Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹20.0 L
EMD Value
₹40,000
Closing Date
23 Oct 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Repair of existing lights at Yousmarg .Nagbal (Phase II)
2025_PWDJK_291499_1
NIT No.134/2025-26 Dt/10/10/2025
Open Tender
Electrical Works
Percentage
15 days
Yousmarg
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹40,000
10 Oct 2025
10 Oct 2025
24 Oct 2025
10 Oct 2025
23 Oct 2025
10 Oct 2025
Supply, installation, testing & comissioning of LED flood light having housing made of pressure die cast aluminium alloy (ADC12/LM6). The system wattage shall be 100W & the luminaire shall deliver system lumens ≥ 14000 lumens. The system efficacy of the luminaire shall be ≥140 lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire. The maximum dimensions of the luminaire shall be, L: 264M, Depth: 52MM & height without cradle: 203MM. The nominal weight of the luminaire shall be maximum 2.4KGs. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. of Philips /Lighting Techonology / Wipro/Endo /Regent make. The Agency / firm must submit the Techanical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering all damages /mulfunctioning /burnt out what so ever reasons
Supply, Installation, testing & commissioning of high-quality integrated LED Street Light with a minimum system lumen of 12600lm and system wattage of 90W (±3W). The luminaire should have minimum system efficacy of 140 lumen/watt for the measured lumen output/system wattage. The LED used shall have CCT of 5700K, SDCM ≤5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted/welded/mechanically joined to the luminaire housing to ensure robust design. The luminaire shall have Integrated IP66 polycarbonate front cover/lens. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. The luminaire LED shall have declared Lifetime of 75K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. The minimum luminaire dimensions shall be L: 435mm including spigot, W: 200MM, H: 135MM (Including Control Gear Compartment) & the minimum nominal weight shall be 1.8KG. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The luminaire shall have minimum windage area of 0.062Sq.mt. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only & shall be from either Lumileds, Osram, Nichia, Signify, APT Electronics Co. Ltd., CREE make or equivalent. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall be replaceable. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @full load, THD ≤10% @ full load, In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V & 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2. The driver shall be EMI/EMC Complied as per EN55015/CISPR15. The luminaire shall be able to give Constant Light output (CLO) between voltage range of 140V to 277V. The luminaire driver & it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer within 15 days of award of LOI. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before of of Philips /Lighting Techonology / Wipro/Endo /Regent/ eq. make to be approved by EIC. The Job includes 2-years replacement warrenty for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering all damages /mulfunctioning /burnt out what so ever reasons
Supply, Laying, Testing and Commissioning of XLPE insulated PVC inner sheathed steel armoured Al Cable of standard dully isi maked to be approved by department not below the rank of SDO incl making of necessary connections with proper size of Al Thimbles dully crimped with crimping tool
50 Sq mm 3.5 Core
10 sq mm 4- Core
Earth work excuation of hard /soft soil upto 2ft in depth and 1 ft in width by manual /mechanical means with refilling of Soil after cable laying including disposal of surplus soil.
Earthing of poles with GI rod of 6 ft long to be embedded in a pit with extending of earthing from rod to pole by way of p/l of 25 mm flat iron strip from electrode to pole
Supply and laying of 40 mm dia HPPE flexible Pipe (air Cusion type heavy duty ) for laying of Cables in cable trench.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface! recessed steell PVC conduit as required.
3x1.5sq. mm
Supply ,installation ,Testing and Commissioning of Pole Boxes made of heavy guage Sheet Steel dully powder coated painting with pole mounted clamp with nuts and bolts
Supplying and fixing 5 A to 32 A rating SPN , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required. Of Legrend /L&T /ABB /Simens/ eq. make to be approved by EIC
Single pole
Supplying and fixing 32-40 rating, 240/415 V, 10 kA, "C" curve DP MCB , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required.Of Legrend /L&T /ABB /Simens/ eq. make to be approved by EIC
Supply ,installation ,Testing and Commissioning of 63-100 Amps 4-pole Connector
Supply Installation ,Testing and Commissioning of Outdoor type 200 Amps TPN Aluminium Bus Bar Chamber having fitted with phase indicators and metering devices & provided and fitted with Angle iron stand with Legs upto 2 ft in length
Providing and laying of Cement Concrete of Ratio 1:2:4 with 20 mm nominal size of aggerate including carriage from source to site of work.
Supply and applying one coat of red oxide paint and two coats of Aluminium Paint
Dismentling of existing damaged / non functional lighting fixtures ,damaged wiring / Cabling etc stacking of same at safer place and handing over to intending department
Point wiring for switch controlled primary light points with 3x1.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/ Salzer /RR Kabels make, to be laid in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch with modular cover plate of Schneider /ABB /L&T /Legrand /Simens/ eq. make to be approved by EIC , complete as per specification and as required to be fitted on existing GI boxes .The Job includes providing and laying of circuit wiring with 3 x 1.5 Sq.mm PVC Insulated multistranded copper to be laid through pvc conduit from DB to first switch in sub circuit complete job including cost of conduits .
Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLs PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires of Polycab/Finolex/Anchor/ Salzer /RR Kabels/ eq. make to be approved by EIC, to be laid in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 2 no 240 volts 6 amp 5 pin socket out let along with 2 No's of 6 Amp control Switch of with modular co
ver plate of Schneider /ABB /L&T /Legrand /simens / eq. make to be approved by EIC , complete as per specification and as required to be fitted on existing GI boxes . The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit (Maximum two points shall be connected /provided in one circuit and no extra circuit wiring shall be paid what so ever reason or length) Complete as required (including cost of conduits)
Point wiring for 16 Amp Socket out lets ( Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Polycab/Finolex/Anchor/ Salzer /RR Kabels / eq. make to be approved by EIC, to be laid in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch with modular cover plate of Schneider /ABB /L&T /Legrand / eq. make to be approved by EIC , complete as per specification and as required to be fitted on existing GI boxess with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit (Maximum two points shall be connected / provided in one circuit and no extra circuit wiring shall be paid what so ever reason or length) (including cost of conduits)
Supply, Installation, Testing and commissioning of 12 watt LED surface/recessed Down lighters having Aluminium Body (Commercial type ) ,minimum lumens 100 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C of Philips / LT/Wipro/ /Regent /Endo/ eq. make to be approved by EIC incl making of necessary Connections. ).
Supply, Installation, Testing and commissioning of 50 Watts LED flood lighting luminaries having CRCA /Aluminium Body ,minimum lumens 120 lm/w ,the luminaries housing should be crca /aluminium and the luminary optics shall have a high efficiency with transmittance ,average life of 50000 hrs operating temperature -10 C to + 45 C f Philips / LT/Wipro/ Regent / Endo / eq. make to be approved by EIC incl making of necessary Connections. ).. The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of one years reckoned from date of successful commissioning /handing over of site to intending department.
Supply, Installation testing and commissioning of 1200 mm sweep Ceiling Fans of Crompton Greaves / Orient /Helonix / Usha/ eq. make ( Sample to be got approved ) Complete incl making of necessary connections
Supply, Installation testing and commissioning of 250-300 mm exhaust Fans shutter type of Crompton Greaves / Orient /Helonix / Usha/ eq. ( Sample to be got approved ) Complete incl making of necessary connections
8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrand / Siemens/ ABB /L&T / eq. make to be approved by EIC
Supplying and fixing of 63 Amp rating DP 240/415 volts (10 kA) "C" curve MCB`s Legrand / Siemens/ ABB /L&T / eq. make to be approved by EIC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.07 MB
BOQ_937895.xls
BOQ • 12.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .