Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAdmitted-Finance H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹6.0 L | L1 | Admitted-Finance |
| 2 | L2₹6.1 LAdmitted-Finance | ₹6.1 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RS COOLING APPLIANCES L1 | DEBASISH PAUL CHOWDHURY L2 |
|---|---|---|---|---|---|
| 1.00Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 ft between the room unit and outdoor unit as directed by the department with variable compressor which adjust power depending on heat load, Annual energy consumption <=920 kwh, ISEER value>=5.00, 100% Cu condenser coil complete and as directed by department. (Make: Bluestar/LG/Carrier/Samsung/Hitachi) | |||||
| 1.01 | 2.00 tonn, BEE 5 star rated inverter AC | 5 | nos | 52,790 ₹2.6 L | 65,000 ₹3.3 L |
| 2.00 | Supply and installation of AC voltage stabilizer (voltage-130-260V) , with seven segment LED display ,12-10A capacity, thermal and overload protection complete as directed.(Make-Hitech/Vguard/Skyland) | 5 | each | 4,290 ₹21,450 | 5,000 ₹25,000 |
| 3.00 | Supply and installation of AC outdoor stand complete as directed. | 5 | each | 1,090 ₹5,450 | 1,500 ₹7,500 |
| 4.00Wiring for circuit/ submain rewiring wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | |||||
| 4.01 | 4 X 4 sq. mm + 1 X 4 sq. mm earth wire | 140 | meter | 590 ₹82,600 | 300 ₹42,000 |
| 4.02 | 4 X 10 sq. mm + 2 X 4 sq. mm earth wire | 40 | meter | 759 ₹30,360 | 600 ₹24,000 |
| 5.00Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. | |||||
| 5.01 | Group C | 5 | point | 990 ₹4,950 | 1,000 ₹5,000 |
| 6.00Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required | |||||
Tender Value
₹6.6 L
EMD Value
₹13,206
Closing Date
5 Dec 2025, 11:00 amClosed
Registrar
Registrar Office Administrative Building Assam University Silchar
Supply and Installation Inverter AC with electrical wiring, providing fitting, fixing computer points at Central Library Assam University Silchar.
2025_AUS_887717_1
AU/ENGG/MAINT/ELECT02/2025
Open Tender
Electrical Works
30 days
Assam University Silchar
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Assam University Silchar
₹13,206
6 Jan 2026
29 Nov 2025
8 Dec 2025
29 Nov 2025
5 Dec 2025
29 Nov 2025
Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 ft between the room unit and outdoor unit as directed by the department with variable compressor which adjust power depending on heat load, Annual energy consumption <=920 kwh, ISEER value>=5.00, 100% Cu condenser coil complete and as directed by department. (Make: Bluestar/LG/Carrier/Samsung/Hitachi)
2.00 tonn, BEE 5 star rated inverter AC
Wiring for circuit/ submain rewiring wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
4 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 10 sq. mm + 2 X 4 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Single pole
Double pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door, 415 V TPN Double door MCB Distribution board.
SITC DOL contact starter for operation of lab equipments complete with required (L&T /Havells/Legrand) enclosure complete as directed.
Supplying with fitting and fixing panel mounting open execution 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.25 KA 415V 50 Hz 4P MCCB (Schneider, Legrand, Siemens, Indo Asian make)
Copper pipe including cable fitting ( 1/4, 1/2, 5/8)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 sq. mm
2 x 2.5 sq. mm
3 x 2.5 sq. mm
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_933074.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid