| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹115.6 CrAccepted-AOC | ₹115.6 Cr Quoted ₹115.8 Cr | 1 | Accepted-AOC Being L1 |
| 2 | 2₹122.2 CrRejected-Finance | ₹122.2 Cr | 2 | Rejected-Finance not being L1 |
| 3 | 3₹146.9 CrRejected-Finance | ₹146.9 Cr | 3 | Rejected-Finance not being L1 |
| 4 | 4₹152.8 CrRejected-Finance | ₹152.8 Cr | 4 | Rejected-Finance not being L1 |
| 5 | 5₹170.7 CrRejected-Finance PREMISES NO 5 30 5 N C SENGUPTA SARANI GROUND FLOOR MALL ROAD KOLKATA WEST BENGAL INDIA 700 080 | KOLKATA | KOLKATA | WEST BENGAL | 700080 | ₹170.7 Cr | 5 | Rejected-Finance not being L1 |
Tender Value
Refer Docs
EMD Value
₹25.8 L
Closing Date
7 Aug 2021, 6:00 pmClosed
CHIEF ENGINEER (NAVY)
CE (NAVY) ZONE, STATION ROAD, VISAKHAPATNAM-530004
PROVISION OF MARRIED ACCOMMODATION FOR SAILORS AT VISAKHAPATNAM
2021_MES_437633_1
CA NO CE(NAVY)/VIZ/TOKEN/01/2019-20
Open Tender
Civil Works
1460 days
VISAKHAPATNAM
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE(P) NO 02 NAVY VISAKHAPATNAM
₹25.8 L
Yes
31 Aug 2021
22 Apr 2021
9 Aug 2021
22 Apr 2021
7 Aug 2021
1 Aug 2021
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Construction of Married accn for MCPO/CPO sailors in RCC Framed Structure (G+12 storeyed) on pile foundation including, two RCC terrace tanks, SS railing, Car and scooter garage in stilt floor, Lift well, tie beams, pile caps with PCC and moorum filling etc.,but excluding pile foundation complete all as specified and as shown on drawings and as directed.
Construction of Married accn for PO/LEADINGS & BELOW sailors in RCC Framed Structure (G+12 storeyed) on pile foundation including, RCC terrace tanks, SS railing, Scooter parking in stilt floor, Lift well, tie beams, pile caps with PCC and moorum filling etc.,but excluding pile foundation complete all as specified and as shown on drawings and as directed.
Construction of Pump house in RCC framed structure with permanent specifications complete all as specified and shown on drawings and as directed.
Note for item no.1 , 2 and 3: (i) Cost of plinth/floor beams, tie beams, pile caps, with sub base/lean concrete and moorum filling shall be deemed to be included in the Lump sum quoted for item above. (ii)Earth work, excavation, returning filling , disposal of surplus soil to a distance as specified, moorum filling under floors with reference to MGL as shown in the drawings for building portion i.e. up to the external face of plinth protection is deemed to be included in the scope of lumpsum quoted against these items. (iii) Surplus soil obtained from excavation shall be removed at a distance not exceeding 500m as directed by GE. (v) The scope of pile foundation is not included in the lumpsum. The same shall be measured and paid separately under Sch 'A' Part III (Pile foundation). However, the foundation upto and including pile caps is included in the scope of lumpsum. (vi) The dowel bars of pile reinforcement projected into pile caps (development length) as shown in drawings shall be measured and paid in Sch 'A' Part III (Pile foundation). vii) Soil between NGL and 0.75m below pile cap shall be completely replaced with Moorum filling as specified in the drawing and is included in the scope of lumpsum. viii) The height between MGL and NGL is approx 20 mm. The moorum filling between MGL and NGL will be measured and paid separately under Sch 'A' Part II. However, the structural members between MGL and NGL will be part of lumpsum quoted for item above. Depth of Pile cap to be measured from NGL and FFL to be measured from MGL.
Construction of RCC Under Ground sump 4.0 lakhs liters capacity for water supply and fire-fighting as per drawing No TD 395(S) complete all as specified and as shown on drawings and as directed.
Construction of RCC Under Ground Sewage collection sump of 4.0 lakh liters capacity as per drawing no TD 396(S) complete all as specified and as shown on drawings and as directed. NOTES for item No. 04 and 05: (i) Earth work, excavation, returning filling , disposal of surplus soil to a distance of 500m to 1 KM as specified and directed by Engg-in-charge, filling under floors with reference to MGL as shown in the drawings for building portion i.e. up to 3m beyond the external face of plith protection is deemed to be included in the scope of lumpsum quoted against these items.
NOTE : Schedule "A" Part II to Part XVI are prepriced by MES.
Lumpsum price worked out by the contractor for " Site Clearance / Area Development / Earthwork/ Excavation", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for " Pile Foundation", as listed in Schedule "A" Part – III.
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "Compound wall", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII
BLANK
Lumpsum price worked out by the contractor for "Rain Water Harvesting", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM, FIRE ALARAM and DETECTION", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "DISMANTLING/ DEMOLITION", as listed in Schedule "A" Part – XVI
Schedule "A" Part - XVII [Miscellaneous Items]
Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 400 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition at Sea area and conforming to condition under IS 4722, BS 5514/2613/5000 and comprising of the following accessories consisting as per details mentioned in ANNEXURE - A of BOQ complete all as specified and as detailed below: NOTE : (i) ANNEXURE - A has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.
PILE FOUNDATION
Boring for bored cast–in–situ piles 450mm dia in any type of soil/Soft disintegrated rock except hard rock and getting out and disposal of soil outside MoD land using Rotary drilling method by Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Boring for bored cast–in–situ piles 450mm dia in hard rock and getting out and disposal of soil outside MoD land using Hydraulic Rotary Rig by DMC method complete all as specified and directed.
Carrying out Initial Load Test on 450 mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Lateral Load Test on 450 mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Pullout Test on 450 mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Routine Load Test on 450 mm dia bored cast–in–situ piles as per IS – 2911 [Part – IV] complete all as specified and as directed.
Carrying out Low Strain Integrity Test on cast–in–situ piles of 450 mm dia including analysing the results as per IS – 14893 & ASTM D 5882 complete all as specified and as directed.
Chipping out Pile up to cut off level including disposal up to a distance of 50m complete all as specified and as directed.
AVIATION LIGHT
Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts, nuts etc. Complete all as specified and directed.
Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements complete all as specified and directed.
Time switches 250V single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
FIRE FIGHTING SYSTEM, FIRE ALARM AND DETECTION
Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing, bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 Phase. 50 Hz 70m Head, 2280 LPM discharge at 3.5 kg/sqcm all as specified and as directed
Fire pump diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469 1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V , 3 phase, 50 Hz AC supply 70 m Head. 2280 LPM discharge at 3.5 kg/sqcm.along with 180 AH batteries (02 Nos of 12 Volts 180 AH Batteries) all as specified and as directed.
MS flanged pipe 150mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and as directed.
MS flanged pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and as directed.
MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and as directed.
Ductile pipe with double flanged centrifugally cast(spun) class K-9 of 150mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning (For external Ring main and upto Bldg) all as specified and as directed.
Fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290 including PVC blank cap and GI chain,CI hand wheel complete all as specified and directed.
63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 all as specified and as directed.
63 mm dia gun metal branch pipe with 12.5 mm bronze nozzle out let conforming to IS 903 all as specified and as directed.
Hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm all as specified and as directed.
Flanged end lift type Foot valve 150 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
Flanged end lift type Foot valve 80 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
Ductile iron fittings such as Bends, Tapers, Tee pieces(single & double branch any type and angle/radious and straight connecting pieces complete all as specified and as directed.
Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS: 15683 of capacity 3 Kg all as specified and directed.
Fire ExtinguisherDry Chemical, Powder (ABC) type confirming to IS:15683 of capacity 3 Kg all as specified and directed.
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade all as specified and as directed.
LT Panel board made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories as specified hereunder: Incoming: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no-volt thermal based release. Outgoing: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (1 No for Jockey Pump and 01 No for Spare]. [c] LT 440V 3Phase 4 wire 50cycles 25KA 32A MCCB-1Nos [d]Star delta starter of capacity upto 80 HP for electric driven fire pump - 01 Nos. [e] Starter of suitable capacity for electric driven Jockey Pump - 01 Nos [f] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [g] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.
GEYSER
Supply, installation, testing and commissioning of geyser electric driven (single phase) of capacity 15 liters of 5 star rated with flexible hot/cold flexible water pipes with all necessary acessories and connections complete all as specified and directed.
COMPOUND WALL
Chainlink fencing of mesh 50X50mm made out of 10 gauge dia mild steel wire over PVC coating to make overall dia as 6 gauge including GI binding wire and fixing of MS round bar 10mm dia as line wire for holding chainlink mesh complete all as specified and directed.
EXTERNAL WATER SUPPLY
Supply, installation, testing and commissioning of Star delta type starter panel with steel enclosure for submersible pump, 415 V,15 HP capacity all as specified and as directed.
Electric copper cable of size 6.0 sqmm ,3.0 core 415 V, complete all as specified and as directed.
Cutting the existing steel tubing for alterations or additions necessarily done in position without taking down and inserting Tee of 100x100x100 mm with collars and required specials for taping including necessary earth work excavation complete all as specified
Electric driven centrifugal pump set of head 90 Mtr ,1950 LPM suitable for 415 V, 3 phase for 440 V, Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings of suitable capacity but not less than15 HP complete with suitable foundation and electric connection all as specified and as directed.
Construction of Valve Chamber of size 750 X 750 X 750 mm , with 50mm thick PCC 1:5:10, Type E2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 100 mm thick PCC, 1:3:6, Type C1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick internally and externally up to 50mm below GL including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Ductile Iron pipe 200 mm bore,centrifugally cast with socket and spigot ends confirming to IS-8329 in standard lengths suitable for push on rubber gasket tyton joints compleate all as specified and directed. Note: DI specials will be measured and paid separately.
Ductile Iron pipe 150 mm bore,centrifugally cast with socket and spigot ends confirming to IS-8329 in standard lengths suitable for push on rubber gasket tyton joints compleate all as specified and directed. Note: DI specials will be measured and paid separately.
Ductile Iron pipe 100 mm bore,centrifugally cast with socket and spigot ends confirming to IS-8329 in standard lengths suitable for push on rubber gasket tyton joints compleate all as specified and directed. Note: DI specials will be measured and paid separately.
LT Panel board made out of CRCA sheet 2.0 mm thick indoor wall mounted type totally enclosed with front opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories as specified hereunder: Incoming: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, no-volt thermal based release. Outgoing: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 32 Amp rated complete with overload protection, no-volt thermal based release - 02 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release - 03 Nos. [c]Star delta starter of capacity upto 40 HP for electric driven pump - 02 Nos. [d] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [e] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.
SEWAGE DISPOSAL
Supply, installation, testing and commissioning of Non clogging type Submersible pump, electric driven 415 V,not less than 15 HP capacity ,40 mtr head and steel wire of suitable size complete all as specified and as directed.
LT Panel board made out of CRCA sheet 2.0 mm thick indoor wall mounted type totally enclosed with front opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V , 300 A capacity complete with powder coating, necessary internal electric connection as required and as specified and directed. The Bus Bar rating shall be 300 Amp along with all accessories inclusive as specified here under: Incoming: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no-volt thermal based release. Outgoing: [a] LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 40 Amp rated complete with overload protection, no-volt thermal based release - 03 Nos. (01 No Spare). [b] LT 440 volts 3 phase, 4 wire 50 cycles, 16 kA, Adjustable type MCCB of 32 Amp rated complete with overload protection, no-volt thermal based release - 01 Nos. [c]Star delta starter automatic suitable for submersible electric driven pump - 02 Nos. [e] LED Indicating Lamps for ech phase with colour code Red Yellow Blue for R, Y and B Phases [f] Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power along with connected CTs.
EXTERNAL ELECTRIFICATION
Supply, installation, testing and commissioning of LT Panel Board CPRI approved , free standing floor mounted, dust and vermin proof made out of CRCA sheet 2 mm thick indoor Pedestal type totally enclosed with front and rear opening,compartmentalised, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switch gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned Aluminium bus bar with insulating sleeves colour codes suitable for three phase and four wire LT AC, 50 Hz 415 V 3000 A capacity complete with powder coating, necessary internal electric connections.The panel is having two portions and each portion interconnected through mechanically operated Buscoupler with necessery locking/safety arrangements and comprising of the following accessories as per details mentioned in ANNEXURE -D of BOQ complete all as specified and as directed. NOTE : (i) ANNEXURE -D has been uploaded separately alongwith tender documents and is part of BOQ for all purposes.
Supply, install, test and commissioning of LT Panel Board CPRI approved , free standing floor mounted, dust and vermin proof made out of CRCA sheet 2 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 600 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Block Panel) Incoming: a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 250 A capactiy 36kA(ICS=ICU 100%) microprocessor release with inbuilt relay with adjustable type thermal and magnetic setting release - 01 No. b) Intelligent Panel meter to measure voltage, current, frequency, power factor,etc with all connected CTs c) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply, install, test and commissioning of LT Panel board (Standby panel) made out of CRCA sheet 2 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 1000 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: Incoming: (a) MCCB 3 Phase 415 V, 50Hz ,microprocessor release 4 pole 550 A capactiy 50kA ,(ICS=ICU 100%)with adjustable type overload protection, short circuit protection,with inbuilt display for 20 fault history current parameters and necessary CTs, meters and cable boxes - 01 No. Outgoing: a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25kA (ICS=ICU 100%)with adjustable type thermal and magnetic setting release - 12 Nos (9 nos for each block lift panel,1 nos for sewage pump,2 nos spares) c) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25kA with adjustable type thermal and magnetic setting release - 02 No. d) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs e) LED Indicating Lamps for each phase with colour coded Red Yellow Blue for R, Y and B Phases
Sheet metal encloser ,provision of fixing incoming and out going cables with bus bar for cable connection tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. ( For lift machine room) Incoming:- (a) MCCB 63 Amps,25 KA 4P - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two lift panel + 01 Spare) (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases (c)multifunction meter for indicating voltage,current,frequency
Integral LED street light Luminaire 40 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete and testing all as specified and directed.
Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, Cable Glands of IP 65 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps,SP, 10 kA, C Curve Overload and Short Circuit protection,heavy duty PVC connector 4way 32A capacity -1No terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified and as directed.
Compact type Wall/pole mounted Street light Timer Panel with powder coated mild steel enclousure of 12 KW,415 Volt to be fixed on pole/wall with provision of bus bar ,Power Contactor 65 Amp,MCB 32 Amp TPN ,Digital Timer Switch complete fixed with mild steel clamp,nut & bolt and including all as specified and as directed.
Supply and Installation Supply, installation, testing and commisioning of distribution Transformer step down 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% cotinuous rating of 750 KVA outdoor type confirming to (IS 1180, level-II) with and including the following: (a) Lifting lugs/ hooks for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level guage. (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335. (j) Type of connection : Delta/Star. (k) Type of cooling : ONAN. (l) Vector Group : DYN 11. (m) Type of connecting arrangement : Cable termination boxes on both HT and LT side. (n) Temperature rise over an ambient of 50 degree centigrage maximum. (o) All necessary arrangements with devices for measuring the temperature of core, winiding and oil. (p) In addition to the above all standard fittings shall be provided as per IS norms.
Supply and Installation Supply, installation, testing and commisioning of Bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 550 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8 mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg comprising of followings:
Supply and fixing of Straight length with plugin oultet of Busbar trunking system as specified and directed.
Supply and fixing of Flange end of Busbar trunking system as specified and directed.
Supply and fixing of Horizontal elbow of Busbar trunking system as specified and directed.
Supply and fixing of Vertical elbow of Busbar trunking system as specified and directed.
Supply and fixing of End cap of Busbar trunking system as specified and directed.
Supply and fixing of Brackets of Busbar trunking system as specified and directed.
Supply and fixing of Springs support of Busbar trunking system as specified and directed.
Supply and fixing of Fire barrier of Busbar trunking system as specified and directed.
Supply and fixing of External GI strip 32 x 6 mm of Busbar trunking system as specified and directed.
Supply and fixing of End feed Unit with MCCB of Busbar trunking system as specified and directed.
Supply and fixing of 250 A 25 KA 4P MCCB of Busbar trunking system as specified and directed.
Supply and fixing of Terminal links (as required) of Busbar trunking system as specified and directed.
Supply and fixing of 63 A thermoplastic plug in tapoff box of Busbar trunking system as specified and directed.
Supply and fixing of MCB 63A 4P 10 KA - 13 Nos of Busbar trunking system as specified and directed.
Supply and fixing of 63A 4P lightning trunking - 13 Nos of Busbar trunking system as specified and directed.
Supply and fixing of Feed unit with cover of Busbar trunking system as specified and directed.
Supply and fixing of Flexible joint of Busbar trunking system as specified and directed.
Supply and fixing of Bracket support with steel cable of Busbar trunking system as specified and directed.
Earthing complete with Galvanised iron earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6 mm GI earth strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m in length from earth plate, Earth Plate Electrode surrounded by 150 mm thick packed layers of Charcoal and Rock Salt filled in alternate layers, connected to the plate by means of brass Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Rock Salt, PCC chamber [1:3:6, Type C1] with RCC cover of 1:2:4 type B1 , MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with copper plate electrode 60 cm X 60 cm X 3 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 300 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 240 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 95 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 35 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 10 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and screened insulated, FRLS armoured and PVC bedded underground HT cable, ISI marked with aluminium stranded conductor 11000 Volt grade (heavy duty) of size 3 Core, 300 Sq.mm cross section conforming to IS-7098 (Part-II) laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and directed.
Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Alluminum conductor cable of size 300 sqmm, Indoor type all as specified and as directed.
Straight cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Alluminum conductor cable of size 300 sqmm all as specified and as directed.
INTERNAL ELECTRIFICATION
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one point complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one bell point controlled by one bell push complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one fan point controlled by one point complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 15 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by two number two way switch complete all as specified and as directed.
LED adore lamp for AC 240Volt supply, B22 type,CDS five star, 9 watts of five star rated complete all as specified and as directed.
Energy efficient LED tube light fitting suitable for mirror light with tube 5 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed.
LED Security light fitting with tube 30W new generation energy saving &environmental friendly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. compelte all as specified and as directred.
BLDC type Ceiling fans AC single phase 230V of size 1200mm sweep, copper wound with complete set of fixtures such as canopy, down rod etc , 5 star rating, metallic body complete with and inclusive of making necessary electric connections from ceiling rose to fan tthrough twin core flexible wire and writing MES No. 2CM height with synthetic enamel block paint complete with 2 years warranty all as specified and directed.
Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc. complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire and writing MES No. 2CM height with synthetic enamel block paint complete with 2 years warranty all as spcified and as directed.
Exhaust fan 300 mm sweep, (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire and writing MES No. 2CM height with synthetic enamel block paint complete with 2 years warranty all as specified and as directed.
Exhaust fan 380 mm sweep or nearest size, 900 RPM , (Heavy duty), complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire and writing MES No. 2CM height with synthetic enamel block paint complete with 2 years warranty all as specified and as directed.
MCB DB concealed in wall Vertical double door type, TPN 4 way 415V, 50Hz, IP 43 protection with 200A rated bus bar, including provision for fixing RCBO FP 63 amp as incommer and SP MCBs as outgoings complete, fill empty way with blanking plates complete all as specefied and directed.
MCB DB concealed in wall double door type, Single pole and neutral 08 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
MCB DB concealed in wall double door type, Single pole and neutral 04 way sheet steel phospetised powder painted with 200 amps rated bus bar 240 Volts nautral link, IP : 43 protection, complete all as specified and directed.
MCB SP 6 to 32 Amps 240 Volts, 10KA, C curve complete all as specified and directed.
MCB SPN 6 to 32 Amps 240 Volts, 10KA, C curve complete all as specified and directed.
RCBO FP 63 Amps, 30mA, 415 Volts complete all as specified and directed.
Single phase electronic Energy meter tamper proof with LCD display, 240 volt , 50Hz AC supply, 5 to 30 amps capacity complete all as specified and as directed.
Prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 4 Nos single phase energy meter, front portion of the meter box to be provided with four opening to take the reading of energy meter and the four slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete all as directed and as specified. Note: Energy meter shall be measured and paid seperately.
TV socket incuding GI box, inner and cover plates complete all as specefied and directed.
Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including one run of 16 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. (Bus bar trunk/MCCB to VTPN DB of each floor). Note: 4 runs of 16 Sq.mm, 1 runs of 16 Sq.mm & one run of 32mm dia PVC Conduit will be measured as one unit
Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 6 Sq.mm, 1 runs of 6 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 2.5 Sq.mm, 1 runs of 2.5 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
INTERNAL WATER SUPPLY
CP mixer for mixing hot and cold water screwed down for pipe of chromium plated, fancy type with two out going (one for bib tap and another for shower) complete all as specified and as directed.
Angle stop valve, chromium plated, fancy type, high pressure screwed and fixed suitable for 20mm PP-R pipe complete all as specified and as directed.
ARBORICULTURE
Planting carpet Grass by piece turfing including preparation of ground upto 30cm deep and filling soft soil, cow dung and watering etc complete all as specified and directed. Note: Loose soil and cow dung shall be measured and paid separately.
Planting Paspulam Grass by piece turfing including preparation of ground upto 30cm deep and filling soft soil, cow dung and watering etc complete all as specified and directed. Note: Loose soil and cow dung shall be measured and paid separately.
Supply only approved loose soil of best quality for plantation.
Supply only approved manure (Cow dung) of best quality for plantation.
Supply only approved vermi compost of best quality.
Plantation of foxtail palm (height of plant not less than 2.0m above ground level) including preparation of ground upto 30cm deep and filling of good earth, cow dung, vermi compost and watering etc complete all as specified and directed.
Plantation of Royal Palm (height of plant not less than 1.50m above ground level) including preparation of ground upto 30cm deep and filling of good earth, cow dung, vermi compost and watering etc complete all as specified and directed.
GI tubing 25mm bore medium grade confirming to IS: 1239 with all fittings laid in trenches in arboriculture complete all as specified and directed.
GI tubing 15mm bore medium grade confirming to IS: 1239 with all fittings laid in trenches in arboriculture complete all as specified and directed.
25mm dia Gun metal gate valve with iron wheel head screwed both ends for in iron pipe in arboriculture complete all as specified and directed.
15mm dia Gun metal gate valve with iron wheel head screwed both ends for in iron pipe in arboriculture complete all as specified and directed.
Supply, fixing, testing and commissioning sprinklers in arboriculture complete all as specified and directed.
ROAD/PATH/HARD STANDING/CULVERT
Granular sub Base (GSB) with grading V of 150mm thick compacted thickness (laid in two layers of 75mm each, Compacted seperately) confirming to grading as specified, spread, rolled and consolidated to required gradient asnd camber complete using necessary mechanical paver/Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base fillimg shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/checked for suitability to use. (e) The lead/Royality involved is to be ascertained by the contractor before quoting his tender and no extra payment/Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor inlieu of Power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in perticular specification.
Wet mix Mecadam of 250mm thick (Compacted thickness) laid in three layers compacted separately with coarse aggeregate of specified grade spread, rolled and consolidated to required gradient and camber complete using mechanical paver/Greader and Pandom vibrator of capacity of minimum 8-10 tons at OMC to achieve atleast 98% MDD determained using modified proctor density determination method as per IS code on prepared GSB surface complete all as specified and directed. Note: 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled seperately.
Painting lines, dashes, arrows, letters etc. on road surface with hot applaid retro reflective thermoplastic paint confirming to MORTH (Clause 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 degreeC, including cleaning and drying the road surfaces to ensure dust, oil, grease and moisture free surface before applying paint complete all as specified and as directed.
Two way (dual direction) reflective road studs (Solar cat Eyes) of aluminium body of size 90X110X17mm, impact resistance ABS body with amber red or white reflective panels and fixing the same on road surface by applying minimum 100grms of epoxy mixture and placing the cat eye without applying excessive pressure and additionally fixed with 12mm dia, 120mm long zinc plated steel nail at the center of the cat eye complete all as specified and as directed.
Road furniture as specified and directed of shape rectangular as per standard size with specified sign including amending 50mm GI pipe into ground with PCC 1:3:6 in posts complete all as specified and as directed.
Road furniture as specified and directed of shape of the sign board is circular of standard size with specified sign including amending 50mm GI pipe into ground with PCC 1:3:6 in posts complete all as specified and as directed.
Cutting of Bituminous road width of cutting n.exc.3.0m and n.exc 50cm in deep at ground level for excavation of trenches from RCC culvert complete all as specified and as directed.
SITE CLEARANCE/AREA DEVELOPMENT/EARTH WORK/EXCAVATION
Felling of tree exc. 300cm and n.exc.400cm in girth including cutting of trunk, and branches and stacking of servicable material and disposal of unservicable material to a distance n.exc. 50m and clearing site complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 30 cm and n. exc. 100 cm complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 100 cm and n. exc. 150 cm complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 150 cm and n. exc. 200 cm complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 200 cm and n. exc. 250 cm complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 250 cm and n. exc. 300 cm complete all as specified and as directed.
Grubbing up tree trunk including cutting of trunk portion protruding over ground, digging out roots, filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material to a distance n. exc. 300m and clearing site and girth of tree exc. 300 cm and n. exc. 400 cm complete all as specified and as directed.
MAINTENANCE OF ARBORICULTURE [Schedule "A" Part – XVIII]:
Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for period of maintenance period of ONE YEAR from the completion date of phase II complete all as specified and directed.
SCHEDULE 'A' PART-XIX FIRST YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 21 AND 22 AFTER COMPLETION OF WORK
Comprehensive maintenance of Electrically Operated 08 No of 08 passenger lifts(544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 21 of Sch "A" Phase-I (Eight Lifts) including ARD and all connected components of lift during 1st year after completion of work all as specified and directed
Comprehensive maintenance of Electrically Operated 08 no of 13 passenger lifts(884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 22 of Sch "A" Phase-I (Eight Lift) including ARD and all connected components of lift during 1st year after completion of work all as specified and directed
SCHEDULE 'A' PART-XX SECOND YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 21 AND 22 AFTER COMPLETION OF FIRST YEAR COMPREHENSIVE MAINTENANCE.
All as per description of item No. 159 but second year after completion of work and After completion of first year Comprehensive Maintenance.
All as per description of item No. 160 but second year after completion of work and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXI THIRD YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 21 AND 22 AFTER COMPLETION OF SECOND YEAR COMPREHENSIVE MAINTENANCE.
All as per description of item No. 159 but third year after completion of waork and after second year Comprehensive Maintenance.
All as per description of item No. 160 but third year after completion of work and after second year Comprehensive Maintenance.
Note for SL No: 159 to 164 :- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in 06 months complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.
DES RAJ AND SONS BUILDERS PVT LTD
Som Projects Pvt Ltd
SHRE GURMUKHDAS CONTRACTOR PVT. LTD.
PUSHKARRAJ CONSTRUCTION PRIVATE LIMITED
Varindera Constructions Limited
NCC LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf