Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50,654Accepted-AOC ANGANWADI NO 33 SUBHASH NAGAR 37 ELENJIMOODER 30 42 MUBBELNADA AVALAULAN 34 SCOORYA NAGAR 22 KODALBONA VENDULALBEIBOUARO ANGANWADI POWDIKOUAM WARD PROJECT NO 612 25 | KANGPOKPI | MANIPUR | 795002 | ₹50,654 | L1 | Accepted-AOC ACCEPTED |
Tender Value
₹53,750
EMD Value
₹1,344
Closing Date
29 Jan 2026, 3:00 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer pwd electrical sub division kollam
GENERAL-AMC-Mini Civil Station, Pathanapuram-Annual Maintenance Contract of Electrical Installation for the Financial Year 20252026-General Electrical Work
2026_PWD_825579_2
PWD/BLDG/EST/18782/2025
Open Tender
Electrical Works
385 days
mini civil station pathanapuram
Please refer tender document
9 documents required · 9 mandatory
₹555
₹1,344
20 Jun 2026
23 Jan 2026
31 Jan 2026
23 Jan 2026
29 Jan 2026
23 Jan 2026
Maintenance of EI
90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
OD186963/2025-2026:Supply and providing 20W, 1200mm LED Tube in the existing box type fittings after providing necessary alterations in the wiring of the fittings and make it good working conditions.
OD175561/2025-2026:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover with 9W LED bulb to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD175562/2025-2026:Supply and renewing fan condenser of ceiling fan in place of faulty ones and giving connection.
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
OD265347/2025-2026:Dismantling the existing damaged electrical installations and conveying the same to section store including making good the damages of wall etc as required-
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
AF.pdf
Tender Documents • 0.03 MB
PR.pdf
Tender Documents • 0.64 MB
IP.pdf
Tender Documents • 0.02 MB
s.pdf
Tender Documents • 0.13 MB
BOQ_1394346.xls
BOQ • 0.32 MB
E.pdf
Tender Documents • 0.01 MB
ls.pdf
Tender Documents • 0.12 MB
sbd.pdf
Tender Documents • 1.63 MB
tf.pdf
Tender Documents • 0.12 MB
Download all tender documents and submit your bid