| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-Finance 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-Finance Lowest quoted value. | |
| 2 | L2₹40.8 L+₹2.4 L (6.20%)Rejected-Finance 620 DIAMOND HARBOUR ROAD BEHALA INDUSTRIAL ESTATE PLOT NO F A KOLKATA 34 | KOLKATA | WEST BENGAL | L2 | Rejected-Finance High quoted value. | |
| 3 | L3₹41.5 L+₹3.0 L (7.93%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance Higher quoted value. | |
| 4 | L4₹41.9 L+₹3.4 L (8.97%)Rejected-Finance | L4 | Rejected-Finance Highest quoted value. |
Tender Value
Refer Docs
EMD Value
₹77,466
Closing Date
20 Aug 2024, 4:00 pmClosed
SE,SEC,PWD
Office of the Superintending Engineer SOUTHERN ELECTRICAL CIRCLE, 2nd FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059.
Construction of 100 bedded Tourist lodge building at Gangasagar Sagar Block in the district of South 24 Parganas Balance Work SITC of Air Conditioning System
2024_WBPWD_716673_1
WBPWD/SESEC/eNIT-03/24-25
Open Tender
Electrical Work/ Equipment
Item Rate
90 days
Gangasagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹77,466
Superintending Engineer SEC PWD
9 Sept 2024
18 Jul 2024
22 Aug 2024
18 Jul 2024
20 Aug 2024
26 Jul 2024
25 Jul 2024
Amount
Supply & Delivery of Non-inverter type High-wall Split-type Air-Conditioner having following specification: Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] Cooling Capacity - 5.3 kW (Minimum) , IS Compliance - IS-1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard), as directed by EIC. i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3mtr. ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: O.General/Daikin/Mitsubishi Electric]
Supply & Delivery of Non-inverter type High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 7.0 kW (Minimum) , Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Daikin/Mitsubishi Electric] [For Multipurpose Hall]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per Direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of above AC machines. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm, 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast/Finolex)
Supply Fixing of 2000W, 5 star rating, 10 Liters, Porcelain Enamel Glass Lined tank Storage Water Heater (Gyser) with Glasslined Double Ceramic Heating Elements, Scale Guard system, 3 mm. (min.) PUF Insulation, , Advanced 3 Level safety & Temperature control knob. The Heater should have Corrosion free, Shock proof outer body, 8-Bar Pressure and with HOT and COLD line Flexible Hose pipe inclu.all required fixing arrangement as per direction fo EIC. (Make - Bajaj / Havells / Crompton/VENUS/AoSmith)
Supply Fixing of 2000W, 5 star rating, 15 Liters, Porcelain Enamel Glass Lined tank Storage Water Heater (Gyser) With Glasslined Double Ceramic Heating Elements, Scale Guard system, 3 mm. (min.) PUF Insulation, , Advanced 3 Level safety & Temperature control knob. The Heater should have Corrosion free, Shock proof outer body, 8-Bar Pressure and with HOT and COLD line Flexible Hose pipe inclu.all required fixing arrangement as per direction fo EIC. (Make - Bajaj / Havells / Crompton/VENUS/AoSmith)
Note 01 : Any other item or items left out from BOQ but essentially required for successful completion of the work may be raised for inclusion in the scope of work during pre-bid meeting.Otherwise bidder has to consider left out items deemed to be included in the scope of work. Bidders are advised to visit the site and and quote the price -accordingly. Note 02: The system shall be tested and commissioned by a qualified competent, trained engineer or technician. Note 03: Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules The defect liability period (DLP) of the aforesaid work will be for the period of THREE (03) years from date of completion.
WEATHER MAKERS INDIA
Lyric International
TRANSTECH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .