| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | ₹5.3 L | L1 | Accepted-AOC Meet NIT Criteria |
| 2 | L2₹5.6 L+₹26,930 (5.06%)Rejected-Finance | ₹5.6 L+₹26,930 (5.06%) | L2 | Rejected-Finance Does not Meet NIT Criteria |
| 3 | L3₹6.0 L+₹66,820 (12.5%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹6.0 L+₹66,820 (12.5%) | L3 | Rejected-Finance Does not Meet NIT Criteria |
| 4 | L4₹6.5 L+₹1.2 L (22.8%)Rejected-Finance SHIV SHAKTI NAGAR PLOT NO 35 NIWARU ROAD JHOTWARA JAIPUR 302012 | JAIPUR | RAJASTHAN | 302012 | ₹6.5 L+₹1.2 L (22.8%) | L4 | Rejected-Finance Does not Meet NIT Criteria |
| 5 | L5₹7.7 L+₹2.4 L (45.4%)Rejected-Finance PLOT NO 1235 JLPL SECTOR 82 SAS NAGAR MOHALI MOHALI PUNJAB 160055 | S A S NAGAR | PUNJAB | 160055 | ₹7.7 L+₹2.4 L (45.4%) | L5 | Rejected-Finance Does not Meet NIT Criteria |
Tender Value
Refer Docs
Closing Date
29 Mar 2021, 6:00 pmClosed
SENIOR MANAGER
KANGRA AIRPORT, KANGRA - 176209
Provision of Air-conditioning System in ATC Tower at Kangra Airport
2021_AAI_73994_1
AAI/Engg-E/Kangra/AC Tower/2020-21
Open Tender
Electrical Works
Works
120 days
KANGRA AIRPORT
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,120
Exempted
7 May 2021
22 Mar 2021
31 Mar 2021
22 Mar 2021
29 Mar 2021
22 Mar 2021
22 Mar 2021 - 26 Mar 2021
Amount
Supply of 3.0 Ton, Invertor Cassette type Air-Conditioner units with Heat and Cold mode fitted with Inverter Rotary sealed compressors operating on refrigerant R410 / Eco Friendly Green Gas, confirming to IS 1391 (Part-2)/1992 with latest amendment suitable for operation on 415V / 230V ±10%, 50Hz, Three / Single Phase AC Supply complete with Indoor and Outdoor Units, Cordless Remote Control and all acessaries etc. complete as required.
Installation, Testing and Commissioning of 3.0 Ton Inverter Cassette type Air - Conditioner complete with Indoor and Outdoor Units, Cordless Remote Control and all acessaries including electrical connections between the indoor outdoor unit, suitable size of MS stand / Bracket Stand for out door unit and wall cutting, hole cutting, plastering and making wall good condition etc. complete as required.
Supply and laying of copper refrigerant (Suction & Discharge) pipies along with insulation & protective covering including electrical cable of suitable size and core from Indoor to Outdoor etc. as per requirement of 3.0 Ton Inverter Cassette type Air - Conditioner etc. complete as per site requirement.
Supply, installation, testing and commissioning of 25mm OD UPVC pipe for drain line with proper slope complete with fittings, supports including connections etc. complete as required.
Supplying and installing of following size of perforated painted with powder coating G.I. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (a) 150 mm width X 50 mm depth X 1.6 mm thickness
Supplying & installation of Outdoor type Cable termination / looping box of minimum size 315 x 600 x 214 made of thermoplastic polycarbonate having minimum IP65 protection alongwith clamp etc. complete as required. (Make Hansel or Equivalent).
Supplying and fixing following rating, four pole, 415 V, 10kA isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A
Supplying and fixing following rating, four pole, 415 V, 10kA MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 32 A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
Supplying and drawing of 4Cx6 sq.mm. PVC insulated and PVC Shealthed copper conductor cable in the existing surface/ recessed steel/ PVC conduit as required.
Supply of following size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098 : 1988 with upto date amendments. (a) 4C X 16 Sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. (a) Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a) Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply and making end termination with brass compression gland and aluminium thimbles for PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade of 4 core, 25 Sq. mm sizes as required.
Cutting / Making opening of required area for ITC of 4.0 TR Cassette type indoor unit in the existing aluminium / gypsum false ceiling and making the damages good by providing and fixing Gypsum plasterboard of approved material in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel sections consisting of "T" runner and "T" Cross duly suspended from ceiling etc. complete as directed by Engineer - in - charge. (Each opening made for each unit and making the damages good will be counted as one Job)
Anil Kumar Sharma
VOLKS ENERGIE PVT LTD
Navyug Engineering
Ace Cooling Solutions
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .