Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.8 L+₹1.7 L (11.7%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹15.9 L+₹1.7 L (12.0%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹17.6 L+₹3.4 L (24.2%)Rejected-Finance 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹17.9 L+₹3.7 L (26.2%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
25 Jun 2025, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT OF TUBE LIGHTS, SWITCH BOARDS, INTERNAL WIRING DISTRIBUTION BOARD, LIGHT FITTINGS AND ALLIED ITEMS IN OFFICE/OTM ACCN IN TECH AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2025_MES_710877_1
GE AF/AMB-T-17/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹60,000
Yes
22 Jul 2025
28 May 2025
27 Jun 2025
28 May 2025
25 Jun 2025
11 Jun 2025
Amount
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete fittings such as switches, C/roses, Pendants DBs, sockets etc. including taking down carefully by unscrewing from boards/outlet/DBs/fittings such as switches, sockets, lamp holders, brackets, ceiling fittings bulkhead fittings, sketch fittings, tube light fittings, fan regulator, electric meters, meter box any type etc as directed by Engineer-in-Charge. and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including non metallic rigid PVC conduit,medium grade minimum 20mm dia ISI marked and conduit accessories fixed concealed in wall/ceiling/roof etc with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheath top cover for mounting of fittings,switches,sockets outlets,regulators etc complete including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly for the following :-
One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed
One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed
One 3 pin switch socket combination on same board with other switches complete all as specified and directed
One bell point controlled by one bell push complete all as specified and directed
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
M&L for point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through including PVC casing caping and provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed
One light/fan/ controlled by one switch 6 amp one way complete all as specified and directed
One 3 pin switch socket combination 6 amp on the independent board complete all as specified and directed
One 3 pin switch socket combination on same board with other switches complete all as specified and directed
One bell point controlled by one bell push complete all as specified and directed
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board, complete all as specified and directed
M & L for point wiring on wall/ surface in steel conduit of size 20 mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including steel conduit with all accessories including provisining of 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches,sockets outlets,regulators etc complete all as specified and directed.
One light/fan/ controlled by one switch 6 amp one way, complete all as specified and directed
One 3 pin switch socket combination 6 amp on the independent board, complete all as specified and directed
One 3 pin switch socket combination on same board with other switches, complete all as specified and directed
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated & unsheathed cable 1100 volt grade and 2.5 sqmm FRLS PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board. complete all as specified and directed Notes For BOQ srl item No. 2 to 4 The rate of chase cutting and making good the surface will be deemed in the rates quoted by the contractor.
S&F in repair switch piano modular type 6 amp single pole flush type one way, complete all as specified and directed
S&F in repair switch piano modular type 16 amp single pole flush type one way complete all as specified and directed
M&L in repair for socket outlet modular type 3 pin 6 amp flush type complete all as specified and directed
M&L in repair for socket outlet modular type 3 pin 16 amp flush type complete all as specified and directed
S&F in repair modular step type fan regulator electronic type 120 watt 2 module complete all as specified and directed
S&F in repair modular cover plate with frame for 3 module complete all as specified and directed
S&F in repair modular cover plate with frame for 4 module complete all as specified and directed
S&F in repair modular cover plate with frame for 6 module complete all as specified and directed
S&F in repair modular cover plate with frame for 8 module complete all as specified and directed
S&F in repair modular metal flush box 3 module complete all as specified and directed
S&F in repair modular metal flush box 4 module complete all as specified and directed
S&F in repair modular metal flush box 6 module complete all as specified and directed
S&F in repair modular metal flush box 8 module complete all as specified and directed
M&L in repair for switch piano flush type single pole, one way 6amp complete all as specified and directed
M&L in repair for switch piano flush type single pole, one way 15 amp complete all as specified and directed
M&L in repair for socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed
M&L in repair for socket outlet 2 in 1 , 3 pin 5 A and 15 A flush type complete all as specified and directed
S&F in repair ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed
S&F in repair lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed
S&F in repair bell push flush type 230 Volt complete all as specified and directed
S&F in repair call bell ding dong 230 V single phase complete all as specified and directed
S&F in repair step type fan regulator electronic type in 5 step, 100 watt capacity switch/socket type complete all as specified and directed
S&F in replacement LED tube light fitting 1x18 watt, 230 volts in commercial channel with powder coated CRCA sheet housing with opal diffuser for LED with LED tube rod with high efficient LED in aluminium housing with clear & milky diffuser connecting with twin core twisted flexible copper conductor cable of suitable length of suitable size complete with all accessories complete all as specified and directed Note : The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 stranded luminaries efficiency 100 lumen/watt
Taking down/out old unserviceable FTL tube rod of any wattage and Supply and fixing LED tube rod 1x18 watt, 230 volts complete with all accessories all as specified. Note : The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 stranded luminaries efficiency 100 lumen/watt
S&F in replacement recess/Surface mounting LED flat panel 2'x2' with high efficient LED & glare free full window opal diffuser of 36 watt incl connecting with twin core twisted flexible copper conductor cable complete with all accessories all as specified. Note : The LED rod should Have PF >0.9 ,input voltage 90-300V, IP-20 , LM 80 stranded luminaries efficiency 100 lumen/watt
S&F in replacement indoor decorative LED batten with opal diffuser with inbuilt LED tube 10W and driver designed with high transmitting optics for even light distribution IP 20 degree protection having length 620mm and PF 0.9, CRI> 70, L 70 and connecting with twin core twisted flexible copper conductor cable complete all as specified and as directed
M&L for submain wiring in relacement with 2 runs of copper conductor FRLS PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed in new concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm FRLS multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site, complete all as specified and directed Note : Three runs of 4 sqmm cable alongwith conduit and conduit accessories will be measured as one length.
All as per BOQ srl item No 31 here-in-above but for 2x6 sqmm copper conductor FRLS cable and 1x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit 32 mm dia or higher conduit heavy duty complete all as specified and directed Note: Three runs of 6 sqmm cable alongwith conduit & conduit accessories will be measured as one unit.
All as per BOQ srl item No 31 here-in-above but for 4x6 sqmm copper conductor FRLS cable and 2x6 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in PVC conduit 32 mm dia or higher conduit heavy duty complete all as specified and directed Note : six runs of 6 sqmm cable alongwith conduit and conduit accessories will be measured as one length.
All as per BOQ srl item No 31 here-in-above but for 4x10 sqmm copper conductor FRLS cable and 2x10 sqmm copper conductor FRLS cable for earth continuity as a earth wire drawn in steel conduit 32 mm dia or higher conduit heavy duty complete all as specified and directed. Note : Six runs of 10 sqmm cable alongwith conduit and conduit accessories will be measured as one length.
S&F in replacement sheet metal enclosures for 4 way MCCB incomer + 12 module outgoings , vertical TPN load line distribution board with provn of mounting MCCB 100 amp incomer double door IP 54 protection As per IS 8623-III, 200 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces, complete all as specified and directed
S&F in replacement sheet metal enclosures for 8 way MCCB incomer +24 module outgoings , vertical TPN load line distribution board with provn of mounting MCCB 250 amp, 415 V incomer double door IP 43 protection As per IS 8623-III, 315 A rated bus bar blanking plates duly flush in wall and making good disturbed surfaces, complete all as specified and directed
S&F in replacement sheet metal enclosures for MCB distribution board 415 Volts three pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar including making the surface good complete all as specified and directed
S&F in replacement sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 4 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified and directed.
All as per BOQ srl item No.38 here-in-above but 8 way complete all as specified and directed
S&F in replacement MCCB four pole 415 Volts, 100 A, 16 KA complete all as specified and directed
S&F in replacement MCB three pole and neutral isolator 415 Volts, 63 A, 16 KA complete all as specified and directed
S&F in replacement MCBs 5 to 32 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
S&F in replacement MCBs 5 to 40 amp SP C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
S&F in replacement MCBs isolator 100 amp TPN C curve 415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
S&F in replacement MCBs isolator 63 amp SPN C curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB, complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6) type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. Note : (i) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department.
S&F in replacement plug top & socket with sheet metal enclosures Single pole including one MCB 20 Amp, 240 Volts,10 KA complete all as specified and directed
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspebded by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 6 sqmm sold aluminium conductor, complete all as specified and directed
All as per BOQ srl item No. 48.00 here-in-above but twin core 10 sqmm complete all as specified and directed
M&L for earthing complete with copper earth plate electrode 600mmx600mmx3.15 mm thick buried directly in ground earth pit not less than 3 mtr below ground level with top edge of earth plate not less than 2.25 mtrs below found level connected to copper earth strip of 20x3 mm by two means of nuts, bolts, thimbles, chuck nuts, washers test points including one end firmly fixed with earth plate by means of nut and bolts and other end of copper strip to test point GI watering pipe, 20mm dia duly plugged shall be projected out at least 20 cms above the ground level incl covering the earth electrode with charcoal dust salt all around not less than 15cm provision of earth pit RCC cover all as shown in electrical plate No. 5 of SSR Part I, 1991 etc incl necessary earth an disposal of surplus soil complete and testing all as specified and directed. Note : (i) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department.
S&F in repair Switch flame Proof rotary type with termination box in LM-6 16 A single Pole 240 V complete all as specified and directed.
S&F in repair LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement LED aviation light yellow painted die cast aluminium alloy housing red coloured polycarbonate dome and accessories 2x100 watt complete all as specified and directed
S&F in replacement industrial plug and socket 32 A 5 pin 8 module having protection IP 54, incl MCBs 4 pole duly fixed in wall complete all as specified and directed
S&F in replacement industrial plug and socket 63 A 5 pin 8 module having protection IP 54, incl MCBs 4 pole duly fixed in wall complete all as specified and directed
S&F in replacement energy efficient LED street light fitting, 35W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 35W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and directed
S&F in replacement street light GI pipe bracket 40mm dia 1.50m length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc, complete all as specified and directed
S & F LED lamp 7 watt complete all as specified and directed
S & F in replacement Hylam Sheet of size 6" x 6" complete all as specified and directed
S & F in replacement Hylam Sheet of size 11" x 6" complete all as specified and directed
S & F in replacement Hylam Sheet of size 12" x 14" complete all as specified and directed
S & F in replacement Hylam Sheet of size 10" x 12" complete all as specified and directed
S & F in replacement Hylam Sheet of size 11" x 13" complete all as specified and directed
S & F in replacement Hylam Sheet of size 9" x 6" complete all as specified and directed
S & F in repacement PVC round fan cover plate of size 6" to 8" or as per exiting size complete all as specified and directed
S&F in replacemennt LED 6W round/ square shape down llight recess mounting / surface mounting of existing size including fixing on ceiling complete all as specified and directed
S&F in replacemennt LED 12W round/ square shape down llight recess mounting / surface mounting of existing size including fixing on ceiling complete all as specified and directed
S&F in replacemennt LED 15W round/ square shape down llight recess mounting / surface mounting of existing size including fixing on ceiling complete all as specified and directed
S&F in replacemennt LED 10W bollard garden lights of existing shape with complete accessories/housing including PCC platform all as required all as specified and as directed by Engr in charge
S&F in replacement LED spot light 5 to 10W, 240V, AC complete including PCC plateform all as specified and directed at site by Engr in Charge
M&L for taking out/dismentling of old unserviceable check valve of pressure pump of capacity 0.5 to1 HP and supply and fixing of new check valve made of brass size 15/25/32mm dia complete all as specified and directed
M&L for taking out/dismentling of old unserviceable auto cut (pressure release valve) of pressure pump of capacity 0.5 to1 HP and supply and fixing new auto cut of suitable size complete all as specified and directed
M&L for taking out/dismentling of pressure pump of capacity 0.5 to1 HP from site and shifting to reputed workshop for rewinding after cleaning throughly with the same gauge of copper winding wire as well as number of turns and reassembling the pump after replacing unserviceable spare parts like bushe, shaft, fastener, bearing, capacitor and copper wire for putting pump in serviceable condition and replacing same to the place as directed. Note : spare parts, rewinding shifting and refixing is deemed to be included in quoted rate by contractor.
R N Enterprises (BID ID -3327825)
OMVIN ENTERPRISES LLP (BID ID -3326473)
The Rahul Vig (BID ID -3326628)
M/S Sonu Traders (BID ID -3329803)
PAUL REFRIGERATION (BID ID -3328298)
M/s R&R Enterprises (BID ID -3327920)
Haryana EngineerService (BID ID -3335716)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .