Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Sept 2026, 3:00 pm4d left
U N Mehta Institute of Cardiology & Research Centre
E-Tender For Rate Contract For Repairing of Split A.C., Refrigerator & Water Cooler For U. N. Mehta Institute of Cardiology and Research Centre.
332892
26 of 2026
Open
Miscellaneous Works
Works
Ahmedabad
2 documents required · 2 mandatory
₹1,180
U. N. Mehta Institute of Cardiology and Research Centre
₹30,000
11 Aug 2026
11 Aug 2026
11 Aug 2026
1 Sept 2026
11 Aug 2026
Part – A Labor Work of All type of A.C.
Simple Blower Service of Split A.C. with water (Indoor + Outdoor unit) (1 to 2.5 Ton)
Simple Blower Service of Cassette A.C. with water (Indoor + Outdoor unit) (2 Ton to 4 Ton)
Simple Blower Service of DX Unit with water (Indoor + Outdoor unit) (4 Ton to 8 Ton)
Simple Blower Service of DX Unit with water (Indoor + Outdoor unit) (8 Ton to 11 Ton)
High pressure Pump wash in Split A.C. (Indoor + Out Door) (1TR, 1.5 Ton, 2.0 Ton) (Chemical wash if required)
High pressure Pump wash in Cassette A.C. (Indoor + Out Door) (2.0 Ton, 4.0 Ton) (Chemical wash if required)
High pressure Pump wash in Ductable split Unit (Indoor + Out Door) (3 Ton to 5.5 Ton) (Chemical wash if required)
High pressure Pump wash in Ductable split Unit (Indoor + Out Door) (5.5 Ton to 11 Ton) (Chemical wash if required)
High pressure Pump wash service should be done after dismantle of split A.C. indoor (Chemical wash if required)
High pressure Pump wash service should be done after dismantle of Cassette A.C. indoor (Chemical wash if required)
High pressure Pump wash service should be done after dismantle of Ductable split A.C. indoor (Chemical wash if required)
Minor complain in Split A.C. i.e. Water Leakage, Noise, Wiring etc.
Installation of Split A.C indoor and outdoor without piping. - 1.5 Ton to 2 Ton
Installation of Cassette A.C. indoor and outdoor without piping .- 2 Ton to 4 Ton
Installation of Ductable split A.C. - 3 Ton to 11 Ton indoor and outdoor without piping
Dismantling of Split A.C.with indoor and outdoor A.C. - 1.5 Ton to 2 Ton
Dismantling of Cassette A.C. with indoor and outdoor - 2 Ton to 4 Ton
Dismantling of Ductable split A.C.with indoor and outdoor - 3 Ton to 11 Ton
Dismantling and Refitting of Split A.C. - 1.5 Ton to 2 Ton
Dismantling and Refitting Cassette of Split A.C.with indoor and outdoor - 2 Ton to 4 Ton
Dismantling and Refitting Ductable split of Split A.C. with indoor and outdoor- 3 Ton to 11 Ton
Part - B Repairing of All type of A.C. with spare parts
Fan Motor Dismantling, rewinding, Bushing, Refitting – All type of A.C. Outdoor
Fan Motor Dismantling, rewinding, Bushing, Refitting– All type of A.C. Indoor
Portable A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)1.0 Ton to 2.0 Ton
Split A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)1.0 Ton
Split A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)1.5 Ton
Split A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)2 Ton
Cassette A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)2 Ton
Cassette A.C. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)4 Ton
Ductable split Unit. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)3 Ton
Ductable split Unit. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)4 Ton
Ductable split Unit. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)5.5 Ton
Ductable split Unit. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)8.5 Ton
Ductable split Unit. Gas Charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) (R22, R32, R410 etc.)11 Ton
Removing, repairing and fitting of P.C.B circuit - 1.0 to 2.5 ton Non inverter split A.C.
Removing, repairing and fitting of P.C.B circuit - 1.0 to 2.5 ton inverter split A.C.
Removing, repairing and fitting of P.C.B circuit - 1 to 4 ton cassette A.C. Non inverter A.C.
Removing, repairing and fitting of P.C.B circuit - 1 to 4 ton cassette A.C. inverter A.C.
Removing, repairing and fitting of P.C.B circuit - 3 to 11 ton Ductable Split A.C. Non inverter A.C.
Removing, repairing and fitting of P.C.B circuit - 3 to 11 ton Ductable Split A.C. inverter A.C.
Removing and SITC of new capillary filter for all type of A.C 1 to to 11 ton.
Removing and SITC of new Dryer filter for all type of A.C 1 to 11 ton.
Part – C Supply, Installation, Testing & Commissioning of New spare parts of All type of A.C.
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Split A.C & cassette A.C 1.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Split A.C & cassette A.C 1.5 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Split A.C & cassette A.C 2.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Portable A.C 1.0 TR to 2.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of cassette A.C 3.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of cassette A.C 4.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Ductable split A.C 3.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Ductable split A.C 4.0 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Ductable split A.C 5.5 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Ductable split A.C 8.5 TR
Dismantling of existing outdoor fan motor with Supply, Installation, Testing, & Commissioning new outdoor fan motor of Ductable split A.C 11 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Portable A.C 1.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Split A.C 1.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Split A.C 1.5 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Split A.C 2.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Cassette A.C 1 to 2.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Cassette A.C 3 to 4.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Ductable split A.C 3.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Ductable split A.C 4.0 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Ductable split A.C 5.5 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Ductable split A.C 8.5 TR
Dismantling of existing Indoor fan motor with Supply, Installation, Testing, & Commissioning new Indoor fan motor of Ductable split A.C 11 TR
SITC New contactor of outdoor - 1 TR to 4
SITC New contactor of outdoor - 5 TR to 11TR
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 1.0 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 1.5 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 2.0 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 3.0 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 4.0 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 5.5 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 8.5 Ton
Dismantling of existing compressor with Supply Installation, Testing, & Commissioning of New Compressor with Gas Charges (SITC) : 11 Ton
Supply New Remote control for Split A.C
Supply New Remote control for Ductable split A.C
Supply New Outdoor stand wall mounted for Split A.C 1 to 2.5 ton
Supply New Outdoor stand floor mounted for Split A.C 1 to 2.5 ton
Supply New fabricated side flow Outdoor stand wall mounted for Split A.C 1 to 2.5 ton
Supply New Outdoor stand wall mounted for Cassette A.C 2 to 4 ton
Supply New fabricated side flow Outdoor stand wall mounted for Cassette A.C 2 to 4 ton
Supply New Outdoor stand floor mounted for Cassette A.C 3 to 4 ton
Supply New Outdoor stand wall mounted for Ductable split A.C 3 to 5.5 ton
Supply New Outdoor stand wall mounted for Ductable split A.C 6 to 11 ton
Supply New Outdoor stand floor mounted for Ductable split A.C 3 to 5.5 ton
Supply New Outdoor stand floor mounted for Ductable split A.C 6 to 11 ton
Removing with Supply Installation, Testing, & Commissioning of New P.C.B circuit for 1.0 to 2.5 TR split A.C.
Removing with Supply Installation, Testing, & Commissioning of New P.C.B circuit for 1.0 to 4 TR for Cassette A.C.
Removing with Supply Installation, Testing, & Commissioning of New P.C.B circuit for 3.0 to 11 TR for Ductable split A.C.
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 1.0 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 1.5 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 2.0 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 3.0 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 4.0 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 5.5 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 8.5 TR
Removing with Supply Installation, Testing, & Commissioning of New condenser coil with Gas Charge for 11 TR
Removing with Supply Installation, Testing, & Commissioning of New Automation Timer Controller.
Indoor swing flab Supply Installation, Testing, & Commissioning
Electrical contactor Supply Installation, Testing, & Commissioning
Removing existing Non Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Split A.C. PCB 1 to 2.5 ton
Removing existing Non Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Cassette A.C. PCB 1 to 4 ton
Removing existing Non Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Ductable split A.C. PCB 3 to 11 ton
Removing existing Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Split A.C. PCB 1 to 2.5 ton
Removing existing Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Cassette A.C. PCB 1 to 4 ton
Removing existing Inverter PCB with Supply Installation, Testing, & Commissioning of new PCB Ductable split A.C. PCB 3 to 11 ton
1/4",1/2",5/8",3/8" outdoor unit valve Supply Installation, Testing, & Commissioning with removal of existing valve
New fan blade for Split A.C. outdoor unit 1 to 2.5 ton
New fan blade for Cassette A.C. outdoor unit 1 to 4 ton
New fan blade for Ductable split A.C. outdoor unit 3 to 5.5 ton
New fan blade for all type of A.C. Ductable split outdoor unit 6 to 8.5 ton
New fan blade for A.C. Ductable split outdoor unit 8.5 to 11 ton
New fan Blower for Split A.C. Indoor unit. 1 to 2.5 ton
New fan Blower of Cassette A.C. Indoor unit. 1 to 4 ton
New fan Blower for Ductable split A.C. Indoor unit. 3 to 5.5 ton
New fan Blower of Ductable split A.C. Indoor unit. 6 to 8.5 ton
New fan Blower of Ductable split A.C. Indoor unit. 8.5 to 11 ton
Part - D Copper Refrigerant Piping
Supply, Installation, testing and commissioning including vacuumization and Nitrogen testing, vacuumization of Copper piping with electrical copper FRLS cable(Polycab, KEI,RR) and tube thickness 1.2 mm with insulation 6 to 19 mm thick. For 1.0 TR to 2.5 TR
Core cutting rate for 40 to 80mm
Part - E Labour Work and spare parts of water Dispenser
Service of Dispenser machine with cleaning.
Supply, Installation, Testing, Commissioning of New Compressor with Gas Charge (SITC) (Dispenser 20 Litre)
Pressure testing system Flushing, gas pump down, capillary & gas charge
Dispenser Tap (Plastic)
Supply 20 Litre bottle with cover
Hot water tank repairing with coil (20L)
New Thermostat 20 Litre Capacity Dispenser
Part – F Repairing of water cooler with spare parts
Service of Cooler machine with cleaning.
Removing, repairing and installing of fan motor - 80 Litre
Removing, repairing and installing of fan motor - 150 Litre
Removing, repairing and installing of fan motor - 400 Litre
SITC Gas charging of water cooler 80 Litre
SITC Gas charging of water cooler 150 Litre
SITC Gas charging of water cooler 400 Litre
Removing and SITC of capillary filter
All Type Of Body repairing work - 80 Ltr./150 Ltr./400 Ltr.
Part – G Supply, Installation, Testing & Commissioning of new spare parts of water cooler
Dismantling of existing compressor and Supply Installation, Testing, Commissioning of New Compressor with gas Charging (80 Litre capacity)
Dismantling of existing compressor and Supply Installation, Testing, Commissioning of New Compressor with gas Charging(120 Litre capacity)
Dismantling of existing compressor and Supply Installation, Testing, Commissioning of New Compressor with gas Charging(150 Litre capacity )
Dismantling of existing compressor and Supply Installation, Testing, Commissioning of New Compressor with gas Charging(250 Litre capacity )
Dismantling of existing compressor and Supply Installation, Testing, Commissioning of New Compressor with gas Charging(400 Litre capacity )
Supply, Installation, Testing, and Commissioning of fan motor with blade. (80 Litre capacity)
Supply, Installation, Testing, and Commissioning of fan motor with blade. (120 Litre capacity)
Supply, Installation, Testing, and Commissioning of fan motor with blade. (150 Litre capacity)
Supply, Installation, Testing, and Commissioning of fan motor with blade. (250 Litre capacity)
Supply, Installation, Testing, and Commissioning of fan motor with blade. (400 Litre capacity)
New running capacitor Suitable for 80 Litre capacity
New running capacitor Suitable for 120 Litre capacity
New running capacitor Suitable for 150 Litre capacity
New running capacitor Suitable for 250 Litre capacity
New running capacitor Suitable for 400 Litre capacity
New Thermostat suitable for 80/180/400 Litre Capacity
Dismantling and Supply, Installation, Testing, and Commissioning of New condenser with gas charge. 80 Litre
Dismantling and Supply, Installation, Testing, and Commissioning of New condenser with gas charge. 120 Litre
Dismantling and Supply, Installation, Testing, and Commissioning of New condenser with gas charge. 150 Litre
Dismantling and Supply, Installation, Testing, and Commissioning of New condenser with gas charge. 250 Litre
Dismantling and Supply, Installation, Testing, and Commissioning of New condenser with gas charge. 400 Litre
New fan blade only for water cooler (80 to 400 ltr)
PART H Labour work, Repairing, and new spare parts of All types of Refrigerator
SITC (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) Gas charging for Refrigerator (100 - 150 Ltr. Capacity)
SITC (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) Gas charging for Refrigerator (180 - 270 Ltr. Capacity)
SITC (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) Gas charging for Refrigerator (400 Ltr. Capacity)
Removing and SITC of capillary filter
All Type Of Body repairing work with colour work like Leakage, welding
PART I Supply, Installation, Testing & Commissioning of new spare parts of Refrigerator
Supply Installation, Testing, Commissioning of New Compressor with gas charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) - 100 to 150 Litre capacity
Supply Installation, Testing, Commissioning of New Compressor with gas charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) - 180 to 260 Litre capacity
Supply Installation, Testing, Commissioning of New Compressor with gas charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) - 270 to 350 Litre capacity
Supply Installation, Testing, Commissioning of New Compressor with gas charging (Nitrogen Pressure testing, Flushing, vacuumization, filter/capillary) - 400 Litre capacity
SITC New Thermostat (40 ltr to 400 ltr)
SITC of relay for freezer (40 ltr to 400 ltr)
Refrigerator stand (All type of fridge)
Fridge PCB repairing (40 ltr to 400 ltr)
SITC of PCB for all types of fridge (40 ltr to 400 ltr)
SITC New evaporator fan motor for fridge (200 to 400 ltr)
SITC New Condenser fan motor for fridge (200 to 400 ltr)
SITC new inside fridge Light ( 40 to 400 ltr) (Led Bulb)
SITC new inside fridge Light ( 40 to 400 ltr) (Led strip)
Part J:Supply ,Installation ,Testing and commissioning of Mortuary items
SITC of Mortuary temperature controller digital type-with one year warranty
Leakage rectification with vaccume and gas charging
SITC of Mortuary evaporator fan only
SITC of Mortuary evaporator fan with motor
1. The above mentioned quantity are tentative only and it may vary (Increase or Decrease) as per actual requirement and site condition.
2.Rate are invited for the repairing of split A.C., Refrigerator & water cooler at site of work at UNMICRC with Transporting, loading, unloading, stacking as and where required as per instruction of representative of UNMICRC including GST etc. complete.
3.Bidder Should provide One-year warranty of new indoor and outdoor fan motors.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
TED-Split A.C._Online.pdf
Technical compliance sheet.xlsx
XLSX
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].