DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
M & R to E.I. in Director of Economics and Statics and CPL Building at Sector -18 Gandhinagar (As per requirnment for one year)
269396
16/18 of 2025/2026
Open
Electrical and Maintenance Works
Works
Gandhinagar
8 documents required · 8 mandatory
₹900
Yes
DEPUTY EXECUTIVE ENGINEER, CAPITAL PROJECT ELECTRICAL SUB DN NO 21, GANDHINAGAR
₹7,000
Yes
27 Jan 2026
27 Jan 2026
27 Jan 2026
9 Feb 2026
27 Jan 2026
Name of Work M & R to E.I. in Director of Economics and Statics and CPL Building at Sector -18 Gandhinagar (As per
requirnment for one year)
Fund Head : Deposit work
Sr. No. Item No. Particulars. Qty. Rate Amount
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Name Of Work :- M & R to E.I. in Director of Economics and Statics and CPL Building at Sector -18
Gandhinagar (As per requirnment for one year)
Item Estimated Rate in Rs.
Item Description Unit Amount in Rs.
No. Quantity in Figure In Word
Replacing old and u/s by Point wiring for Light / Bell with
2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of
pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, Rupees Four
erected on PVC / Metallic/Wooden box, single mounting
1 25 pts base frame covered with textured/metallic/white front 410.06 pts
plate modules erected on / in wall / ceiling as per pipe And Paise Six
erected, with necessary Lamp holder/ceiling rose / Only
H.D.Connector as directed.
(j) in existing pipe erected concealed in wall/ceiling
Cat. III (As Per Requirement)
Replacing old and u/s by Point wiring for FAN with 2-1.5
sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI
marked 1.1 KV Grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and
accessories with earth continuity of following type erected Rupees Five
on PVC / Metallic/Wooden box, single mounting base Hundred Fifty
2 5 pts 556.51 pts
frame covered with textured/metallic/white front plate Six And Paise
modules erected on / in wall / ceiling as per pipe erected.
with necessary ceiling rose / H.D.Connector as directed.
(j) in existing pipe erected concealed in wall/ceiling
Cat. III (As Per Requirement)
Replacing old and u/s by Point wiring for on board
Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic/Wooden box, single mounting Hundred Fifty
3 10 pts base frame covered with textured / metallic/white front 257.55 Seven And pts
plate modules erected on / in wall / ceiling with following Paise Fifty Five
type accessories Cat. III (As Per Requirement)
Replacing old and u/s by Providing following type of
Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame
4 covered with textured / metallic/white front plate
modules erected with necessary connections as per site
situation directed by Engineer In charge. (As Per
(1)One No. SP 6 Amp. Cat.III
80 nos 151.50 nos
(2) One No 5 pin plug Cat.III
40 nos 151.50 nos
(7) Blank Plate Single Cat.III
10 nos 25.25 nos
(9) 16 Amp. SP one way switch Cat.III
40 nos 180.79 And Paise nos
(10) 6/16Amp. Universal socket Cat.III
40 nos 199.98 Nine And Paise nos
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected on/in
wall or ceiling erected with necessary PVC fittings &
Junction boxes fixed with adhesive solution & Clamps
with following dia of pipes, in approved manner as
directed (As Per Requirement)
100 mtrs 24.24 mtrs
(b)25 mm Rupees Thirty
40 mtrs 33.33 mtrs
Providing & erecting PVC Corrugated Flexible Conduit
with required nos. of coupling, PVC bushes, Check-nuts
etc. complete of following sizes. (As Per Requirement)
(1) 20 mm Rupees
20 mtrs 17.17 Paise mtrs
Replacing old and u/s by Providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
7 to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated
stranded wire of green colour for earth continuity of
following size (As Per Requirement)
(E) in existing pipe (a) 2 wire 1.5 sq. mm Rupees Forty
50 mtrs 46.46 Six And Paise mtrs
(E) in existing pipe (b) 2 wire 2.5 sq. mm
150 mtrs 62.62 Two And Paise mtrs
Replacing old and u/s by providing and erecting Mains
with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
8 to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (As Per
(E) in existing pipe (a) 2 wire 4 sq. mm
25 mtrs 86.86 Six And Paise mtrs
Eighty Six Only
Supplying and erecting Flexible PVC insulated multi
9 strand multi core 1.1 kv grade ISI marked copper wires of
following size to be erected as directed.
(h) 2.50 Sq.mm 3 core round PVC sheathed (As Per
100 mtrs 77.77 And Paise mtrs
Replacing old and u/s by providing and erecting Mains
with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC
insulated conforms to IS 694, IEC - 227 erected in
10 existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
required. (As Per Requirement)
(f) One wire 10.00 sq. mm
20 mtrs 91.91 mtrs
Providing & Erecting 3mm thick Polycarbonate (PC)
sheet with grooving as directed (As Per Requirement) Rupees Three
11 1000 sq.inch 3.03 And Paise sq.inch
Replacing old and u/s by providing and erecting Rupees
Decorative call bell Ting-tong box type 250 volts complete Seventy One
erected (As Per Requirement)
12 15 nos 71.71 And Paise nos
Providing & erecting Switch board for Computer or
electric apparatus consisting of following modular type
accessories mounted with PVC / Metallic Rupees One
concealed/open box with single mounting base frame
covered with textured/metallic /white front plate,modules Thousand One
erected with necessary connections as directed Hundred Thirty
1 no. 6A/16A universal plug-switch combined. Three And
3 nos. 6A Switch
3 nos. 6A 5 pin Plug
For Modular Type Accessories Cat. III (As Per Two Only
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder coated and
high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more
than 0.95, THD < 15%,
14 CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.) (As
Per Requirement)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet Rupees One
Cat-lll All New Hundred Sixty
5 nos 165.64 nos
Sixty Four Only
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet Rupees Three
200 nos 373.70 Seventy Three nos
Replacing old and u/s by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a
heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast powder
coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD < 15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , Hundred Eighty
15 10 nos LED driver efficiency > 85 % 589.84 Nine And Paise nos
( fitting required LM-79 & LM-80 Certificates)(NOTE: Eighty Four
Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select Only
any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
(iii) 16-20 watts, Surge-2 KV Cat-lll (As Per Requirement)
(B) LED Panel Light with provision for Plane front frame
with translucent cover fixed to housing complete.IP20
(vi) 36 watts, 24" x 24", Surge- 2KV Thousand
Cat-lll (As Per Requirement) Seven Hundred
150 nos 1794.77 Ninety Four nos
Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 Rupees Six
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> Thousand
100 lumens/watt . LED driver efficiency > 85 %.( fittings Eighty Eight
required LM-79 & LM-80 certificates)(NOTE: Below And Paise
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) Only
(B) Flood Light (IP-65), Surge protection -4KV integral
and ,Light must have 440VAC line supply with over-
voltage protection.
(iii) Above 60 to 90 watts Cat-lll (As Per Requirement)
Replacing old and u/s by providing and erecting Miniature Rupees One
circuit breaker single pole 6A to 25A suitable to operate Hundred
on 240 V A.C. system and having breaking capacity
17 20 nos 112.11 Twelve And nos
KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark Cat.III (As Per Paise Eleven
Requirement) Only
Replacing old and u/s by Providing & erecting 240 V MCB
double pole switch for motor & inductive load (C Curve)
18 having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity (As Per
(B) 40 Amp. Cat.III
5 nos 330.27 And Paise nos
Replacing old and u/s by Providing & erecting 415 V
MCB Four Pole for Motor & Inductive Load (C Curve)
having 10KA breaking capacity & confirms to IS :8828 in Hundred Thirty
19 3 Nos existing box having following capacity (c)63 Amp. 737.30 Seven And Nos
Cat.III (As Per Requirement)
Replacing old and u/s by Providing and Erecting Plastic
enclosure fitted with DIN rail suitable for incorporating Rupees One
Three /Four nos. MCB (As Per Requirement) Hundred Eight
20 3 nos 108.07 nos
Replacing old and u/s by Providing and Erecting Sheets Rupees One
steel powder coated enclosure suitable for incorporating Hundred
One/Two nos. MCB. (As Per Requirement)
21 5 nos 176.75 nos
Replacing old and u/s by providing and erecting
Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand Rupees Two
capacity of 10 KA and suitable for operation on single Thousand Two
phase 240 V,50Hz. having characteristic of quick action &
22 2 nos 2235.13 Hundred Thirty nos
tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected Five And Paise
as directed Thirteen Only
(ii) 40Amps. DP Cat. III (As Per Requirement)
Providing and erecting HOT deep Galvanised iron strip
wire 8 to 16 SWG. (As Per Requirement)
23 10 kg 77.77 And Paise kg
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for
following type of applications with chamber and heavy
duty cover. (A)(approved make OEM has to submit test Rupees Four
certificate including value of earth resistance of Thousand Five
installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing
4591.46 Hundred Ninety nos
resistane mentioned in test Certificate) & having back One And Paise
filling compound of (B) Inner chemical (CCM Compound)- Forty Six Only
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long
time Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg. (As Per
Replacing old and u/s by Providing & erecting Approved
make Power Saving 50 Watt Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C. 50 Hz Thousand Nine
1200 mm sweep complete having 3blades with Hundred Forty
25 10 nos aluminium blades with , canopy & 30 cm. down rod 1948.29 nos
erected with earthing.(Make shall be approved by
Engineer in charge)) Paise Twenty
Replacing Old & u/s by new Providing 2.5mm.thick Rupees
laminated acrylic sheet to cover the fan hook or Fan box. Eighteen And
26 10 nos (As Per Requirement) 18.18 nos
Replacing old and u/s by Supplying & erecting approved
make low noise decorative exhaust fan having square
frame ABS body with inbuilt lowers & square Thousand
frame.200mm with 1350RPM Cat.II (As Per Seven Hundred
27 5 nos Requirement) 1703.87 nos
Replacing old and u/s by Providing and erecting XLPE Rupees One
(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Hundred Forty
Aluminium conductor for 1.1 KV. to be laid on wall with
28 100 mtrs 140.39 And Paise mtrs
necessary clamps or in existing trench / pipe of following
size of cables Thirty Nine
(C) 4 core 10 Sq. mm (As Per Requirement) Only
Making trench in soft soil of suitable width of 90 cm deep
for laying cable or locating the fault all over the run and Rupees Fifty
29 50 mtrs back filling the same and making the surface as normal 55.55 Five And Paise mtrs
ground. (As Per Requirement) Fifty Five Only
Drilling the road without breaking the road surface
(Asphalt) for laying of cable for feeding power supply by
making up to following size of holes at both ends Hundred Ninety
30 10 mtrs complete. 492.88 Two And Paise mtrs
(A) Up to 100 mm bore dia (As Per Requirement)
Providing and, fixing heavy duty flange type brass cable Rupees Thirty
gland with rubber ring for PVC insulated armoured cable Eight And
31 10 nos complete with out going tails, insulating tape etc for 38.38 nos
following size of cables. Paise Thirty
(C) 2 to 4 core 10 Sq. mm (As Per Requirement) Eight Only
Solder less crimping type Aluminium lugs conforming to
IS suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals Thirteen And
32 40 nos 13.13 nos
with brass/cadmium plated nut bolts in an approved Paise Thirteen
(B) 10 Sq.mm (As Per Requirement)
Replacing condenser for ceiling fan/ Exhaust Fan /
Pedestal Fan / Table Fan / Cabin Fan {Credit of D.M. Rupees Sixty
33 80 nos retained by Agency.} (As Per Requirement) 64.64 Four And Paise nos
Sixty Four Only
Supplying & erecting approved make SMC press
moulded composite FRP. loop-in, loop-out approx. 2mm
thick box complete with Bakelite connector strip Rupees Eight
5way(3P+N+E),DIN rail for mounting mob & hinged Hundred Ninety
doors as per requirement having locking arrangements
34 15 nos 898.90 Eight And nos
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of Paise Ninety
following size of box. Only
(A) 300mm x 200mm x 100mm [deep] (As Per
Replacing Old u/s by new Supplying & erecting approved
make Digital time switch having lithium cell 6 years
operative and operate battery backup 1 channel day Rupees Three
clock with 14 memory programme, suitable to operate on Thousand One
240V + 5%, 16A with, floating contacts Minimum Hundred Sixty
35 2 nos switching setup time 1 minimum & LCD display. Also 3168.37 nos
comprised permanent ON/OFF switching. Programming Eight And
switches & housed in fire proof thermoplastic enclosure & Paise Thirty
transparent cover erected as required with necessary Seven Only
connection erected as directed. (As Per Requirement)
Replacing Old u/s by new Supplying & erecting power
contactor ,AC3 duty for time switch complete erected as
per direction Cat III Thousand
(D) 4 pole 440V 40 Amp. (As Per Requirement) Seven Hundred
36 2 nos 2782.55 nos
Paise Fifty Five
Replacing Old U/s By New Providing and erecting
Approved make Four pole moulded case circuit breaker Rupees Six
having breaking capacity ICU of 25 KA. at 415 V,having
normal current rating up to 25 A to 100A. with Fixed Thousand One
thermal & magnetic release suitable to work on A.C. Hundred
37 1 nos 6173.12 nos
supply 50 c/s. with all internal connections, spreader Seventy Three
tinned copper & complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III (As Per Twelve Only
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be Rupees Nine
laid on wall with necessary clamps or in existing trench / Hundred Four
38 25 mtrs 904.96 mtrs
pipe of following size of cables And Paise
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Ninety Six Only
(F) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core) Rupees Five
50 mtrs 540.35 And Paise mtrs
Replacing Old U/s By New Providing and erecting
Approved make Four pole moulded case circuit breaker
having breaking capacity ICU of 35 KA. and above at 415 Rupees Twenty
V . having normal current rating 250A. with variable
thermal & magnetic release suitable to work on
A.C.supply 50 c/s. with all internal connections, spreader Hundred Forty
tinned copper & complete erected in existing 16 G.M.S. Six And Paise
housing. Thirty Nine
ICS=100% of ICU only Cat III
RUPEES IN WORDS Rupees Six Lakh(s) Ninety Five Thousand One Hundred Eleven And Paise Twenty Nine Only
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Estimated amount put to tender Estimated amount put to tender
Deduct……………………….. % Below Add……………………….. % Above
In words In words
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work
5 Dismentaling the existing material taken by contractor as mention rates.
Signature of Contractor Deputy executive Engineer
C.P Electrical R & B Sub Dn
Less for the D.M
Name of work:- M & R to E.I. in Director of Economics and Statics and CPL Building at Sector -18
Gandhinagar (As per requirnment for one year)
Sr.no Item Qty. Per DM rate Total
1 Cost Of Old & u/s Light Pts. 25 Pts. 12.48
2 Cost Of Old & u/s Fan Pts. 5 Pts. 18.28
3 Cost Of Old & u/s Looped Plug 10 Pts. 8.76
4 Cost Of Old & u/s 6A Switch 80 Nos. 5.60
5 Cost Of Old & u/s 6A Plug 40 Nos. 5.60
6 Cost Of Old & u/s Blank Plate 10 Nos. 1.00
7 Cost Of Old & u/s 16A Switch 40 Nos. 6.76
8 Cost Of Old & u/s 16A Plug 40 Nos. 7.52
9 Cost Of Old & u/s 1.5 Mains 50 Mtr. 3.78
10 Cost Of Old & u/s 2.5 Mains 150 Mtr. 5.22
11 Cost Of Old & u/s 4 Mains 25 Mtr. 7.20
12 Cost Of Old & u/s 2.5x3Core Wire 100 Mtr. 6.75
13 Cost Of Old & u/s One Wire 10 Mains 20 Mtr. 7.92
14 Cost Of Old & u/s Computer Board 20 Nos. 42.72
15 Cost Of Old & u/s Ting Tong bell 15 Nos. 2.60
16 Cost Of Old & u/s 5 to 10W Tubelight 5 Nos. 5.52
17 Cost Of Old & u/s T-5 Tube light 200 Nos. 18.00
18 Cost Of Old & u/s Downlight 16-20W 10 Nos. 22.00
19 Cost Of Old & u/s 36W Panel Light 150 Nos. 69.72
20 Cost Of Old & u/s MCB SP 20 Nos. 4.90
21 Cost Of Old & u/s 40A DP MCB 5 Nos. 14.00
22 Cost Of Old & u/s 63A FP MCB 3 Nos. 35.20
23 Cost Of Old & u/s Enclosure FP 3 Nos. 4.70
24 Cost Of Old & u/s Enclosure DP 5 Nos. 8.10
25 Cost Of Old & u/s 40A DP ELCB 2 Nos. 108.50
26 Cost Of Old & u/s 4x10 sq.mm Al. Cable 100 Mtr. 8.13
27 Cost Of Old & u/s 1200mm Ceiling fan 10 Nos. 169.02
28 Cost Of Old & u/s 200mm Ex. Fan 5 Nos. 147.24
29 Cost Of Old & u/s Timer 2 Nos. 123.76
30 Cost Of Old & u/s Contactor 2 Nos. 109.16
31 Cost Of Old & u/s 25 to 100A MCCB 1 Nos. 299.20
32 Cost Of Old & u/s 250A MCCB 1 Nos. 1030.55
Dy.Executive Engineer Exe.Engineer
Sign of Contractor Cap.Proj. Elect.sub.Div-21 C.P.Electrical Division
Gandhinagar Gandhinagar
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
Notice 16 ONLINE.pdf
PQ.pdf
SCHEDULE A B AND DM.pdf
STANDARD BIDDING DOCUMENT.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .