| 1 | L1₹39.0 LAccepted-AOC 2ND 57 3190 E2 GALAXY CLIFFORD SOUTH CHALAVANOOR ELAMKULAM KADAVANTHRA P O ERNAKULAM KERALA 682 020 | ERNAKULAM | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹42.5 L+₹2.8 L (7.12%)Rejected-Finance KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L2 | Rejected-Finance Rejected being other than lowest tenderer | |
| 3 | L3₹42.6 L+₹3.0 L (7.55%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L3 | Rejected-Finance Rejected being other than lowest tenderer | |
| 4 | L4₹44.2 L+₹4.5 L (11.4%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest tenderer | |
| 5 | L5₹44.9 L+₹5.2 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest tenderer |
Tender Value
Refer Docs
Closing Date
6 Aug 2021, 6:00 pmClosed
Shri SK Choudhary IDSE EE GE NW Kochi
GE NW Kochi Kataribagh Naval Base Post Pin 682004
SPECIAL REPAIRS TO BUILDING NO P 26 AT NAVAL BASE KOCHI AND OTHER SANCTIONED WORK IN THE AREA OF AGE B R II AGE B R III UNDER GE NW KOCHI
2021_MES_456754_1
GE (NW) Kochi / 8312 / E8
Open Tender
Civil Works
Works
180 days
GE NW Kochi Kataribagh Naval Base Post Pin 682004
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW Kochi
Exempted
31 Oct 2021
3 Jul 2021
7 Aug 2021
4 Jul 2021
6 Aug 2021
23 Jul 2021
Amount
Dismantling single layer Mangalore pattern roofing tiles including ridges complete all as specified and as directed by Engr-in-charge.
Dismantling plain or corrugated steel sheeting, any guage, thickness including Nainital or similar pattern roof covering complete all as specified and as directed by Engr-in-charge.
Dismantling timber scantlings under 40 Sq cm in section for unframed work in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and as directed by Engr-in-charge.
All as per item No 3 here-in-before but over 40 Sq cm in section complete all as specified and as directed by Engr-in-charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed by Engr-in-charge.
Dismantling battens for tiles, shingels etc spaced exc 15cm of any size incl tilting fillets complete all as specified and as directed by Engr-in-charge.
M & L 2nd class hard wood weather boarding, clean sawn, plain, 20mm thick or feather edged 20mm complete all as specified and as directed by Engr-in-charge.
M&L for IInd class hard wood scantlings clean sawn 40 Sq cm and over in section in unframed work complete all as specified and as directed by Engr-in-charge.
All as per item No 8 here-in-before but except timber complete all as specified and as directed by Engr-in-charge.
M&L for IInd class HW plain fillets square or rectangular in section clean sawn, secured with nails, but bullnosed, splayed, chamfered or rounded on one edge or face area exc. 13 and n.exc 25 Sqcm complete all as specified and as directed by Engr-in-charge.
All as per item No 10 here-in-before but except fillets complete all as specified and as directed by Engr-in-charge.
Fixing only for IInd class HW sectional area exc 5 and n.exc 15 Sq cm clean sawn battens at 30 cm centres for mangalore pattern tiles complete all as specified and as directed by Engr-in-charge.
M&L for Rolled sections (Tublar sections) as in main and cross beams, hip and jack rafters; purlins , wall framing ,where connected to common rafters and fixed with angle cleats or other connecting plates complete all as specified and as directed by Engr-in-charge.
M&L for one coat of creosoting to old tiles battens any size and spacing prepared and treated all over (measured overall on one side only, spaces not deducted) complete all as specified and as directed by Engr-in-charge.
S&F 0.63 mm thick galvanised corrugated mild steel sheeting with two corrugation side lap, fixed with L-hook or cranked bolts complete all as specified and as directed by Engr-in-charge.
All as per item No 15 here-in-before but labour only complete all as specified and as directed by Engr-in-charge.
S&F prepainted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws as specified complete all as specified and as directed by Engr-in-charge.
S&F prepainted galvalume zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed by Engr-in-charge.
Taking down eaves gutters and rain water pipes of any size or any pattern including all fittings complete all as specified and as directed by Engr-in-charge.
S&F 180 mm dia of half round ready made eaves gutter of pressure rating 6 Kg/cm2 of approved make including necessary fitting like bend WC/ MS clips etc complete all as specified and as directed by Engr-in-charge.
S&F 150 mm dia of PVC (SWR) pipe single socketed in any length with rubber joints including necessary fitting like bend WC/ MS clips etc fixed on walls complete all as specified and as directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-charge.
M&L for Double charged vitrified tiles of size 800 x 800 x 9-10mm thick with approved pattern and colour borders over cement screed 10 mm thick in CM 1:4 over 25 mm thick PCC type B0 1:2:4 levelling course on RCC slab in inliving rooms complete all as specified and as directed by Engr-in-charge.
M&L cement concrete type B-1, 1:2:4 (20mm graded aggregate) 25 mm thick as in flooring with water proofing compound complete all as specified and as directed by Engr-in-charge. (WPC measured seperately)
All as per serial item No 4 here in before but on vertical surfaces as skirting over 10mm thick rendering in cement mortar 1:3 complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on brick/ concrete walls incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in-charge.
M&L for cement plaster 10 mm thick in cement mortar 1:6 finished even and smooth without using extra cement for internal faces of walls complete all as specified and as directed by Engr-in-charge.
M&L for cement plaster 15 mm thick in cement mortar 1:4 in two coats using WPC finished even and smooth without using extra cement for external faces of walls complete all as specified and as directed by Engr-in-charge.
Supply only integral water proofing compound complete all as specified and as directed by Engr-in-charge.
M&L for preparation new plastered internal surfaces and applying two coats of Interior Emulsion (Asian Rayale interior enulsion) over a coat of primer and 3mm thick wall care putty complete all as specified and as directed by Engr-in-charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L for preparation new plastered External surfaces for preparation of surface and applying two coats of weather proof (antifungal, Asian Ultima Protek) paint over a coat of suitable primer over 3mm thick wall care putty of three layer, complete all as specified and as directed by the Engineer-In-Charge. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
Dismantling wall and ceiling boards or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed by Engr-in-charge.
Supply, providing and fixing suspended false ceiling consisting of 8mm thick calcium silicate seamless board suspended on GI framework with staggered joints, GI framework to consist GI perimeter channel 25mmX20mm of 22 gauge along perimeter of false ceiling. Channel section of 50X25mm of 22 gauge and at 300mm centre to centre throghout one way fixed with screw/nut bolt and other direction 40x15 mm 22 gauge channel provided with interlocking with GI cleat and expansion fastnors including hangers 6mm dia GI fixed to roof truss, Boards are to be joined and finished so as to have a flush look which includes finishing the tapered and square edges of the gypsm board with joining compound paper tape and two coat plasting emulsion paint over one coat of primer and one layer of putty 3mm thick in three layers suitable for calcium silicate board( as per the recommendations/ practice) ncluding necessary scaf folding and shuttering complete as directed as specified and directed by Engr-in-Charge.
M&L for preparation of new Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of anti corrosive Epoxy paint over a coat of Epoxy primer, over a coat of red oxide on steel surfaces complete all as specified and as directed by Engr-in-charge. (Make-Asian Apcolite or Equal from Berger, Nerolac)
Taking down chowkats with shutter n.exc 1.5 Sqm each (without taking off shutters from the frame) complete all as specified and as directed by Engr-in-charge.
Taking down chowkats with shutter exc 1.5 Sqm but n.exc 4 Sqm each (without taking off shutters from the frame) complete all as specified and as directed by Engr-in-charge.
M & L Plain solid straight chowkats IInd class hard wood wrought framed rebated on the solid rounded or chamferred put together with glues pinned at joints etc complete all as specified and as directed by Engr-in-charge.
S & F Flush shutter 40mm thick solid core construction with block board core and plywood face panels covered with decorated face veneer on one face with lipping to match complete all as specified and as directed by Engr-in-charge.
S&F 2nd class hard wood, 35 mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. divided into squares with plain chamfered mitered and rebated sash bars any numbers, edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, section 8, clause 8.20 (a); supplied & fitted to Chowkats complete all as specified and as directed by Engr-in-charge.
S&F Powder coated anodised aluminium frame for door/window with or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engr-in-charge. Make : JINDAL or equivalent section from HINDALCO/INDALCO/MS AJIT IND PVT LTD
S & F Powder coated anodised aluminium window and ventilator shutters, fixed type/sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed by Engr-in-charge. Make : JINDAL or equivalent section from HINDALCO/INDALCO/MS AJIT IND PVT LTD
S & F Powder coated anodised aluminium 5mm dia hexagonal channel for grill fixed (decogrill) to aluminium frame with aluminium bidding complete all as specified and as directed by Engr-in-charge. Make : JINDAL or equivalent section from HINDALCO/INDALCO/MS AJIT IND PVT LTD
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty / beeding in squares exceeding 0.5 sqm each pane fix to wood/aluminium joinery complete all as specified and as directed by Engr-in-charge. Make: Hindustan Pilkinton glass Works Ltd/ Modiguard.
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed by Engr-in-charge.
S&F Solid PVC Door Frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed by Engr-in-charge.
S&F factory made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile) with wood free EPS, with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, S&F in frame at site as per specification & drawing complete all as specified and as directed by Engr-in-charge.
S&F MS door springs (Capsule type) 150 mm long and including roller and roller plate complete all as specified and as directed by Engr-in-charge.
S&F extruded aluminium alloy handles, 150 mm long fabricated type anodised complete all as specified and as directed by Engr-in-charge.
S&F alluminium, anodised, barrel tower bolts of extruded section of size 150 mm long complete all as specified and as directed by Engr-in-charge.
S&F aluminum anodoised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts etc complete of size 300mm complete all as specified and as directed by Engr-in-charge.
S&F 125mm S.S Butt hinges complete all as specified and as directed by Engr-in-charge.
Applying two coats of synthetic enamel paint over a coat of pink primer including preperation of new wooden surfaces complete all as specified and as directed by Engr-in-charge.
Cutting holes in brick wall built in CM for inserting hold fast etc and making good dismantled portion in CM 1:3 or PCC 1:2:4 type B1 with depth of embeded purline exc half brick but n.exc one brick complete all as specified and as directed by Engr-in-charge.
M&L PCC 1:3:6 type C1 as in anchorage block for hold fast complete all as specified and as directed by Engr-in-charge.
S & F for Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, hand made sliding bolts fixed in walls/pillars Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engr-in-charge.
Treating to back of chowkats are tarred exc 0.1 Sqm but n.exc 0.5 Sqm each complete all as specified and as directed by Engr-in-charge.
Treating to holdfasts n.exc 0.1 Sqm each complete all as specified and as directed by Engr-in-charge.
M&L for anti-skid rectified ceramic tile of size 400x400x8 mm thick over cement screed 10 mm thick in CM 1:4 with WPC as per manufacturer's instruction over 25 mm thick PCC type B0 1:2:4 levelling course on RCC slab complete all as specified and as directed by Engr-in-charge. (Note-WPC shall be measured and paid separately)
M&L for Glazed ceramic tiles in vertical surface 600x300x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering CM 1:3 complete all as specified and as directed by Engr-in-charge.
M&L for 25mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over 20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed by Engr-in-charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge.
M&L for 75 mm thick PCC 1:4:8, Type D-2 using 40 mm graded stone aggregate complete all as specified and as directed by Engr-in-charge.
M & L for chequered colour cement concrete tiles 20x20cmx 25mm thick set jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm 1:4 complete all as specified and as directed by Engr-in-charge.
Demolition and breaking up AC drain pipes 110 mm dia ( Salt glazed ware, AC or reinforced concrete) set in cement mortar complete all as specified and as directed by Engr-in-charge.
S&F PVC (SWR) pipes in 75mm. Dis single socketed, in any length with rubber ring joints, Fixed in wall/floor complete all as specified and as directed by Engr-in-charge.
S&F PVC (SWR) pipes (110mm) single socketed, in any length with rubber ring joints, fixed to wall/floor complete all as specified and as directed by Engr-in-charge.
PVC (SWR) bends with acces door any radius 110mm complete all as specified and as directed by Engr-in-charge.
PVC (SWR) bends with access door any radius 75mm complete all as specified and as directed by Engr-in-charge.
S & F for 110mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and as directed by Engr-in-charge.
S & F for 75mm dia PVC (SWR) branch piece, double (double Y) equal or unequal complete all as specified and as directed by Engr-in-charge.
S & F for 110mm PVC (SWR) vent cowl complete all as specified and as directed by Engr-in-charge.
PVC (SWR) junction single, (Single 'T') equal or unequal 110mm with access door complete all as specified and as directed by Engr-in-charge.
PVC (SWR) junction single, (Single 'T') equal or unequal 75mm with access door complete all as specified and as directed by Engr-in-charge.
S&F PVC (SWR) couplers 75mm complete all as specified and as directed by Engr-in-charge.
S&F PVC (SWR) couplers 110mm complete all as specified and as directed by Engr-in-charge.
S&F in repairs Vitreous China wash basin, white, flat back, size 550x400mm excluding taps, waste chain and plug and porcelain stopper but including brackets complete all as specified and as directed by Engr-in-charge. Make: Parryware cat No - C0578 White Colour/ Johnson Cat No-P0519PW/ Jaguar Cat No- URS-WHT-13261
Supply only 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engr-in-charge. Make-CERAParryware Cat No - T0802A1/Johnson Cat No- T2601C4/Jaguar Cat No- ARI-39011
S&F in repairs CP brass towel rail 60 cm long fixed complete all as specified and as directed by Engr-in-charge.
S&F in repairs vitreous china urinals coloured half stall type including all fittings complete all as specified and as directed by Engr-in-charge. Make: Parryware cat No - C0578 White Colour/ Johnson Cat No-P0519PW/ Jaguar Cat No- URS-WHT-13261
S&F in repairs PTMT urinal spreader of any colour suitable for 15 mm bore fixed with urinal including CP pipe complete all as specified and as directed by Engr-in-charge.
S&F in repairs Chinaware partition for urinal of size 310 x 700 mm complete all as specified and as directed by Engr-in-charge.
S&F in repairs Push tap high pressure suitable for urinals complete all as specified and as directed by Engr-in-charge.
S&F in repairs viterous China wash down water closet pan (pedestal pattern), white incl plastic water closet seat, black, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device, fixing bolts, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float & handle incl brackets, PVC connections 15mm size with PTMT nuts of length 600 mm and Flush pipe of polyethylene of low or high density or PVC 32 mm dia, for low level cistern complete all as specified and as directed by Engr-in-charge. Make-(EWC) Parry ware (Cat No-C844A White) or Cera (Cat No-3131 White) or Hindware (Cat No-92082 White)
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed by Engr-in-charge.
S&F hand shower (health faucet) with 8 mm dia 1 Mtr long flexible tube and wall hook complete all as specified and as directed by Engr-in-charge.make Parryware CAT No: T9961A1, cera CATnNo 8030101, jaguar ALD-CHR-573
S&F in repairs brass chromium plated bottle trap with inlet or outlet screwed for pipe for connection including necessary packing, union and cap (32 mm bore) complete all as specified and as directed by Engr-in-charge. make Parryware Cat No- T3203A1/Johnson Cat No- T0060C/Jaguar Cat No- ALD-769L300x190
M&L for providing, 75mm thick cement concrete, Type C1, 1:3:6 (using 20mm graded aggregate) for plinth protection complete all as specified and as directed by Engr-in-charge.
M&L for 10mm thick Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, for joints between bays complete all as specified and as directed by Engr-in-charge.
Demolition of brick work / PCC block masonry built in cement mortar including all quoins, arches, pillars, etc. all as specified and as directed by the Engr-in-Charge.
Pre-cast cement concrete block masonry with solid blocks in PCC 1:3:6, exc. 10 cm in width and setting in mortar in CM 1:6 complete all as specified and as directed by Engr-in-charge.
M & L formwork to sides and soffits of beams, lintels, cantilevers etc complete all as specified and as directed by Engr-in-charge.
M & L RCC type B1 1:2:4 (20 mm graded stone aggregate) in beams, cantilevers, lintel etc complete all as specified and as directed by Engr-in-charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, lintels hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-W (Gde E 250) Quality A or Fe-290 (Gde E-165) complete all as specified and as directed by Engr-in-charge.
S&F 6 to 8mm dia TMT bars in reinforcement cut to length, bent to shape required incl cranking, bending hooking and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-charge.
Dismantling structural steel work including of old main mast, doors, gates but excluding framed truss etc complete all as specified and as directed by Engr-in-charge.
S & F for Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. conforming with Fe-410- W(Gde- E-250) quality- B complete all as specified and as directed by Engr-in-charge.
M&L for applying anti-termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed by Engr-in-charge.
M&L for applying anti-termite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed by Engr-in-charge.
M&L for applying anti-termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed by Engr-in-charge.
Excavating in trenches in soft/ loose soil, n exc 1.5 m wide and n exc 1.5m in depth; for fdn, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25cm complete all as specified and as directed by Engr-in-charge.
Removing excavated soil material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engr-in-charge.
Demolition and breaking up of 150 mm dia drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed by Engr-in-charge.
M&L for reinforced concrete pipes class NP2 of 150 mm dia laid and jointed complete with collars complete all as specified and as directed by Engr-in-charge.
M&L for plain cement concrete Type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes (150mm bore pipe) after the pipe are laid and tested complete all as specified and as directed by Engr-in-charge.
M&L for precast cement concrete cover slab for man hole, in type B-1, 1:2:4 using 20 mm graded aggregate set in CM 1:6. (Reinforcement shall be measured and paid seperately) complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:3:6 type C-1 with using 20mm graded stone aggregate as in coping on walls, finished even and fair incl necessary form work all as directed by the Engr-in-charge.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement and sand mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge.
S&F Hume pipe septic tank 25 users capacity including necessary earth work in soft/ loose soil, PCC 1:3:6 in bed concrete with accessories like AC vent pipe, cowl manhole cover etc including connecting to the sewer line complete all as shown in drg No.TD/A/57 sheet 1/1 including removal of old septic tank and connected works complete all as specified and as directed by Engineer-in-Charge.
Dismantling fencing wire mesh, any type complete all as specified and as directed by Engr-in-charge.
Dismantling posts or struts (wood, steel of RCC) any section, including taking out embeded portion and making good disturbed ground, concrete , brick work, masonrycomplete all as specified and as directed by Engr-in-charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, in soft/ loose soil complete all as specified and as directed by Engr-in-charge.
S&F MS post and struts in fencing including cutting tops to sharp as directed, drilling holes, notching for wire etc and confirming to similar work Fe-290 grade E-165 complete all as specified and as directed by Engr-in-charge.
M&L for Plain cement concrete 1:2:4, type B2 (using 40mm graded aggregate) as in foundation, filling & mass concrete complete all as specified and as directed by Engr-in-charge.
Supply only Chain link MS galvanised fencing, including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by Engr-in-charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed by Engr-in-charge.
S & F for MS Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, fencing post and similar work etc. king rods and straining bolts conforming to Fe 290 Gde E-165 complete all as specified and as directed by Engr-in-charge.
M & L for Preparation of new steel surface of any description or n.exc 10cm in width or girth and applying 2 coat of anti corrosive Epoxy paint over a coat of Epoxy primer on steel surfaces complete all as specified and as directed by Engr-in-charge. (Make-Asian Apcolite or Equal from Berger, Nerolac)
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engr-in-charge.
M/L Cement concrete type C-2, 1:3:6 (40mm graded aggregate) ,75mm thick used in sub base complete all as specified and as directed by Engr-in-charge.
Surface excavation in soft and lose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed by Engr-in-charge.
Removal of excavated material (Soil) n. exc. 50 mtr and deposting where directed at level n.exc. 1.50 mtr above starting point complete all as specified and as directed by Engr-in-charge.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed by Engr-in-charge.
M&L for Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm under floors or in foundations spreading and levelling in layers n exc. 0.5 cm thick incl well ramming including watering as required complete all as specified and as directed by Engr-in-charge.
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS standards of 80mm thickness, M-40 grade, laid over with grey cement and pigments complete all as specified and as directed by Engr-in-charge.
M&L for providing cement concrete Type B0, 1:2:4 (using 12.5mm graded aggregate) as in kerb including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engr-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed by Engr-in-charge.
M&L point wiring using proper colour coding complete with 1100 Volts grade 1.5 Sqmm PVC insulated unsheathed FRLSH grade confirming to IS-694 multistranded single core copper conductor cable in PVC concealed conduit rigid non metallic medium grade of suitable size with all conduit accessories on wall except beam, column and RCC roof and chases cutting incl 2 mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylem top cover incl 1.5 Sqmm PVC insulated copper conductor earth continuity wire green colour for one light/fan point controlled by one switch complete all as specified and as directed by Engr-in-charge.
All as per item No 130 here-in-before but forOne 3 pin socket outlet, 5 Amps controlled by one switch in same board with other switches complete all as specified and as directed by Engr-in-charge.
All as per item No 130 here-in-before but for one 5 pin 5 amps socket outlet an independent board complete all as specified and as directed by Engr-in-charge.
All as per item No 130 here-in-before but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable on earth wire for one 6 Pin 16 Amps Socket outlet independent board complete all as specified and as directed by Engr-in-charge.
All as per item No 130 here-in-before but with 4 Sqmm copper conductor including 4 Sqmm copper cable on earth wire for one 3 Pin 16 Amps Socket outlet independent board complete all as specified and as directed by Engr-in-charge.
S&F switch piano flush type 5A one way complete all as specified and as directed by Engr-in-charge.
S&F S/S combination 5 pin 5 Amps flush type complete all as specified and as directed by Engr-in-charge.
S&F S/S combination 6 pin 15 Amps flush type multi purpose complete all as specified and as directed by Engr-in-charge.
S&F ceiling rose surface bakelite 65 x 50mm 3 terminals complete all as specified and as directed by Engr-in-charge.
Supply & fix ceiling fans complete with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete all as specified and as directed by Engr-in-charge. Make CG Cat Part Energion HS BLDC/Havells/UshaNote :-Old exhaust fans will be deposited in MES store yard
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and as directed by Engr-in-charge. Make havells turbo force sp /CG/Usha .Note:- Old exhaust fans will be deposited in MES store yard
S & F in repair fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed by Engr-in-charge.
Taking down old light fitting of any size complete all as specified and as directed by Engr-in-charge.
S&F Tubelight fitting 1 x20 w ,with T 8 LED tube with aluminium Extrusion heat sink for optimum performance with high luminous efficiency and batten pre wired suitable for use with LED tube with concealed accessories complete. including taking down old one complete all as specified and as directed by Engr-in-charge. . Make: Philips Cat part No;TMC501 P 20W 1XT LED P3241+ESSENTIAL LED TUBE 20W 1200MM 20W 865 T8 IND/HAVELLS/WIPRO
S&F 07W LED mirror light fitting with tube and provided with high output diffuser including all electrical connection all as specified and dirceted by Engineer in charge.Cat part no BN021C LED20S PSU CW GR S2 of Philips or Crompton/Wipro
Supply & fixing in repair building security light fitting LED 35 W ,IP 65,240 volts ,50 Hz including GI bracket for wall mounting complete all as specified and as directed by Engr-in-charge. Cat No-. ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC of Havells ,Bajaj,Philips .
S & F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified and as directed by Engr-in-charge.
Taking down old DBs from existing position including MCB,s complete all as specified and as directed by Engr-in-charge.
S&F Sheet metal enclosure SPN DB when MCB's to be used 8 way with 200 amps bus bar double door complete all as specified and as directed by Engr-in-charge.
S&F Sheet metal enclosure TPN DB when MCB's to be used 8way with 200 amps bus bar double door complete all as specified and as directed by Engr-in-charge.
S&F MCB TPN 63 amp ,415 volts ,16 KA complete all as specified and as directed by Engr-in-charge. Cat part No -BB40630B of L&T or Legrand/Indoasian
S&FMCB SPN 6 to 32 Amp ,240 Volts,10 KA complete all as specified and as directed by Engr-in-charge. Cat part No -BB20060B to BB20320B of L&T or Legrand/Indoasian.
S&FMCB Sp 6 to 32 Amp ,240 Volts,10 KA complete all as specified and as directed by Engr-in-charge. Cat part No -BB10060B TO BB10320B of L&T or Legrand/Indoasian
Taking down old sub main wiring of any size complete all as specified and as directed by Engr-in-charge.
M&L In repair sub main wiring on wall/ceiling with 2 runs of 2.5 Sqmm single core PVC cable as per IS 694-1990(third revision) insulated unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through in PVC conduit with all accessories such as Tees, elbows, junction box etc.as required of not less than 20 mm dia and 1 run of2.25 Sqmm single core PVC insulated unsheathed 1100 Volts grade, multistranded copper conductor FRLSH cable as earth continuity conductor and connecting to existing earth dolly with suitable size thimble and making good the disturbed surface to match with the existing including taking down of old sub main wiring complete all as specified and as directed by Engr-in-charge. Note : 3 runs of 2.25 Sqmm sub main wire and one run of PVC conduit pipes with accesories shall be measured as one unit.
M&L for sub main wiring with 4 runs of 16 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 16 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface complete all as specified and as directed by Engr-in-charge. Note -1. 4 runs of 16 Sqmm sub main wire and one run of 16 sq mm for earthing and PVC conduit pipe with accesories shall be measured as one unit.
M&L for sub main wiring with 2 runs of 4 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 4 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface complete all as specified and as directed by Engr-in-charge. Note -1. 2 runs of 4 Sqmm sub main wire and one run of 4 sq mm for earthing and PVC conduit pipe with accesories shall be measured as one unit.
M & L Taking down 1200/1400mm sweep ceiling fan, preparing the surfaces of ceiling fan by cleaning and filling the cavities with filler and applying one coat of synthetic enamel paint (Glossy finish) with spray gun, marking the MES No, fixing the fan in its original location, connecting up including provision of cable from ceiling rosse to connector to fan complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No ccomplete all as specified and as directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mmx6 mm thick burried directly in ground(earth pit not less than 2.25 metrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below ground level connected to galvanized iorn strip 25 x 4mmm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron steel all shown in electric plate No:3 (of SSR Part-i connected to earthing test pit all as specified or indicated including provn of necessery excavation and earth work in any type of soil, PCC pit ,RCC cover and frame, 20 mm bore medium grade watering pipe , water funnel, 40 mm bore GI medium grade protection pipe , common salt, charcol dust,returning, filling in of soil, removal of soil to a distance not exceding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-charge.
Taking down old stop valve,stop cock,bib cock ,swivel shower,from existing position including all fittings complete all as specified and as directed by Engr-in-charge.
S&F CPVC globe or gate valve 25 mm dia iron wheel head screwed both ends for PVC pipes complete all as specified and as directed by Engr-in-charge.
Supply & fix of concealed stop cock(half turn) with sliding flange CP fancy type of size 15mm complete all as specified and as directed by Engr-in-charge. Make:-CERA/JAGUAR/HINDWARE
Supply & fix of bib cock short body chromium plated with flange and aerator CP fancy type of size 15mm complete all as specified and as directed by Engr-in-charge. Make:-CERA/JAGUAR/HINDWARE
Supply & fixing of swivel shower of PTMT any colour with shower arm 15 mm size,195mm long with bend of 45 degree with flange of PTMT complete all as specified and as directed by Engr-in-charge.Make:-CERA/JAGUAR/HINDWARE
Supply & fixing of PVC connections 15mm dia size with PTMT nuts of length 450mm and taking down old one complete with brass union on both sides to suit 15mm GI pipe complete all as specified and as directed by Engr-in-charge.
S&F on wall / ceiling (concealed) CPVC pipe 25 mm dia SDR 11 & plain SDR 11 fittings complete all as specified and as directed by Engr-in-charge. Make:- Supreme
S&F on wall / ceiling (concealed) CPVC pipe 20mm dia SDR 11 & plain SDR 11 fittings complete all as specified and as directed by Engr-in-charge. Make:- Supreme
Taking down old unserviceable GI tubing of size 25mm complete all as specified and as directed by Engr-in-charge.
Taking down old unserviceable GI tubing of size 20mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs Ball brass valves (PTMT) of size 25 mm dia high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of Rotational mouldede polyethylene water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position of capacity 1000 liters complete all as specified and as directed by Engr-in-charge.
S & F MS tubular frames including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS 1161-1979 Gde St-240 and painted one shop coat of zinc primer including preparation of surfaces complete all as specified and as directed by Engr-in-charge.
S&F mild steel work as in plain angle plates for securing purlins , band, strap, hold fast, bolt and nuts, cleat, hook, hinges, base tie for foor frame, support or stay for rain water pipe etc and other similar items conforming to Fe-410-0 or Fe-310-0 complete all as specified and as directed by Engr-in-charge.
M&L for preparation of surfaces of new iron and steel surfaces of and two coat of synthetic enamel paint (ordinary tint) with a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
M&L for 75 mm thick type B-1,1:2:4 (20mm graded aggregate)complete all as specified and as directed by Engr-in-charge.
M & L for 15 mm thick screed bed or bedding layer in cement mortatr 1:4 for laying floor finishes finished even and rough suitable for laying floor tiles complete all as specified and as directed by Engr-in-charge.
M&L for Vitrified ceramic tiles 10 mm thick dark shade/double charged/ultra charged (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc, set and jointed neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for preparation of new plaster surfaces of wall and applying three coat of white wash on walls all as specified and as directed by Engr -in-Charge .
Expanded metal weight per sqm exc 4kg cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed by Engr-in-charge.
M&L in repair aluminium strip 25 x 3.15mm with porcelain insulators,saddles and fixing screws etc for roof conductor and down conductor above ground complete all as specified and as directed by Engr-in-charge.
M&L in repair 32 x 6 mm GI strip with saddles and screws etc complete all as specified and directed burried in ground /wall complete all as specified and as directed by Engr-in-charge.
M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed by Engr-in-charge.
Taking down old aluminium strip 25 x 3.15 mm with porcelain insulators,saddles and fixing screws and refixing the same etc for roof conductor and down conductor above ground complete all as specified and as directed by Engr-in-charge.
Taking down old GI strip 32 x 6 mm with saddles and screws and refixing same complete all as specified and directed burried in ground /wall complete all as specified and as directed by Engr-in-charge.
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws complete all as specified and as directed by Engr-in-charge. Note :- Including taking down old ones.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion directed as per engineer in charge.
Taking down old air Termination from existing position complete all as specified and as directed by Engr-in-charge.
Taking down old Test point from existing position complete all as specified and as directed by Engr-in-charge.
Taking down old U/s Earthing from existing position complete all as specified and as directed by Engr-in-charge.
Albert Rebello and Company
MS BUILDERS
T L ALOSIOUS
M/s ANTONY THOMAS AND CO
Vidya constructions
SUKU CONSTRUCTIONS
Oriental Constructions
ANIE JOHN CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .