Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L1 | Accepted-AOC accept | |
| 2 | L2₹24.7 L+₹1.2 L (5.21%)Rejected-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L2 | Rejected-AOC accept | |
| 3 | L3₹28.1 L+₹4.7 L (19.9%)Rejected-AOC | L3 | Rejected-AOC accept |
Tender Value
₹10.3 L
EMD Value
₹25,900
Closing Date
12 Apr 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Providing LWSS to Jalet Bhati Sandroan covered under JJM in Tehsil Jaisinghpur Distt. Kangra
2022_HPIPH_59135_1
THL-KNG05-729 (668-722 dated 05.04.2022)
Open Tender
Civil Works - Others
Item Wise
180 days
Providing LWSS to Jalet Bhati Sandroan covered und
Please refer Tender documents.
9 documents required · 9 mandatory
₹400
₹25,900
Yes
13 Jul 2022
5 Apr 2022
13 Apr 2022
5 Apr 2022
12 Apr 2022
5 Apr 2022
120 days
Amount
Excavation in foundation trenches etc.( for pipes and pits)up to all depths in all kind of soil such , as pick work, jumper work saturated soil including bailing or pumping out water, blasting soft/hard rock or chiselling soft /hard rock where blasting is prohibited in all leads & lifts including triming & dressing of sides levelling of beds to correct grade including shorting struttering planking timbering and dewatering where ever required stacking usable/unusable material / soil separately and after laying jointing and testing of pipes returning the usable soil in trenches in 15cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated earth as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of a diversion for traffic night signals,fixing caution boards crossing over trenches for access to houses fencing etc. as per direction of Engineer-in-Charge with in all leads and lifts.
Laying, jointing & testing of GI pipe with circumfrential butt welded joints by electrical arc welding ( welding thickness shall be equal to pipe wall thickness) steel flanged pipes after every 100 mtr of pipe of following diameter Conforming to IS 1239-1990 (Part-II), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and febrication of reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (Two inner & one outer), where ever required as per direction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately) and all operations such as cutting, welding, jointing, fabrication of tees i.e. lowering and laying in excavated trench to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the entire satisfaction of the Engineer in charge. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes and all the specials ( If damaged during laying & jointing operation of pipe) made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing, D.P. test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts.
G.I. ( M. Class) pipe 65mm dia with wall thickness 3.60 mm of , (FT-17) outer dia 60.80 mm , at every 100 mtr pipe flanged from RD 0 to 650 = 650 Rmt
G.I. ( M. Class) pipe 65mm dia with wall thickness 3.60 mm of , (FT-5) outer dia 60.80 mm , at every 100 mtr pipe flanged from RD 650 to 1050 =400 Rmt
Providing MS flanges (In pairs) for the joints of G.I. pipes mentioned as below and same shall conform to BIS 6392-1971 ( latest with up to date amendments) including the cost of nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets conforming to relevant BIS standards and it shall also include carriage of materials within all leads and lifts complete in all respect to the best satisfaction and direction of Engineer in charge.
G.I. ( M. Class) pipe 65mm dia with wall thickness 3.60 mm of , (FT-17) outer dia 60.80 mm , at every 100 mtr pipe flanged from RD 0 to 650 = 650 Rmt/100=7 Nos
G.I. ( M. Class) pipe 65mm dia with wall thickness 3.60 mm of , (FT-5) outer dia 60.80 mm , at every 100 mtr pipe flanged from RD 650 to 1050 =400 Rmt/100=4 Nos
Booster stage;- Supply of submersible pumping set of (KSB /Kalama/Kirloskar/Johnston/Cromption/Lubi) make conforming to BIS; 5659-1970 latest suitable for lifting clear water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:
Total Head,139.44 Mtrs,ii,Discharge required from each pump 1.80 LPS for each pump ( One Will act as stand by).,iii,No. of pump required 2.00 Nos. One act as stand ,by,iv,Location of the site of installation of machinery.The site is located at a distance of 65 Kmts from Palampur.v,The Altitude of installation.The altitude of place is 700 mtrs above MSL,vi,Type of current.AC Three phase supply with,vii,Rate Voltage 415+ 10%,viii,Type of water and its sourceClear water,ix,Charactristics of water.a)Ambient Temperature dig.c20 dig. C,b)Turbidity NTU,NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,x,Depth of P/Well3 mtrs,xi,LWL in P/ well mtrs.,xii,Dia of Bore,xiii,Maz draw down,xiv,Static water level in S/Well mtrs,xv,Center line level of Pump 102.70 mtrs,xvi,Discharge level of highest point 227.33 mtrs,xvii,Static head in Mrs 124.63mtrs.xviii,Length of R/Main (Including Column Assembly) 1050 mtrs.,xix,Dia of Rising main 65 MM,xx,No of working hours per day 16 Hours,xxi,Limit of pump operation. (-) 15 % (+) 10% of total head,xxiii,R.P.M. of pumping set. 2900 RPM ( or to be specified by the tenderer),xxiii,Test run. 16 Hours continueously for 7 days
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast steel double flanged sluice valve65 mm dia class PN1.6 confirming to BIS-780-1984 (to be provided on R/main side) capable of with standing nominal seat test pressure of 16 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve 80 dia class PN 1.6 vconfirming to BS 5312-1984 having bye pass arrangement (to be provided on R/main side) and shall be suitable for withstanding nominal seat pressure of 16 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 4.00 mm^2 ( From HPSEB Meter to Switch &Starter).
On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses.
Supply of standarad make 65 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/Laying Column assembly of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. Column assembly =65 mm dia G.I.flanged pipe(medium grade) NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pump (1 working and 1 Stand By ) of the rating . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges.
Energy Saving Variable Frequency Starter of Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens
Main incomer MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
LED On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.
Slector Switch for Auto and manul Operation
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should bo proper protection in case of any voltage surge and distortions.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. Make: Aarmation Electric Private Limited/MAS/ELLES
Power and Control wiring and Busbar
Installation, Commissioning and Software Development
Surge suppressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
Power quality monitoring & controling realy with Control Contactor to safeguard the Electronic & Electric elements
Independent Control panel with swithch fuse unit and fuses of Suitabvle Amperage to eliminate the kitkat fuses of HPSEB Make: Aarmation Siemens/Schneider/L&T
PLC (Programmable logic controller ) with appropriate digital and anlog inputs and output to give automatic command to Star Delta Starter panel/ Energy saving variable frequency starter Make: Aarmation Bechoff Automation/Rockwell Automation
Electronic realy card 8 channel
SMPS 4.5 Amps to energise PLC system
HMI (Humen Machine Interface) 7" display for Monitoring and Contriling of Submersible pumps Make: Aarmation Bechoff Automation/Rockwell Automation
Control MCB for Automation System
Level Sensor to indicate the water level of tank remotely
Shieldede data Cable for Communication of level Sensor with PLC
Installation and Commissioning and software Development for all above item complete all respect Engineer-in-charge
Stage-1st ( Old ) :- Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /Lubi /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.20 HP Each (2x 20 HP= 40 HP)
Total Head,283.39Mtrs.,ii,Discharge required from each pump.,3.55lps,iii,No. of pump required,2.00 Set (One act as stand by),iv,Location of the site of installation of machinery,The site is located at a distance of 65 Km from Palampur.,v,The altitude of installation.700 MSL.,iv,Type of current.AC three phase supply with freqduency of 75cycle per second.,v,Rate Voltage,415V + 10%,vi,Type of water and its source,Clear water.,vii,Charactristics of water.a)Ambient Temperature dig.c,b)Turbidity NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of well assembly,xvi,No. of working hours per day,16.00Hours.,xvii,Length of Rising main,2670Rmts.,xviii,Dia of Rising main,65 mm,xix,Limit of pump operation.In the completem Range of (-)75% .,xx,R.P.M. of pumping set.2900 RPM (or to be specified by the tenderer).,xxi,Test run.16Hours contineously for 7 days.
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast steel double flanged accutated sluice valve of class ASA-300 confirming to BIS-1414 (API-600) (to be provided on delivery side) of equal size to one dia more than the dia of delivery of pump and capable of with standing nominal seat test pressure of 52 kg/cm².
NOTE:-The Cast steel sluice valve shall conform to BIS:780-1984 for 50 to 300mm dia & BIS:2906-1984 for 350 to 1200mm dia ( latest edition). However if seat pressure exceeds the limits prescribed in above mentioned BIS, then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 52 Kg/cm² as per BS 1414 (API 600) .
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on delivery side) of size one step higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 52kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on Rising main) of 80 mm and shall be suitable for withstanding nominal seat pressure of 52 kg/cm².
NOTE:- The Cast steel reflux valve shall conform to BIS: 5312-1984- Part-I ( latest edition). However if the seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 21 Kg/cm² as per BS 1868 (API 600)
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I double flanged sluice valve class PN-1.6 confirming to BIS 780-1984 to be provided on Suction side of size one dia higher then the suctrion size of pump capable of withstanding nominal seat pressure of 16.32 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 10 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 6 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe XXX mm dia = to be specified by the Tenderer
Delivery pipe XXX mm dia = to be specified by the Tenderer
Common header = XXX mm dia
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries).Note. The strip size shall be 20x3 upto 18.5 KW . 25x3 for 18.5 to 37 KW to 55 KW and 32x5 beyond 55 KW.
Errection of all equipments including cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Supply , Installation, Testing and Commissioning of Energy Saving Variable Frequency Starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 20 HP . Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators, Power Quality Monitoring & Controlling Relay at the Incomer Feeder, Should be fitted with Surge Suppressor Device suiatble to protect against class-1 & 2 surges. Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec
Energy Saving Variable Frequency Starter of 20 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to monitor & control the frequecy of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 Degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/Bechoff/Bosch/Rockwell
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens
Main incomer MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.
LED On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc.
Slector Switch for Auto and manul Operation
Input Choke of required HP for Energy saving variable frequency Starter which should be installed at the input of Energy saving variable frequency starter, so that there should bo proper protection in case of any voltage surge and distortions.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. Make: Aarmation Electric Private Limited/MAS/ELLES
Power and Control wiring and Busbar
Installation, Commissioning and Software Development
Surge suppressor device with isolating MCCB to eliminate the power surges due to lightening and system surges.
Power quality monitoring & controling realy with Control Contactor to safeguard the Electronic & Electric elements
Independent Control panel with swithch fuse unit and fuses of Suitabvle Amperage to eliminate the kitkat fuses of HPSEB Make: Aarmation Siemens/Schneider/L&T
SANJAY SAINI
Sanjeev
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .