Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹2.1 Cr+₹4.8 L (2.33%)Rejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | ₹2.1 Cr+₹4.8 L (2.33%) | L2 | Rejected-Finance Not being L1 |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
10 Mar 2020, 6:00 pmClosed
CHIEF ENGINEER
CHIEF ENGINEER (NW) KATARIBAGH, NAVAL BASE-PO KOCHI-682 004
PROVN OF CERTAIN OFFICERS INLIVING ACCN AT INDIAN NAVAL ACADEMY EZHIMALA
2019_MES_265057_3
890898
Open Tender
Civil Works
Lump-sum
450 days
GE(P) Ezhimala
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE(P) Ezhimala
₹2.3 L
Yes
21 Sept 2020
10 Feb 2020
13 Mar 2020
11 Feb 2020
10 Mar 2020
25 Feb 2020
11 Feb 2020 - 18 Feb 2020
Amount
Total amount of Sch 'A' part-I (Buildings & Works)
Total amount of Sch 'A' part-II ( Excavation/Earthwork & Site Development)
Total amount of Sch 'A' part-III (Internal water supply)
Total amount of Sch 'A' part-IV (Internal Electric Supply)
Total amount of Sch 'A' part-V (Area Drainage)
Total amount of Sch 'A' part-VI (Sewage Disposal)
Total amount of Sch 'A' part-VII (Road,Path and Culvert)
Total amount of Sch 'A' part-VIII (Lightening protection)
Total amount of Sch 'A' part-IX (External Water Supply)
Total amount of Sch 'A' part-X (External Electric Supply)
Sch 'A' Part- XI (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Internal Water Supply:-Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm dia iron pipe and fixed . Make:- Jaquar Code No. OPL-15001 or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Bib Cock, chromium plated, cast copper alloy long body screwed for CPVC pipe 15/16 mm dia bore.Make: Jaquar Code No CON-107 KN or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for CPVC pipe 15/16mm dia bore Make Jaquar code No CON-059KN or equivalent of other make specified in the list of manufacturer complete all as specified and as directed
Concealed stop cock, long body chromium plated, cast copper alloy, screwed down, screwed for iron pipe 15mm dia bore for shower rose Make Jaquar code No CON-069KN or equivalent of other make specified in the list of manufacturer complete all as specified and as directed.
Shower rose chromium plated 125 mm size suiable for 15 mm bore pipe with shower arm
Health faucet with 1.00 Mtr flexible tube in chrome finish, 16 mm outer dia low density polythene, with wall hook , suitable for cold water application complete with union and teflone washers and holder to suit 15 mm angle cock
Internal Electrification:- Concealed Point wiring with PVC insulated unsheathed multistranded single core copper conductor cable ISI marked, 1100 Volt grade, FRLS of size 1.5 sq.mm, through and including rigid non metallic ,ISI marked PVC conduit and all accessories, including suitable size modular metal box,modular white cover plate with frame & 1.5 sqmm PVC insulated unsheathered multistranded single core copper conductor FRLS,ISI marked cable as earth continuity conductor,cutting chasis,and making good disturbed surfaces etc complete all as specified & directed for (a) One light point controlled by one switch Note :(i) Rate include cost of making MS box in concealed for cutting and sinkings for boxes and making good to walls , no extra paymemnet will be made for the same. (ii): Rate include the logic modular plates, necessary blank plates as required at site.
(b) All as per item No.18 here in before but for One ceiling / exhaust fan point controlled by one switch
(c) All as per item No.18 here in before but for One 3 pin 5 Amps socket outlet controlled by one switch independent
(d) All as per item No.18 here in before but for One 3 pin socket outlet 5 Amps controlled by one switch in same board.
All as per item No.18 here in before but with cable size 2.50 sqmm for 3 / 5 pin socket outlet independent, 15/16 Amps / industrial socket for geyser point
All as per item No.18 here in before but one light point controlled with two way switches
All as per item No.18 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size
Fan regulator, 5 step 120W-2 modular 230 Volts,50Hz, ISI marked all as specified and as directed.
Decorative Ultra slim linear 20 W, 4 feet LED lighting fixture including lamp with extruded Aluminium heat sink, environmental friendly, energy efficient prewired with lamp, AC, 230V, ISI marked. Make : Havell's model No. LHEXBHP7PN1W020 or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Indoor wall mounted decorative light fitting 1x7 W LED including lamp.glass body IP-2,colour WW working voltage 140 to 265 volt, body colour white complete including fixing arrangement on wall and connecting. Make :JV Luker model No. LWL 111-1 or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Round shape surface mounted LED luminaire integral high power with dome shape opal diffuse white colour 18 W LED light fitting including lamp complete and connecting. Make :Bajaj model No.BGC ML 18 095 WH or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Decorative Ultra slim linear 9/10 W, 2 feet LED lighting fixture including lamp with extruded Aluminium heat sink, environmental friendly, energy efficient prewired with lamp, AC, 230V, ISI marked. Make : Havell's model No. LHEXBHP7PN1W010 or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Surface mounted Decorative Ultra slim linear 10 W, 1 feet LED (Mirror light) lighting fixture with extruded Aluminium heat sink, environmental friendly, energy efficient prewired with lamp, AC, 230V, ISI marked. Make : Crompton model No.LCL-10-CDL or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Sheet metal enclosure vetical distribution board TPN DB 415 V, AC, 4 way with 200 Amps rated bus bar in 10 KA suitable for MCCB four pole as incomer and MCB SP/TP as outgoing having protection IP 43 protection double door type ISI Marked complete all as specified and directed.
MCCB 4 pole 415 Volts AC, 32- 63 Amps with adjectable thermel magnetic release type,10 KA all as specified and directed.
MCB SP 6 to 32 A, AC, 230V, 10KA complete all as specified and directed.
RCBO double pole (DP) 25 A, 300mA,AC,230V,10KA,ISI marked as per IS 12640-2,IP 20 protected terminal front phase indication for earth leakage fault colour coded ON/OFF indication on dolly .Make:legrand Cat No.411337 or equivalent other make specified in the list of manufacturer complete all as specified and directed.
MCB DP 10 A,AC,230V,10 KA complete all as specified and directed.
Switch modular 32 A,DP -1 way with indicator,2 module complete with modular box and front cover complete all as specified and directed..Make:legrand Cat No.573412 or equivalent other make specified in the list of manufacturer complete all as specified and directed.
Single phase KWH meter 5-30A, 230 V with LCD display in polycarbonate body,class 1 base mounting including all fixing arrangement complete all as specified and as directed.Make:-L&T model no.EM 101 or equivalent other make specified in the list of manufacturer .
KWH meter box fabricated from 2mm thick CRCA sheet double door type of size suitable for fixing KWH meter single phase 5 Nos, control MCB-11 nos complete with cable alley for incoming and outgoing cable,compartment for individual meter with glass at display portion,outer door with locking arrangement including pad lock,powder coated painting and fixing arrangement etc.including LT danger notice plate complete all as specified and as directed.Note:- MCB's and KWH meter shall be measured and paid seperately
KWH meter box fabricated from 2mm thick CRCA sheet double door type of size suitable for fixing KWH meter single phase 4 nos,control MCB-4 nos complete with cable alley for incoming and outgoing cable,compartment for individual meter with glass at display portion,outer door with locking arrangement including pad lock,powder coated painting and fixing arrangement etc.including LT danger notice plate complete all as specified and as directed.Note:- MCB's and KWH meter shall be measured and paid seperately
Ceiling fan,copper wound,1200mm sweep,5 star rating including fixing of down rod of any length suitable from ceiling,canopy,mounting clamp etc.Ac,230 V,and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 1.50 Sq mm from ceiling rose/ connector to fan. Make : specified in the list of manufacturer complete all as specified and directed.Note:-Rate quoted shall deemed to be included for suitable length of down rod from roof to false ceiling as directed by engineer in charge
Exhaust fan electric single phase AC 230 Volts,Copper wound, PVC rust proof body, self opening louvers complete 250mm Sweep ,1300 RPM air delivery not less than 435 cu.mtr/min connect to ceiling rose all as directed. Make : specified in the list of manufacturer complete all as specified and directed.
Submain wiring with 4 sq mm wire three single core (for phase and neutral and earth) using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed PVC conduit of dia not less than 20 mm with and including PVC conduit and accessories complete for 8 way DB Note:- Three runs of 4 sqmm wire and one run of PVC concealed conduit shall be measured as one run only.
Submain wiring with 6 sq mm wire three single core (for phase and neutral and earth) using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed PVC conduit of dia not less than 20 mm with and including PVC conduit and accessories complete for 12 way DB Note: -Three runs of 6 sqmm wire and one run of PVC concealed conduit shall be measured as one run only.
External Water Supply:- Cutting of CI tubing 80 mm dia for alterations or additions,80x80x80mm CI Tee,CI collar for tapping including necessary excavation and making good the surface complete all as specified and as directed.
Construction of brick masonary with CM 1:6 valve pit chambers including 100mm thick PCC in foundation 1:5:10 type E2, 10 cm thick rendering cement plaster internaly 10 mm thick and with cement mortar 1:4 PCC,1:2:4 type B1 using 20 mm graded aggregate for coping 10 cm thick height, 3 mm thick MS plate cover with locking arrangement and angle frame of size 40x40x6 mm including painting to plate cover with synthetic enammeled black paint over one coat of red oxide primer including neceessary excavation and earth work for valve chamber of size 900x900x900mm all as shown on DD/TD/119 sheet 1/1.
External Electric Supply :- Supply, lay and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4core.
Supply, lay and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4core for street light.
Steel tubular swaged poles type 410 SP-22 (8.5 metre long) conforming to IS ,Swan neck type complete with cast iron base plate, final taper plug, bolts, nuts and washers and single swan neck, including painting with three coats of bitumen paint internally complete and externally for the portion embedded in concrete and two coats of aluminium paint over a coat of red oxide primer to the balance portion of external surface complete all as specified and as directed. Note:- Excavation and PCC shall be measured and paid seperately under relevant item of schedule 'A' foundation and coping
Earthing completely with galvanised iron earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounded from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 40 mm dia as protection pipe for GI strip 32x6mm as earth lead upto 7.5 Mtr connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil all as directed and shown in electricall plate No. 3 of SSR Part-I including testing on completion.
Earthing completely with galvanised iron earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground to a depth not less than 2.25m below ground level with top edge of the earth plate at a depth not less than 1.5m below normal ground level surrounded from all side by 15 cm of thick and packed layers of charcoal dust and common salt ,filling alternate layers and electorde connected by using (max -length of 7.5 mtrs )by means of bolts,nut and washer of GI and providing GI light grade pipe 15 mm dia as protection pipe for GI wire 4mm dia as earth lead upto 7.5 Mtr connected main controll board / test point and provided with GI pipe of light grade 20 mm bore for watering and including funnel,wire mesh PCC chamber of 1;3;6 type C1 ,and RCC cover of 1;2;4 type B1 including necessary earth work in any type of soil /strata disposal of soil all as directed and shown in electricall plate No. 3 of SSR Part-I including testing on completion.
Modification of existing LT panel with and including MCCB , TPN,100A, 25KA, 415 V with sheet metal enclosure made of 3mm CRCA sheet with angle iron frame 50x50x6mm suitable height to match with existing LT panel including PCC foundation etc complete all as specified and as directed.
LED street light fitting 45 W die cast aluminium housing 5KV surge protection, power factor 0.95 THD less than 10%, IP65 protection and heat resisitant toughened glass with frame including all accessories and suitable bracket made out of GI pipe medium grade of dia 40 mm and length 1.6m bend in shape including mounting with 7 PVC cable 2.5Sqmm three core including termination and connecting wih flexible copper wires etc and tesing on completion all as specified and directed. Make:CG model No LSTN-72-CDL-1 or equivalent other make specified in list of manufacturers.
Building security light fitting for use of front and rear side 45 W die cast aluminium housing 5KV surge protection, power factor 0.95 THD less than 10%, IP65 protection and heat resisitant toughened glass with frame including all accessories and suitable bracket made out of GI pipe medium grade of dia 40 mm and length 2M bend in shape including mounting clamps connections with multicore round 3 core 1.5 Sqmm copper conductor flexible cable 1100 Volts including termination and connecting wih flexible copper wires etc and tesing on completion all as specified and directed. Make:CG model No LSTN-72-CDL-1 or equivalent other make specified in list of manufacturers.
Hot water Supply:- Supply install and testing Stationery storage type electric water heater with BEE 5 star rating,230 Volts,50 Hz,1500 W rating, with closed/vented type,(type: vertical,material of the inner container copper) capacity of 25 Lts including for inlet & outlet complete all as specified and as directed. Make:-Havells model No.Puro turbo or equivalent other make specified in the list of manufacturer. Note:-PVC connection shall be meassured and paid seperately.
COOLING APPLIANCES:- Supply install and testing Water cooler fully stainless steel Electric driven (single phase) having approx storage capacity of 80 litres and nominal cooling capacity of 40 litres per hour having minium 5 star rating working on non CFC refrigerant all as per specification and upto the satisfaction of engineer in charge.
Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 100V to 290V,with output voltage stabilized at 230V with accuracy of plus or minus 2.5% and of capacity 1 KVA, Make: V Guard - Model - VGSD 100 or equivalent other make specified in the list of manufacturer.
Miscellaneous:-PVC nonmetallic conduit rigid 20mm bore with and including conduit accessories from cable shaft to point complete all as pecified and as directed.
Modular typeTV socket one module including modular plate and meal flush box complete. Make Legrand cat part No.675546 /675561/689007 or equivalent other make specified in the list of manufacturer.
LEKSHMI ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .