Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC SIMURALI NADIA | PURBA BARDHAMAN | WEST BENGAL | 713502 | ₹6.9 L | L1 | Accepted-AOC AOC |
| 2 | L2₹7.0 LRejected-Finance UKIL PARA KRISHNANAGAR | KRISHNANAGAR | NADIA | WEST BENGAL | 741201 | ₹7.0 L | L2 | Rejected-Finance Rejected as L2 |
| 3 | L3₹7.1 LRejected-Finance 30 2 RAJKUMAR MUKHERJEE ROAD KOL 700035 | KOLKATA | KOLKATA | WEST BENGAL | 700035 | ₹7.1 L | L3 | Rejected-Finance Rejected as L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Reject Due to mismatched Credential |
| 5 | Rejected-Technical KRISHNAGAR DIST NADIA | NADIA | WEST BENGAL | 741101 | - | - | Rejected-Technical Reject Due to mismatched Credential |
| Sl No | Description | Qty | Unit | M/S. GHOSH ENTERPRISE L3 | RAJ AND ENTERPRISE L2 | LOKNATH ENGINEERING L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismalting of existing wiring, DB, switch board, fan , light fittings by expart electrician own's tools and tackeles. | 1 | LS | 1,200 ₹1,200 | 1,190 ₹1,190 | 500 ₹500 |
| 2.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] for record room
Average Run 6 Mtr [5(b)/E-25] ] | 5 | Points | 1,200 ₹6,000 | 1,140 ₹5,700 | 1,000 ₹5,000 |
| 3.00 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. on board [3(a)/E-24] ] | 4 | Points | 270 ₹1,080 | 265 ₹1,060 | 250 ₹1,000 |
| 4.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 6mtr [4(b)/E-25] ] | 10 | Points | 1,100 ₹11,000 | 1,072 ₹10,720 | 1,000 ₹10,000 |
| 5.00 | Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [D12/17] | 1 | Each | 950 ₹950 | 932 ₹932 | 2,500 ₹2,500 |
| 6.00 | Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Make- Legrand / Craptee), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (16A,Power Plug), [ 15/E-19] | 6 | Each | 2,600 ₹15,600 | 2,461 ₹14,766 | 2,250 ₹13,500 |
| 7.00 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Power plug), [9(a)/E-18] | 2 | Each | 580 ₹1,160 | 560 ₹1,120 | 800 ₹1,600 |
| 8.00 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(AC Point) [E-19/ 17] | 8 | Each | 965 ₹7,720 | 963 ₹7,704 | 1,350 ₹10,800 |
| 9.00 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc .[E-19/16] | 8 | Each | 440 ₹3,520 | 434 ₹3,472 | 425 ₹3,400 |
| 10.00 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17/5(a)] | 8 | Each | 175 ₹1,400 | 159 ₹1,272 | 200 ₹1,600 |
Tender Value
Refer Docs
EMD Value
₹14,246
Closing Date
19 Jan 2026, 1:30 pmClosed
Executive Engineer
Dist Hospital Campus Saktinagar Krishnagar Nadia
Partial modification Blood Centre at the premises of Santipur S.G Hospital, Santipur Nadia-- EI work and SITC of AC Machine
2026_WBPWD_983369_1
WBPWD/EE/NED/NIQ/e-T/43/ (2nd Call)25-26
Open Tender
ELECTRICAL WORKS ORG
30 days
Dist Hospital Campus Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹14,246
19 Mar 2026
5 Jan 2026
21 Jan 2026
5 Jan 2026
19 Jan 2026
5 Jan 2026
Dismalting of existing wiring, DB, switch board, fan , light fittings by expart electrician own's tools and tackeles.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] for record room Average Run 6 Mtr [5(b)/E-25] ]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. on board [3(a)/E-24] ]
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 6mtr [4(b)/E-25] ]
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. [D12/17]
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Make- Legrand / Craptee), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc (16A,Power Plug), [ 15/E-19]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Power plug), [9(a)/E-18]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(AC Point) [E-19/ 17]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc .[E-19/16]
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17/5(a)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required Make- Finolex / polycab/RR kabel) 2x36/0.3(2.5 sqmm) + 1x22/0.3 (1.5 sqmm) ECC [ 1(a) ii, / E-14 ]
2x56/0.3 (4 sqmm) + 1x 36/0.3 (2.5 sqmm) ECC [ 1(a)iii, / E- 14 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc.including supplying sockets, tapes. a)1.5 sq mm
b) 2.5 sq mm [9(i) / F-5]
c) 4 sq mm [9(ii) / F-5]
Fixing only single/twin fluorescent/LED light fitting in the ceiling fixed with “L” type MS clamp for RC ceiling / MS pipe as per GS direction of EIC [ 17/C-2 ]
Fixing only lamp [ 11/C-2]
Single fittings [Philips make Cat No. TMC-502P1xT-LED 22W P3241,incl. 1 no. 18W Master LED Tube (with 2 years warranty
Supply of Twin fittings [Philips make Cat No. TMC-502 P2xT-LED 22W P3242, incl. 2 nos. 18W Master LED Tube(with 2 years warranty
Supply 9 watt LED Lamp. Make-Philips
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: (12") [ 28(b)/C-4 ]
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [ 33/D-14 ]
Supply & Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed of 2 Core 6 sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- polycab /Havells. [F-2/1(a)]
Supply & Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. 2 core 6 sqmm cable. [F-1/2(a)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : Incl. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 core 6sqmm cable [F-4/7(a)] & [F-5/8(b) ii]
Supplying and fixing( 2+4) way double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. make- Legrand
Supplying and fixing 240 V DP MCB Isolator on din rail of existing DBs and necessary connection
Supplying and fixing 240 V ,6-32A SPMCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
SITC of 1.5 ton capacity Split Air-conditioner machine Non- inverter type fitted with Rotary compressors suitable for Refrigerant- R32/R410A of rated power supply 230 V-1 Ph- 50 Hz along with all accessories incl. supply & fixing required Angle Iron Structure on wall/ floor & mending works as per direction of E.I.C. and also necessary scaffolding arrangement incl. lifting, shifting for outdoor & indoor units of said AC machine or Approved by EIC). PCBs / control unit should be enclosed in a metal enclosure in the indoor unit of the AC machine.Make-O General / Mitshubishi Heavy / Mitshubishi Electric.
S & F of 240V, 1- ph timer DB Double door ( 2 + 10) Way SPNDB enclosure on wall as per -- ( Make - L&T, Cat no - LTSD14N ) incl. interconnection with suitable size of PVC insulated copper wire and neutral link & proviosion for earthing attachment. incl. proper socketting with required size of copper lugs and following accessories -- i) 240V 25 A DPMCB of Breaking Capacity 10 KA & ''C'' Charecteristics ( Make - L&T ) - 2 nos. ii) 25A, 2 Pole Power Contactor with 220 coil voltage ( Make L&T, Cat no - MNX - 25 - 2P, CS94190 ) - 2 nos. iii) Digital Time Switch ( Make - L&T, Cat No - Crono 67DDTO ) -1 nos. iv) One no. Red and One no. Green 240 V LED indicator lamp for indicating purpose of Auto & Bypass indication ( Make -- L&T ) v) Auto/Manuual Toggle Switch -- 1 nos. vi) S & F 4 way terminal lead on existing enclosure over the pvc insulated chairs with necy. nuts, bolts & washers. -- 2 nos. [ NS ] for Ac machine
Installation, testing & commissioning of the above-said 1.5/ 2.0 ton capacity split AC incl. supply & fixing required Angle Iron Structure on wall & mending works as per direction of E.I.C
Dismalting of existing 1.0T/1.5T AC machine ( indoor & outdoor unit ) and refixing the same at the new portion.
Supply & Laying of- 5/8" dia, 0.6 mm thick (for suction line) & 1/4" dia, 0.6 mm thick (for liquid /discharge line) Copper Refrigeration pipe (Make- Ryoku/ Rajko/ Mandev) with 9 mm thick nitryle rubber insulation (Make- Accroflex/ Supreme), 4 core x 2.5 sq.mm. FRLS unarmoured Copper Communicale cable (Make- Polycab/ Havells/ KEI/ Finolex/Gloster) incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5/2.0 TR Split AC machine and Supply & laying of PVC Drain Pipe 20/25mm dia by shaddling on wall incl. PVC "T", elbow, bend etc as per direction of E.I.C.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.19 MB
BOQ_2399393.xls
BOQ • 0.30 MB
form29111.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid