| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹27.5 L+₹1.8 L (7.08%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹28.1 L+₹2.5 L (9.56%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹28.3 L+₹2.7 L (10.4%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹29.1 L+₹3.5 L (13.5%)Rejected-Finance INDEX NO E 53 CWE BHUJ OPP SHRI HALARI BHANUSHALI WADI OUTSIDE KHAMBHALIYA GATE NR PAVAN CHAKKI JAMNAGAR 361005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L5 | Rejected-Finance NOT L1 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE A JAMNAGAR
INFANTRY LINES JAMNAGAR
REPAIR/ RENEWAL/ MAINTENANCE OF GI/CI/DI WATER PIPE LINES ALONG WITH CONNECTED ITEMS IN THE AREA OF AGE E/M (ARMY) JAMNAGAR UNDER GARRISON ENGINEER (ARMY) JAMNAGAR.
2023_MES_621116_3
8030
Open Tender
Civil Works
Item Rate
274 days
JAMNAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹48,000
21 Feb 2024
25 Jan 2024
10 Feb 2024
26 Jan 2024
8 Feb 2024
31 Jan 2024
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of pipe line and getting out in soft/ loose soil complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified & directed
Removing excavated meterial to a distance n.exc 50m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified & directed by Engineer-in-Charge
Taking down/ up old unsv CI Pipe line of following bore dia including all fittings etc complete all as specified and directed by Engineer-in-Charge:-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 250 mm dia
Taking down/ up old unsv ERW MS Pipe line of following bore dia including all fittings etc complete all as specified and directed by Engineer-in-Charge:-
(a) 150 mm dia
(b) 200 mm dia
(c) 250 mm dia
Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-9, with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified of following sizes:-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 250 mm dia
M & L for ERW MS black seamless pipe with 8 mm thickness, conforming to IS-1239 Part -II, grade 330 including MS flange,cuttings, welding and replacement of MS bends, nut bolts washers, rubber packings, rubber joints gasket etc as per site rerquirements duly painted with two coats of lead free synthetic enamel paint all as specified and directed by Engr-In-Charge for the following dia of pipe
(a) 150 mm dia
(b) 200 mm dia
(c) 250 mm dia
M & L for Ductile Iron (DI) connecting pieces/ fittings one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapering as bell mounth, Bends tapers, Tees, pieces (Single or double branch) any type and angle/ radius and straight connecting pieces for DI Pipe upto 100 mm to 250 mm dia bore including DI Fittings all socket and spigot such as bends (any type, radius and angle) tapers any type, tee and reducing tees suitable for spigot and socket pipes etc all as specified and directed by Engr-in-charge.
M & L for MS Fittings such as bends (any type, radius and angle) tapers any type, flange,tee and reducing tees suitable for MS pipes of size 150 to 250 mm dia etc all as specified and directed for the following sizes :-
M & L for CI Fittings all socket and spigot such as bends (any type, radius and angle) tapers any type, flange,tee and reducing tees suitable for spigot and socket pipes etc all as specified and directed for the following sizes :-
(b) Up to 150 bore in mm dia
(a) 200 to 300 bore in mm dia
M & L for Cutting the existing cast iron/DI pipes in position for insertion of new tees, branches etc all as directed for following sizes of pipes :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 250 mm dia
S & F Cast iron sluice valve heavy duty with stainless steel spindle and cast iron hand wheel complying with IS:14846-2000, class PN 1.6 both ends flanged with cast iron hand wheel & 2 Nos 3 mm thick rubber insertion gasket sheet joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one of the following bore sizes complete all as specified for the following sizes :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia
(d) 250 mm dia
(e) 300 mm dia
Supply and Fixing cast iron body and brass gate heavy duty non return valve, 100 mm dia, ISI marked ( NRV) both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one complete all as specified :-
S & F CI butter fly valve with both side flanged ends PN 1.6 ISI marked, complying with IS-13095 including jointing material such as gasket, nut, bolts etc including removal of old unsv one complete all as specified and as directed by Engineer-in-Charge.
(a) 100 mm dia
(b) 200 mm dia
M & L for attending the emergent repairs to leakage/ damage CI/DI pipe of size 80 mm dia & 100 mm dia including carrying out minor repairs etc as required to make the system in order/ functional and necessary excavation, returning , filling of soils and removal of water by using pump, cutting out CI/DI pipe at both ends and jointing with new fittings, accessories complete all as specified and as directed by Engr-in-charge.
M & L for attending the emergent repairs to leakage/ damage CI/DI pipe of size 150 mm dia including carrying out minor repairs etc as required to make the system in order/ functional and necessary excavation, returning , filling of soils and removal of water by using pump, cutting out CI/DI pipe at both ends and jointing with new fittings, accessories complete all as specified and as directed by Engr-in-charge.
M & L for attending the emergent repairs to leakage/ damage CI/DI pipe of size 200 mm dia including carrying out minor repairs etc as required to make the system in order/ functional and necessary excavation, returning , filling of soils and removal of water by using pump, cutting out CI/DI pipe at both ends and jointing with new fittings, accessories complete all as specified and as directed by Engr-in-charge.
M & L for attending the emergent repairs to leakage/ damage CI/DI pipe of size 250 mm dia including carrying out minor repairs etc as required to make the system in order/ functional and necessary excavation, returning , filling of soils and removal of water by using pump, cutting out CI/DI pipe at both ends and jointing with new fittings, accessories complete all as specified and as directed by Engr-in-charge.
Note for item No 15 to 18 : (i) Rate inclusive of jointing work, excavation & retuning, filling after repairs of earth work in type of soil. (ii) CI/DI fittings will be paid separately in respective items.
Supply and Fixing cast iron mechanical joints heavy duty both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including necessary excavation of earth work and removing of old unsv one of the following bore sizes complete all as specified :-
(a) 100 mm dia
(b) 150 mm dia
(c) 200 mm dia.
(d) 250 mm dia.
M & L for CI sluice valve Spindle made out of stainless steel suitablly threaded as per requirement including provision of necessary suitable chechnut made out of Gunmetal inserting in the extg unsv CI sluice valve including removing of old unsv one from sluice valve for following sizes complete all as spicified and directed by Engr - In - Charge
(a) 100 mm dia
(b) 150 mm dia
(c) 200mm dia
(d) 250mm dia
S & F Integral LED aviation obstruction light fitting comprising of aluminium housing with ploycarbonate enclosure including taking down old unserviceable light from any height of OH tank complete all as specified and as directed.
Demolition of PCC work, brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc all as specified and directed.
M & L for brick work with sub class `B` bricks using old size bricks straight on plan built in cement mortar 1:6 etc all as specified and directed.
M & L for 15 mm thick rendering in CM 1:6 on fair faces of brick work / concrete work and finished even& smooth without using extra cement all as specified and directed.
M & L for providing PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping of valve chamber 50 mm thick for embedding steel frame.
Prime Decor
Rameshwar Enterprise
Hirachand Sunderji and co
Shah Associates
M/s Balaji Enterprise
M/s Shivan Enterprise
badri glass and construction
jitendra c joisar
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .