) 6/1 X 2.59mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specific and as directed.
M & L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specific and as directed.
S & F in repair Aluminium thimbles of size 16 Sq mm to 35 Sqmm of 3.5/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair Aluminium thimbles of size 50 Sq mm to 95 Sqmm of 3.5/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair Aluminium thimbles of size 120 Sq mm to 185 Sqmm of 3.5/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
M & L shackle type porcelain, vitreous, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors, working pressure 1100 volts insulator 65 mm dia X 31 mm high X 20mm hole ball and socket type working pressure 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
Material and labour for Fibre LT over head line seperators suitable for 4 wires fixing on LT OH lines including dismantling of old damaged/ un-serviceable LT line spacers of any type complete all as specified and directed.
Material and labour for Fibre LT over head line seperators suitable for 2 wires fixing on LT OH lines including dismantling of old damaged/ un-serviceable LT line spacers of any typecomplete all as specified and directed.
Supply and fix in replacementt of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size 20 cm x 15cm for LT complele all as specified and as directed.
Cutting branches /plants / bushes obstructing at over head LT/HT lin including cleaning /levelling / cutting of undue surfaces & disposal of materials upto a distance not exceeding 50m complete all as specified and directed by Engineer-in-Charge.
Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth wire of size 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing testing point all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 ,type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm dia bore GI light grade pipe as earth lead protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion includingdismantling/taking down of old unserveciable earthing complete all as specified and directed. Note- Unit rate quoted by bidder deemed to be included excavation and earth work in any type of soil with other arrangement complete all as directed.
Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to LT panel boards all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm dia bore GI light grade as earth strip protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion includingdismantling/taking down of old unserveciable earthing complete all as specified and directed. Note- Unit rate quoted by bidder deemed to be included excavation and earth work in any type of soil with other arrangement complete all as directed.
Supply only 3.15 mm thick mild steel sheet alongwith one coat of red oxide primer with help of spary gun machine complete all as specfied and directed.
Supply only aluminium bus bar of different size and capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacementt (taking down old bus bar) complete all as specified and as directed.
Supply only post top insulators of 3 to 5 cm height for panel boards complete all as specified
Supply only digital Amps meter 0 to 600 Amps capacity 3 phase square type including suitable CT set of 3 old complete all as specified and as directed.
Supply only digital volt meter 3 Phase 415 volt square/round type range 0-500 volt complete all as specified and as directed.
Supply only LED indication Lamp (Red) complete all as specified and as directed.
SSupply only LED indication Lamp (Yellow) complete all as specified and as directed.
Supply only LED indication Lamp (Blue) complete all as specified and as directed.
M & L for removing of damaged steel structure base frame of LT panel board and fabricating new steel structure base frame with size of existing frame equal angle of size 50 mm X 50 mm X 6 mm thick and screwing with existing panel board including two coat of synthetic enamel paint over a coat of red oxide primer with preparation of surface complete all as specified and directed.
Removing wild grass, vegetation, creeper etc aroung LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4.0 core from the pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complte all as specified and directed by Engineer-in Charge. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core from the pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavationin trenches carefully as per standard procedureincluding connecting& testing complte all as specified and directed by Engineer-in Charge. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core from the pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complte all as specified and directed by Engineer-in Charge. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core from the pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting & testing complte all as specified and directed by Engineer-in Charge. (Note: Excavation,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95 Sq mm 3.5 core from the pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavationin trenches carefully as per standard procedureincluding connecting& testing complte all as specified and directed by Engineer-in Charge. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately)
Supply and fix Battery consist of:- (i) Type - VRLA, Sealed maintenance free (ii) Battery Voltage - 12 V DC, nominal (iii) Battery Capacity - Minimum 65 Ah (iv) Terninals - Copper (v) Battery outlet body material - Polypropylene Co-polymer (vi) Battery Charging voltage - 13.5 VDC approx (vii) Battery charging current - Batteries shall be able to accept up to 9 Amp charging current (viii) Life expectancy - 4 years or more, (ix) Compliance of standards -UL 2003 (MH26669), JIS C 8702, IEC 60896 2004, ISO14001:2004 and ISO9901.2000 (x) Test - Shock test (drop test) Large current discharge test, Vent valve function test, Over discharge test, Vibration test, Oven test, Coldproof test, Heat cycle test. Short circuit test (xi) Self discharge rate (max) - within 1% of capacity per week Note: Contractor shall be responsible for installation of batteries, connection of all batteries with UPS with required of suitable size, testing and commissioning at site.
ABHISHEK ENTERPRISES
AASHIRWAD ENTERPRISES
M/S ROHIT CONSTUCTION
M/S Parmar Construction
M/S Akash Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .