Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC A S GIRLS SCHOOL ROAD HIRAPUR DHANBAD DHANBAD 826001 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 826001 | L1 | Accepted-AOC successful L1 bidder | |
| 2 | Not Admitted-Finance NEAR RANGUNI RAILWAY GATE BHULI DHANBAD DHANBAD 828105 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828105 | - | Not Admitted-Finance Not qualified for AOC | |
| 3 | Not Admitted-Finance PARNABALIYA KALI MANDIR ROAD NEAR CIRCUIT HOUSE BEKAR BANDH DHANBAD JHARKHAND 826001 | DHANBAD | DHANBAD | JHARKHAND | 826001 | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹12.4 L
EMD Value
₹15,510
Closing Date
26 Jan 2026, 5:00 pmClosed
Dy Mgr EnM
Dy Mgr EnM CHD
Upgradation and Improvement of electrical wiring and circuit arrangement for an online UPS at CCM complex, Central Hospital Dhanbad.
2026_BCCL_351283_1
BCCL/CHD/EnM/eNIT/2025-26/A/20 Date-15.01.2025
Open Tender
Electrical and Maintenance Works
Percentage
25 days
Central Hospital Dhanbad
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,510
18 Mar 2026
16 Jan 2026
28 Jan 2026
16 Jan 2026
26 Jan 2026
16 Jan 2026
16 Jan 2026 - 23 Jan 2026
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
4 X 10 sq. mm + 2 X 10 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
Group A
Group B
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Bell Push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
4 way (4 + 12), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Double pole
Supply & fixing of 63 Amps 4 Pole C curve MCB in the exisisting DB complete with connections, testing and commissioning etc. as required. (Make L&T, Havells & Legrand.)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Supply and fitting of 20/22 watt, 4feet long LED tube light fitting, Make - Havells/ Penasonic/ Bajaj/ Orient ( Warranty 1 yr.)
Supply and Fitting 50 Watt LED Flood Light, Make - Havells/ Panasonic/ Bajaj/ Orient (Guaranty/Warranty minimum-1 Years)
Supply & fitting of 4 pole, 415 V, 250 Amp., 36 KA MCCB in the existing panel complete with connections, testing and commissioning etc. as required. (Make-L&T/Havells/Legrand)
Supply & Fixing of Spreader terminal suitable for 4 Pole, 250 Amp MCCB
Supply & fitting of 4 pole, 415 V, 125 Amp., 36 KA MCCB in the existing panel complete with connections, testing and commissioning etc. as required. (Make-L&T/Havells/Legrand)
Supply & Fixing of Spreader terminal suitable for 4 Pole, 125 Amp MCCB
Supply & Fixing of 3 phase, LED Ammeter in the existing electric panel. ( Make:- L&T, Havells & Legrand)
Supply & Fixing of 3 phase, LED Voltmeter in the existing electric panel. ( Make:- L&T, Havells & Legrand)
Fabrication & fitting of electric Panel with powder coated MS sheet of 6 x 4 feet
Supply & fixing of Copper flat for Bushbar 32 mm x 6 mm in the exisisting panel with making hole, connection testing etc as required.
Supply & fixing of CT 200/5 Amps 2.5 VA class-1 in the exisisting panel
Supply and Fixing of Indicator Lamp in the panel.
Supply & fixing of 200 AMP, 4 pole manual change over in metal steel encloser.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2 + 4 way, Double door
Supply & laying of 70 Sq.mm X 4 core, 1.1KV garde Aluminium single armored cable
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.44 MB
BOQ_364035.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .