Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC BHATI ABHOYNAGAR WEST VIVEKANANDA CLUB ROAD NEAR HOUSE OF DOCTOR GOURISHANKAR CHAKRABORTY P O AGARTALA TRIPURA WEST PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹6.3 L+₹10,050.20 (1.63%)Rejected-Finance | L2 | Rejected-Finance QUOTED HIGH | |
| 3 | Rejected-Technical C O MR M K BHOWMIK NEAR TAPAN VARIETIES JOYNAGAR 06 AGARTALA TRIPURA W 799001 | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical Not Recommended due to not enlisted in requisite category |
Tender Value
₹6.2 L
EMD Value
₹12,360
Closing Date
9 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AGARTALA
AGE (I) AGARTALA PIN 901184 C/O 99 APO
PROVN OF 01 X FOL STORAGE ROOM IN WKSP AND PROVN OF 04 X SECURITY LIGHTS MOUNTED ON POLE ALONGWITH PERIMETER OF SIG COY AT MIL STN AGARTALA
2023_MES_625398_1
8488/E8
Open Tender
Civil Works
Item Rate
180 days
AGARTALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) AGARTALA
₹12,360
Yes
5 Mar 2024
11 Nov 2023
11 Dec 2023
11 Nov 2023
9 Dec 2023
25 Nov 2023
Amount
Schedule'A' Part-I: B&R works
Surface excavation n.exc 30 cm deep and averaging 15 cm deep
Excavation in trenches n.exc 1.5 M wide and n.exc 1.5m deep as in soft/loose soil for foundation etc or for shaft walls, cesspit, manhole etc n.exc 10Sqm on plan and n exc 1.5 m depth and getting out.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.in soft/loose soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point
M & L for Cement Concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in foundation filling and mass concrete.
M&L for cement concrete Type C2 1:3:6 ( 40mm graded aggregate ) in foundations,filling and mass concrete all as specified and directed.
M&L for 10mm dia and over mild steel TMT bars cut to length bent to shapes as required including bending cranking and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified..
All as per item No.6 but 5mm to 10mm dia as in Stirrups, spaces & binders complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter.
M&L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete in Square, rectangular or polygonal etc.
M&L form work to rough finished flat surfaces of sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves etc of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete in Square, rectangular or polygonal etc.
M & L reinforced cement concrete (Nominal Mix) 1:2:4 20mm graded aggregate type B1 for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate) columns, pillars, piers, posts and struts rough finished.
M&L for reinforced cement concrete type (Nominal Mix) 1:2:4 20mm graded aggregate type B1 using 20mm graded stone aggregate as in slab supported in walls, beams, cantilivers, bressummers, lintels over 11.5m Span all as specified and directed.
Material and labour for brick work with locally available sub class ‘B’, old size, best quality bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:4) all as specified and directed.
M&L for rolled mild steel as in roof trusses ( framed) trussed, purlins, crane gamtries, rail,and fastening and heavy brackets framing (Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc conforming to Fe 410-W(Gde-E250) quality-B complete all as specified and directed.
Material and labour PCC 1:3:6 type C2 using 40 mm graded aggregate as in plinth protection 75 mm thick finished fair and even w/o using extra cement.
M & L for broken brick aggregate hard core of gauge not exec 63 mm deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed toa true surface all as specified and directed by Engr-in-charge.
M&L for sand filling under floors or in foundation including watering and consolidation spreding and levelling in layers n.exc 25 cm thick complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L PCC 25 mm thick type B-1, 1:2:4 ( 20mm graded aggregate) as in floor as per leveling course all as specified and directed.
M&L for 15 mm thick rendering in CM 1:4 on fair faces brick work or concrete surfaces mixed with water proofing compound (WPC shall be measured and paid seperately)
M&L for 10mm thick plaster on fair faces of brick or concrete surfaces in CM 1:6 complete all as specified.
Supply of Liquid water proofing compound
M & L for preparation of new plastered surfaces by applying 3mm wall care putty and applying two coats of oil bound distemer over a coat of primer on new plastered surfaces .
M&L for applying two coats of cement base paint on new plastered surfaces of wall over a coat of primer after preparation of new plastered surfaces to receive paint complete all as specified and directed by Engr-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws as specified.
M&L mild steelwork such as grills, guard bars etc and similar work conforming to Fe290 GDE E-165
Cutting bolls in to brick wall for inserting hold fast & making good dismantled portion in cm (1:3) or PCC (1:2:4) type B1, exe half brick but not exe 1 brick.
S & F 4 mm thick sheet glass ordinary quality & glazing with oil putty in squares n exe 0.5 sqm in each pane
S&F pressed steel frames for doors of (size 125X60mm) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, complete all as specified and directed.
M&L for 2 coats of synthetic enamel paint over coat of red oxide zinc chrome on steel surfaces over 10cm width or girth including preparation of new surfaces.
M & L for framed work as in doors or gates of angles or other section with gussets plates, rails braces, etc.,complete drill for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel, sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete.
M & L for 1.25 mm thick 750 g of zinc (Spelter) coating per sqm both side inclusive; plain, galvanised, mild steel sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) welded or soldered joints are provided.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay complete all as directed.
M&L for two coats of black japan paint over a coat of red oxide zinc chrome on steel surfaces n.exe 10 cm width or girth including preparation of new surfaces.
S&F Mild steel sliding door bolts of size 300mm length of bolt, plate type, stove enamelled black with bright bolt not less than 12 mm dia with nad including a minimum of 6 bolts and nuts, four on bolt plate & two on staple plate.
Schedule'A' Part-I: E&M works
Material and labour for point wiring (concealed type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and including PVC conduit (medium grade) of adequate size with fittings and accessories as required at site including suitable size of GI boxes of thickness not less than 0.8 mm thick and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified as directed. Note for item Nos.1 to 4: (i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose, etc and also making good the disturbed surfaces are deemed to be included in unit rate. (ii) Cost of GI box of suitable size shall be deemed to be included in the qouted rate (iii) Cost of chase cutting for conduit wiring shall be included in the qouted rate
Material and labour for point wiring (concealed type) with PVC insulated 1100 volts grade FRLS unsheathed single core multi-stranded copper conductors 1.5 sqmm (nominal area) for phase, neutral and 1.5 sqmm PVC insulated unsheathed multi-stranded copper conductor cable for earth continuty conductor drawn through and in stove steel enamelled steel conduit of adequate size with fittings and accessories as required at site and earth continuty conductor shall be connected to common earth and earth dolly for one light/fan point controlled by one way switch complete all as specified as directed. Note for item Nos.1 to 4: (i) Cost of GI box of suitable size shall be deemed to be included in the qouted rate (i) Cost of chase cutting for conduit wiring shall be included in the qouted rate
Materials & labour for switch piano flush button 5/6 Amps single pole, 1 way 240 V ISI marked complete all as specified and as directed.
Materials & labourSwitch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Materials and labour for ceiling rose surface bakelite, 65 x 50mm, three terminals complete all as specified and as directed.
Supply & fixing MCB DB concealed in wall (Double door) SPN, 4 way , 200 A rated IP-43,IK-09, sheet steel with bus bar, din rail, neutral link and earth bar including taking down old DB with fitting & fixtures all as specified and directed.
Supply and fix MCB single pole 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed.
Supply and fix MCB single pole & neutral 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed
Material and labour for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below GL) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (Light grade) and 20mm dia GI pipe (medium grade) for watering and connected to control switch as directed including necessary earthwork as in soft/loose soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:1.5:3) type A1 cover slab duly reinforced with 8mm dia TMT bar @ 100mm C/C both way and two Nos lifting handle made of 12mm dia TMT bar and set in cement mortar (1:4), funnel, wire mesh, char coal or coke and salt in alternate layer, testing, etc complete all as specified in electrical plate No 5 of SSR Part-I.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting 2x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply, Laying,connecting,testing and commissioning of XLPE insulated and PVC sheathed ,armoured heavy duty UG cable with stranded alluminium conductors 10 sqmm x 2core,1100 Volt grade, laid in trenches / surface / wall / roof / pole / through pipe , including taking dwn old cable compleate all as specified and as directed Note :- (i) Pipe and bricks for cable protection and sand cushioning shall be measured and paid separately as per site .
Cutting hard standing / road for laying of cable / protection pipe complete all as specified and as directed.
Supply and lay GI pipe 50 mm bore (dia) light grade in trenches/road/surface/pole/wall crossing for protection of cable with necessary fittings as required complete all as specified and as directed.
Supply and fixing steel tubular swaged pole as per IS 2713 (Part 1 to 3) - 1980, type 410 SP-31 (09 mtr long ) complete with cast iron base plate final taper plug, pole cap, bolts/nuts, screws/washes, painting with two coats of black bituminous paint through out internally and externally upto planting depth and two coasts of black and white alternate strips 30 cm each upto 1.2 mtr from the ground level. The remaining external position shall be painted with two coat of aluminium paint including numbering to pole complete all as specified and directed. (Note:- Earth work, PCC work, shall be measured and paid separately.)
Material & labour for heavy duty armoured LT under ground cable of size 10 Sqmm, 4 core 1100 V grade PVC insulated ,PVC sheathed ,multi stranded aluminium cable of following size in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc including lugs for both ends and making good the disturbed surfaces complete all as specified and directed.
Material & labour in replacement of tubes of size 40 mm bore light grade galvanized with all fittings laid intrenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ as reqd ] of proper sizes complete for protection cables complete all as specified and directed.
Material & labour for replacement of rusted/corroted security light bracket made out of GI pipe of light grade 1.5 RMx40mm dia and 0.3RM x32 mm dia at one end for inserting of light fitting, properly shaped, bended, & fixed on the pole through MS flat by nut,bolt & washer of suitable sizes incl dismantling the old unsv existing one complete all as specified and directed.
Material & labour for 2 core standred cable 4 Sqmm size, 1100 volt grade, PVC insulated unsheathed aluminium cable from junction box to street light fitting and testing complete all as directed.
Supply and fixing loop in- loop out fuse junction box of internal dimention 250 x 200 x 105mm made of FRP sheet with weather proof canopy and locking screw fitted with and including 6 Amp MCB - 01 No, 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing , mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box all as specified and directed.
Excavation in trench exceeding 1.5 mtr depth and n.exc 3.0 mtr depth and getting out of soft/ loose soil / brick all as specified
Material & labour for sand cushioning for cable protection with dry river sand and punning to provide required cushioning for UG cable all as specified and directed
S & F bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed.
M & L for plain cement concrete (1:2:4) B1 type using 20 mm graded coarse stone aggregate for foundation/coping of poles complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details.
SHRI RAJESH DEY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .