Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹5.7 L+₹11,019.38 (1.96%)Rejected-Finance 23 2 P K CHOWDHURY LANE HOWRAH 711103 | HOWRAH | HOWRAH | WEST BENGAL | 711103 | L2 | Rejected-Finance higher than L1 | |
| 3 | L3₹5.8 L+₹15,134.66 (2.69%)Rejected-Finance 36 JESSORE ROAD HRIDAYPUR RATHTALA NORTH 24 PARGANAS | L3 | Rejected-Finance higher than L1 |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
7 Jan 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Repairing of PDB and ATS panel at ISLS-IV in AA-I under NTK Project.
2024_PHED_784650_3
PHE/NTKMD/e-16 of 2024-25
Open Tender
Project Work
Item Wise
21 days
WORK
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
24 Jan 2025
14 Dec 2024
9 Jan 2025
14 Dec 2024
7 Jan 2025
14 Dec 2024
Amount
Dismantling of all damaged spares parts and existing serviceable spare’s part (PDB Panel, and ATS panel 1 & 3) by part after disconnection of power line including servicing of all existing serviceable spares & Bus-bar rubbing by supplying of emery paper to remove carbon and Sulphur particles and all cleaning by supplying of CRC & cotton cloth all completed as per direction of EIC.
Supply of following spares at site for PDB panel :-
96 sq mm 0-1200 Amp Analog Ammeter. (Make : Rishab / other equivalent approved)
96 sq mm 0-500 Volt Analog Voltmeter (Make : AE / other equivalent approved)
415 Volt 630A TP MCCB with Breaking capacity 36kA. (Make : ABB / other equivalent approved)
Supply of following spares at site for ATS panel no. 1 :-
230V Auxiliary Contactors(2 NO + 2 NC) [Make : Siemens(3RH2122-1AP00-8K)]
96 sq mm digital Single phase Ammeter CI1.0. [Make : Schneider / other equivalent approved]
96 sq mm digital Single phase Voltmeter [Make : Schneider / other equivalent approved]
Multifunction meter Class accuracy Cl0.5S, POP [Make : Schneider (EM6400NG+) / other equivalent approved)
6 Amp. DP MCB, Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
10 Amp. DP MCB Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
6 Amp. FP MCB Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
On delay timer [Make : GIC / Approved Make]
6 Window Microprocessor Based Alarm Annunciator [Make : Minilec ; Model-1 0B 6S P0]
Indicating LED (R/G) [Make : L&T / Seimens / Approved Make]
Indicating LED (B) [Make : L&T / Seimens / Approved Make]
230 Volt AC Electronic Hooter.
100 Watt Space Heater (SPP-22)
Thermostat for Space Heater.
Modular Electric Bulb Holder.
9 Watt Led Lamp.
Piano 6A 1 Module 1 Way Switch.
1.1 KV grade 2.5 sq mm (FR) PVC Insulated (Unsheathed) single core multi strand Copper wire. [Make : Mescab / other equivalent approved)
1.1 KV grade 1 sq mm (FR) PVC Insulated (Unsheathed) single core multi strand Copper wire. [Make : Mescab / other equivalent approved)
Supply of following spares at site for ATS panel 3 :-
230V Auxiliary Contactors(2 NO + 2 NC) [Make : Siemens(3RH2122-1AP00-8K)]
96 sq mm digital Single phase Ammeter CI1.0. [Make : Schneider / other equivalent approved)
96 sq mm digital Single phase Voltmeter CI1.0 [Make : Schneider / other equivalent approved)
AC3 750 Amp power Contactor with auxiliary contacts 1NO & 1NC. [Make : ABB ; Model-AF750-30-11]
6 Amp. DP MCB, Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
10 Amp. DP MCB Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
6 Amp. FP MCB Breaking capacity- 10kA with C characteristics [Make : Siemens / other equivalent approved]
On delay timer [Make : GIC / Approved Make]
Voltage monitoring Relay (OV/UV) [Make : Seimens / Approved Make]
6 Window Microprocessor Based Alarm Annunciator [Make : Minilec ; Model-1 0B 6S P0)
Indicating LED (G) [Make : L&T / Seimens / Approved Make]
Indicating LED (B) [Make : L&T / Seimens / Approved Make]
230 Volt AC Electronic Hooter.
100 Watt Space Heater(SPP-22)
Thermostat for Space Heater.
1.1 KV grade 2.5 sq mm (FR) PVC Insulated (Unsheathed) single core multi strand Copper wire. [Make : Mescab / other equivalent approved)
1.1 KV grade 1 sq mm (FR) PVC Insulated (Unsheathed) single core multi strand Copper wire. [Make : Mescab / other equivalent approved)
Repairing of the existing panel(PDB Panel, and ATS panel 1 & 3) by fitting of the above supplied materials (as in item no 2.00, 3.00 & 4.00) and sevicing spares in existing position making internal wiring and connection by supplying all fixing materials such as copper socket, screws, nut-bolts, washers, cable tie, pvc tape, printing ferrule, PVC duct with cover etc. and testing the same as per & up to the entire satisfaction of EIC..
GST @18% of Total Value in Amount
CESS @1% of Total Value in Amount
TAMAL ENTERPRISE (BID ID -5952432)
INDIA ENTERPRISE (BID ID -5958535)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .