Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.0 L+₹75,100 (23.1%)Rejected-Finance 2 3 AMIT VIJAY APT CHSL KASTURBA CROSS ROAD NEAR BHANU PARK KANDIVALI WEST MUMBAI 400 067 | MUMBAI | MUMBAI | MAHARASHTRA | 400067 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹4.7 L+₹1.5 L (46.2%)Rejected-Finance 196 GOREGAON W MUMBAI MAHARASHTRA 400062 | 400062 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹5 L
Closing Date
9 Apr 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
CONSULTANCY FOR REHABILITATION AND RE-STRENGTHENING OF BUILDING NO P-7, P-9, P-18, P-19 P-22 AT BASANTAR LINE UNDER GE (WEST), DELHI CANTT
2020_MES_335406_1
3001/10/E3
Open Tender
Consultancy Services
Item Rate
30 days
DELHI CANTT
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
11 Jul 2020
19 Mar 2020
11 Apr 2020
19 Mar 2020
9 Apr 2020
20 Mar 2020
Amount
1. Survey for condition of bldgs: To carry out a detailed visual inspection for surface damages, cracks, seepage, local weakness and to identity locations of structural and functional distress and locations supected to develop structural and functional distress of the buildings. 2. Non-destructinve Tests(NDT) : Non destructive evaluation of the structural elements by various tests as required location and structural assessment based on these parameters. 3. Rebound Hammer Test : To check the compressive strenght of concrete as per IS-13311-1992 Part II. 4. Ultrasonic Pulse Velocity (UPV): As per IS-516, measurements on the RCC elements to find out the quality of concrete. 5. Ferroscanning : To locate the RCC elements and to check steel bars and its dtails like spacing cover and approx diameter. 6. Carbonation : To check the penetration depth of carbonation in concrete. 7. Core Cutting & compressive strenght test : Take out the sample of cylindrical concrete and carry out compressive strength test at a minimum of one location per dwelling unit. 8. Corrosion monitoring : To measure the risk and rate of corrosiooin of steel in concrete by half cell potential of reinforcement to assess the risk of corrosion. 9. Concrete cover measurement : Measurement of thickness of concrete cover to reinforcement bars by cover meter test. 10. Chemical analysis : To draw samples of concrete and carry out chemical analysis of the sample including measurement of chloride content. 11. Themographic imaging : For inspection of moisture/dampness in the structures for pin pointing the moisture trail. 12. Structural Evaluation and Retrofitting Scheme : This would include assessment of adequacy of existing structural components and providing retrofitting scheme to strengthen the inadequate structural compoments including repair methodology, preparatin of bill of quantitites (BOO), specification for the work, methodology, preparation of bill of quantities (BOQ), specification for the work. Report must be submitted in QUADRUPLICATE. Note :- Term & condition also attached.
B J MEHTA ARCHITECTURAL AND STRUCTURAL CONSULTANTS PVT.LTD.
IDDC Engineers Private Limited
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_375037.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .