Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.0 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹13.1 L+₹1.1 L (8.85%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹13.5 L+₹1.5 L (12.5%)Rejected-Finance 01 PURANA DAKKHANA CIVIL LINE GANDHI NAGAR BASTI UTTAR PRADESH 272001 | BASTI | UTTAR PRADESH | 272001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹13.5 L+₹1.5 L (12.5%)Rejected-Finance VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L4 | Rejected-Finance BEING 4 |
| Sl No | Description | Qty | Unit | avon electric engineering woks L2 | M M CONSTRUCTIONS L1 | M/S MAHIRA ENTERPRISES L4 | GEETA ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminum/ copper point wiring for light, fan, socket or power point etc complete with conduit including making good surface of wall, ceiling etc. complete all as specified. | 784 | Per Point | 15 ₹11,760 | 2 ₹1,568 Lowest | 2 ₹1,568 Lowest | 5 ₹3,920 |
| 2.00 | Taking down carefully sub main wiring (aluminum/ copper) complete with conduit/ batten and accessories including making good surface of wall, ceiling etc complete all as specified. | 632 | RM | 15 ₹9,480 | 2 ₹1,264 Lowest | 2 ₹1,264 Lowest | 5 ₹3,160 |
| 3.00 | M&L for point wiring using approved colour coding as per IS with 1100 volt grade 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC conduit heavy duty of size not less than 20 mm dia with all fittings, concealed in wall/ roof / ceiling including pressed steel concealed terminal boxes 1.2 mm thick 60 mm deep of required size with modular white cover plate with frame for housing switches/ sockets/ regulators etc. duly earthed with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as continuous earthing wire complete all as specified for one light/ fan controlled by one switch one way complete all as specified.
[Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.] | 50 | Per Point | 290 ₹14,500 Lowest | 310 ₹15,500 | 400 ₹20,000 | 350 ₹17,500 |
| 4.00 | All as per item No. 3.00 abve but for one light point controlled by two way switch complete all as specified. | 4 | Per Point | 290 ₹1,160 Lowest | 400 ₹1,600 | 400 ₹1,600 | 350 ₹1,400 |
| 5.00 | All as per item No. 3.00 above but for socket outlet 05 Amp on same board complete all as specified. | 20 | Per Point | 160 ₹3,200 | 230 ₹4,600 | 200 ₹4,000 | 150 ₹3,000 Lowest |
| 6.00 | All as per item No. 3.00 above but for socket outlet 05 Amp on independent board complete all as specified. | 20 | Per Point | 290 ₹5,800 Lowest | 310 ₹6,200 | 400 ₹8,000 | 350 ₹7,000 |
| 7.00 | All as per item No. 3.00 but for one bell/ buzzer point controlled by one bell push complete all as specified. | 15 | Per Point | 290 ₹4,350 Lowest | 320 ₹4,800 | 400 ₹6,000 | 310 ₹4,650 |
| 8.00 | All as per item No. 03 above but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board complete all as specified. | 20 | Per Point | 310 ₹6,200 Lowest | 400 ₹8,000 | 500 ₹10,000 | 400 ₹8,000 |
| 9.00 | M&L for point wiring using approved colour coding as per IS with 1100 volt grade 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn in existing conduit including all accessories after chasing/ concealed in wall/ roof / ceiling including pressed steel concealed terminal boxes 1.2 mm thick 60 mm deep of required size with modular white cover plate with frame for housing switches/ sockets/ regulators etc. duly earthed with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as continuous earthing wire complete all as specified for one light/ fan controlled by one switch one way complete all as specified.
[Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.] | 120 | Per Point | 290 ₹34,800 Lowest | 310 ₹37,200 | 400 ₹48,000 | 350 ₹42,000 |
| 10.00 | All as per item No. 9.00 abve but for one light point controlled by two way switch complete all as specified. | 30 | Per Point | 290 ₹8,700 Lowest | 350 ₹10,500 | 400 ₹12,000 | 340 ₹10,200 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 Sept 2025, 6:00 pmClosed
GE (AF) Bareilly
GE (AF) Bareilly-243002 (UP)
REPAIR/ MAINTENANCE AND OPERATIONS OF ELECTRICAL 3 PHASE METERS, WIRING, METER BOX, DBs, CHANGE OF MCBs ETC IN OTM, BP AND OTHER INSTALLATIONS AT AFS BAREILLY UNDER GE (AF) BAREILLY
2025_MES_725847_1
GE(AF)/BLY/T-35 of 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
Class-E Cat-b(i)
8 documents required · 8 mandatory
₹500
GE (AF) Bareilly
₹30,000
Yes
26 Nov 2025
12 Aug 2025
11 Sept 2025
12 Aug 2025
9 Sept 2025
27 Aug 2025
Amount
Taking down carefully aluminum/ copper point wiring for light, fan, socket or power point etc complete with conduit including making good surface of wall, ceiling etc. complete all as specified.
Taking down carefully sub main wiring (aluminum/ copper) complete with conduit/ batten and accessories including making good surface of wall, ceiling etc complete all as specified.
M&L for point wiring using approved colour coding as per IS with 1100 volt grade 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn through and including rigid non-metallic PVC conduit heavy duty of size not less than 20 mm dia with all fittings, concealed in wall/ roof / ceiling including pressed steel concealed terminal boxes 1.2 mm thick 60 mm deep of required size with modular white cover plate with frame for housing switches/ sockets/ regulators etc. duly earthed with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as continuous earthing wire complete all as specified for one light/ fan controlled by one switch one way complete all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
All as per item No. 3.00 abve but for one light point controlled by two way switch complete all as specified.
All as per item No. 3.00 above but for socket outlet 05 Amp on same board complete all as specified.
All as per item No. 3.00 above but for socket outlet 05 Amp on independent board complete all as specified.
All as per item No. 3.00 but for one bell/ buzzer point controlled by one bell push complete all as specified.
All as per item No. 03 above but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board complete all as specified.
M&L for point wiring using approved colour coding as per IS with 1100 volt grade 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade (IS:694) drawn in existing conduit including all accessories after chasing/ concealed in wall/ roof / ceiling including pressed steel concealed terminal boxes 1.2 mm thick 60 mm deep of required size with modular white cover plate with frame for housing switches/ sockets/ regulators etc. duly earthed with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FR-LSH grade as continuous earthing wire complete all as specified for one light/ fan controlled by one switch one way complete all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
All as per item No. 9.00 abve but for one light point controlled by two way switch complete all as specified.
All as per item No. 9.00 above but for socket outlet 05 Amp on same board complete all as specified.
All as per item No. 9.00 above but for socket outlet 05 Amp on independent board complete all as specified.
All as per item No. 9.00 but for one bell/ buzzer point controlled by one bell push complete all as specified.
All as per item No. 09 above but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 Amp socket outlet point on independent board complete all as specified.
S&F in repair metal flush box made of GI sheet with earth terminal including necessary cutting in wall and POP work as required for matching existing slot in wall for 1 Module complete all as specified.
All as per item No. 15.00 above but for Metal Flush box 2 Module.
All as per item No. 15.00 above but for Metal Flush box 3 Module.
All as per item No. 15.00 above but for Metal Flush box 4 Module.
All as per item No. 15.00 above but for Metal Flush box 6 Module.
All as per item No. 15.00 above but for Metal Flush box 8 Module.
All as per item No. 15.00 above but for Metal Flush box 12 Module.
S&F in repair modular plate white colour with frame for 1 module complete all as specified.
All as per item No. 22.00 above but for 2 Module.
All as per item No. 22.00 above but for 3 Module.
All as per item No. 22.00 above but for 4 Module.
All as per item No. 22.00 above but for 6 Module.
All as per item No. 22.00 above but for 8 Module.
All as per item No. 22.00 above but for 12 Module.
S&F in replacement of wall/ surface mounted type LED light fitting batten type complete with LED lamp 05 Watt (1 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable all as specified and as directed. Make :- Philips, Wipro, Havells
S&F in replacement of wall/surface mounted type LED light fitting batten type complete with LED 1x 20 Watt (4 feet long), extruded aluminium body with heat sink provided for efficient heat dissipation and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with 3 core twisted flexible copper conductor cable complete all as specified and as directed. Make : Philips Cat Part No BN 021C LED 20S PSU CW GR S2 / Havells Cat Part No : ENDURA LINEAR NEO BS 20W LED 865 SPC WH or equivalent make of Wipro.
S&F in replacement of wall / surface mounted type LED light fitting batten type complete with LED lamp 10 Watt (2 feet long), poly carbonate body and integrate electronic drive complete with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper conductor cable complete all as specified and as directed. Make : Philips Cat Part No BN 021 LED12S 6500 PSU GR / Havells Cat Part No : ENDURA LINEAR NEO BS 10W 865 SPC WH or equivalent make of Wipro.
S&F in replacement of recess mounted LED down lighter 18 to 20 Watt in powder coated/ aluminum die cast housing with integrated electronic driver complete including connecting up with three core twisted flexible copper conductor cable of suitable size all as directed. [Cat No. GLOWDLR18WLED857S of make: Havells or Cat No. DN296B LED20S-6500 PSU WH of make: Philips or Cat No. BZSLO nxt 18L LED WH SD of make: Bajaj]
S&F in replacement of LED bulk head light fitting 10W with IP-65 protection complete including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to fitting all as directed. [Cat No. 'LBHP-10-CDL' of make: CG/ 'BIBWP 10W LED' of make Bajaj or its equivalent in Philips]
S&F in replacement of LED Bldg street light fitting 35 - 36W, IP 65 made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP65 protection, roadway luminaire with high power LED as light source 1 x 35/36 Watt, LED 6000K, complete with all accessories internally pre-wired complete all as specified and as directed. Make :- Philips Model No BRP046 LED 36 CW MR S1 PSU GR, Havells Model No ENDURA CITY LITE PLAT PLUSS I35W LED 757 SAS YBOPC, Wipro Model No Skyline Plus LR13- 501- XXX- 57-XX
S&F in replacement of surface mounted LED down lighter 18 to 20 Watt in powder coated/ aluminum die cast housing with integrated electronic driver complete including connecting up with three core twisted flexible copper conductor cable of suitable size all as directed. [Cat No. ENDURANEOHESURFA CEDLS21WLED857S of make: Havells or Cat No. SM251C LED20S- 6500 PSU WH of make: Philips or Cat No. BZSLOS NXT 18L LED WH SD of make: Bajaj]
S&F in repair modular snap switch type single pole 2-way 5/6 Amp complete all as specified.
S&F in repair bell push, flush type, single pole, one way, 5 Amps, 230 volt AC all as specified.
S&F in repair bell (ding dong) 230 volts AC circuit single pole complete all as specified.
S&F in repair modular snap switch 16 Amp one way 230 Volt AC, two modules.
S&F in repair modular snap switch 6 Amp one way 230 V AC, one module.
S&F in repair modular socket outlet 6 Amp multi pin socket for all pins 230 volt AC, two modules.
S&F in repair modular socket outlet combination 16 Amp and 6 Amp heavy duty 230 V AC, two modules.
S&F in repair modular type fan regulator electronic socket step type 120 W, two modules all as specified.
M&L in repair modular angle holder, insulated body with back plate with & including LED Lamp 7 Watt suitable for batten fittings complete all as specified.
S&F in repair street light bracket made of light grade GI pipe 32 mm bore and 0.50 mtr long duly bent to shape including 2 pairs of MS Clamps made out of 40 mm x 3mm mild steel flat, nuts, bolts, washers etc complete all as specified.
M&L for submain wiring with two single core 1100 volt grade FRLSH PVC insulated flexible copper conductor cable of size 2.5 Sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces all as specified.
M&L for submain wiring with two single core 1100 volt grade FRLSH PVC insulated flexible copper conductor cable of size 4.0 Sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces all as specified.
M&L for submain wiring with two single core 1100 volt grade FRLSH PVC insulated flexible copper conductor cable of size 6.0 Sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces all as specified.
M&L for submain wiring with two single core 1100 volt grade FRLSH PVC insulated flexible copper conductor cable of size 10 Sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 10 Sqmm as earth lead including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces all as specified.
S&F in replacement of flush mounting, factory made V TPN DBs-DPX-160 MCCB DB's, IP-43 protection-IK09 with metal door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and 24 Nos MCB, SP as outgoing etc including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. Make :- Legrand V TPN DB 8 Way Cat Part No 507752 or its equivalent in Schneider/ Siemens.
S&F for flush mounting, factory made V TPN DBs-DPX-160 MCCB DB's, IP-43 protection-IK09 with metal door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and 18 No MCB, SP as outgoing etc including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. Make :- Legrand V TPN DB 6 Way Cat Part No 507751 or its equivalent in Schneider/ Siemens
S&F for flush mounting, factory made V TPN DBs-DPX-160 MCCB DB's, IP-43 protection-IK09 with metal door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB as incomer and 12 No MCB, SP as outgoing etc including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed. Make :- Legrand V TPN DB 4 Way or its equivalent in Schneider/ Siemens
S&F in replacement of MCCB 125 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified.
S&F in replacement of MCCB 100 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified.
S&F in replacement of MCCB 160 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified.
S&F for sheet steel powder coated distribution board TPN 4 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed.
S&F for sheet metal enclosure distribution board, single pole and neutral, AC, 240 volt, 08 way, double door with 100 Amp rated copper bus bar and metal door with IP - 43 and flush to wall including taking down existing unserviceable DB embedded in wall, grouting the new DB and making good the disturbed surfaces and applying finishes to match the existing all as specified and as directed.
S&F in replacement of MCB 6 to 32 Amps, SP, 240 volts, 'B' curve with rupturing capacity 10 KA including providing thimble for out going cables.
S&F in replacement of MCB 63 Amps, TPN 415 volts, 'B' curve with rupturing capacity 10 KA including providing thimble for out going cables.
S&F in replacement of MCB 40 to 60 Amps, SPN, 240 volts, 'B' curve with rupturing capacity 10 KA including providing thimble for out going cables.
S&F in replacement of single pole and neutral enclosure with two pin and earth plug and socket complete with a single pole MCB 20 Amps complete in sheet metal enclosure complete all as specified.
M&L for making horizontal hole by mechanical boring under hard standing, pavements or roads etc for insertion of GI pipes 40 mm to 80 mm bore and making good the disturbed surface complete all as specified. [Note: GI pipe shall be mneasured and paid separately].
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core including taking out existing unserviceable cable all as specified.
All as per item No. 63.0 above but of size 35 Sqmm 3.5 core.
Excavation in trenches in soft/ loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out for laying of cables all as specified.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick all as specified.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified.
M&L for dry sand cushioning for protection of under ground cables (8cm before laying the cable and 15cm after laying the cable in trenches) complete all as specified.
M&L for well burnt sub class 'B', bricks using old size laid dry, flat, over the cable abutting each other, length of brick equal to width of brick all as specified.
S&F in repair 40 mm bore light grade ISI marked GI tubing laid in trenches or inserting in horizontal boring for cable protection including fixing with MS clamp and nut bolts complete all as specified.
M&L in replacement of earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep) below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified including 15 mm GI tubing medium grade and necessary fitting for protection of GI wire including laying of charcoal dust and common salt in alternate layer, PCC pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 8 mm dia TMT bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick in cement mortar (1:6) externally upto 150 mm below ground level , GI funnel with 20 mm dia medium grade GI pipe for watering and wire mesh including excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part-I and connected to earth test point including testing and marking bldg Nos and writing test results on a 3.0 mm thick painted mild steel earth pit marking plate (200mm x 100 mm) duly welded with a 450mm long 10mm dia round mild steel rod fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system all as specified an directed.
avon electric engineering woks (BID ID -3420603)
GEETA ENTERPRISES (BID ID -3418792)
M/S MAHIRA ENTERPRISES (BID ID -3420107)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .