Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹7.9 L (5.82%)Rejected-AOC | ₹1.4 Cr+₹7.9 L (5.82%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical JAIN TEMPLE ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | DIMAPUR | NAGALAND | 797112 | - | - | Rejected-Technical Due to adverse remark in Work Load Return. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Due to non-enlistment in eligible class. |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
14 Jun 2022, 6:00 pmClosed
CWE (AF) Borjhar
HQ CWE (AF) Borjhar Military Engineer Services PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele No. 0361 2841626
ADDN/ALTN TO MD ACCN (PHASE-II) AT KUMBHIRGRAM
2022_MES_523100_1
CWE(AF)/KUM/TOKEN-65 OF 2021-22
Open Tender
Construction Works
Item Rate
360 days
Kumbhirgram
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
AGE (I) (AF) Kumbhirgram
₹2.2 L
Yes
2 Aug 2022
10 May 2022
16 Jun 2022
10 May 2022
14 Jun 2022
31 May 2022
Amount
SCHEDULE 'A' PART - I: Disconnecting existing tanks, setting aside of capacity exceeding 250 litres and n exc. 500 litres (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as directed.
Description all as per Item No 1 above but exceeding 500 litres and n exc. 1000 litres complete all as specified and directed
Dismantling existing tanks of capacity exceeding 250 litres and n exc. 500 litres complete all as directed.
Description all as per Item No 3 above but exceeding 500 litres and n exc. 1000 litres complete all as specified and directed
S&F 500 ltrs rotational moulded polyethelene water storage tank tripple layer (Cylinderical vertical with closed top) including connecting up pipes securing access covers complete all as specified and as directed.
Description all as per Item No 3 above but capacity 1000 litres complete all as specified and directed
S&F ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball float valve screwed for iron pipe or brass ferrule of 20 mm bore of having minimum weight 210 gms complete all as specified and as directed.
Taking up or down 20 mm bore GI tubing and connections including cleaning for re-fixing or removal to store complete all as directed.
S&F GI tubing 20 mm bore, medium grade with all fittings such as bends, elbows, nipples, sockets, tees, unions, short pieces etc.and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Re-Fixing only old serviceable GI tubing 20 mm bore, medium grade with all new fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed.
S&F interlocking aluminium power coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and directed.
S&F 4 mm thick cement fibre ceiling board of Ocean Texture fixed to aluminium frame work complete all as directed.
Demolition of reinforcement cement concrete (RCC) of any description and in any position complete all as directed.
M&L for RCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in Fins, Facias, louvers, parapets and railings, newals, balustrade & the like, complete all as specified and directed.
Formwork to fins. Louvers, facias etc for fair finished surfaces of concrete complete all as specified and as directed.
Mild steel TMT bars 6mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Demolition of PCC (unreinforced) in ground floors and pavings n exc 15 cm thickness,(below or above ground level) complete all as directed.
M&L for 25 mm thick PCC (1:2:4) type B-0 with (using 12.50 mm graded crushed stone aggregates) as in flooring, finished even and rough to receive the top layers all complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for non skid ceramic joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on wall of any desription including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 10 mm thick screed bed in cement mortar (1:4) on vertical surfaces as in skirting complete all as specified and directed.
M&L for non skid ceramic joint free coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15 mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar (1: 4) on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base of 15mm thick in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar over cement screed base of 15mm thick in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
S&F modular kitchen cabinet made out of 18mm thick one side decorative lamination and other side balancing lamination sheet consisting of carcass 18mm thick PVC sheet and provision of shutters made out of 18mm thick one side decorative laminated PVC sheet including all required brackets, SS screws, installing concealed cabinet door hinges, rails, channels, internal fixtures, magnetic catch, stainless steel partitions (Baskets different utensils as required in kitchen) etc. The panel shall be fabricated using adhesive and screws where ever required. All the edges shall be covered with 2mm thick edge bonding tape or 90 degree edge bent finish complete all as specified and directed. MAKE : RAJSHREE
S&F solid PVC door frame of size 50x47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, wood grain printed supplied and fixed in opening complete as as specified and directed.
M&L for 12mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one side, fixed with screws to timber frame work complete all as specified and as directed.
S&F of factory made solid panel PVC cupboard shutter, 18 mm thick one side decorative lamination & other side balancing lamination sheet consisting of carcass 18mm thick PVC sheet of density 600 Kg/Cbm manufactured by an ISO:9001-2015 certified company & provision of shutters made out of 18mm thick one side decorative laminated PVC Sheet all required brackets 5.5 screws, installing concealed cabinet door hinges, rails, channels, magnetic catch internal fixtures etc. The panels shall be fabiricated using adhesive and screw where ever required. All the edges shall be covered 1mm thick edge bonding tape of 90 degree edge bent finish as per make and specification mentioned as per drawing and specification approved by Engineer-in-Charge. MAKE : RAJSHREE
S&F 75 mm size aluminium handles, cast type, anodised complete all as specified and directed.
S&F 75mm long Aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frame) exc. 1.5 Sqm each and n.exc. 4.00 Sqm each complete all as specified and as directed.
M&L for MS flat iron including cutting, riveting etc for fixing water tank grill case complete all as specified and as directed.
M&L for preparation of new steel surfaces n exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F 100 mm butt hinges medium weight cold rolled mild steel complete all as specified & directed.
Taking down tarfelt with tiles and cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50 m and n. exc. 100m including roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust complete all as directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound @ 3% by weight of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement complete all as specified and directed. (Note: Water proofing compound shall be measured and paid perarately under relevant item as supply only).
M&L for water proofing treatrment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bitumenous primer @ 0.25 ltrs per Sqm over plastered surfaces of roof incl parapet surface. (Note :- Bituminuous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd/STP ) (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3 mm thick weight not less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) APP bassed polymeric membrane shall be "MOPLY FP 3MM" manufactured by M/S Texsa India Limited/STP. (iv) Applying two coats of Aluminium paint over APP membrane.)
M&L for complete removal of existing treatment on wall and applying two coats of oil emulsion distemper over a coat of wall care putty and primer complete all as specified and directed.
Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed.
Supply only Integral water proofing compound.
SCHEDULE 'A' PART-II : Taking down carefully aluminum/copper point wiring (light, fan socket or power) including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc and keeping serviceable light fittings in safe custody for reuse in the work complete all as directed.
Materials and labour for concealed point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, drawn through and including PVC conduit 20 mm dia (medium grade) complete with all fittings and accessories, fixed to walls/ceiling, including factory made sunk type mild steel terminal boxes 1.25 mm thick (wall thickness) conforming to IS-5133 (Part-I) with 3mm thick hylem sheet top cover for mounting switches/ sockets/regulator etc., including 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One light point/ One fan point/bell point controlled by one switch including cutting chases for concealed conduit, pinning in, making good to facing and disturbed surfaces using cement mortar 1:3 complete all as specified and directed.
Description as per item No 46 here-in before but for one light point controlled by Two 2 Way switches complete all as specified and as directed.
Description as per item No 46 here-in before but for one 5/6 Amps 3 Pin Switch socket outlet on independent board complete all as specified and as directed.
Description as per item No 46 here-in before but for one 5/6 Amps 3 Pin Switch socket outlet on same board complete all as specified and as directed.
Description as per item No 46 here-in before but for one 3 pin 15 Amps switch socket out let independent and using PVC insulated, unsheathed FRLS stranded copper conductor cable of size 4 Sqmm and 4 sqmm for earth continuity conductor complete all as specified and as directed.
Materials and labour for point wiring with 1.50 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping not less than 20 mm width and 1.2 mm thick complete with all fittings and accessories, fixed to walls/ceiling, including pressed steel sunken boxes with 3mm thick bakelite sheet cover for mounting switches/ sockets/regulator etc including 1.50 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One call bell point controlled by one switch complete all as specified and directed.
Materials and labour for point wiring with 4 sq.mm. FRLS PVC insulated and unsheathed multistranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping not less than 20 mm width and 1.2 mm thick complete with all fittings and accessories, fixed to walls/ceiling, including pressed steel sunken boxes with 3mm thick bakelite sheet cover for mounting switches/ sockets/regulator etc including 4 sq.mm FRLS PVC insulated, unsheathed multistranded copper conductor cable 1100 Volts grade, single core, green in colour for earth continuity conductor connected to common earth dolly for One Geyser point controlled by one switch complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
Fixing only Modular switch 1 way 6A, 1 module complete all as specified and directed. (Serviceable Switches obtained vide item No 45 shall be used)
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
Fixing only Modular switch 1 way 16A, 1 module complete all as specified and directed. (Serviceable Switches obtained vide item No 45 shall be used)
S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
Fixing only Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. (Serviceable Socket obtained vide item No 45 shall be used)
S&F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Fixing only Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. (Serviceable Socket obtained vide item No 45 shall be used)
S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed.
Fixing only Fan step regulator complete all as specified and directed. (Serviceable regulator obtained vide item No 45 shall be used)
S&F Modular Bell push 6A 1 module complete all as specified and directed.
Fixing only Modular Bell push 6A 1 module complete all as specified and directed. (Serviceable Bell obtained vide item No 45 shall be used)
S&F Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
Fixing only Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed. (Serviceable Buzzer Ding Dong obtained vide item No 45 shall be used)
S&F modular white cover plate with frame , 2 module, complete all as specified and directed.
S&F modular white cover plate with frame , 3 module, complete all as specified and directed.
S&F modular white cover plate with frame , 6 module, complete all as specified and directed.
S&F modular white cover plate with frame , 8 module, complete all as specified and directed.
Fixing only modular white cover plate with frame , 2 module, complete all as specified and directed. (Serviceable cover plate obtained vide item No 45 shall be used)
Fixing only modular white cover plate with frame , 3 module, complete all as specified and directed. (Serviceable cover plate obtained vide item No 45 shall be used)
Fixing only modular white cover plate with frame , 6 module, complete all as specified and directed. (Serviceable cover plate obtained vide item No 45 shall be used)
Fixing only modular white cover plate with frame , 8 module, complete all as specified and directed. (Serviceable cover plate obtained vide item No 45 shall be used)
S&F Bell push, flush type, 5 amp single pole one way complete all as directed
S&F Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed.
Fixing only Ceiling rose complete all as specified and directed. (Serviceable ceiling rose obtained vide item No 45 shall be used)
S&F metal clad plug and socket with MCB and steel enclosure with 240V, 20 Amps MCB SP 10KA complete with one single pole MCB
S&F exhaust fan made of metal body complete with louvers shutter, voltage 230V, 50Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed.
S&F indoor luminare batten for wall/ceiling mounted box type energy efficient saving LED BATTEN LIGHT 18W with all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Description as per item No 80 here-in before but fixing only complete all as specified and as directed. (Serviceable fittings obtained vide item No 45 shall be used)
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver, holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
Description as per item No 82 here-in before but fixing only complete all as specified and as directed. (Serviceable fittings obtained vide item No 45 shall be used)
Supply and fixing of decorative wall light fixture made up of Polycarbonate suitable for 9W LED lamp B22 base base cable including connecting up with three core flexible copper conductor cable of suitable size complete
Supply and fixing LED street light 25 Watt made up of pressure dia cast aluminium housing with high efficient LED as lighting source and PC cover having TOP opening separate driver compartment with IP66 protection including clamp and including 1.5 m long 40mm dia GI Pipe (light grade) bracket and connecting up with required cable of suitable size complete
S&F electric water heater, storage type ABS body with Glass line coated inner tank and high wattage heating element of capicity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, Connction piece etc.complete all as specified and directed
S&F MCB DB , TPN 8 way, double door vertical with 200 Amp rated bus bar complete with fixing accessories all as specified and directed.
S&F MCCB 4 Pole, 415 Volts, 63Amps, breaking capacity 16 KA complete all as directed.
Supply, laying, jointing and testing of XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured heavy duty aluminium conductor 1100 volt grade of cross sectional area 25 sqmm 4 core complete all as specified & directed. Note: Excavation, earth work, sand cushioning and covers shall be measured and paid separately.
Sub main wiring with 2 runs (Phase & Neutral) of single core 6 Sqmm (Nominal area) stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through in and including concealed PVC conduit of required size (ISI Marked) including 1 x 6 Sqmm (Nominal area) FRLS PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earth continuity conductor shall be measured as one run length.
Sub main wiring with 4 runs (Phase & Neutral) of single core 10.0 Sqmm (Nominal area) stranded FRLS PVC insulated unsheathed copper conductor cable 1100 volts grade drawn through in and including concealed PVC conduit of required size (ISI Marked) including 1 x 10.0 Sqmm (Nominal area) FRLS PVC insulated unsheathed stranded copper conductor green in colour for earth continuity conductor and connected to common earth dolly complete all as specified and as directed. Note: Two runs of 10.0 Sqmm cable and one run of 10.0 Sqmm earth continuity conductor for concealed shall be measured as one run length.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring, etc. cutting not exc 10cm girth, complete all as specified and directed.
MCB DB , SPN 4 way, double door with 200 Amp rated bus bar, horizontal type IP-43 including earth and neutral link ,complete with fixing accessories all as specified and directed.
S&F MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-40 Amps complete all as directed.
S&F MCB DP 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 Amps complete all as directed.
S&F MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps complete all as directed.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level sourrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filled in alternate layers etc and connected to and including 32 x 6 mm GI strip upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 40 mm bore GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded aggregate) including excavation and earthwork, disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and hanging only ceiling fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed. Note: Ceiling Fan shall be issued under Sch"B".
Supply and fixing anti Sucidal Rod of 20 Kg limit 250mm long white in colour for ceiling fan complete all as specified and as directed.
Supply and fixing Modular metal flush box 2 module complete all as specified and as directed.
Fixing only Modular metal flush box 2 module complete all as specified and as directed. (Serviceable metal box obtained vide item No 45 shall be used)
Supply and fixing Modular metal flush box 3 module complete all as specified and as directed.
Fixing only Modular metal flush box 3 module complete all as specified and as directed. (Serviceable metal box obtained vide item No 45 shall be used)
Supply and fixing Modular metal flush box 6 module complete all as specified and as directed.
Fixing only Modular metal flush box 6 module complete all as specified and as directed. (Serviceable metal box obtained vide item No 45 shall be used)
Supply and fixing Modular metal flush box 8 module complete all as specified and as directed.
Fixing only Modular metal flush box 8 module complete all as specified and as directed. (Serviceable metal box obtained vide item No 45 shall be used)
Excavation in trenches in soft/loose soil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for laying of pipe, cable etc and getting out complete all as specified and directed by Engineer-in-charge.
Returning, filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak size 250mm x 150mm x 40mm complete all as specified and directed.
Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed. (Note:- Only punned thickness of 18cm shall be measured and paid)
N.V.ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .