Director
NIT Calicut, NIT Calicut Campus PO, Kerala, 673601
Laying 1 No. Cable from Substation 3 to the panel near Guest House
2024_NITC_841541_1
Engg/EMU/TA6/0001/Guest House Cable Change
Open Tender
Electrical Works
Item Rate
60 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹45,200
Yes
31 Jan 2025
26 Dec 2024
13 Jan 2025
26 Dec 2024
10 Jan 2025
26 Dec 2024
Amount
Supply and making end termination with brass compression gland and aluminium lugs for 3.5C X 240sq. mm (62mm) size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for 3.5C X 240 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying of one number 3.5C x 240 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.
Supplying and laying of 160 mm dia (OD-160 mm & ID-135 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 185 sq. mm and upto 400 sq. mm (3.5C x 240 Sq.mm) size in the existing masonry open duct as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 185 sq. mm and upto 400 sq. mm (3.5C x 240 Sq.mm) direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 30 cm X 30 cm at the bottom and 25 cm X 25 cm at the top with a thickness of 10cm including inscription duly engraved and painting as required.
Supply and laying of 5 inch 125 NB GI pipe (medium class B) on ground with all accessories like socket, bend, couplers with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., and making good the damages of road with concrete mixture of 1 : 2 : 4 including watering & ramming etc. as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5C x 240Sq.mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
Supplying and fixing cable details tags using Aluminium sheet of size 10 cm X 3 cm X 2 mm or nearest size on the existing cable.
Supplying and fixing 250 Α, 25 KA, 4 pole МССВ with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, extended/direct ROM, spreading insulation reinforcement, industrial work on busbar and panel to accomodate the MCCB etc. as required as per the site condition and making good the damages and insulation.
Supplying and fixing 315 Α, 36 KA, 4 pole МССВ with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, extended/direct ROM, spreading insulation reinforcement, industrial work on busbar and panel to accomodate the MCCB etc. as required as per the site condition and making good the damages and insulation.
Electrical Schematic drawing in Autocad and pdf format along with physical copy of the same for Electrical inspectorate approval (along with seal,signature and license details of A class contractor) and complete assistance in obtaining the necessary approval from the Electrical inspectorate, ensuring that all compliance requirements and procedures are properly followed etc as required.
Marking on existing panel boards using paint (incoming, outgoing, cable size, switchgear rating etc) as required/ instruction from Engineer in charge.
Charges for cleaning and spray painting the existing Panel boards with two coats of suitable colour (Grey) paint, over a coat of primer in installed position and marking the identification of switches with white paint etc, as required/ instruction from Engineer in charge.
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement, watering pipe and with suitable amount (30kg) of earthing compound (EXCEL compound or equivalent) etc. as required.
Supply and laying one number of the 8 SWG good quality bare copper wire along the cable with connections etc. as required.
Power Care Electrical (BID ID -3152851)
NATIONAL ENGINEERING COMPANY (BID ID -3151673)
LAMOS TECHNOLOGY SOLUTIONS PVT LTD (BID ID -3152841)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .