Empanelment for the supply cath lab cosumables on running contract basis under KASP and other schemes
2026_DME_849904_1
C4/827/2025/GTDMCHA
Open Tender
Consumables
Empanelment
Govt TD medical college Hospital
Please refer Tender documents.
7 documents required · 7 mandatory
₹17,700
Yes
₹1 L
11 May 2026
11 May 2026
26 May 2026
11 May 2026
25 May 2026
11 May 2026
11 May 2026 - 13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1CORONARY STENTS | |||||
| 1.01 | DES,EVEROLIMUS,FDA/DCGI/CE APPROVED PLATINUM CHROMIUM PLATFORM,POLYVINYLIDENE FLURIDE-HEXAFLUROPROPYLINE PVDF-HFP POLYMER-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.Nominal pressure - 11 atm,Rated Burst Pressure 16-18 atm | 1 | No | - | - |
| 1.02 | DES,EVEROLIMUS,FDA/ APPROVED PLATINUM CHROMIUM PLATFORM,POLYVINYLIDENE FLUORIDE-HEXAFLUROPROPYLENE(PVDF-HFP)POLYMER | 1 | No | - | - |
| 1.03 | DES,EVEROLIMUS,FDA/DCGI/CE/ APPROVED PLATINUM CHROMIUM PLATFORM,BIOABSORBABLE POLYMER PLGA | 1 | No | - | - |
| 1.04 | EVEROLIMUS ELUTING PLATINUM CHROMIUM STENT SYSTEM | 1 | No | - | - |
| 1.05 | DES, EVEROLIMUS, L 605 COBALT CHROMIUM WITH HYBRID CELL DESIGN , STRUT THICKNESS- 65microns, POLYMER- PLGA diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. Length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44 | 1 | No | - | - |
| 1.06 | DES, EVEROLIMUS, COBALT CHROMIUM STRUT THICKNESS - 63 microns . Diameter- 2.25,2.5,2.75,3,3.5,4. Length- 8,10,13,15,18,20,24,28,32,36,40,42,44. Elutes 80% of drugs along with Re PLGA Polymer in the first 20 days | 1 | No | - | - |
| 1.07 | DCGI Approved Everolimus Drug Eluting 65 Micron Strut Thickness With 3 Micron PLLA&PLGA. A unique proprietory coating technology based
Biodegradable polymer Stent with Open cell designed and Flexia finished technology based cobalt chromium L605 stent.
A Designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal
radiopacity and excellent vessel supported stent with revers alternative link design(RAL) stent, with length from 8 mm to 52 mm and Diameter from 2.25 mm to 4.50 mm | 1 | No | - | - |
| 1.08 | CE APPROVED Everolimus Eluting Coronary Stent System Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. | 1 | No | - | - |
| 1.09 | CE APPROVED Sirolimus Eluting Coronary Stent System Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Ø Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. | 1 | No | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 16.96 MB
BOQ_1436118.xls
BOQ • 1.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .