Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L 1 | Accepted-AOC Lowest One work order issued on 05.04.2023 |
| 2 | L 2₹2.9 Cr+₹7.5 L (2.62%)Rejected-Finance | ₹2.9 Cr+₹7.5 L (2.62%) | L 2 | Rejected-Finance Second Lowest Unsuccessful tenderer EMD amount to be refunded |
| 3 | L 3₹2.9 Cr+₹7.5 L (2.62%)Rejected-Finance 53 MIDDLE STREET ARUMALAI TIRUKOILUR VILLUPURAM DISTRICT | VILLUPURAM | TAMIL NADU | 604001 | ₹2.9 Cr+₹7.5 L (2.62%) | L 3 | Rejected-Finance Third Lowest Unsuccessful tenderer EMD amount to be refunded |
| 4 | L 4₹3.1 Cr+₹19.3 L (6.77%)Rejected-Finance | ₹3.1 Cr+₹19.3 L (6.77%) | L 4 | Rejected-Finance Fourth Lowest Unsuccessful tenderer EMD amount to be refunded |
Tender Value
₹3.5 Cr
EMD Value
₹1.8 L
Closing Date
1 Mar 2023, 6:00 pmClosed
Superintending Engineer South Circle TNPHC Ltd
Tamil Nadu Police Housing Corporation Limited No 1 Inspector Quarters TSP VI Battalion Campus New Natham Road Madurai 625014
Construction of Trichy Regional Office building with development works for Tamil Nadu Co-Operative State Agriculture and Rural Developmnet Bank at Trichy in Trichy District
2023_TNPHC_290166_1
SE/SC No.55/2022-2023-1
Open Tender
Civil Works
Lump-sum
335 days
TRICHY IN TRICHY DISTRICT
Refer tender documents
7 documents required · 7 mandatory
₹0
₹1.8 L
7 Apr 2023
23 Feb 2023
3 Mar 2023
23 Feb 2023
1 Mar 2023
23 Feb 2023
Amount
1.1) Earth work excavation for foundation in all soils (including refilling) a. 0 to 2 mt.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
13.1) Filling with excavated earth
21.2) Teak wood Wrought & Put up a. T.W. over 2.00 m & below 3.00 m
b. T.W. below 2.00 m length.
23.3) Supplying and fixing of Magnetic door catches
24) Manufacturing & supply of steel windows (weight basis)
25) Supplying and fixing of MS hold fast
30) Finishing the top of flooring with cement concrete 1:3, 20mm thick Ellispattern flooring (No sand)
31) Weathering course over roof slab with proportion of brick jelly 20mm to lime (32:12 1/2) by volume
37.1) White washing 3 coats (slaked)
39) Supplying and fixing of MS Grills in position
40) Painting 2 coats - New "wood work"
41) Painting 2 coats - New "iron work"
46) Supplying and fixing of 20 mm dia Alu. Hanger Rod
47) Supplying and fixing of Alu. Towel rail 75 cm long
48) Supplying and fixing of 5 pin Coat stand
49) Supplying and fixing of Chromium plated 8 gauge picture hook
50.3) Supplying and planting avenue trees
50.4) Providing Tree guard
52) Supplying and laying of PVC Water supply (ASTM) pipe a. 32 mm dia
b. 25 mm dia
53.3) Supplying and fixing of C.I. steps (5 Kg)
Electrical arrangements 69) Supplying and fixing of 15 Amps 3 pin Power plug socket
72) Supplying and fixing of Box type Fibre Fan hook
74) Charges for assembling and fixing of ceiling "Fan"
76) Supplying and fixing of 8 SWG G.I. wire
77.3) Supplying and fixing of TV/Telephone line Socket
77.4) Supplying and fixing of 20mm dia PVC pipe for TV/Telephone line
78) Providing Earthing Station using pipe electrode as per IS3043 (Type I)
81) Supplying and fixing of meter cupboard with best Country wood double leaves shutters
86) Providing Pre-constructional Anti termite treatment
Annexure 2.1.1) Supplying and filling the basement with gravel
2.1.3) Supplying and filling in foundation and basement with Crushed stone sand
2.1.6) Supplying of Stone dust
3.1.1) C.C.1:5:10 using 40mm size HBSJ for Foundation & Basement using crushed stone sand
4.4.1) Standardized Concrete mix M20 Grade using crushed stone sand with Admixture a. In Foundation and basement
6.6.1) Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture
8.4.1) Standardized Concrete mix M20 Grade using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
9.6.1) Brick work in C.M. 1:6 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
10.6.1) Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7 cm (8 ¾"x4 ¼ "x2 ¾") 110 mm tk (B.P.) using crushed stone sand with Admixture a. In Foundation and basement
b. In Ground Floor
c. In First Floor
d. In Second Floor
11.6.1) Brick work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼ " x 2 ¾ ") 70 mm tk using crushed stone sand with Admixture (B.P.) a. In Ground Floor
b. In First Floor
c. In Second Floor
12.1.1) Brick partition work in C.M. 1:4 using kiln burnt Country bricks of size 22 x11x 5 cm (8¾ "x 4¼ "x 2") 50mm tk using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
c. In Second Floor
d. In Third Floor
14.2.2) Precast Cupboard slab 20mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand with Admixture 20mm thick a. In Ground floor
b. In First floor
c. In Second floor
14.2.3) Precast Cupboard slab 40mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand with Admixture 40mm thick a. In Foundation & Basement
16.1.1) Precast Jally ventilator 50mm thick using standardised concrete mix M20 Grade using crushed stone sand with Admixture a. In Ground Floor
18.1) Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
c. For Square and rectangular columns and small quantities
d. For Vertical wall
f. For Curved surface
21.5.3) Supplying and fixing in position of UPVC window of casement type (open) for all sizes
21.5.4) Supplying and fixing in position of UPVC louvered ventilator type for all sizes
22.2.2) Teak wood glazed shutter for french window with 5.5mm thick plain glass a. 1.80 x 2.10 m openable
22.3.4) Supplying and fixing of openable type Double leaf four compartment Cupboard shutter
22.9.3) Solid core TW flush door with Teak ply on both sides and TW lipping alround (35mm thick) single leaf shutter Suitable for door of size a) 750 x 2400mm
22.9.4) Supplying and fixing of single leaf fully solid core WPC door shutters with WPC Single leaf shutter Suitable for door of size 750 x 2100mm
22.9.5) Supplying and fixing of single leaf fully solid core WPC door shutters with WPC Single leaf shutter Suitable for door of size 900 x 2400mm
26.1) Flooring in C.C.1:5:10 using 40mm size HBSJ using crushed stone sand
28.1) Finishing the top of flooring in C.M. 1:4, 20mm thick. using crushed stone sand with Admixture
29.8.1) Supplying and fixing of Glazed tiles using Grout (Tile Joint Filler) using crushed stone sand
29.9.1) Supplying and laying of Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler). using crushed stone sand
32.1.1) Pressed tiles (23cmx23cmx20mm thick) mixed with water proofing compound @ 2% by weight of cement using crushed stone sand
33.1) Plastering in C.M. 1:5, 12 mm tk. using crushed stone sand with Admixture
34.1) Plastering in C.M. 1:4, 12 mm tk. using crushed stone sand with Admixture
35.1.1) Plastering in CM 1:3, 12 mm tk. with Admixture and mixed with WPC using crushed stone sand
35.2) Spl. Ceiling plastering in C.M 1:3, 10 mm tk. using crushed stone sand with Admixture
36.1) Plastering for Border in C.M. 1:5, 12 mm tk. using crushed stone sand with Admixture a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.4.2) Supplying and applying Wall putty (one coat) over the new cement plastered walls
43.1) Supplying, Fabricating and fixing of Mild steel / RTS grills (without cement slurry wash) reinforcement for all sizes of rods
44.2.1) Rain water harvesting using defunct borewell and providing perforated cover slab in Standardised concrete mix M20 Grade by using 3mm-10mm HBGS Jelly using crushed stone sand with Admixture a) Providing pit
b) Augering 30cm dia
44.6) Supplying and fixing of PVC SWR 110 mm dia with ISI mark type-A for rain water down fall pipe
50.2.1) Providing precast Kerb stone in C.C. 1:3:6, 450x300x150 mm using crushed stone sand
50.5.1) Supplying fabricating and erection of M.S Scheme name board using crushed stone sand with Admixture
50.6.1) Precast slab 50 mm tk.in C.C.1:3:6 mixed with fibre using crushed stone sand
52.4) Supplying laying fixing and jointing the following PVC pipes as per ASTM D-1785 of schedule 40 threaded PVC water supply ASTM pipe (fully consealed in walls) with necessary PVC/GI specials c. 20mm dia
53.4) Supplying and fixing of CI Manhole cover of size 60 x 60cm (50kg weight)
53.5.1) Supplying and fixing of Oval Shape Wash Hand Basin (white) of size 560 x 450mm with all accessories
54.1.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (long body)
54.2.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (Short body)
56.3.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade 'P' or 'S' trap - in G.F. using crushed stone sand
56.4.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade 'P' or 'S' trap - Other than G.F. using crushed stone sand
56.4.4) Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet
57.2) Supplying and fixing of EWC (White) 500mm with PVC SWR grade "P" or "S" Trap
57.2.1) Supplying and fixing of EWC (white) Rimless Bowl for coupled WC superior variety 380x660x850mm with UF soft closing slim seat cover
58.3) Supplying and fixing of PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia
58.4) Supplying, Laying & Concealing the 50mm dia PVC (SWR) pipe with ISI mark type - 'B' with relevant specials.
59.5.2) Supplying and fixing of Gully Trap using crushed stone sand
60.1) Supplying and fixing of PVC Nahani trap (4way/2way)
61.1.1) Supplying and fixing of UPVC Non Pressure Pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a) 110mm dia UPVC Non Pressure pipe
b) 160mm dia UPVC Non Pressure pipe
62.1.1) Supplying and fixing of PVC Bend fabricated 6 KSC PVC specials as per IS 10124/1982 Part II a) 110mm dia PVC Bend
b) 160mm dia PVC Bend
62.2.1) Supplying and fixing of PVC Equal Tee (mould) BIS 7834/1975 PVC specials as per IS 10124/1982 Part-II a) 110mm dia PVC Equal Tee
b) 160mm dia PVC Equal Tee
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan Point
66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Switch Board Itself.
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Convenient Places.
71.2) Supplying and fixing of 32 Amps triple pole main switch
75.1.2) Supplying and delivery of fan with electronic dimmer with ISI mark a) 48" (1200mm) sweep
77.6) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed.
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed
80.1) Supplying and fixing of 450x375x20mm T.W. plank
84.4) Run of Main 4 wires of 6 Sqmm PVC insulated unsheathed single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
87.1) Supplying and fixing of Three Phase ELCB/RCCB
87.2) Supplying and fixing of 20 Amps DP plug and socket in sheet enclosure with 32A DP MCB in Flush with wall with earth connection (For AC Plug)
90.2) Providing additional strutting to centering of plain surface
97.1.1) Supplying and fixing of Aluminium Partition wall 1/3, 5.5 mm thick plain glass & 2/3 Novapan - 12mm thick
97.2.3) Supplying, Fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf door panelled with 12mm thick Novapan sheet at bottom (0.9x0.75m) and glazed using 5.50mm thick plain glass at top (0.90x1.20m) Suitable for door of size a. 1000mm x 2100mm
99.4) T.W.double leaves Panelled door shutter with brass fittings Suitable for door of size a. 1500 x 2400mm
100) Supplying and fixing of 9 watts LED Bulb
101) Supplying and fixing of 25 watts LED bulb with street light fittings
102) Supplying and fixing of 4'18 watts crystal LED tube light
103) Supplying and fixing of Bulk Head fitting suitable for 12 watts LED bulb
104) Supplying and fixing of 12 watts bulb lamp for bulk head fittings
105.1) Run off main 4 wires of 4 Sq mm. (EB service connection)
110) Supplying and fixing of Single Pole MCB 6A to 32A, 10KA
110.1) Supplying and fixing of Triple Pole & Neutral 63A, 10KA
110.2) Supply and fixing of 8 way SP DB of 16A / way with 16A DP switch with metal clad of 500V with fuse and neutral (side handle) on suitable TW board with PWD earthing
112.1) Supplying and fixing of Exhaust Fan 225mm dia
114) Supplying and delivery of following PVC Aluminium armoured LTUG cable a) 3.5 core 70 Sqmm PVC Aluminium armoured LTUG cable
b) 4 core 10 Sqmm PVC Aluminium armoured LTUG cable
c) 2 core 10 Sqmm PVC Aluminium armoured LTUG cable
115) Labour charges for laying of PVC Aluminium armoured LTUG cable below ground level (Excluding civil works)
116) Labour charges for laying of PVC Aluminium armoured LTUG cable above ground level
117) Supplying and fixing of Brass cable Gland suitable for PVC Aluminium armoured LTUG cable a) 3.5 core 70 Sqmm brass cable gland
b) 4 core 10 Sqmm brass cable gland
c) 2 core 10 Sqmm brass cable gland
117.1) Supplying and fixing of PVC cable end Termination (Crimping Lugs) suitable for following PVC Aluminium Armoured LTUG cable a) PVC cable end Termination (Crimping Lugs) for 3.5 core 70 Sqmm. Aluminium Armoured LTUG cable
b) PVC cable end Termination (Crimping Lugs) for 4 core 10 Sqmm. Aluminium Armoured LTUG cable
c) PVC cable end Termination (Crimping Lugs) for 2 core 10 Sqmm. Aluminium Armoured LTUG cable
119) Supplying and delivery of 2 HP clear water vertical wet type submersible pumpset three phase suitable for borewell
119.1) Supplying and delivery of 2 HP open well submersible pumpset Duty - 50 lpm x 60 m
120) Labour charges for erection of submersible pumpset in borewell / openwell upto 5 HP
121.1) Supplying and fixing of three phase panel board of direct online starter with two level guard and auto start (2 HP submersible pumpset)
122) Supplying and fixing of following dia of the UPVC, GI & GM specials a) 50mm dia UPVC Coupler
b) 50mm dia UPVC Elbow
c) 50mm dia UPVC Tee
d) 50 x 40 mm dia UPVC Reducer Tee
e) 50 mm dia GI Union
f) 50 mm dia GI Hex Nipple
g) 50 mm dia GI Bend
h) 50mm dia GM Non-Return valve
i) 32mm dia GM Gate valve (Heavy Duty)
j) 20mm dia GM Gate valve (Heavy duty)
k) 25 mm dia GI Hex Nipple
123) Supplying and Delivery of PVC insulated and sheathed 3 core 4 sq.mm flat type copper cable for submersible pumpset
124) Supplying and delivery of following dia GI pipes 'B' class in position a) 50mm dia GI pipe
124.1) Labour charges for laying of 50mm dia GI pipes Below Ground level
126.1) Supplying and fixing of following dia M.S. Clamp set a) 200 mm dia MS clamp set
127) Supplying and delivery of required dia Nylon rope for tieing of submersible motor pump
128) Supplying of 40mm dia Cast Iron Adopter
129) Supplying and fixing in position of Aluminium die casting TNPHC Logo emblem a) 60 cm size
130) Supplying and fixing of Aluminium Powder coated letters and Numbers a) Aluminium letters (Tamil) 12" size
b) Aluminium letter 9" size
130.1) Supplying and fixing of Plastic name board of required size
132) Drilling of 150mm dia borewell in hard rock areas
132.1) Charges for developing the Borewell with Air compressor of 600 CFM capacity (Minimum 8 Hrs)
133) Supplying and fixing of following dia PVC casing pipe as per IS 12818/2010 a) 200mm dia PVC Casing Pipe
134) Supplying and fixing of 200mm dia PVC end cap suitable for covering the casing pipe
134.1) Supplying and delivery of following dia UPVC pipes below Ground level a) 50mm dia UPVC pipe
b) 32mm dia UPVC pipe
134.2) Supplying of following dia UPVC column pipe for Borewell a) 40mm dia UPVC column pipe
134.3) Supplying and laying of PVC conduit pipe 25mm (1”) dia Heavy Gauge
139) Supplying and delivery of Godrej Navtal 7 levers – 3 keys lock
140) Supplying of 3 to 10mm size HBS jelly etc.,
142) Supplying of Rubber Moulded Hydraulic pressed Paver block 83mm thick
142.1) Delivery of 83mm thick Paver block including labour charges for loading and unloading charges for conveyance
143) Labour charges for spreading and levelling of 3mm to 10mm size HBSJ and stone dust to the required thickness and compaction by the earth rammer and laying Paver block including Machienry charges
153) Supplying and fixing of MS angle of size 50X50x5mm to hold LTUG cable in Over Head portion
154) Supplying and fixing of TNEB Meter Board suitable for 3 Phase 100A service connection
155) Supplying and fixing of 100 Amps (Triple pole) TPN double break switch with HRC fuse and neutral
162) Supplying and fixing of 120W LED Street light fitting
162.1) Supply and fixing of 60 watts LED Street lighting fitting
164) Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase 304L Grade
255.1) Providing and fixing in position of Perforated sheet 10mm thick Hiluxboard false ceiling
255.2) Providing Gypboard cornice work for false ceiling
344.2) Supplying and fixing of Bevelled Edge Mirror of size 500x400x5.5mm
361.1) Supplying and laying of Concrete designer tiles flooring in C.M. 1:3 (one of cement and three of crushed stone sand) 20mm thick
367) Providing wooden melamine polish for main door new wood work
373) Supplying and installation of Air conditioner with copper coil 2 TR split type AC unit 3 star rated
374.1) Supplying and laying of 5/8" and 3/8" Copper pipe (Extra beyond 3 metres supplied with AC unit) in position
374.2) Supply and fixing of MS stand for fixing outdoor unit
375) Supplying and installation of 5 KVA capacity automatic voltage stabilizer with time delay relay arrangements
378.2) Supplying and fixing of Vitrified tiles (Ivory) in CM 1:3, 20mm tk using crushed stone sand
379.6) Supplying and fixing of Granite slab Jet Black for flooring (Super fine Polished with machine cut edges) of sizes 4'x2' and above 18mm to 20mm thick
448.2) Providing Tee with end cap 32mm dia instead of PVC Bottle trap
DG set arrangements 516) Supply, installation, testing and commissioning of 82.5 KVA generator set
517) Insulation for the residential silencer (Supply of residential silencer to be included under item for DG sets)
518) Supply and installation of M.S. cable adopter box (made of 14 SWG sheet steel) with suitable copper bus extension link from alternator
519) Supply and installation of MS exhaust pipe of suitable thickness with 100mm dia upto 5m from the silencer
520) Supply and installation of MS exhaust pipe of suitable thickness with 125mm dia complete wih MS wall / ceiling support etc.,
521) Supply and insulation of exhaust pipe thermal insulation lagging with mineral wool
522) Supply and installation of stainless steel rain hood / rain cap / bend at top of the exhaust pipe to prevent rain water
523) Preparation of necessary drawings for both Diesel Generator sets for approval
524) Providing safety equipments : CO2 fire extinguisher, 1 No, 9 lit capacity fire buckets - 3 Nos. and rubber mat - 1 No.
Cabling and End Termination 525) Supply and laying of XLPE, aluminium conductor 1.1 KV grade armoured, MV cable of the following size in the existing cable trays / trenches as required generally confirming to IS 1554/Part-I/1970 a) 3.5 core x 185 Sqmm Aluminium cable
526) Supply and fixing of brass cable suitable gland for XLPE armoured Aluminium LTUG cable for following size with earth connection a) 3.5 core x 185 Sqmm Aluminium cable
527) Supply and providing cable end termination for following size of XLPE armoured Aluminium LTUG cable with necessary Aluminium cable sockets by crimping etc., a) Cable end termination for 3.5 core x 185 Sqmm Aluminium cable
528) Earthing as per the ISI speciication with an earth electrode of 2.1 mt class 'B' GI pipe of dia not less than 40mm with copper flat of size 125mmx50mmx6mm with necessary funnelling arrangements
529) Plate earthing as per the ISI specification with an earth electrode of 2.10m class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 600x600x3mm
530) Supply and run of 2 of No. 8 tin coated copper for earth connections
531) Supply and run off 25mmx3mm tinned copper flat with necessary clamps / supports on wall / Floor / ground for earth connection
Fire Fighting arrangements 533) Supply and installation of 12 zone automatic fire alarm panel with fire and fault indications
534) Supply and installation of photo Electric smoke detectors with base and LED to operate on 24 V DC supply etc.,
535) Supply and installation of heat detector to operate on 24 V DC supply make system sensor WL secutron
536) Supply and installation of Electronic hooter 5 watts capacity wall mounting type
537) Supply and installation of manual call point with hammer and chain
538) Supply and installation of 2x1.5 Sqmm copper cable, in casing capping 1%" PVC conduict junction boxes, glands, clamp etc.,
539) Supply and installation of responsible indicator for smoke decuctor inside rooms
540) Supply and installation of ABC type fire Extinguishers, cylindrical in shape wall mounting type with initial charges and discharge nozzle capacity 6 Kg with ISI marked
541) Supply and installation of CO2 type fire Extinguishers, wall mounting type cylindrical in shape with discharge horn capacity 4.5 Kgs
545) Supplying and fixing of wall cladding using Granite tiles 2'x1', 10mm tk (Ruby Red / Raw silk)
552) Supply and erection of 250 Amps capcity floor mounting / wall mounting Panel board (cubical type) with bus bar chamber
563.1) Supplying and fixing of 7 segments (3 Tier) 3 phase Distribution board with MCB
563.2) Supply and run of 25mm x 6mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection
566.1) Supply and fixing of Manhole cover SFRC for the size of 750mm x 750mm
796) Two coat of Exterior emulsion paint including primer for outer wall surfaces
796.1) Two coat of Plastic emulsion paint including primer for inner wall surfaces
marimuthu gounder and co
ASR CONSTRUCTIONS
A VELANI
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_344627.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .