Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical ADMINISTRATIVE REASON |
| 2 | Rejected-Technical S K SARANI BIRATI KOLKATA 700051 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700051 | Rejected-Technical ADMINISTRATIVE REASON |
| 3 | Rejected-Technical | Rejected-Technical ADMINISTRATIVE REASON |
Tender Value
₹9.6 L
EMD Value
₹19,151
Closing Date
17 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHAIRMAN
163, M.B.ROAD, BIRATI, KOLKATA - 700051 ,WEST BENGAL
Supply and fixing of LED flood light under newly constructed shed and replacement defected existing sodium vapour light by 120 watt LED street light at Itkhola water reservoir in ward no 24 under North Dum Dum Municipality.
2025_MAD_954910_1
WBMAD/NDDM/ELEC/NIeT261/25-26
Open Tender
Electrical Work/ Equipment
Percentage
30 days
UNDER NORTH DUM DUM MUNICIPALITY
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹19,151
7 Jan 2026
20 Nov 2025
19 Dec 2025
20 Nov 2025
17 Dec 2025
20 Nov 2025
Supplying and delivery of 120 W LED street light, new generation energy saving and environmental friendly lonhg life versatile pressure die cast aluminium housing IP66 and impact resistant of IK07, road way luminarie with high power LED. CHIP. Make - CREE / NICHIA / LUMILEDS / OSRAM / SEOUR, confirming to Technical specification and latest accreditation. LM - 79 and LM -80 report to be provided from any NABL accredited Lab. system efficacy > 115 Lumens / watt LED should be warrantee for 5 years.
Supplying and delivery of 110 W LED flood light, new generation energy saving and environmental friendly lonhg life versatile pressure die cast aluminium housing IP66 and impact resistant of IK07, with high power LED. CHIP. Make - CREE / NICHIA / LUMILEDS / OSRAM / SEOUR, confirming to Technical specification and latest accreditation. LM - 79 and LM -80 report to be provided from any NABL accredited Lab. LED should be warrantee for 5 years. Make - Philips / Magik / Benlo.
Fixing only flood light, fitting with suitable tie clamps and MS plate for mounting on pole / tower or similar structure.
Fixing only flood light, fitting with suitable tie clamps and MS plate for mounting on pole / tower or similar structure.
Laying only cable upto 50 sqmm through existing RCC / Hume / GI pipe / open masonary trench for single, 2, 3, 3.5 & 4 core.
Supply high density polythene pipe complete as necessary and as per direction of EIC. Confirming to IS 4984/1985, 6 Kg. / sqcm, 40 mm dia, 3 mm thick polythene pipe.
Supply and fixing medium gauge GI pipes (ISI medium) protection with necessary fitting and jointing materials as required, 40 mm dia GI pipe.
Supply, delivery and laying 3 core 1.5 sqmm flexible wire as per IS 694 (connection for pole to light fixture), Make - Incab / Gloster / Polycab / Havells.
S & F compression type blank complete with brass gland, brass ring and rubber ring for dust and moisture proof entry of XLPE / PVC armoured cable as below, for 4 core, 16 sqmm.
Supplying & Erection of mini size feeder piller box of size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable MS Angle. The PB have double hinge door at the front & back with suitable locking arrangement. The box will painted by 2 coates of aluinium paint over 1st coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion covred by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand and drawing & direction of EIC.
Supply and fixing 415 Volt TPN Fuse with sheet steel enclosure on flat iron frame on wall with nut bolts etc. incl. S & F 3 nos. DIN type HRC fuse, 32 Amp., Havells.
Supply & fixing of 240 / 230 Volt, 50 Hz, T. P. Power contractor, (make L & T / ABB / Schneider / Simence / GE) having contact block of the following range, 18 - 30 Amp., 1NO/1NC.
Supply and delivery of electronic driver suitable for 240 / 360 / 415 V, 50 Hz (Make - L & T / ABB . Schneider / Simence / GE / Minilic) of the following time (second )range 3.0 to 30.0.
Supply and fixing Toggler switch (On - off - on).
Supply and fixing of 230 / 240 Volt, LED indicating lamp (Make - AE / KAPPA / IMP), blue / white colour.
Supply and fixing of terminal block.
S & F 240 Volt MCB of breaking capacity 10 KA and C characteristics on Din rail of existing DBs and necessary connection, Make - Havells, SP, 6- 32 Amp.
S & F 415 Volt MCB of breaking capacity 10 KA and C characteristics on Din rail of existing DBs and necessary connection, Make - Havells, FP, 32 Amp.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mtr. Long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers including S & F 15 mm dia GI pipe protection ( 1 mtr long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs. below the ground level as as below : by ISI medium GI pipe.
Supply & fixing of special head type MS loop box (3 mm thick) with connecting bar and other accessories fixed on the top of the pole as required and as per direction of EIC for 3 phase connection.
S & F 240 V MCB of breaking capacity 10 KA and C characteristics on din rail of exisiting DBs and necessary connection. (Make - Legrand).
Sub Total
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_2289189.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .