Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹27.4 L Quoted ₹27.8 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹28.6 L+₹79,198 (2.85%)Rejected-AOC 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | ₹28.6 L+₹79,198 (2.85%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹31.6 L+₹3.8 L (13.6%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹31.6 L+₹3.8 L (13.6%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹33.5 L+₹5.7 L (20.7%)Rejected-AOC VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹33.5 L+₹5.7 L (20.7%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹34.8 L+₹7.0 L (25.1%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | ₹34.8 L+₹7.0 L (25.1%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹49.4 L
EMD Value
₹98,740
Closing Date
1 Feb 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS, MALL ROAD, DEHRADUN CANTT - 248003.
REPAIR AND REPLACEMENT OF INTERNAL WIRING, SUB MAIN WIRING, INTERNAL FIXTURES OF MD ACCN AND REPAIR REPLACEMENT OF CEILING FANS, EXHAUST FANS GYSERS IN MD AND OTM ACCN AT MIL STATION RAIWALA
2023_MES_575144_1
86389/RWL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) RAIWAL
Class D Category b(i)
8 documents required · 8 mandatory
₹500
AGE I RAIWALA
₹98,740
Yes
28 Feb 2023
16 Jan 2023
8 Feb 2023
16 Jan 2023
1 Feb 2023
27 Jan 2023
Amount
Dismantling and taking down old unserviceable point wiring of any type (light, fan, socket, power etc) complete with fitting such as switches, sockets, ceiling roses, pendants, lamp holders, light fitting etc including CI/ pressed steel terminals, switch box and making good the disturbed surface of wall/ floor etc to match with the existing surfaces of wall/ floor complete all as specified and directed. Note :- (i) If the contractor fail to make good the disturbed surface of wall/ floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute, the decision of Accepting Officer will be final and binding. (ii) Old fittings/ fixtures / accessories like switches, sockets, lamp holders, regulators etc., if found in serviceable condition shall be removed carefully for reuse in the work or taking on charge. (iii) Only old unserviceable items will be considered in credit Sch.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including concealed PVC conduit "medium grade" (ISI marked), not less than 20mm dia duly concealed on wall/ ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:- Note:- (i) Cost of cutting chases of suitable girth where required on brick /concrete surface and making good disturbed surface in CM (1:3) and matching with the existing surface deemed included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery of @ Rs. 50/- per RM will be made from payment due to the contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 2 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in existing concealed conduit (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 4 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including surface rigid PVC conduit (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 6 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
M&L for point wiring with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed, drawn in and including PVC Casing caping (Color coding of wires shall be phase, neutral and earth wire all as specified) sunk metal flush box with and including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including white cover plate complete all as specified and directed for following:-
One light/fan/exhaust fan/call bell point controlled by one way 5 Amp switch.
One 5 pin socket out let 5/6 Amp on independent board.
One 5 pin socket out let 5/6 Amp on same board.
One light point controlled by two way 5 Amp switch.
Descrition same all as per item No 8 above, but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 01/ Havells Cat Part No: ACWSXXW101 or equivalent of other makes as specified.
S&F modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 11/ Havells Cat Part No: ACWSXXW161 or equivalent of other makes as specified.
S&F modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 52/ Havells Cat Part No: ACWKPXW063 or equivalent of other makes as specified.
S&F modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 55/ Havells Cat Part No: ACWKCXW163 or equivalent of other makes as specified.
S&F modular switch piano, 1module, flush type button 5/6 Amp single pole two way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 02 or equivalent of other makes as specified.
S&F modular switch bell push button type, 1module, 6 Amp single pole complete all as specified and as directed. Make – Legrand cat No: 6734 04 or equivalent of other makes as specified.
S&F modular fan regulator electronic, 2module, stepped type, suitable for ceiling fans of any capacity, pre-wired 120/ 280 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Legrand cat No: 6734 30 or equivalent of other makes as specified.
S&F in repairs modular switch piano, 1module, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 01/ Havells Cat Part No: ACWSXXW101 or equivalent of other makes as specified.
S&F in repairs modular switch piano, 1module, flush type button 15/16 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Legrand cat No: 6734 11/ Havells Cat Part No: ACWSXXW161 or equivalent of other makes as specified.
S&F in repairs modular socket outlet, 2 module, five pin 2 in 1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 52/ Havells Cat Part No: ACWKPXW063 or equivalent of other makes as specified.
S&F in repairs modular socket outlet, 2 module, five pin 2 in1, 15 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Legrand cat No: 6734 55/ Havells Cat Part No: ACWKCXW163 or equivalent of other makes as specified.
S&F in repair switch piano, flush type button 5/6 Amp single pole one way conforming to IS: 3854 and ISI marked complete all as specified and directed. Make: Anchor Cat Part No- 95111/ 14111 or equivalent of other makes as specified.
S&F in repair socket outlet, five pin 2in1, 5 Amps, flush type, 230 volts AC circuit complete all as specified and directed. Make: Anchor Cat Part No- 14304 / 95304 or equivalent of other makes as specified.
S&F in repair switch piano flush button type 15 Amp single pole one way complete all as specified and as directed. Make – Anchor Cat Part No-14401 or equivalent of other makes as specified.
S&Fin repair socket outlet 2 in 1, 3/6 pin, 5 Amp and 15 Amp multipurpose flush type complete all as specified and as directed.. Make – Anchor Cat Part No-14307 or equivalent of other makes as specified.
S&F ceiling rose surface bakelite 65 x 25mm dia three terminals (ISI Marked) complete all as specified and directed. Make – Anchor Jumbo Code-39050 / 3224 or equivalent of other makes as specified.
S&F in repair ceiling rose surface 65 x 50mm three terminals, PVC poly corbonate, isolated body complete all as specified and directed. Make – Anchor Jumbo Code-39050 / 3224 or equivalent of other makes as specified.
S&F in repairs switch bell push button type 6 Amp single pole complete all as specified and as directed. Make – Anchor Code-14113 or equivalent of other makes as specified.
S&F bell electric DING DONG type, AC, 230V single pole, 2module complete all as specified and as directed. Make – Legrand cat No: 5734 43 or equivalent of other makes as specified.
S&F in repair bell electric DING DONG type, AC, 230V single pole complete all as specified and as directed. Make – Anchor Penta -Code-38921 or equivalent of other makes as specified.
S&F angle Lamp holder (with metal ring), insulated body, of PVC/ Polycorbonate with back plate (ISI Marked) suitable for batten fitting complete all as specified and as directed. Make– Anchor, Code-39797 or equivalent others make as specified.
S&F in repair angle Lamp holder (with metal ring), insulated body, of PVC/ Polycorbonate with back plate (ISI Marked) suitable for batten fitting complete all as specified and as directed. Make– Anchor, Code-39797 or equivalent others make as specified.
S&F in repair fan regulator electronic, stepped type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed. Make: Anchor, Cat Part No 14501/ 95502 or equivalent others make as specified.
S&F in repairs modular white cover plate with frame of the following module complete all as specified and directed:-
4 module.
8 module.
Dismantling and taking down u/s sub-main wiring/service wire of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/floor to match with the existing wall/floor etc complete all as specified and as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH, PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (medium grade) with standard accessories and earth wire connected with main earth dolly, of the following sizes of cable & dia of conduit complete all as specified and directed:- NOTE :- (i) Two/four run of single core FRLSH PVC cable with one/two run of earth conductor and conduit shall be measured as one unit (RM). (ii) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc of any description for concealing the conduits to required depth & making good the disturbed surface in CM (1:3) including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawal plugs.
2x6 Sqmm + 1x6 Sqmm earth wire with PVC conduit 20mm dia
2x4 Sqmm + 1x4 Sqmm earth wire with PVC conduit 20mm dia or more
4x6 Sqmm + 2x6 Sqmm earth wire with PVC conduit 25mm dia
4x4 Sqmm + 2x4 Sqmm earth wire with PVC conduit 25mm dia
S&F sub main wiring alongwith earth wire (green colour) with single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn with existing conduit of the following sizes of cable complete all as specified and directed:- NOTE :- (i) Two/ four run of single core FRLSH PVC cable with one/ two run of earth conductor shall be measured as one unit.
2x4 Sqmm + 1x4 Sqmm earth wire
4x4 Sqmm + 2x4 Sqmm earth wire
S&F Decorative gate light made up of high grade unbreakable polycarbonate material complete with 30 Watt LED Lamp (B22) including connecting up with twine core twisted flexible copper conductor cable with suitable size of 230v, 50HZ all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground, earth pit not less than 2.25 mtr depth below ground level at any type of strata with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC (1:3:6) type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM (1:4) funnel with wire mesh, RCC pit cover of 320 x 320 x 80mm size PCC (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed.
Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Disconnecting and taking out old damaged existing main switch/ distribution board of MCB/MCCB of any description from wall with and including all fitting and fixture and making good to disturbed surface of wall/ floor to match with the existing wall/ floor etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/ floor to the entire satisfaction of Engr-in-Charge, a recovery of @ Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of Accepting Officer will be final and binding.
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 240V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB SPN, 4 way
DB SPN, 8 way
DB SPN, 12 way
S&F connecting & testing distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB TPN, 4 way
S&F connecting & testing vertical distribution board of sheet metal enclosures double door, IP-43, 415V, for using MCCBs / MCB isolators with having tinted copper bus bars suitable for 200 Amps rating having following capacity complete all as specified and directed:-
DB VTPN, 4 way
S&F connecting & testing MCB, 230V/ 415V with rupturing capacity 10 KA of following capacity complete all as specified and directed:-
MCB 6 to 32 Amp, SP, 'B' series/ curve,
MCB 6 to 32 Amp, SPN, 'C' series/ curve,
MCB 40 to 63 Amp, TPN, 'C' series/ curve, Note for all item of DBs & MCCBs/ MCBs: - DBs (sheet metal enclosures) and MCCBs/ MCBs should be the same make.
S&F industrial type socket & plug top of 20Amp, 230V, Single Pole and neutral, sheet metal enclosure with and including MCB of ‘C’ series 10KA of following capacity complete all as directed and specified :- Note : - Industrial type socket & plug top (sheet metal enclosure) and MCB should be the same make.
Single Pole, 20 Amps, 240 volt.
S&F in repairs PVC round box, junction box of four terminal and connect on existing PVC conduit pipe 20/ 25mm dia and making surface good with suitable PCC and match with the existing surface complete all as specified and as directed.
S&F in repairs new metal modular flush box on wall and connect with modular switch/ socket etc while connect with existing PVC stranded copper conductor wiring of following module complete all as directed and specified :- Note :-1. Length of wire upto 2m deemed included in quoted rates. 2. Modular switches / sockets etc shall be measured and paid separately.
1/2 module.
3 module.
4 module.
8 module.
Taking out & removing old burn-out winding of electric fans of size 1200/1400 mm sweep and rewinding of fan motor with appropriate size super enamelled copper wire (Make: Atlas/ Finolex/ Devi Dayal) as approved by the AGE (I) including insulating material such as illuminous paper leatherized paper, cotton tape , glass sleeving, insulating varnish including ball bearing/ bushes/ hanging assembly etc, if required and testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction complete all as specified and directed. Note : Before taking to rewinding, check the winding condition of fans, if fan winding found fault cut the primary winding and secondary winding in front of Engr -in-Charege and removing fan bearing and deposit to MES store yard while complete repairs collect bearing from store yard.
M&L for painting of ceiling fans/ exhaust fan any descption with applying one coat of synthetic enamel paint (White) by spray machine including cavity filling with filler and preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body and testing complete all as specified and directed.
Dismantling of exhaust fan of any make/ model, opening for cutting, taking out existing unserviceable winding wire and rewinding with super enamel copper wire (Make: Atlas/ Finolex/ Devi Dayal) as approved by the AGE (I) of existing gauge, including varnishing and insulating material with washer, split pin, checknut, hanging clutch, condenser clamp, assembling, with required flexible wire of following sweep size complete all as specified and directed :- NOTE : Before taking to rewinding check the winding condition of fans if fan winding found fault cut the primary winding and secondary winding in front of Engr -in-Charege and removing fan bearing and deposit to MES store yard while complete contract collect bearing from store yard as schedule of credit and testing
450/380 mm sweep
350/300 mm sweep
250 mm sweep
Taking down exhaust fans 450/ 380/ 350/ 300/ 250/ 200 mm sweep, removing and cleaning of dust properly with and including oiling and greasing of bearing with and including replacement of washer, new split pin & any other minor spare parts such as new screw, checknut, pin etc and refixing in position, connecting, testing complete all as directed
Supply only following spare / parts for fan/ exhaust fan complete all as specified and directed :- Note : Spare / parts of fan/ exhaust fan required during repaire shall be measured and paid as supply only. Cost of replacement deemed included in quoted rates.
condenser 4 MFD
condenser 2.15 MFD
condenser 3.15 MFD
Copper flexible PVC sheathed and overall insulated three core cable 23/.0076
Ball bearings 6202, 6203, 6201 or suitable size as reqd duly greased packed of Make DKF/NBC.
Gun metal bushes of suitable sizes as required
Fan hanging clamps complete including rubber reel, nuts, bolts and washers
S&F 20mm GI down rod for ceiling fan, length of down rod 1 m length complete all as specified and directed.
Taking down carefully storage electric water heater (Gyser) and dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with rescaling liquid/ compound, overhauling complete to ensure free & continuous flow of water through outlet pipe, welding of inner tank if required at site, rethreading of inlet/ outlet pipe 15mm dia, reassembling the same at existing/ new place, testing/ commissioning after reinstallation like check the current continuity from existing main DB or exisiting ciruit board if extra wire reqired the rate of wire deemed to be included in the quoted rate of following capacity complete all as specified and directed :- Note : (i) All new spare parts reqd for overhauling of geysers shall be maesured & paid seperately as supply only schedule. (ii) Rate of Grouting of geyser on position with use of zinc plated pin drive expansion bolts-Hammer strike pin Anchor fasteners of required size depending on wall strength and rate of making surface good included in quoted rate.
25L Capacity
50L Capacity
Supply only following spare / parts for electric water heater (gyser) complete all as specified and directed :- Note : Spare / parts of electric water heater (Gyser) required during repaire shall be measured and paid as supply only. Cost of replacement deemed included in quoted rates.
Air release valve 15 mm bore as per existing type
Brass safety valve of size as per existing
Glass wool
Thermostat as per existing type
Thermal cutout unit as per existing type
Heating element 1.5 KW as per existing type
Heating element 2.0 KW as per existing type
Sypohon assembly as per existing model/shape made out of chromium plated brass suitable for 25 Ltr capacity
Sypohon assembly as per existing model/shape made out of chromium plated brass suitable for 50 Ltr capacity
Indicator Lamp/ bulb as per existing type
Rubber gasket round in shape 8 to 9 holes
Inner shell as per existing type/size/shape suitable for 25 Ltr capacity
Inner shell as per existing type/size/shape suitable for 50 Ltr capacity
S&F in repairs PVC connection 15mm and 450mm long with brass nut & washer for water inlet/ outlet complete all as specified and directed.
S&F in repairs 15mm dia stop valve cast copper alloy (brass), chromium plated, screwed down, high pressure, with crutch or butterfly handle screwed both end cock complete all as specified and directed.
S&F in repairs 15mm dia GI pipe, medium grade including all fittings such as Tee, union, socket, bends, elbow, nipple, union for geysers from inlet/ outlet connection complete all as specified and directed.
Disconnecting, taking down and refixing of solar water heater including necessary repair of Flat plate collector and cleaning of Inner vaccum tube and outer vaccum tube if tank found broken weld with seamless and non welding technology check pressure of out let water and replace heating element 3 KW and thermostat check power continuity cleaning of pipe line and re insulated the existing GI pipe 15/ 20 mm dia with glass wool upto 15 mtr length, of following capacity complete all as specified and directed :-
Upto 500 Ltrs capacity
Upto 1000 Ltrs capacity
S&F PVC insulated 3core 2.5 Sqmm flexible copper cable 1100 Volt grade, round sheathed conforming to IS 694 complete all as apecified and directed.
S&F PVC plug top 16 Amps (ISI marked) on existing three core copper cable or new three copper three cable all as specified and directed.
neeraj electricals
M/s badrinath Traders
AMAR NATH SHARMA
PARADISE INFRA POWER COMPANY
TARUN ENGINEERING WORKS
BK CONSTRUCTION
M/S BABA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .