GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2026_MES_799483_1
GE MAINT EZHIMALA 8923
Open Tender
Civil Works
Item Rate
120 days
Ezhimala
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹89,900
Yes
19 Nov 2026
19 Nov 2026
17 Dec 2026
19 Nov 2026
11 Dec 2026
4 Dec 2026
19 Nov 2026 - 26 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fix Sheet metal enclosures with MCB single pole 20A, 240 V with a two pin and earth plug and socket complete all as specified and directed. | 54 | Each | - | - |
| 2 | Material and Labour for submain wiring with two single core Unilay- FRLS PVC insulated flexible copper conductor cable of size 2 runs of 4.0 sq. mm and one single core Unilay- FRLS PVC insulated flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in & including PVC casing and capping ISI marked , laid and fixed over walls/ceiling/floors and making good the disturbed surfaces to match with existing specification all as specified and as directed. | 486 | RM | - | - |
| 3 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and suitable for 2 ton AC complete and directed. | 54 | Each | - | - |
| 4 | Supply, install, Test and commissioning Hi wall split type Air conditioner unit (minimum 3.0 star) complete with indoor and outdoor units alongwith cordless remote control unit and filter for better indoor air quality of capacity 2.0 TR complete including copper piping suction line and discharge line along with thermal insulated cladding up to 3.0 mtr and power cable including the thermal insulation and makingthe hole in existing building for fixing the indoor unit complete and all as specified and directed.
Notes for item Ser No. 03 & 04:- The quoted rate are deemed to be inclusive of the following items. All these items shall be provided by contractor and no extra cost shall be paid on this account:-
(a) Contractor may visit the site before quoting of tender to assess the actual requirement of works and no extra cost will be entertained in this account. (b) Indoor unit wall mounted with blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water.
(c) Outdoor unit comprising of compressor with motor, air cooled copper condenser with fan and motor unit shall be installed outside the building/on roof top by using supporting clamps.
(d) Refrigerant copper pipe for suction and discharge line with insulation, condensing water drain pipe & protected by suitable size of PVC conduit 20mm dia medium grade upto 3m with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cables upto 3m as per site requirement. (e) Making good the disturbed surface to match with the existing surface after completion of installation work etc. (f) Half yearly complete servicing upto 01 years (Checking refrigerent pressure, loose connection, leakage of refrigerant, topup of refrigerant if required, servicing and cleanning of PCB) will be provided by OEM and no extra amounts will be paid on this account. (h) Contractor should ensure proper safety arrangements as per norms. Wearing safety belts and helmets are mandatory. A penalty of Rs.1000 per day will be recovered from contractor if safety norms are not followed. (j) Electrical cable required to connect outdoor unit and indoor unit to voltage stabilizer. (k) Manufacturing year of product shall be 2026 or after. | 54 | Each | - | - |
| 5 | Supply and install stand for outdoor AC unit suitable for 2.00 TR AC wall mounted/Floor mounted complete and all as specified and as directed | 54 | Each | - | - |
| 6 | Supply and joint copper piping suction line and discharge line along with thermal insulational cladding with power cable beyond 3 mtrs suitable for 2 TR AC as given in item no 4.00 complete all as specified and as directed | 108 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.12 MB
BOQ_896989.xls
BOQ • 0.31 MB
TenderDocument8923.pdf
Tender Documents • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .