Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | ₹5.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹5.0 Cr+₹25,231.52 (0.05%)Rejected-AOC | ₹5.0 Cr+₹25,231.52 (0.05%) | L2 | Rejected-AOC Higher |
| 3 | Not Admitted-Fee/PreQual/Technical CHILIALANA RANIKHET DISTRICT ALMORA | ALMORA | UTTARAKHAND | 263601 | - | - | Not Admitted-Fee/PreQual/Technical Others-As per attached document |
Tender Value
₹5.0 Cr
EMD Value
₹10.0 L
Closing Date
6 Feb 2024, 6:00 pmClosed
Chief Engineer kumaun, RWD Bhimtal Nainital
Chief Engineer kumaun, RWD Bhimtal Nainital
Construction of Multi Level Parking at Hat Kalika Mandir, Gangolihat, District Pithoragarh (Uttarakhand)
2024_RES_67883_1
letter no. 936 dated 1-01-2024
Open Tender
Civil Works
Item Rate
360 days
Gangolihat
Please refer tender document
5 documents required · 5 mandatory
₹5,900
tender fee Rs. 5000 D.H- 0515008000100
₹10.0 L
13 Mar 2024
20 Jan 2024
7 Feb 2024
20 Jan 2024
6 Feb 2024
20 Jan 2024
20 Jan 2024 - 6 Feb 2024
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying cement concrete in plain window sills, fillets etc upto floor five level, excluding the cost of centring, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting, ropping etc. and removal of form foundation,footing,bases of columns,etc.for mass concrete
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. 40mm thick with 20mm nominal size stone aggregate. complete.by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 C/F Sand.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete Fixed to steel windows by welding. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing panelled or panelled and glazed shutters for d and clerestory windows including ISI marked black enamelled M.S necessary screws excluding panelling which will be paid for separa 30 mm thick shutters
windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.With 12 mm mild steel U beading. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc 250x16 mm as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc 250x10 mm. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc 125 mm . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Colour washing such as green, blue or buff to give an even shade New work (two or more coats) with a base coat of white washing with lime as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Finishing walls with water proofing cement paint of required shade New work (Two or more coats applied @ 3.84 kg/10 sqm). as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st conforming to IS :15622 of approved make in all colours, shades, exceptquality laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
Treatment of soil under existing floors using chemical emulsion@ one litre per hole, 300 mm apart including drilling 12mm diameter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1%concentration
S/F G.F.R.C.wall tiles over 12 mm thick 1:3 cement sand motar and joining with grey cement slurrly including jointing with white cement.
S/F of G.R.C. jali 30 mm thick one side finished all cost complete all cost complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (75 mm diameter )
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (110 mm diameter )
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Coupler 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved each design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete. 110 mm. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing to the inlet mouth of rain water pipe each cast iron grating 15 cm diameter and weighing not less than 440 grams. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing ball valve (brass) of approved quality complete. High or low pressure with plastic floats. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given 20 mm nominal bore
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. as per direction of Engineer -in- charge, work to be execuated as per specification a rate of above given (Flexible pipe 32mm dia)
Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall -Iinternal work 15 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 20 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture 150 mm diameter as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded ) 150 mm diameter S.W, pipe as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully trap grade 'A'' complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With F.P.S. Bricks class designation 75 as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finished with a floating coat of neat cement complete as per standard design : as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given (With F.P.S. bricks)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer) Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Random Rubble Masonary laid dry in breast wall,retaining wall, cu.m parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications) as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4)
PL Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .