AE LIDEW EDACHERY GP
AE LIDEW EDACHERY GP
RETENDER Annual Plan-Completion of Choyichiparambath Drinking water scheme under Edacheri Gramapanchayath. project S0226/24 dated 24/02/24-Choyichi parambath drinking water scheme under Edacheri GP-General Electrical Work-Kudivellapadathi
2025_LSGD_727745_2
4/AE/EDY/21/24-25
Open Tender
Civil Works - Others
Item Rate
180 days
AE LIDEW EDACHERY GP
Please refer Tender documents.
10 documents required · 10 mandatory
₹555
Yes
₹4,334
Yes
23 Apr 2025
8 Feb 2025
17 Feb 2025
8 Feb 2025
15 Feb 2025
8 Feb 2025
Amount
Choyichiparambath drinking water
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
90.14.24.17:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.2 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD276128/2024-2025:L&T water level controller single tank filling application 240 v
OD276129/2024-2025:Dry run protection for relay for submersible motor .360 v current based.. L&T , iAD or equivalentent
OD276137/2024-2025:Supply and fixing 65mm (2 1/2") GI Flange in the existing suction/delivery pipe using required leak proofing materials etc. as required.
OD276139/2024-2025:Supply, laying and fitting 50 mm 80 Sch ASTM pipe including "T" socket, adapter, suitable type solvent etc. as required at site,
OD276142/2024-2025:Supply and fixing 50mm 80 Sch ASTM Union Code
OD276144/2024-2025:Supply, installation, testing and commissioning of 2 1/2" Cast Iron Non Return Valve in the existing PVC/ ASTM pipe
OD276149/2024-2025:Supply and providing 200 mm plastic shade on the existing holder as required.
OD276151/2024-2025:Supply and fixing 50mm B class GI pipe as support for hanging submersible motor pump set in open well
OD276153/2024-2025:Supply and fixing 50 mm ( 2'') GI flange in the existing suction/delivery pipe line using required leak proofing materials etc as required
OD276154/2024-2025:Supply and fixing 75x63 mm PVC reducer
OD276155/2024-2025:Supply and fixing 75 mm PVC threaded adaptor male
OD276156/2024-2025:Supply and fixing 50 mm GM Ball valve in the existing ASTM pipe Zoloto make or equivalent
OD276157/2024-2025:Supply and providing 6 mm stranded steel rope for hanging submersible motor pump set
OD276159/2024-2025:Supply and installation of dust and vermin proof, 3 phase Syntax meter Board (GS-MB-6535) and to fix KSEB meters, fuse units,CT etc as required including fixing it on wall , making good the damageds colour washing et as required.
OD276161/2024-2025:Supply and providing Danger 415 V, 150x100mm Enameled danger plates
OD276162/2024-2025:Painting letters or figures with enamel paint as identification mark to SB,DB panel board etc as required
OD276164/2024-2025:Supply and providing LED indicator lamp (Blue, Red, Green, Black, Yellow, Orange colors)in the existing panelboard and giving connection Red ,Green, Black, Yellow, Orange
OD276165/2024-2025:Supply and providing 25x6 mm brass nut and bolt etc. as required
OD276166/2024-2025:Supply and providing 12x3 mm brass nut and bolt etc. as required
OD276167/2024-2025:Supply and providing the following type and power rated lamps in the existing fittings as required 9 W LED bulb
OD304502/2024-2025:Supply, installation , testing and commissioning of 3 phase , 5 hP vertical open well submersible pump set head range 29 to 60 metre with maximumum head of 60 metre, discharge 30000 litre per hour at 40 mtr head, 3 stage pump using chain block suitable tools and plants. (Deccan make 5 DE/3 model or equivalent make).
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
2.15.1:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD351502/2024-2025:Preparing and submitting the relevant documents in KSEB office including sketches and necessary drawings, filling the required proforma for service connection application, collecting the various documents and after obtaining the signature from the applicant. Remitting the application fee and the required amount . The required amount may be collected from Panchayath/Municipal office and hand over the receipt received from KSEB to the authorities.
OD351503/2024-2025:Supply and fixing of suitable MS Hook on outer wall of the building for tying the Gi wire used for supporting the wp wire from KSEB pole
OD351504/2024-2025: Supply and installation of 30cm long 25 x 3 mm size tinned copper earth bench with proper holes for the termination of earth conductors.
OD351505/2024-2025:Supplying and fixing flat iron clamps made of 40x6mm flat iron clamp of 40cm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
OD351506/2024-2025:Supply and fixing 63A,HRC fuse with 63A fuse link with connections, in the existing meter board
OD351507/2024-2025:Supplying and fixing 63A , 2 way neutral links mounted on DMC/SmMC base with connections, in the existing meter board
1.14.9:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
DINEESH M.P (BID ID -2108957)
Bidder Name
DASAN P
DINEESH M.P
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .