Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹70.1 Cr
EMD Value
₹70.1 L
Closing Date
18 Dec 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
NBCC Bhawan
NBCC Bhawan
Construction of Permanent Campus for JNV, East Delhi , Delhi (U.T. of Delhi) at JNV Jaffarpur Delhi
NBCC/CPG/JNV/EastDelhi/2024/436~EW44e2a686400ec09ab64d0cd3
NBCC/CPG/JNV/EastDelhi/2024/436
Open Tender-Domestic
Civil Works General
NBCC Bhawan
₹1.2 L
₹70.1 L
18 Dec 2024
5 Nov 2024
18 Dec 2024
5 Nov 2024
18 Dec 2024
Sl. No. DSR-2023 DESCRIPTION DSR AMOUNT NON DSR AMOUNT
1 SUB 2.0 EARTH WORKS 11124480.09 0.00
2 SUB 4.0 CONCRETE WORKS 12045613.71 0.00
3 SUB 5.0 REINFORCED CEMENT CONCRETE WORK 241,549,694.75 0.00
5 SUB 8.0 CLADDING WORK 27,318,067.22 0.00
6 SUB 9.0 WOOD AND P.V.C. WORK 10,128,520.76 0.00
8 SUB 11.0 FLOORING WORK 51,282,281.89 0.00
12 SUB 21.0 ALUMINIUM WORK 8,379,785.68 0.00
13 SUB 22.0 WATER PROOFING 1,262,468.44 0.00
14 SUB 26.1 NEW TECHNOLGIES 3,295,192.52 0.00
15 B1 INTERNAL PLUMBING, SANITARY 15,635,427.39 14,423,060.87
16 B2 INTERNAL ELECTRICAL WORK 40,697,238.12 16,353,632.29
18 B6 FIRE FIGHTING 5,891,995 3,355,073
1 TOTAL BUILDING WORKS 561,765,450.58 53,560,826.48
2 DEVELOPMENT WORKS / EXTERNAL SERVICES
2b BITUMINOUS ROAD 3,095,138.52 0.00
2c HORTICULTURE WORKS 702,186.08 0.00
2d DISMANTLING OF BADMINTON COURT 50,784.45 0.00
2e CONSTRUCTION OF OPEN AMPHITHEATER 8,176,940.05 0.00
2f OPEN GYM WITH 16 NOS OF EQUIPMENTS 440,166.82 1,538,170.60
2g MINI INTERGRATED SPORTS COMPLEX 4,809,610.91 1,959,490.21
2h EXTERNAL ELECTRICAL
MAIN LT PANEL 1,467,235.14
CAPACITOR PANEL 395,602.05
FEEDER PANEL 2,151,944.09
HT/LT PANEL CABLES 2,116,202.92 5,588,001.79
EARTHING 368,142.62 0.00
EXTERNAL LIGHTNING 1,601,614.31
11 KV HT STRUCTURE 286,471.15
TRANSFORMER 2,319,725.61
LT PANELS 4,578,055.83
2i EXTERNAL PLUMBING
EXTERNAL WATER SUPPLY 1,398,351.89 30,575.86
EXTERNAL SEWARAGE SYSTEM 2,363,591.45 444,887.13
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
RAIN WATER HARVESTING SYSTEM 1,533,471.98 0.00
DRILLING OF BOREWELL 300 DIA INCLUDING SUBMERSIBLE
PUMP 5 HP AND CABLING 262,814.01 239,999.78
UNDERGROUND TANK 2.00 LTR CAPACITY WITH PUMP HOUSE
AND SUBMERSIBLE PUMP 15 HP 4,341,855.25 675,800.00
SEPTIC TANK 04 NOS FOR 1744 USERS 3,952,256.74
2 TOTAL DEVELOPMENT WORKS 35,050,697.24 26,319,610.75
3 BOUNDARY WALL ALONG WITH GATE
BOUNDARY WALL WITH 1.80 MTRS HEIGHT MASONRY WORK
3a WITH MM DIA CONCERTINA COIL ON TOP 8,748,605.94 0.00
MAIN ENTRY GATE ALONG WITH SENTRY BOOTH/GUARD
3 TOTAL BOUNDARY WALL ALONG WITH GATE 10,086,794.95 152,900.00
4 FURNITURE WORKS
4a SCHOOL BUILDING FURNITURES 7,851,720.00
4b KITCHEN & DINNING HALL FURNITURES 6,392,000.00
4 TOTAL FURNITURE WORKS 0.00 14,243,720.00
TOTAL PROJECT COST 606,902,942.77 94,277,057.24
GRAND TOTAL OF DSR AND NDSR 701,180,000.00
GRAND TOTAL OF DSR AND NDSR 701,180,000.00
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
SH-1 EARTH WORK
Earth work in Excavation by mechanical means (Hydraulic
excavator)/manualmeans over areas (exceeding 30 cm in depth,
1.5 m in width as well as 10sqm on plan) including getting out
and disposal of excavated earth lead upto 50 m and lift upto 1.5
1 2.6 m, as directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches,
plinth, sides of foundations etc. in layers not exceeding 20cm in
depth, consolidating each deposited layer by ramming and
3 2.25 watering, lead up to 50 m and for all lift. Cum 196 190.708 8624.72 1644802.99
Excavating, supplying and filling of local earth (including royalty)
by mechanical transport upto a lead of 5km also including
ramming and watering of the earth in layers not exceeding 20 cm
4 2.25(a) in trenches, plinth, sides of foundation etc. complete. for all lift Cum 700.50 681.5865 5215.91 3555096.57
Extra for every additional lift of 1.5 m or part thereof in
5 2.26 excavation / banking excavated or stacked materials.
Clearing grass and removal of the rubbish up to a distance of 50
7 2.32 m outside the periphery of the area cleared. Sqm 8.95 8.70835 8788.19 76530.63
Supplying chemical emulsion in sealed containers including
8 2.34 delivery as specified.
9 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% ltr 234.75 228.41175 3297.9 753281.91
Diluting and injecting chemical emulsion for
POST-CONSTRUCTIONAL anti-termite treatment (excluding the
10 2.35 cost of chemical emulsion) :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Treatment of soil under existing floors using chemical emulsion @
one litre per hole, 300 mm apart including drilling 12 mm
diameter holes and plugging with cement mortar 1 :2
11 2.35.3 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos E.C. 20% with 1%
TOTAL EARTH WORK 11124480.09 0.00
B 4 CONCRETE WORKS
Providing and laying in position cement concrete of specified
grade excluding the cost of centering and shuttering - All work up
13 4.1 to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
sources : 8 graded stone aggregate 40 mm nominal size derived Cum 6812 6628.076 1496.59 9919488.76
14 4.1.8 from natural sources)
Providing and laying damp-proof course 40mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from
natural sources : 4 graded stone aggregate 12.5mm nominal size
15 4.1 derived from natural sources)
Extra for providing and mixing water proofing material in cement
concrete work in doses by weight of cement as per Per 50 kg 18.15 17.65995
16 4.12 manufacturer's specification.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Making plinth protection 50mm thick of cement concrete 1:3:6 (1
cement : 3 coarse sand (zone-III) derived from natural sources : 6
graded stone aggregate 20 mm nominal size derived from natural
sources) over 75mm thick bed of dry brick ballast 40 mm nominal Sqm 749.3 729.0689 1798.7973 1311447.17
size, well rammed and consolidated and grouted with fine sand,
including necessary excavation, levelling & dressing & finishing
17 4.17 the top smooth.
Providing & applying a coat of residual petroleum bitumen of
grade of VG-10 of approved quality using 1.7kg per square metre
on damp proof course after cleaning the surface with brushes and
18 4.13 finally with apiece of cloth lightly soaked in kerosene oil.
TOTAL (Carried Over to Summary of Civil Works) 12045613.71 0.00
C 5 REINFORCED CEMENT CONCRETE WORK
Centering and shuttering including strutting, propping etc. and
19 5.9 removal of form for :
20 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 392.15 381.56195 1854.584 707638.69
Walls (any thickness) including attached pilasters,
21 5.9.2 butteresses,plinth and string courses etc. Sqm 842.5 819.7525 0.00
Suspended floors, roofs, landings, balconies and access platform.
23 5.9.4 Shelves (Cast in situ) Sqm 927.25 902.21425 0.00
24 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 736.4 716.5172 13748.9462 9851356.43
25 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 961.3 935.3449 10503.42 9824320.33
26 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 764.95 744.29635 682 507610.11
27 5.9.16 Edges of slabs and breaks in floors and walls
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Extra for additional height in centering, shuttering where ever
required with adequate bracing, propping etc., including cost of
de-shuttering and decentering at all levels, over a height of 3.5 m,
for every additional height of 1 metre or part thereof (Plan area
29 5.11 to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
31 5.22 upto plinth level.
32 5.22.6 Thermo-Mechanically Treated bars. kg 107.85 104.93805 347127.95 36426929.68
Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
33 5.22A Above plinth level.
34 5.22A-6 Thermo-Mechanically Treated bars. kg 107.85 104.93805 696767.24 73117395.39
Providing and Laying in position ready mixied or site batched
design mix cement concrete for reinforced cement concrete work
: using Coarse aggregate and fine aggreagate is derived from
natural sources, portland pozzolana /ordinary portland /Portland
salg cement, admixtures in recomended proportion as per IS;
9103 to accelerate / retard setting of Concrete, to improve
durability and workabilty without impairing Strength : Inculding
pupming of concrete to site of laying, Curing carriage of all lead
but excluding the cost of centring and shuttring finishing and
reinforcment as per Direction of EIC for following grade of
35 5.33 Conctrete
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Note Extra Cement up to 10% of the minimun specified cement
content in design mix shall be Payable separetaly. in case the
cement content indesign mix is more than110% of the specified
minimum cement content, the contractor shall have the
discreation to either Re design the mix or bear the cost of Extra
37 5.33.1 All works upto plinth level.
38 5.33.1.1 Concrete M-25 Grade with Minimum cement content 330kg/cum Cum 9504.75 9248.12175 3043.05 28142514.00
39 5.33.2 All works above plinth level upto floor V level.
40 5.33.2.1 Concrete M-25 Grade with Minimum cement content 330kg/cum Cum 9860.4 9594.1692 5906.825845 56671086.59
Add for using extra cement in the items of design mix over and
41 5.35 above the specified cement content therein. Quintal 733.5 713.6955 2953.46 2107870.85
TOTAL (Carried Over to Summary of Civil Works) 241549694.75 0.00
D 6 BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of
42 6.1 class designation 7.5 in foundation and plinth in:
43 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 7132.25 6939.67925 454.00 3150622.93
Providing and laying autoclaved aerated cement blocks masonry
with 100 mm thick AAC blocks in super structure above plinth
level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse
sand ). The rate includes providing and placing in position 2 Nos 6
44 6.38 mm dia M.S. bars at every third course of masonry work. sqm 10195.45 9920.17285 760.97 7548978.96
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and laying autoclaved aerated cement blocks masonry
with 150mm/230mm/300 mm thick AAC blocks in super structure
above plinth level up to floor V level with RCC band at sill level
and lintel level with approved block laying polymer modified
adhesive mortar all complete as per direction of
Engineer-in-Charge. (The payment of RCC band and
45 6.47 reinforcement shall be made for seperately). Cum 8333.65 8108.64145 3884.198 31495565.12
TOTAL (Carried Over to Summary of Civil Works) 42195167.01 0.00
SH-8 MARBLE & GRANITE WORK
Providing and fixing 18 mm thick gang saw cut, mirror
polished,premoulded and prepolished, machine cut for kitchen
platforms, vanity counters, window sills, facias and similar
locations of required size,approved shade, colour and texture laid
over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement,mixed with matching
pigment, epoxy touch ups, including rubbing, curing,moulding
and polishing to edges to give high gloss finish etc. completeat all
46 46 levels.
47 47 Granite stone slab colour black, Cherry/Ruby red
8.3 Providing edge moulding to 18 mm thick marble stone counters,
Vanities etc., including machine polishing to edge to give high
gloss finish etc.complete as per design approved by
49 Engineer-in-Charge.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Extra for fixing marble /granite stone, over and above
corresponding basic item, in facia and drops of width upto 150
mm with epoxy resin based adhesive, including cleaning etc.
8.5 Extra for providing opening of required size & shape for wash
basins / kitchens sink in kitchen platform, vanity counters and
similar location in marble / Granite /stone work including
necessary holes for pillar taps etc. including moulding, rubbing
52 and polishing of cut edges etc. complete. Nos 978.7 952.2751 245.000 233307.40
Stone tile (polished) work for wall lining over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry
53 8.9 @ 3.3 kg/sqm including pointing in white cement complete sqm 3617.55 3519.87615 6926.50615 24380443.80
54 8.9.1 8 mm thick
55 8.9.1.2 Granite of any colour and shade
TOTAL (Carried Over to Summary of Civil Works) 27318067.22 0.00
E 9 WOOD AND P.V.C. WORK
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing fire resistant door frame of section 50 x 60
mm on horizontal side & 35 x 60 mm on vertical sides having built
in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not
less than 120gm/sqm) suitable for mounting 120 minutes Fire
Rated Glazed Door Shutters. The frame shall be filled with mineral
wool Insulation having density minimum 96Kg/sqm . The frame
will have a provision of G.I. anchor fastners 14 nos ( 5 each on
vertical style & 4 on horizontal style of size M10 x 80 ) suitable for
fixing in the opening along with factory made template for SS ball
bearing hinges of Size 100x89x3mm for fixing of fire rated glazed
shutter. The frame shall be finished with a approved fire resistant
primer or powder coating of not less than 30 micron in desired
shade as per the directions of Engineer - in- Charge . (Cost of SS
9.161 ball bearing hinges is excluded). Rmt 2202.9 2143.4217 47.52 101855.40
Providing and fixing 60 mm thick glazed fire resistant door
shutters of 120 minutes Fire rating conforming to IS:3614 (Part II)
or EN1634-1:1999, tested and certified as per laboratory
approved by Engineer-in-Charge, with suitable mounting on door
frame, consisting of vertical styles, top rail & side rail 60 mm x 60
mm wide and bottom rail of 110 mm x 60 mm made out of
1.6mm thick G.I. sheet (zinc coating not less than 120gm/sqm)
duly filled mineral wool insulation having density minimum 96
kg/cum and fixing with necessary stainless steel ball bearing
hinges of size 100x89x3mm of approved make, including applying
a coat of approved fire resistant primer or powder coating not
less than 30 micron etc all complete as per direction of
9.162 Engineer-in-Charge (panelling to be paid for seperately). Sqm 12017.9 11693.4167 31.104 363712.03
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing glazing in fire resistant door shutters, fixed
panels & partitions etc., with
G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not
less than 120 gm/sqm) of
size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance
75 mm from the edges and
150 mm c/c , including applying a coat of approved fire resistant
primer/powder coating of not
less than 30 micron on G.I. beading, & special ceramic tape of 5 x
20 mm size etc complete
in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per
direction of Engineer-in-
Charge with glass of required thickness having 120 minutes of fire
resistance both integrity
& radiation control (EW120) and minimum 20 minutes of
insulation (EI20). The manufacturer
have to give test report/certification of fire glass and the glass
should have the stamp showing
the value of E, EW & EI. The glass shall be tested in approved
NABL accredited lab or by any
other accreditation body which operates in accordance with
ISO/IEC 17011 and accredited
labs as per ISO/IEC 17025 for testing and calibration scopes shall
be eligible. The maximum
glazing size shall not be more than 1100x2200 mm (w x h) or 2.42
Providing and fixing panic bar / latch (Double point) fitted with a
single body, Trim Latch &
Lock on back side of the Panic Latch of reputed brand and
manufacture to be approved by the
9.139 Engineer- in- charge, all complete Nos 8366.15 8140.26395 6 48841.58
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing pressed steel door frames conforming to IS:
4351, manufactured from commercial mild steel sheet of 1.60
mm thickness, including hinges, jamb, lock jamb, bead and if
required angle threshold of mild steel angle of section 50x25 mm,
or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed
together by mechanical means, including M.S. pressed butt
hinges 2.5 mm thick with mortar guards, lock strike-plate and
shock absorbers as specified and applying a coat of approved
steel primer after pre-treatment of the surface as directed by
56 10.14 Engineer-in-charge:
58 Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing ISI marked flush door shutters conforming to
IS : 2202 (Part I) non-decorative type, core of block board
construction with frame of 1st class hard wood and well matched
commercial 3 ply veneering with vertical grains or cross bands
59 9.21 and face veneers on both faces of shutters:
35 mm thick including ISI marked Stainless Steel butt hinges with
61 9.122 Providing and fixing to existing door frames.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door
shutter in different plain and wood finish made with fire retardant
grade unsaturated polyester resin, moulded to 3 mm thick FRP
laminate all around, with suitable wooden blocks inside at
required places for fixing of fittings and polyurethane foam
(PUF)/Polystyrene foam to be used as filler material throughout
the hollow panel, casted monolithically with testing parameters
of F.R.P. laminate conforming to table - 3 of IS: 14856, complete
62 9.122.2 as per direction of Engineer-in-charge. sqm 4489.95 4368.72135
9.23 Extra for providing lipping with 2nd class teak wood battens 25
mm minimum depth on all edges of flush door shutters (over all
63 area of door shutter to be measured). Sqm 462.35 449.86655 1369.136 615928.51
9.40.1 Providing and fixing wooden moulded beading to door and
window frames with iron screws, plugs and priming coat on
64 unexposed surface etc. complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing
to frame with 10 mm diameter bolts, nuts and wooden plugs and
embedding in cement concrete block 30x10x15cm 1:3:6 mix (1
cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal
Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868), transparent or dyed to required colour or shade, with nuts
67 9.96 and screws etc. complete :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
69 9.97 screws etc. complete :
9.1 Providing and fixing aluminium handles, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade, with necessary
71 screws etc. complete :
9.101 Providing and fixing aluminium hanging floor door stopper, ISI
marked, anodised (anodic coating not less than grade AC 10 as
per IS : 1868) transparent or dyed to required colour and shade,
73 with necessary screws etc. complete.
74 9.101.1 Single rubber stopper Each 39.6 38.5308 847.000 32635.59
Providing and fixing casement handle made of zinc alloyed (white
powder coated) for uPVC casement window with necessary
Providing and fixing zinc alloyed (white powder coated) touch
lock for uPVC sliding window with necessary screws etc.
TOTAL (Carried Over to Summary of Civil Works) 10128520.76 0.00
F 10 STEEL WORK
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Structural steel work riveted, bolted or welded in built up
sections, trusses and framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel
Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
79 10.25 approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and
Steel work in built up tubular (round, square or rectangular
hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc.
81 10.16 complete.
82 10.16.1 Hot finished welded type tubes Kg 194.4 189.1512 0 0.00
Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing
and making curvature (wherever required) and fitting the same
with necessary stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories & stainless steel dash
fasteners , stainless steel bolts etc., of required size, on the top of
the floor or the side of waist slab with suitable arrangement as
per approval of Engineer-incharge,
(for payment purpose only weight of stainless steel members
shall be considered excluding fixing accessories such as nuts,
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Fencing with angle iron post placed at required distance
embedded in cement concrete blocks,
every 15th post, last but one end post and corner post shall be
strutted on both sides and
end post on one side only and provided with horizontal lines and
two diagonals interwoven
with horizontal wires, of barbed wire weighing 9.38 kg per 100 m
(minimum), between the two
posts fitted and fixed with G.I. staples, turn buckles etc. complete.
(Cost of posts, struts, earth
work and concrete work to be paid for separately). Payment to be
made per metre cost of total
84 16.18 length of barbed wire used.
Supplying at site Angle iron post & strut of required size including
bottom to be split and bent
at right angle in opposite direction for 10 cm length and drilling
holes upto 10 mm dia. etc.
Supplying and fixing rolling shutters of approved make, made of
required size M.S. laths, interlocked together through their entire
length and jointed together at the end by end locks, mounted on
specially designed pipe shaft with brackets, side guides and
arrangements for inside and outside locking with push and pull
operation complete, including the cost of providing and fixing
necessary 27.5 cm long wire springs manufactured from high
tensile steel wire of adequate strength conforming to IS: 4454 -
part 1 and M.S. top cover of required thickness for rolling
87 10.6 shutters.
88 10.6.2 80x1.20 mm M.S. laths with 1.20 mm thick top cover Sqm 3307.05 3217.75965 10.50 33786.48
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
89 10.7 Providing and fixing ball bearing for rolling shutters. Nos 492.35 479.05655 2.00 958.11
Providing & fixing fly proof wire gauze to windows, clerestory
windows & doors with M.S. Flat 15x3 mm and nuts & bolts
90 10.29 complete
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4
TOTAL (Carried Over to Summary of Civil Works) 48454479.90 0.00
G 11 FLOORING WORK
52 mm thick cement concrete flooring with concrete hardener
topping, under layer 40 mm thick cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and top layer 12 mm thick cement hardener
consisting of mix 1:2 (1 cement hardener mix : 2 graded stone
aggregate 6 mm nominal size) by volume, hardening compound
mixed @ 2 litre per 50 kg of cement or as per manufacturer's
specifications. This includes cost of cement slurry, but excluding
92 11.4 the cost of nosing of steps etc. complete. Sqm 978.45 952.03185 2075.60 1976037.31
Chequered terrazo tiles 22 mm thick with graded marble chips of
size up to 6 mm in floors, jointed with neat cement slurry mixed
with pigment to match the shade of the tiles, including rubbing
and polishing complete, on 20 mm thick bed of cement mortar
93 11.19 1:4 (1 cement :4 coarse sand) :
94 11.19.1 Light shade pigment using white cement Sqm 1533.8 1492.3874 140.87 210232.61
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear
portions of the building all complete as per the architectural
drawings with 18 mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and
jointed with cement slurry and pointing with white cement slurry
admixed with pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified and as directed
95 11.55 by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite
96 11.55.1 Brown, Cat Eye or equivalent Sqm 3186.7 3100.6591 2719.00 8430699.84
Providing and laying Polished Granite stone flooring in required
design and patterns, in linear as well as curvilinear portions of the
building all complete as per the architectural drawings with 18
mm thick stone slab over 20 mm (average) thick base of cement
mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with
cement slurry and pointing with white
cement slurry admixed with pigment of matching shade
including rubbing , curing and polishing etc. all complete as
97 11.56 specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab of all colour and texture except Black,
Extra for pre finished nosing to treads of steps of marble / granite
Extra for marble / granite stone flooring in treads of steps and
100 11.25 risers using single length up to 2.00 metre. Sqm 851.8 828.8014
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Kota stone slab flooring over 20 mm (average) thick base laid over
and jointed with grey cement slurry mixed with pigment to match
the shade of the slab, including rubbing and polishing complete
101 11.26 with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1
cement: 3 coarse sand) and jointed with grey cement slurry mixed
with pigment to match the shade of the slabs, including rubbing
Providing and laying rectified Glazed Ceramic floor tiles of size
300x300 mm or more (thickness to be specified by the
manufacturer), of 1st quality conforming to IS : 15622, of
approved make, in colours White, Ivory, Grey, Fume Red Brown,
laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse
sand), jointing with grey cement slurry @ 3.3 kg/ sqm including
grouting the joints with white cement and matching pigments
Providing and fixing 10 mm thick acid and/or alkali resistant tiles
of approved make and colour using acid and/or alkali resisting
mortar bedding, and joints filled with acid and/or alkali resisting
cement as per IS : 4457, complete as per the direction of
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof
106 11.21.1 cement : 4 coarse sand)
107 11.21.1.1 Acid and alkali resistant tile
In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and laying Vitrified tiles in floor in different sizes
(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS:15622, of
approved brand & manufacturer, in all colours and shade, laid on
20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)
jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The
tiles must be cut with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch trowel, plier, wedge,
clips of required thickness, leveling system and rubber mallet for
109 11.41A placing the tiles gently and easily Sqm 1502.75 1462.17575 1616.92 2364226.55
110 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
111 11.41A.1.1 Size of Tile 600x600mm
112 11.41A.1 Double charge vitrified tile polished finish of size Sqm 1453.65 1414.40145 796.65 1126784.97
113 11.41A.1.1 Size of Tile 600 x 600 mm
Grouting the joints of flooring/wall tiles having joints of 3 mm
width, using epoxy grout mix of 0.70 kg of organic coated filler of
desired shade (0.10 kg of hardener and 0.20 kg of resin per kg),
including filling /grouting and finishing complete as per direction
114 11.48 of Engineer-in-charge.
Providing and laying Vitrified tiles in different sizes (thickness to
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joint
116 11.46 with white cement & matching pigments etc. complete. Sqm 1623.05 1579.22765 119.53 188757.18
117 11.46.2 Size of Tile 600x600 mm
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
TOTAL (Carried Over to Summary of Civil Works) 51282281.89 0.00
H 12 ROOFING WORK
Painting top of roofs with bitumen of approved quality @ 17kg
per 10 sqm impregnated with a coat of coarse sand at 60 cudm
per 10 sqm, including cleaning the slab surface with brushes and
finally with a piece of cloth lightly soaked in kerosene oil
118 12.15.1 complete :
119 12.15.1 With residual type petroleum bitumen of grade VG -10 Sqm 133.15 129.55495 4451.43 576705.17
12.21 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 stone aggregate 10 mm and down gauge),
including finishing with cement mortar 1:3 (1 cement : 3 fine
120 sand) as per standard design :
12.22 Making khurras 45x45 cm with average minimum thickness of
5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1
m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
122 edges and making and finishing the outlet complete. Nos 298.25 290.19725 8.00 2321.58
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Supply & fixing of Galvalume profile sheet of 1072
mm Supply width and nominal 28.5 mm deep ribs with subtle
square fluting in the five pans at nominal 203 mm centre-to-
centre. The end rib shall be designed for anti-capillary action, to
avoid any seepage of water through the lateral overlap. The feed
material is manufactured out of nominal 0.55 mm Base Metal
Thickness (BMT) with +/-0.05 mm Thickness tolerance, Hi-Tensile
steel with min. 550 MPa yield strength, metallic hot dip coated
with Aluminum-Zinc alloy (55% Aluminum, 45% Zinc) as per AS
1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides)
with Super durable Polyester Colorbond XRW quality paint coat as
per AS/NZS 2728 Class 3 of BlueScope Steel make. The paint will
have a total coating thickness of nominal 35 μm, comprising of
nominal 20 μm exterior coat on top surface and nominal 5 μm
reverse coat on back surface over nominal 5 μm primer coat on
both surfaces of approved colour shade by concern authority. The
exposed paint system’s shall have higher SRI value (Thermatech
technology) and use inorganic (lead free) pigment in paint
system.The sheet shall have brand marking of the manufacturer
giving product details on the back of the sheet at every regular
123 M.R interval for confirming genuinity of the material. Sqm 972.42 8425.44 8193023.94
Providing and fixing Flashings/Trims/Gutter of same material as
124 M.R above Girth upto 610 mm RMTR 697.56 872.28 608466.2341
GI Metal Ceiling Lay in perforated Tegular edge global white color
tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop;
made of GI sheet having galvanizing of 100 gms/sqm (both sides
inclusive) and 20% perforation area with 1.8 mm dia holes and
having NRC (Noise Reduction Coefficient) of 0.5, electro statically
polyester powder coated of thickness 60 microns (minimum),
including factory painted after bending and perforation, and
125 12.52.1 backed with a black Glass fiber acoustical fleece. Sqm 1902.95 1851.57035 5077.86 9402007.43
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
TOTAL (Carried Over to Summary of Civil Works) 9981034.17 8801490.18
I 13 FINISHING WORK
126 13.4 12 mm cement plaster of mix :
128 13.16.1 6mm cement Ceilling plaster of mix :-
18 mm cement plaster in two coats under layer 12 mm thick
cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top
130 13.11 layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). Sqm 518.55 504.54915 8672.66 4375782.50
Providing and applying plaster of paris putty of 2mm thickness
over plastered surface to prepare the surface even and smooth
Finishing walls with Premium Acrylic Smooth waterproofing
exterior paint with Silicone additives of required shade having
antifungal properties on external walls two or more coats as per
manufacturer's specification. including priming coat of exterior
Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
Wall painting with premium acrylic emulsion paint of interior
grade, having VOC (Volatile Organic Compound ) content less
than 50 grams/ litre of approved brand and manufacture,
including applying additional coats wherever required to achieve
134 13.83 even shade and colour.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Distempering with oil bound washable distemper of approved
136 13.41 and manufacture to give an even shade :
New work (two or more coats) over and including water
137 13.41.1 thinnable priming coat with cement primer Sqm 185.65 180.63745
Painting with synthetic enamel paint of approved brand and
138 13.62 manufacture of required colour to give an even shade :
Two or more coats on new work over an under coat of suitable
139 13.62.1 shade with ordinary paint of approved brand and manufacture Sqm 226.25 220.14125 4596.70 1011922.84
Providing & fixing Clay Exterior Wall Cladding Tiles of Length :-
230mm, width :- 75mm, 15 thick with back side groove of
1.75mm (Dimensional Tolerance ± 2mm) Made from unglazed
fired clay, fired at more than 1100 degree Celsius for minimal
porosity and high strength. in Smooth finish face with completely
natural and matt appearance. All natural shades i.e. Terracotta,
Brown, Chocolate and Beige. or as per approved fixed on 12mm
140 M.R cement mortar of 1:3 ratio Sqm 3013.00 2241.78 6754479.75
TOTAL (Carried Over to Summary of Civil Works) 32394110.86 8847688.83
ALUMINIUM WORKS
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap beading
for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be
141 21.1 paid for separately) :
142 For fixed portion
Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade AC
For shutters of doors, windows & ventilators including providing
and fixing hinges/ pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
144 21.1.2 gasket required (Fittings shall be paid for separately)
Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade AC
Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket
etc. complete as per the architectural drawings and the directions
of engineer-in-charge . (Cost of aluminium snap beading shall be
146 21.3 paid in basic item):
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
With float glass panes of 8 mm thickness (weight not less than 20
Filling the gap in between aluminium frame & adjacent RCC/
Brick/ Stone work by providing weather silicon sealant over
backer rod of approved quality as per architectural drawings and
148 21.8 direction of Engineer-in-charge complete.
TOTAL (Carried Over to Summary of Civil Works) 8379785.68 0.00
M 22 WATER PROOFING
Providing and laying water proofing treatment in sunken portion
of WCs, bathroom etc., by applying cement slurry mixed with
150 22.5 water proofing cement compound consisting of applying
First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be
151 a) allowed to air cure for 4 hours
Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This layer will
be allowed to air cure for 4 hours followed with water curing for
TOTAL (Carried Over to Summary of Civil Works) 1262468.44 0
26 New Technologies
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Project :- Construction Of Permanent campus for JNV, East Delhi jaffarpur kalan
BOQ - CIVIL WORKS Amount
Items Ref. DSR 2023 Rate
Sl. No. DESCRIPTION UNIT correction Total Qty DSR Amount NDSR Amount
(DSR-2023) / MR
Providing and fixing factory made single extruded WPC solid
Decorative type Flushdoor shutter of Required size comprising of
virgin polymer of K value 58 -60 (suspension grade) , Calcium
carbonate and natural fiberand Non Toxic additiveshaving
Minimum density of 65 kg/cum and screw withdrawal strength of
1800N (Face) & 900N (Edge) , minimum compresive strength 50
n/mm2 , modulusof elasticity 850 N/mm2 and Resistance to
spread of Flame of Class A Category with Propertyof being
termite/borerproof , water/moisture proof and fire Retardent .
WPC to be Laminatewith PVC foil of Minimum 14 micron thick of
approved design pasted with hot melt adesive on Both Face
153 26.88 Shutter and fixing Stainless steel Butt Hinges required Size
TOTAL (Carried Over to Summary of Civil Works) 3295192.518 0
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SUMMARY INTERNAL PLUMBING
S. No. Description DSR Amount MR Amount
1 SANITARY FIXTURES & FITTINGS 7847500.66 8970132.88
2 WATER SUPPLY (INTERNAL) 6636950.54 573157.49
3 INTERNAL DRAINAGE (SOIL, WASTE, VENT, RAIN WATER PIPES & FITTING 1150976.20 4879770.50
GRAND TOTAL 30,058,488.26
GRAND TOTAL 30,058,488.26
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
A. SANITARY FIXTURES & FITTINGS
Providing and fixing white vitreous china extended wall
mounting water closet of size 780x370x690 mm of
approved shape including providing & fixing white vitreous
china cistern with dual flush fitting, of flushing capacity 3
litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat
cover, and cistern fittings, nuts, bolts and gasket etc
Providing and fixing water closet squatting pan (Indian
type W.C. pan ) with 100 mm sand cast Iron P or S trap, IO
litre low level white P.V.C. flushing cistem, including flush
pipe, with manually controlled device (handle lever)
forming to IS : 7231, with all fittings and fixtures complete,
including tting and making good the walls and floors
3 17.10 wherever required:
White Vitreous china Orissa pattem W.C. pan of size
17.1.1 580x440 mm with integral type foot rests Each 6767.40 6584.68 116 763822.90
Providing and fixing white vitreous china wash basin
including making all connections but excluding the cost of
6 17.25 fittings :
17.25.1 Flat back wash basin of size 630x450 mm Each 1339.70 1303.53 261 340220.83
Providing and fixing white vitreous china laboratory sink
with C.I. brackets, C.P. brass chain with rubber plug, 40 mm
C.P brass waste and 40mm C.P. brass trap with necessary
C.P. brass unions complete, including painting of fittings and
brackets, cutting and making good the wall wherever
8 17.11 required :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing of 15 mm dia C.P. brass Pillar cock
with CP wall flange of approved quality with flow rate of 5
9 MR-01 LPM complying to Green Building requirements. Each 1677.83 267 447979.33
Providing and fixing first quality C.P. brass Long Body Bib
cock of 15 mm nominal bore, with CP wall flange of
approved quality with flow rate of 5 LPM complying to
10 MR-02 Green Building requirements. Each 1901.52 283 538131.34
Providing and fixing white vitreous china flat back half stall
Providing and fixing first quality C.P. brass Pressmatic
Urinal flush Valve of approved quality with flow rate of 1
12 MR-03 LPM complying to Green Building requirements. Each 3169.62 58 183837.82
Providing and fixing Urinal Division Plate with table
rubbed, edges rounded and polished, of size 900 x 450 mm,
fixed in urinal partitions by cutting a chase of appropriate
width with chase cutter and embedding the stone in the
chase with epoxy grout or with cement concrete 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 6 mm
nominal size) as per direction of Engineer-in-charge and
13 MR-04 finished smooth. Each 5329.79 47 250500.30
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen
sink as per IS:13983 with C.I. brackets and stainless steel
plug 40 mm, including painting of fittings and brackets,
14 17.1 cutting and making good the walls wherever required :
17.10.1 Kitchen sink with drain board
Providing and fixing C.P brass Sink mixer swivel spout (Wall
mounted) of approved make complete as required with
flow rate of 5 LPM complying to Green Building
15 MR-05 requirements. Each 5215.06 58 302473.76
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible
tube upto 1 metre long with S.S. triangular plate to
Eureopean type W.C. of quality and make as approved by
Providing and fixing of vitreous China Sanitary fixtures and
CP fitting and other accessories for Handicapped toilet .
Each Matrix Set shall comprised (Wash Basin 650 x 350
with one pair mounting brackets, EWC & Cistern complete
with fittings & seat cover, one no hinged rail 76 cm and five
MR-06 no's of grab rails 60 cm). complete all respect. Each 16388.83 6 98332.97
Providing and fixing of 1 No. Swing Handicap Grab Bar -
Stainless Steel at fixed height for handicap toilet complete
18 MR-07 as required. Each 12127.36 6 72764.18
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing of 1 No. Stainless Steel Grab Barl (600
Mm),32mm Dia. at fixed height for handicap toilet complete
19 MR-08 as required. Each 5107.41 6 30644.46
Providing and fixing of 1 No. Stainless Steel Grab Bar (350
Mm),32mm Dia. at fixed height for handicap toilet complete
20 MR-09 as required. Each 3159.83 6 18958.98
Providing and fixing of 15 mm dia CP brass bib cock with
CP wall flange of approved quality with flow rate of 5 LPM
21 MR-10 complying to Green Building requirements. Each 1497.47 358 536093.52
22 17.34 Providing and fixing toilet paper holder.
Providing and fixing of C.P. brass twin coat hook with PVC
23 MR-11 rawl plug & C.P. brass screw complete as required. Each 1037.49 170 176372.78
Providing and fixing C.P. brass angle valve for basin mixer
and geyser points of approved quality conforming to
Providing and fixing uplasticised PVC connection pipe with
25 18.21 brass unions.
18.21.2 15 mm nominal bore
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing & fixing chrome plated brass battery based
18.84 infrared operated pillar cock, having foam flow technology.
Providing and fixing C.P. brass shower rose with 15 or 20 mm
26 18.22 inlet
Providing and fixing of CP Brass Bath and Shower Mixer with
provision of overhead shower with 115mm long bend pipe, in
built spout, spout / shower selector with wall flange complete
with all accessories as required and making good the walls
wherever required. with flow rate of 5.0 LPM complying to
27 MR-12 Green Building requirements. Each 5847.01 206 1204484.98
Providing and fixing PTMT liquid soap container 109 mm
wide, 125 mm high and 112 mm distance from wall of
standard shape with bracket of the same materials with
snap fittings of approved quality and colour, weighing not
Providing and fixing PTMT soap Dish Holder having length
of 138mm, breadth 102mm, height of 75mm with
concealed fitting arrangements, weighing not less than 106
Providing and fixing PTMT towel ring trapezoidal shape
215 mm long, 200 mm wide with minimum distances of 37
mm from wall face with concealed fittings arrangement of
30 17.72 approved quality and colour, weighing not less than 88 gms. Each 231.95 225.69 261 58904.40
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing 600x450 mm beveled edge mirror of
superior glass (of approved quality) complete with 6 mm
thick hard board ground fixed to wooden cleats with C.P.
31 17.31 brass screws and washers complete Each 1607.95 1564.54 262 409908.26
Providing and fixing PTMT towel rail complete with
brackets fixed to wooden cleats with CP brass screws with
concealed fittings arrangement of approved quality and
32 17.73 colour.
450 mm long towel rail with total length of 495 mm, 78 mm
wide and effective height of 88 mm, weighing not less than
Providing and fixing CP Brass 32mm size Bottle Trap of
approved quality & make and as per the direction of
33 17.22A Engineer-in-charge. Each 1034.80 1006.86 334 336291.37
Supply of solid state, no touch operating, fully hygienic hand
drier of approved shade with single blower, with time delay,
summer & winter control, music while drying, volume ON/OFF
MR-13 controls complete as required. Each 10209.14 69 704430.94
Providing, Fixing,testing and commissioning drinking
water water coolar with in built RO facility including angle
valve and flexible connection piping of the following
capacity. It shall have C.P brass push cock complete with
inlet float valve (with angle valve) with all plumbing and
electrical accessories, inlet, outlet, overflow and PVC drain
out connection to F.D complete as required. (Storage
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing of Storage type water heater/ Geyser
with required accessories like 15 mm CP angle valve on
inlet & outlet line, heavy duty reinforced flexible PVC
connector for cold water line and flexible CP brass
connector with CP checkout for hot water line, CPVC line
connection, MS bracket with two coats of enamel paint,
anchor fastners etc. to hang the units, providing and fixing
of 16 A 3 Pin plug of Anchor make, etc. complete as
a MR-15 Capacity 15 Liters Each 12846.00 85 1091909.61
MR-16 Capacity 25 Liters Each 16597.15 43 713677.33
B. WATER SUPPLY (INTERNAL)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, i/c fixing
the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent
cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of
1 18.8 Engineer in Charge.
Concealed work, including cutting chases and making
good the walls etc.
1.2 18.8.2 20 mm nominal outer dia Pipes Metre 537.60 523.08 2221 1161771.34
1.3 18.8.3 25 mm nominal outer dia Pipes Metre 627.25 610.31 924 563930.37
1.4 18.8.4 32 mm nominal outer dia Pipes Metre 739.30 719.34 959 689846.01
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent
cement and testing of joints complete as per direction of
2 18.7 Engineer in Charge.
Internal work - Exposed on wall
2.6 DSR _RA 65 mm dia nominal bore Metre 1165.00 1133.55 220 249379.90
Providing and fixing ball valve (brass) of approved quality,
4 18.18 High or low pressure, with plastic floats complete :
4.4 MR-17 32mm nominal bore Each 1006.73 96 96645.92
MR-18 40mm nominal bore Each 1112.99 66 73457.03
Providing and fixing gun metal gate valve with C.I. wheel of
5 18.17 approved quality (screwed end) :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing in position of approved quality high
pressure rated Gun Metal Float Valve with copper ball float
and brass rods of required length suitable for test pressure
7 of not less than 15 Kg/sqcm of the following sizes:
7.1 MR-19 20 mm dia nominal bore Each 1243.48 3 3730.4
7.2 MR-20 25mm nominal bore Each 3025.61 12 36307.3
7.3 MR-21 32mm nominal bore Each 3431.07 25 85776.6
7.4 MR-22 40mm nominal bore Each 4123.13 24 98955.2
DSR-2022 Providing and fixing in position the industrial type pressure
/16.8 gauges with gun metal/ brass valves complete as required Each 1196.00 1163.71
Water Level Indicator with Musical Alarm on Tank Full and Buzze
MR-23 Empty with 20 metres of Sensor Wire Each 1423.37 61 86825.4
Providing & fixing Auto Air vent for cold water supply
8 risers, suitable for pressure not less than 15 Kg/Sq.cm.
Supplying, fixing, testing and commissioning of butterfly valve
of PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
18.11 13095 of following sizes as required :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing C.I. dirt box strainer for bulk type water
meter with nutsi bolts, rubber insertions etc. complete
18.61 conforming to IS : 2373 :
Providing and placing on terrace (at all floor levels)
polyethylene water storage tank, IS : 12701 marked, with
cover and suitable locking arrangement and making
necessary holes for inlet, outlet and overflow pipes but
9 18.48 without fittings and the base support for tank. per liter 11.00 10.70 107820 1153997.46
C. INTERNAL DRAINAGE (SOIL, WASTE, VENT, RAIN WATER PIPES & FITTINGS)
Providing, jointing, testing and fixing UPVC Soil, Waste &
Vent system conforming to IS : 13592 (Type-B) and UPVC
fittings (moulded as well as fabricated) like bends, tees,
Y-tees, crosses, boss connections, access pieces, saddle
pieces, cleanouts, adaptors for connections to other
materials, plugs, reducers, cowls, offset and other specials.
Jointing shall be done with push fit EPDM ring jointing
technique in general. Solvent cement joints may be
provided for fittings and specials which are not
manufactured with push fit rubber joints. Fixing at
wall/ceiling level supported by galvanized steel clamps &
hangers etc. Making proper connection and also pipes may
be laid / fixed in sunken floors, under slung from ceiling.
The pipes laid in sunken floor shall be encased with not less
than 75 mm thick cement concrete (1:2:4) all around. The
installation shall be complete in all respects including
cutting chases / holes in walls, slabs and making good the
same as per specifications. (All major MS structure to hold
1 the stack is included in this item).
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing, jointing, testing and fixing UPVC Rain water
system conforming to IS : 13592 (Type -A) and UPVC
fittings (moulded as well as fabricated) like bends, tees,
Y-tees, crosses, boss connections, access pieces, saddle
pieces, cleanouts, adaptors for connections to other
materials, plugs, reducers, cowls, offset and other specials.
Jointing shall be done with push fit EPDM ring jointing
technique in general. Solvent cement joints may be
provided for fittings and specials which are not
manufactured with push fit rubber joints. Fixing at
wall/ceiling level supported by galvanized steel clamps &
hangers etc. Making proper connection and also pipes may
be laid / fixed in sunken floors, under slung from ceiling.
The pipes laid in sunken floor shall be encased with not less
than 75 mm thick cement concrete (1:2:4) all around. The
installation shall be complete in all respects including
cutting chases / holes in walls, slabs and making good the
same as per specifications. (All major MS structure to hold
2 the stack is included in this item).
2.1 MR-27 110 mm dia Type A Metre 691.00
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing, fixing, jointing and testing UPVC soil, waste, vent
pipework comprising UPVC pipe conforming to IS
:4985-1983 of class 3 (6kg/cm2) as specified below and
fittings (moulded as well as fabricated) like elbows, bends,
reducers, threaded tail pieces, caps, suitable elbow with
suitable extension piece for drain point and other specials
jointing with cement solvent, chasing, cutting and making
good the walls & floors pipes laid in floors shall be encased
with 40 mm thick concrete all around, complete in all
respects including testing of complete installation.(All
major MS structure to hold the stack with fixing including
3 anchor fasteners, sand, cement etc is included in this item)
3.1 MR-29 40 mm od 6 kg/cm2 (Class III ) Metre 387.02 826.5 319868.6
Providing and fixing UPVC/SWR trap (P trap) of self
cleaning design as per IS:13592 : 1992 complete including
cost of cutting and making good the cutouts in walls and
floors etc.including cutting and making good the walls and
4 floors wherever required complete.
4.1 MR-30 110 mm inlet and 110 mm outlet Nos. 858.53 325 279021.5
Providing and fixing floor drain made out of 110x63 mm
OD uPVC elbow connected to uPVC pipe complete as per
5 MR-31 direction of Project Manager. Nos. 810.99 362 293579.0
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Providing and fixing Inlet Fitting for Urinal trap, formed out
of 110 mm PVC pipe with multiple side inlets formed with
saddle pieces, suitable for 40, 50 and 63 mm dia side
connections as per standard detail and support through
galvanized steel support from slab or set in cement
concrete mix 1:2:4 including cutting and making good the
6 MR-32 walls and floors wherever required. Nos. 910.26 52 47333.4
Providing and fixing Heavy Class SS grating of approved
design including setting in floor with cement motor to
match with floor finish as per architect requirement
7 suitable for waster and FT, UT & FD.
Providing and fixing P.V.C. WC connector (straight or bend
type) with rubber lip ring. Including 110 mm dia PVC pipe /
bend of required length and proper connection with M seal
8 MR-34 to C.I. pipe complete as required. Nos. 896.28 190 170292.6
Providing and fixing M.S. holder bat clamps of approved
design to C.I. or S.C.I. rain water pipes embedded in and
including cement concrete blocks 10x10x10 cm of 1:2:4 mix
(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and cost of cutting holes and making good the
10 12.38 walls etc. :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ - INTERNAL PLUMBING
DSR / DSR Rate with DSR NDSR
S.N NDSR ITEM UNIT DSR 2023 Rate QUANTITY
/ MR correction factor AMOUNT AMOUNT'
PART-B PLUMBING WORKS
Making khurras 45x45 cm with average minimum thickness
of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate of 20 mm nominal size) over P.V .C.
sheet 1 m x1 m x 400 micron, finished with 12 mm cement
12.22 plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat
cement, rounding the edges and making and finishing the
outlet complete.
Constructing brick masonry catch basin
chamber30x30x77.5 cm with bricks in cement mortar 1:4
(1 cement : 4 coarse sand) including 500x450 mm pre-cast
R.C.C. horizontal grating with frame complete as per
standard design :
With common burnt clay F.P.S. (non modular) bricks of class
MR-35 designation 7.5 each 6262.34 38.00 237968.87
Providing and fixing 15 Cm wide, 45 cm overall
semi-circular plain G.S. sheet with iron
brackets 40x3mm size, bolts, nuts and washers etc.,
including making necessary connections
12.7 With rain water pipes complete.
12.7.1 0.80 mm thick with zinc coatin not less than 275 m/m2 Metre 1029.65 1001.85 1086.00 1088008.50
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SUMMARY OF INTERNAL ELECTRICAL WORK
S. No. Description of item
Schedule Item DSR - 2022 Market Rate
A MAIN DISTRIBUTION BOARDS 2253600.73 409690.31
C HOT DEEP GI CABLE TRAYS & GI RACEWAYS 1141973.16 0.00
D EARTHING 725297.88 0.00
E. LIGHITNG ARRESTOR 1521388.68 0.00
F INTERNAL WIRING: 34793683.46 0.00
G LIGHTING FIXTURE AND FANS 0.00 11507822.85
TOTAL COST FOR DSR + MR 57050870.40
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
1.0 DISTRIBUTION BOARDS
Supplying and fixing following way, single pole and
neutral, sheet steel, MCB distribution board, 240 V, on
surface/ recess, complete
with tinned copper bus bar. neutral bus bar, earth bar.
din bar. interconnections, powder painted including
earthing etc. as required. (But without
MCBIRCCB/lsolator)
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution
board of sheet steel, dust protected, duly powder
painted, inclusive Of 200 A tinned copper bus bar,
common neutral link. earth bar, din bar for mounting
MCBs (but without MCBs and incomer ) as required .
(Note : Vertical type MCB TPDB is normally used where 3
phase outlets are required.)
Supplying and fixing following way, horizontal type three
pole and neutral, sheet steel, MCB distribution board, 415
V, on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar, interconnections,
powder painted including earthing etc. as required. (But
without MCB/RCCB/Isolator)
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
Supplying and fixing 5 amps to 32 amps rating, 240 volts,
'C' series, miniature circuit breaker suitable for inductive
DSR-2.10 load of following poles in the existing MCB DB complete
with connections, testing and commissioning etc. as
DSR-2.10.3 Double pole Each 49 599 637 620 30,366
Supplying and fixing single pole blanking plate in the
existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single
phase and neutral), 240 V, residual current circuit
DSR-2.14 breaker (RCCB), having a sensitivity current 30 mA in the
existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying, fixing, connecting, testing and commissioning
of following rating, ISI marked (IS 8828) 240 / 415 volts, 10
KA, Miniature Circuit Breaker (MCB) of single / double /
three / four poles in the existing MCB DB or in existing MS
enclosure complete in all respects.
TOTAL CARRIED TO SUMMARY 2,253,601 409,690
Supply of XLPE insulated and PVC sheathed
Aluminium/Copper conductor armoured cable of 1.1 KV grade
confirming to IS : 7098:1988 with upto date amendments of
following sizes:-
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
MR - 2 4 core, 16 Sq.mm. Copper cable Mtr 2675 0 1,530 4,091,746
MR - 3 3.5 core, 25 Sq.mm. Aluminium cable Mtr 535 0 644 344,373
Laying and fixing of following sizes of one number PVC
DSR-7.8 insulated and PVC sheathed/XLPE Power cable of 1.1kv
grade on cable tray as required.
DSR-7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Mtr 3210 45 48 47 149,447 0
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1
KV grade as required.
TOTAL CARRIED TO SUMMARY 261,294 4,436,119
HOT DEEP GI CABLE TRAYS & GI RACEWAYS
Supplying and installing following size of perforated Hot
Dipped Galvanised Iron cable tray (galvanisation
thickness not less than 50 microns) with perforation not
more than 17.5%, in convenient sections, joined with
connectors, suspended from the ceiling with G.I.
suspenders including G.I. bolts & nuts, etc. as required.
DSR-4.6.1 100 mm width X 50 mm depth X 1.6 mm thickness Metre 920 669 711 692 636,770 0
DSR-4.6.2 150 mm width X 50 mm depth X 1.6 mm thickness Metre 682 716 761 741 505,203 0
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
TOTAL CARRIED TO SUMMARY 1,141,973 0
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm
thick including accessories, and providing masonry
DSR-5.4 enclosure with cover plate having locking arrangement Each 34 7,472 7,945 7,730 262,836 0
and watering pipe of 2.7 metre long etc. with charcoal/
coke and salt as required.
Providing & fixing of 25mm x 5mm GI strip on surface or
recess for earth connection as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in
recess for loop earthing as required.
TOTAL CARRIED TO SUMMARY 725,298 0
LIGHTNING ARRESTOR
Providing and fixing of lightning conductor finial, made
of 25 mm dia 300 mm long, G.I. tube, having single prong
at top, with 85 mm dia 6 mm thick G.I. base plate
including holes etc. complete as required
Providing and fixing G.I. tape 20 mm X 3 mm thick on
DSR-6.7 parapet or on surface of wall for lightning conductor Meter 2200 126 134 130 286,789
complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on
DSR-6.8 parapet or on surface of wall for lightning conductor Meter 1450 197 209 204 295,531
complete as required. (For vertical run)
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
Providing and fixing testing joint, made of 20 mm X 3 mm
thick G.I. strip, 125 mm long, with 4 Nos. of G.I. bolts, nuts,
chuck nuts and spring washers etc. complete as
Providing and laying G.I. tape 32 mm X 6 mm from earth
electrode directly in ground as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm
thick including accessories, and providing masonry
DSR-5.4 enclosure with cover plate having locking arrangement Nos 64 7472 7,945 7,730 494,750
and watering pipe of 2.7 metre long etc. with charcoal/
coke and salt as required.
TOTAL CARRIED TO SUMMARY 1,521,389 0
INTERNAL WIRING:
Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable in surface / recessed steel
conduit, with modular switch, modular plate, suitable GI
box and earthing the point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable etc. as
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without
independent switch etc.) with 1.5 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
recessed steel conduit, and earthing the point with 1.5
sq. mm FRLS PVC insulated copper conductor single core
cable etc. as required.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC
insulated copper conductor single core cable in surface/
DSR-1.5 recessed steel conduit alongwith 1 No. 4 sq. mm FRLS meter 10690 433 460 448 4,788,883 0
PVC insulated copper conductor single core cable for
loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire
with the following sizes of FRLS PVC insulated copper
conductor, single core cable in surface/ recessed steel
conduit as required.
DSR-1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire meter 10690 428 455 443 4,733,584
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess, including
providng and fixing 2 Nos. 3 pin 5/6 A modular socket
outlet and 2 Nos. 5/ 6 A modular switch, connections etc.
as required. (For light plugs to be used in non residential
Supplying and fixing suitable size GI box with modular
plate and cover in front on surface or in recess, including
DSR-1.32 providing and fixing 6 pin 5/6 A & 15/16 A modular Each 957 586 623 606 580,201 0
socket outlet and 15/16 A modular switch, connections
etc. as required.
Supplying and fixing two module stepped type
electronic fan regulator on the existing modular plate
switch box including connections but excluding modular
plate etc. as required.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
Supplying and fixing modular blanking plate on the
DSR-1.26 existing modular plate & switch box excluding modular Each 75 40 43 41 3,104 0
plate as required.
Providing and fixing circular/hexagonal Fan box cast iron
/metal sheet Box for ceiling fan clamp of internal dia
140mm , 73 mm height,Top id of 1.5mm thick MS sheet
with its Top surface hacked of proper bonding top lid
shall be screwed into cast iron /metal sheet Box by mean
of 3.3mm dia round headed screw one lock at the
corners.clamp shall be made of 12mm dia ms Bar band
toshape as per standrd drawing.
Supplying and fixing 20 A, 240 V, SPN Industrial type
socket outlet, with 2 pole and earth, metal enclosed plug
top alongwith 20 A "C" curve, SP, MCB, in sheet steel
enclosure, on surface or in recess, with chained metal
cover for the socket outlet and complete with
connections, testing and commissioning etc. as required.
TOTAL CARRIED TO SUMMARY 34,793,683 0
LIGHTING FIXTURE AND FANS
Supply, Installation, testing and commissioning of
following type Fluorescent/ Compact fluorescent/LED
light fixtures on wall/ Ceiling including all fixing
accessories such as leads, etc complete as required. The
Fluorescent /CFL fixtures shall be complete with Low loss
copper ballast PF improvement capacitor, Bipin Rotor
type lamp holder, starter, starter base, all pre wired upto
the terminal block. All fixtures shall be supplied with
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
SITC of 18W LED light with die cast aluminium housing
MR - 4 with inbuilt controller and robust consction complete as Nos 852 0 2,660 2,266,347
SITC of Surface/Wall mounted 12W LED light with die cast
MR - 5 aluminium housing with inbuilt controller and robust Nos 441 0 1,637 721,882
consction complete as required.
SITC of 9w LED Bulkhead with a nominal system lumen
output of 600 lumens and a minimum system efficacy of
100 lm/W. The luminaire shall have a rated system lifetime
of 50,000 burning hours at L70. The luminaire should have
a color temperature of 6500K and CRI > 70. The luminaire
shall meet IP66 rating and IK 09 rating with THD < 20% and
PF > 0.9. The luminaire housing should made of High
pressure die cast Aluminium with polycarbonate front
diffuser. The total power consumption should not exceed
6W (including driver).
SITC of of 9W LED (mirror light) 2ft Batten with a nominal
system lumen output of 1150 lumens and a minimum
system efficacy of 115 lm/W. The luminaire shall have a
rated system lifetime of 25,000 burning hours at L70. The
MR - 7 luminaire should have a color temperature of 6500K and Nos 248 0 778 192,849
CRI>80. The luminaire shall meet IP20 rating with THD <
20% and PF > 0.9. The luminaire housing should made of
CRCA with a PC glossy diffuser. The total power
consumption should not exceed 10W (including driver).
SITC of Surface or wall mounted 20W & 2000Lumens LED
MR - 8 Tube Rod with extruded aluminium housing with inbuilt Nos 801 0 1,160 928,835
controller and robust consction complete as required.
SITC of Surface or wall mounted 20W & 2000Lumens LED
MR - 9 Light with extruded aluminium housing with inbuilt Nos 1174 0 617 723,853
controller and robust consction complete as required.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ INTERNAL ELECTRICAL
Sl. No. Description Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount
SITC of ceiling fans complete with blades, down rods,
electronic regulator and accessories, 230 V, 1200mm
MR - 10 sweep. Min air delivery 210 CFM with service value 6.00 Nos 764 0 6,364 4,861,842
BEE. Five star rated with brushless direct current motor
SITC of exhaust fan, steel body AC single Phase. 230V of
size 300m sweep with, blades, and frame and louvers
SITC of Surface/Recessed type 36W LED light with die
MR - 12 cast aluminium housing with inbuilt controller and robust Nos 218 0 3,614 787,842
consction complete as required.
SITC of Surface/Wall Mounted Spot Focus light 36W LED
MR - 13 light with die cast aluminium housing with inbuilt Nos 17 0 2,101 35,712
controller and robust consction complete as required.
SITC of Wall fan 400 mm
TOTAL CARRIED TO SUMMARY 0 11,507,823
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Sub Head Description of item DSR 2022 Market Rate
A TELEPHONE SYSTEM 729797.07
B LAN NET-WORKING SYSTEM 567326.02
C CCTV (IP VIDEO SURVEILLANCE) SYSTEM 129892.89 482758.23
TOTAL COST FOR DSR + MR 1909774.21
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Description DSR rate with
Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount REMARKS
TELEPHONE SYSTEM
S.I.T.C. telephone point wiring with 2 pair
telephone wires of minimum 0.61mm.
diameter annealed copper wire, PVC
insulated, PVC sheathed in 25 mm
diameter concealed
PVC conduit system complete with all
sheet steel terminal box and socket to
1 accept RJ-11 plugs as follows
Telephone point wiring with 2 pair
telephone wires for Each 26
one no. telephone socket out let.
Telephone tag block as per ITI design for
termination of specified number of pairs
housed in suitable sized Sheetsteel Box
with hinged cover duly painted tag box
making the connections as follows
Telephone wires Mtr 495
Digital EPABX complete with : Each 1
one Operator Console with 24 Key DSS.
Built-in Charger & battery back-up
(at-least for 4 Hrs.),
facilities such as ISDN, DTMF/DISA,
Conference, MDF,COLA
for PIT protection,
TOTAL CARRIED TO SUMMERY Set 1 729797 729797
LAN NET-WORKING SYSTEM
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Description DSR rate with
Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount REMARKS
S.I.T.C. Network point wiring for computer
local area network (LAN) comprising of
RJ-45 socket connectors connected to a
10 base T network using UTP category 6
cable (CAT 6). The cable shall be laid in
25 mm. diameter concealed /exposed
metallic I PVC conduit system and shall
2 be complete with
Sheet metal switch box & RJ-45
connector-socket at one end and male Each 34
connector at the other end (Hub end)
24 Ports, 10/100Mbps, + 2 Port 1
OOOBase-T Unmanaged . Each 1
Stand-alone Switch.
19" 6U Rack with accessories Each 1
Patch panel Each 1
Cable Manager Each 1
Patch Cord Each 34
Information outlet ( 1/0) Each 34
Wi-Fi Router ( 50 mtr. Range ) Each 1
TOTAL CARRIED TO SUMMERY Set 1 567326 567326
CCTV (IP VIDEO SURVEILLANCE) SYSTEM
CCTV (IP VIDEO SURVEILLANCE) SYSTEM Complete set
and accessories as per required system & technical
Specifications.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Description DSR rate with
Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount REMARKS
Supply, installation, testing and
commissioning of 3 MP Bullet camera ,
ONVIF profile S ,G & T . UL , CE , FCC
Certified ,1/2.8” Progressive Scan CMOS
,2.7 mm to 12 mm motorized varifocal lens
, Quad stream with each stream support
H.265+ compression simultaneously ,min
illumination : 0.01 Lux @ (F1.2,AGC ON), 0
Lux with IR , Shutter speed : 1 / 5s ~ 1 /
100,000 s ,120 dB WDR , Compression : No. 6 8702 52210
support , Alarm trigger - 1 input / 1 output
, frame rate : Main stream should support
25 fps@5MP , Edge analytics : line crossing
, perimeter intrusion ,Face detection
(deep learning) , pedestrian detection
,cross counting , stationary object , In built
IR LED , IR Distance upto 50 meters , IP 67 ,
3 IK 10 housing , POE.
Supply, installation, testing and
commissioning of 3 MP Dome camera ,
ONVIF profile S , G& T ,UL , CE , FCC
Certified ,1/2.8” Progressive Scan CMOS
,2.7 mm to 12 mm motorized varifocal lens
, Quad stream with each stream support
H.265+ compression simultaneously ,min
illumination : 0.01 Lux @ (F1.2,AGC ON), 0
Lux with IR , Shutter speed : 1 / 5s ~ 1 /
100,000 s ,120 dB WDR , Compression : Nos. 6 9013 54079
support upto 128GB , Alarm trigger - 1
input / 1 output , frame rate : Main
stream should support 25 fps@5MP ,Edge
analytics : line crossing , perimeter
intrusion ,Face detection(deep learning) ,
pedestrian detection ,cross counting ,
stationary object , In built IR LED , IR
4 Distance upto 40 meters , IP 67 , IK10 ,POE.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Description DSR rate with
Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount REMARKS
Supply , installation , testing and
commissioning of PTZ Bullet camera in
metal body with continues 360° pan for
both indoor and outdoor with 30x
Minimum & 12x Digital Zoom or
better,Lens 4.3-129 mm or better, Image
Resolution 1920 x 1080 or better in H.264
and Motion JPEG, Day & Night, IP66 and
Edge Storage Built in SD card slot with
support upto 64 GB with Class 10 speed
Autotracking , Mounting brackets are
Supply, installation, testing and
commissioning of 16 channel NVR ,
ONVIF compliant , recording bandwidth
640 Mbps , output interface 1 HDMI (up to
4K), 1 VGA , Alarm in/out :16ch in / 4ch
out , 1 X RJ45 ethernet , iOS smartphone
support , 8 HDD support , each HDD slot
support upto 8 TB HDD , RAID support ,
1x3.0 USB for backup /upgrade , 2x 2.0 Nos. 1 107349 107349
USB for mouse .Edge analytics of poposed
cameras must be integrated with NVR .
Artificial Intelligence Support having face
recognition with compatible deep
learning supported cameras, AI-Face
registered quantity upto 10,000 ,A.I
maximum captured quantity 200,000. .
6 UL,CE,FCC certified.
Supply, installation, testing and
commissioning of user Client control
software (web based) with system
complete as per spec with valid licenses. Set 1 73128 73128
The software should enable the user to
view multiple cameras in any
7 combination available on the network .
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Description DSR rate with
Unit TOTAL QTY. DSR Rate 2022 correction DSR Amount MR Rate MR Amount REMARKS
Supply, Installation, Testing and
Commissioning of Full HD 55" LED Nos. 1 42558 42558
8 Professional Display Panel.
Supply, Installation, Testing &
Commissioning of Surviellance Hard Disk. Nos. 1 15295 15295
9 (15 Days Storage)
10 Joystick controller Nos 1 61802 61802
Supplying and drawing of UTP 4 pair CAT 6
LAN Cable as per EIA in the existing
surface/ recessed Steel/PVC Conduit as
DSR-1.53 required.
Supplying and fixing of followmg smes ot
medium class PVC conduit
along With accessories in surface/recess
including cutting the wall
and making good the same in case of
DSR-1.21 recessed conduit as required.
TOTAL CARRIED TO SUMMERY 129893 482758
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SUMMARY FIRE FIGHTING WORKS
FIRE FIGHTING WORKS
S. No. Description DSR Amount MR Amount
1 SUBHEAD-I: HYDRANT SYSTEM 559473.65 223924.00
2 SUBHEAD-II: PIPING VALVE & ACCESSORI 2861285.28 62280.00
3 SUBHEAD- III : FIRE EXTINGUSHER 0.00 956640.00
4 SUBHEAD-IV: FIRE PUMP 1125107.26 902100.00
5 SUBHEAD-V: FIRE ALARM SYSTEM 1346128.98 1210129.00
GRAND TOTAL 9,247,068.18
GRAND TOTAL 9,247,068.18
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supplying, installation, testing and commissioning of weather
proof M.S cabinet size 900 mm wide x1000 mm height x 600mm
1 MR-1 deep fabricated from 1.6mm thick M.S. sheets and M.S angle
40mmx40mmx6mm complete with glass, locking arrangements
to accommodate the following.
First Aid hose Reel - 1 No.
Pressure Gauge - 1 No.
The cabinet shall be painted with one coat of primer and 2 coats
of synthetic enamel paint of approved shade.
Supplying and fixing single headed internal hydrant valve with
instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia
with cast iron wheel ISI marked conforming to IS 5290 (Type -A)
with blank Gunmetal/Stainless Steel cap and chain as required
DSR- 18.9.1 Single headed Gunmetal Each 7646 8130 7910 20 158209.64
Supplying and fixing first-aid Hose Reel with MS construction
spray painted in post office red, conforming to IS 884 complete
with the following as required. 20 mm nominal internal dia
water hose thermoplastic (Textile reinforced) type -2 as per IS:
12585. 20 mm nominal internal dia gun metal globe valve &
nozzle. Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve &
M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with
4 DSR-18.16 63 mm dia male and female couplings duly bound with GI wire,
rivets etc. conforming to IS 636 (type-A) as required :
Supplying & fixing 63 mm dia gun metal short branch pipe with
20 mm nominal internal diameter size nozzle conforming to IS
903 suitable for instantaneous connection to interconnect hose
pipe coupling as required :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supplying, installation, testing and commissioning of fire brigade
connection of cast iron body with gun metal male & female
6 DSR-18.19 instantaneous inlet couplings complete with cap and chain as Set 6742 7169 6975 5 34876.06
reqd. for suitable dia MS pipe connection conforming to IS 904
DSR-18.19.1 2 way - 100 mm dia M.S. Pipe
Supplying and fixing orifice plate made out of 6 mm thick
stainless steel (Grade 304) with orifice of required size to be
7 DSR-18.13 fitted between flange & landing valve of external and internal Each 1321 1405 1367 23 31433.98
hydrants to reduce pressure at the outlet to the level of 3.5
kg/cm2 complete as required.
Providing and fixing in position the industrial type pressure
gauges with gun metal / brass valves complete as required
Providing and fixing standard fire man's axe with heavily
insulated rubber handle complete as required.
4 buckets set with sand, self-supported M.S. stand i/c shed duly
painted with red colour as per IS.
Sub Total Amount Total 559473.6518 223,924.00
Sub Total Amount Total 559473.6518 223,924.00
SUBHEAD-II: PIPING VALVE & ACCESSORIES
Providing, laying, testing & commissioning of 'C' class heavy duty
MS pipe conforming to IS 3589/IS 1239
including Welding, fittings like elbows, tees, flanges, tapers, nuts
1 DSR-18.7 bolts, gaskets etc. and fixing the pipe on the wall/ceiling with
suitable clamp/support frame and painting with two or more
coats of synthetic enamel paint of required shade complete as
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supplying, fixing, testing and commissioning of butterfly valve
PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete
7 DSR-18.11 with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of
following sizes as
Providing, installation, testing and commissioning Stainless steel
6 DSR-18.15 strainer fabricated out of 1.6 mm thick stainless steel sheet with
3 mm dia holes with stainless steel flange
Providing, installation, testing and commissioning of dual plate
non- return valve of following sizes confirming to IS 5312
complete with rubber gasket, GI bolts, nuts, washers etc. as
Providing, Installation, Testing and Commissioning of 25mm dia
8 MR-4 Gun Metal / Bronze Ball Valves screwed ends of following sizes Each 1,903.00 20 38,060.00
as required. (PN-1.6)
Providing and fixing single acting air valve with screwed inlet 25
Sub Total amount 2861285.285 62280
Sub Total amount 2861285.285 62280
SUBHEAD- III : FIRE EXTINGUSHER
Supply, installation, testing and commissioning fire extinguisher
of carbon dioxide type consisting of brand new high pressure
steel cylinder bearing IS: 7285 mark and having the approval of
controller of explosives Nagpur, wheel type valve bearing
IS:3224 mark internal discharge tube, 1 meter long high
pressure discharge hose, non conducting horn, suspension
bracket, fully charged bearing IS: making fixed to wall as
directed conforming IS : 15683:2006
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Providing and fixing ABC Powder type fire extinguishers
consisting of welded M.S. cylinderical body, squeeze lever
discharge valve fitted with pressure indicating guase internal
2 discharge tube 30 cms long high pressure discharge hose,
discharge nozzle, suspension bracket conforming to IS:15683
finished externally with re enamel paint and fixed to wall with
brackets complete with inernal charge.
Supply, installation, testing and commissioning of ISI marked
(IS:15683:2006) portable chemical fire extinguisher, water (gas
3 pressure) type capacity 9 litres with gun metal cap and nozzle
and complete in all respects including initial fill and wall
suspension brackets as required as per specifications.
Sub Total amount 0 956640
Sub Total amount 0 956640
SUBHEAD-IV: FIRE PUMP
1 TERRACE LEVEL - FIRE PUMP
Supplying, storing, handling, shifting, installation, testing and
commissioning, supervision of testing of electric driven terrace
pump suitable for automatic operation & consisting of , complete
in all respects as required. (Terrace Pump)
B) horizontal type , multistage, centrifigual, split casing pump of
cast iron body & bronze impeller with stainless sheet shaft,
mechanical conforming to IS: 1520
C) Suitable HP Squirell cage induction motor TEFC suitable type
for operation on 415V, 3 phase 50HZ ac supply, with IP : 55 class
of protection of enclosure, horizontal foot mounted type with
class-F insulation , conforming to IS 325
D) MS fabricated common base plate , coupling, coupling guard,
foundation bolt etc. as required.
E) Suitable cement concrete foundation duly plastered and with
anti vibration pads.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supply, installation, testing and commissioning of following cables:
4 Core 4Sqmm, unarmoured ATC copper conductor multistranded,
cable. Mtr 110
Laying of one number additional PVC insulated and PVC
sheathed / XLPE power cable of 11 KV grade of following size
direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc as required.
Fabrication, supply, Insallation testing & commissioning Of
Electrical control panel Of cubical construction, floor mounted
type, fabricated out Of 2mm thick CRCA sheet,
compartmentalised with hinged lockable doors, dust and vermin
proof, powder coated of approved shade after 7 tank treatment
process, cable alley, inter-connection with suitable size copper
conductor cable/solid copper strip, having switchgears and
accessories, mountings and internal wiring, earth terminals,
numbering etc. complete in all respect, suitable for main fire
pump, pressurisation pump & diesel pump set complete as per
CPWD specification with following in coming and Outgoings,
suitable for operation on 415V, 3 phase, 50HzAc Supply with
enclosure protection class IP 42 as required :
63A, 50kA 4 Pole MCCB, lcs=1000/0 lcu rating
Digital Voltmeter 0-500V with selector switch
Digital Ammeter (0-250 A) with selector swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating
Set of Copper Bus Bar 300A
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
25 A, 50kA TPN MCCB, lcu, with fully automatic Star/Delta
starter suitable for 7 HP pump with overload protection, current
sensing type single phase preventor complete with all
acceessories and internal wiring required for automatic
operation, selector switch for local/remote, auto/manual/OFF
MR-10 Total set Set 135500 5 677500
4 buckets set with sand, self-supported M.S. stand i/c shed duly
painted with red colour as per IS.
Providing and fixing resilient rubber neoprene lined single vibration
elimination connection with unit control suitable for raw water upto
45 deg.C. temperature working pressure 20 kg/Sq.Cm.
Sub Total amount 1125107.258 902100
Sub Total amount 1125107.258 902100
SUBHEAD-V: FIRE ALARM SYSTEM
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supplying, installation, testing and commissioning of micro
processor based intelligent addressable main fire alarm panel,
central processing unit with the following loop modules and
capable of supporting not less than 240 devices (including
detectors) and minimum 120 detectors per loop and loop length up
to 2 km, network communication card, minimum 320 character
graphics/ LCD display with touch screen or other keypad and
minimum 4000 events history log in the non volatile memory
(EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up
with 24 volt sealed maintenance free batteries with automatic
charger. The panel Shall have facility to connect printer to printout
log and facility to have seamless integration with analog/digital
voice evacuation system (which is part of the schedule of work
under SH: PA System) and shall be complete with all accessories .
The panel shall be compatible for IBMS system with open protocol
BACnet/ Modbus over IP complete as per specifications,
17.2.1.2 Two Loop Panel. Each 239,225 5 1196125
Supplying, installation, testing & commissioning of intelligent analog
addressable photothermal detector complete with mounting base 2858 3039 2957 181 535191.80
17.2.4 complete as required. Each
Supplying, installation, testing & commissioning of fault isolator
complete with base as required.
Providing and fixing of self illuminated / auto glow
"EXIT" signs printed on photoluminescent sheet containing
self illuminated base chemical, of appropriate size not less
than 400 x 150 mm, suspended from ceiling or fixed to the
walls with accessories as required and as directed at site etc.
MR-14 complete as required. Each
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable,
600/1000V rated with annealed copper conductor having XLPE
insulation, steel wire armouring & FRLS outer sheath complete as
17.5.2 required. Each
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DESCRIPTION UNIT RATE rate with DSR AMOUNT NDSR AMOUNT
No. Item correction
SUBHEAD-I: HYDRANT SYSTEM
Supplying and fixing of following sizes of steel along with
accessories in surface/recess including painting in case of surface
DSR-EL-2022/1. conduit, or cutting the wall and making good the same in case Of
20 recessed conduit as required.
Supplying, installation, testing & commissioning of addressable
17.2.15 horn cum strobe complete as required. Each
Sub Total amount 1346128.98 1210129
Sub Total amount 1346128.98 1210129
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ FOR PATHWAY
Rate DSR Correction
SNo DSR Code Item Unit 2023 factor Qty Amount DSR Amount NDSR
Earth work in surface excavation not exceeding 30 cm in depth but
exceeding 1.5 m in width as well as 10 sqm on plan including
getting out and disposal of excavated earth upto 50 m and lift upto
2.1 1.5 m, as directed by Engineer-in- Charge:
2.25 Filling available excavated earth (excluding rock) in trenches, plinth,
sides of oundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m. Cum 196.00 190.71 0.00 0.00
4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to
4.1.10 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural
sources : 8 graded stone aggregate 40 mm nominal size derived
from natural sources) Cum 6518.60 6342.60 79.97 507217.55
Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size,
design & shape, laid in required colour and pattern over and
including 50mm thick compacted bed of coarse sand, filling the
joints with line sand etc. all complete as per the direction of
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Providing and laying at or near ground level factory made kerb
stone of M-25 grade cement concrete in position to the required
line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints with or without
grooves (thickness of joints except at sharp curve shall not to more
than 5mm), including making drainage opening wherever required
complete etc. as per direction of Engineer-in-charge (length of
finished kerb edging shall be measured for payment). (Precast C.C.
16.69 kerb stone shall be approved by Engineer-in-charge). Cum 10117.60 9844.42 16.30 160464.12
Total Cost 1439183.56 0.00
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
DSR Rate Correction
SNo DSR Code Item Unit 2023 Factor Qty Amount DSR Amount NDSR
Excavating, supplying and filling of local earth (including royalty) by
mechanical transport upto a lead of 5km also including ramming and
watering of the earth in layers not exceeding 20 cm in trenches, plinth,
2.25A sides of foundation etc. complete. Cum 700.5 681.5865 441.34 300811.39
Preparation and consolidation of sub grade with power road roller of 8
to 12 tonne capacity after excavating earth to an average of 22.5 cm
depth, dressing to camber and consolidating with road roller including
making good the undulations etc. and re-rolling the sub grade and
16.1 disposal of surplus earthwith lead upto 50 metres. Sqm 218.9 212.9897 1817.27 387059.79
16.3.1 Supplying and Stacking at Site 90mm to 45 mm size stone agg Cum 2098.4 2041.7432 272.59 556558.78
16.3.2 Supplying and Stacking at Site 63 mm to 45 mm size stone agg Cum 1636.05 1591.87665 181.73 289291.74
Laying, spreading and compacting stone aggregate of specified sizes to
WBM specifications in uniform thickness, hand picking, rolling with 3
wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper
grade and camber, applying and brooming requisite type of screening /
binding material to fill up interstices of coarse aggregate, watering and
16.4 compacting to the required density . Cum 1046.95 1018.68235 318.02 323961.36
16.3 Supplying and stacking at site
16.3.6 Stone screening 13.2 mm nominal size (Type A) Cum 2034.35 1979.42255 90.86 179850.33
16.3.7 Stone screening 11.2 mm nominal size (Type B) Cum 2247.75 2187.06075 27.26 59619.28
2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone
chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52
kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and
11.2 mm size respectively, including a tack coat with hot straight run
bitumen, including consolidation with road roller of 6 to 9 tonne
16.33 capacity etc. complete (tack coat to be paid for separately).
With paving Asphalt grade VG - 10 heated and then mixed with solvent
16.33.1 at the rate of 70 grams per kg of asphalt Sqm 281 273.413 1817.27 496865.24
Brick edging in full brick width and half brick depth including excavation,
16.7 refilling and disposal of surplus earth lead upto 50 metres.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
With common burnt clay F.P.S. (non modular) bricks of class designation
Providing and applying tack coat using hot straight run bitumen of grade
including heating the bitumen, spraying the bitumen with mechanically
spray unit fitted on bitumen boiler, cleaning and preparing the existing
16.3 surface as per specifications : Sqm 60.5 58.8665 1817.27 106976.32
Providing and laying seal coat of premixed fine aggregate ( passing 2.36
mm and retained on 180 micron sieve) with bitumen using 128 kg of
bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60
cum of fine aggregate per 100 sqm of road surface, including rolling and
16.4 finishing with road roller all complete. Sqm 88.55 86.15915 1817.27 156574.44
Total Cost 3095138.52 0.00
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ FOR HORTICULTURE WORKS
DSR Rate Correction
SNo DSR Code Item Unit 2023 Factor Qty Amount DSR AMOUNT NDSR
16.3 Supplying and stacking at site.
2.36 Extra for levelling & neatly dressing of disposed soil completely as directed by
Engineerin- charge Cum 93.05 90.54 564.00 51063.23
2.4 Supplying and stacking at site dump manure from approved source, including
carriage upto 5 km lead complete (manure measured in stacks will be
reduced by 8% for payment) :
2.4.3 Screened through sieve of I.S. designation 4.75 mm cum 287.75 279.98 300.00 83994.23
2.8 Spreading of sludge, dump manure and/or good earth in required thickness
as per direction of officer-in-charge (cost of sludge, dump manure and/ or
good earth to be paid separately). cum 46.15 44.90 300.00 13471.19
2.9 Mixing earth and sludge or manure in the required proportion specified or
directed by the Officer-in-charge cum 32.10 31.23 300.00 9369.99
2.1 Grassing with selection No. 1/ Doob grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick lawn,
free from weeds and fit for mowing including supplying good earth, if needed
(the grass and good earth shall be paid for separately).
2.10.1 In rows 5 cm apart in both directions sqm 15.55 15.13 1640.00 24813.45
2.14 Digging holes in ordinary soil and refilling the same with the excavated earth
mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked
volume of earth after reduction by 20% : 1 part of stacked volume of manure
after reduction by 8%) flooding with water, dressing including removal of
rubbish and surplus earth, if any, with all leads and lifts (cost of manure,
sludge or extra good earth if needed to be paid for separately)
2.14.3 Holes 60 cm dia, and 60 cm deep Each 39.95 38.87 80.00 3109.71
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
2.33 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm
thickness of existing ground prepared with proper level and ramming with
tools wooden (Dhurmos) and than rolling the surface with light roller make
the surface smoothen and light waterning with sprinkler and maintenance for
30 days or more till the grass establish properly, as per direction of
officer-in-charge. Per Sqm 211.25 205.55 160.00 32887.40
4.91 Providing and Displaying Budded Rose (H.T. variety) 3 to 4 healthy branch 30
cm and above ht. well developed with one and above flower plant in 20 cm
Earthen Pot, as per direction of the officer-in-charge. Each 32.80 31.91 60.00 1914.86
4.92 Providing and Displaying Creeper Rose variety 3 to 4 healthy branch 60 cm
and above ht. well developed with one and above flowers in 25 cm Earthen
Pot, as per direction of the officer-in-charge. Each 75.85 73.80 60.00 4428.12
4.93 Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90
cm and above ht. well developed with one and above flowers in 25 cm
Earthen Pot, as per direction of the officer-in-charge. Each 150.70 146.63 80.00 11730.49
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ FOR DISMANTLING OF BADMINTON COURT
DSR Rate Correction
SNo DSR Code Item Unit 2023 Factor Qty Amount DSR AMOUNT NDSR
15.2 Demolishing cement concrete manually/ by mechanical means
including disposal of material
within 50 metres lead as per direction of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum 2434.25 2368.53 5.00 12171.25
15.3 Demolishing R.C.C. work manually/ by mechanical means
including stacking of steel bars
and disposal of unserviceable material within 50 metres lead as
per direction of Engineer - incharge. Cum 3551.25 3455.37 8.00 28410.00
15.5 Extra for cutting reinforcement bars manually/ by mechanical
means in R.C.C. or R.B. work
(Payment shall be made on the cross sectional area of R.C.C. or
R.B. work) as per direction of
Engineer-in-charge. Sqm 1147.2 1116.23 56.00 64243.20
MR Credit of dismantle items reinforcement of badminton courrt Sqm 965 -56.00 -54040.00
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ Open Air AmphiTheater
Sl. DSR- Description of Item Qty. Unit DSR Rate Rate with Amount Amount
No. 2023 2023 Correction (In Rs.) NDSR
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting
out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of oundations etc. in
layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. 415.7 Cum 196.00 190.71 79277.32
3 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering
and shuttering - All work up to plinth level :
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate
40 mm nominal size derived from natural sources) 63.14 Cum 6812.00 6628.08 418496.72
4 5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of
centering, shuttering, finishing and reinforcement - All work up to plinth level :
A 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). 117.16 Cum 9045.75 8801.51 1031185.47
B 5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,
plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth
level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 95.76 Cum 10852.95 10559.92 1011217.97
5 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and
binding all complete upto plinth level.
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 27761 Kg 107.85 104.94 2913185.21
6 5.9 Centering and shuttering including strutting, propping etc. and removal of form for all heights :
A 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete 71.52 Sqm 392.15 381.56 27289.31
B 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 470.86 Sqm 842.50 819.75 385988.66
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
6.2.2 Cement Mortar 1:6 (1 cement : 6 coarse sand). 2.53 Cum 7132.25 6939.68 17557.39
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
6.4 superstructure above plinth level up to floor V level in all shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 89.268 Cum 9105.95 8860.09 790922.46
11.26 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement
slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete
with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 529.57 Sqm 1948.25 1895.65 1003877.91
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average)
thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with
11.27 pigment to match the shade of the slabs, including rubbing and polishing complete 177.203 Sqm 2354.70 2291.12 405993.89
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Abstract of Cost Open Gym
Sl. DSR- Description of Item No Qty. Unit DSR Rate Rate with Amount Amount
No. 2023 2023 Correction (In Rs.) DSR (In Rs.) NDSR
Area =476.25 Sqm 0.973
Surface dressing of the ground including removing vegetation and inequalities
not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8
graded stone aggregate 40 mm nominal size derived from natural sources)
M.R Providing and Fixing Rubber Tile of 600x600 20 mm thick Tile with approved
adhsive as instructed by EIC 1 446.62 Sqm 1740.00 777118.80
Providing, designing and fixing Leg Press Double (250x590x1720) 1 1 Nos 39608.70 39608.70
Providing, designing and fixing Log Cycle (850x550x675) 1 1 Nos 30772.59 30772.59
Providing, designing and fixing Twister Tripple (2074x560x1453) 1 1 Nos 35162.68 35162.68
Providing, designing and fixing of ABS SHAPER DOUBLE /SITUP BENCH DOUBLE
of size 1570mm x1400mmx670mm(Approx) 1 1 Nos 35693.96 35693.96
Providing, designing and fixing of SHOULDER PRESSER SHAPER of size 2188mm
Providing, designing and fixing of AIR SWING WALKER of size 992mm x505mm
Providing, designing and fixing of SHOULDER ARM WHEEL of size 1350mm x
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Providing, designing and fixing of BACK EXTENSION of size 1220mmX 790mm X
Providing, designing and fixing of PARALLEL BARS of size 1600mm X 330mm X
Providing, designing and fixing of HORSE RIDER of size 850mm x 550 mm x 675
Providing & fixing ARM AND PADDLE, BIKE DIMENSIONS:- 1100mm (Length) x
500mm (Width) x 900mm (Height). SAFE AREA:- 2000mm (Length) X1000mm
Providing, designing and fixing of CHEST PRESSER SHAPER of size 1725mm
Providing & fixing SEATED PULLER /PULL CHAIR made from “C” Class G.I pipe.
DIMENSIONS: – 1900mm (Length) x 740mm (Width) x 1920mm. (Height). SAFE
Providing & fixing SKY WALKER DIMENSIONS: – 1720mm (Length) x 630mm
(Width) x 1750mm.(Height) SAFE AREA: – 2.7Mtr x 1.6Mtr. Sky Walker 1 1 Nos 60119.09 60119.09
Providing & fixing CROSS TRAINER / ELLIPTICAL EXERCISER DIMENSIONS: –
1320mm (Length) x 600mm (Width) x 1750mm. (Height). SAFE AREA: – 1.77 x
Providing & fixing SURF BOARD Providing and fixing Surf Board made from “C”
Class GI pipe. 1 1 Nos 60119.09 60119.09
Total of Open Gym 440166.82 1538170.60
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ FOR MINI INTEGRATED SPORTS COMPLEX
Sl. DSR- Description of Item Qty. Unit DSR Rate Rate with Amount Amount
No. 2023 2023 correction (In Rs.) DSR (In Rs.) NDSR
(In Rs.) factor
Preparation and consolidation of sub grade with power road roller of
8 to 12 tonne capacity after excavating earth to an average of 22.5 cm
depth, dressing to camber and consolidating with road roller including
making good the undulations etc. and re-rolling the sub grade and
16.1 disposal of surplus earthwith lead upto 50 metres. 1216 Sqm 218.90 212.99 258995.48
16.3.2 63 mm to 45 mm size stone aggregate 91.2 Cum 1636.05 1591.88 145179.15
16.3.3 53 mm to 22.4 mm size stone aggregate 91.2 Cum 1842.30 1792.56 163481.28
16.3.6 Stone screening 13.2 mm nominal size (Type A) 60.8 Cum 2034.35 1979.42 120348.89
16.3.7 Stone screening 11.2 mm nominal size (Type B) 60.8 Cum 2247.75 2187.06 132973.29
Laying, spreading and compacting stone aggregate of specified sizes
to WBM specifications in uniform thickness, hand picking, rolling with
3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to
proper grade and camber, applying and brooming requisite type of
screening / binding material to fill up interstices of coarse aggregate,
16.4 watering and compacting to the required density . 425.6 Cum 1046.95 1018.68 433551.21
Providing and laying C.C. pavement of mix M-25 with ready mixed
concrete from batching plant. The ready mixed concrete shall be laid
and finished with screed board vibrator , vacuum dewatering process
and finally finished by floating, brooming with wire brush etc.
complete as per specifications and directions of Engineer-in-charge.
16.75 (The panel shuttering work shall be paid for separately).
(Note:- Cement content considered in this item is @ 330 kg/cum.
Excess/less cement used as per design mix is payable/ recoverable
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. 4864 Kg 107.85 104.94 510418.68
M.R 01 Acrylic Flooring consisting of 8 Layers System
1st Layers of Re surface
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
5 Layers of Cushion
2 Layers of Colour
Line Marking as per International Standard 1080 Sqm 953.21 1029469.23
MR 02 Hand Opetrated Hydraulic Movable Basket Ball System with 20 mm
thick Transparent acrylic board with Double die Made Farme
Aluminium anodized with built in bracket for mounting , Dunking Rim,
3.2 mtr Projection from the base Pole Special non marking wheels,
Hand Operated Hydraulic system for East lifiting and bringing down
the backboard in a folded position as shown 1 Pair 730516.89 730516.89
MR 03 Hand Ball Goal Post Poles (3 mtr width 2.0 mtr Ht ) Front Facia of 80
mm Dia of M.S Pipe 3.2m +-1 mm , wall Thickness , with Rear pipes of
40/mm dia with hook for holding nets at rear along with wheels All
Premiered & Painted along with Hand balls net 1 Pair 44200.00 44200.00
MR 04 Volleyball Poles Basic Model with over lapping system for Ht
adjustment volleyball net plastic Coated steel wire net antenna for
Fiber glass 2 Pair 35204.62 70409.25
MR 05 Line Marking for Badminton court onKota stone Flooring as per
International Rules with Paint 1 Pair 25166.13 25166.13
MR 06 Installation Charges 1 Pair 39728.71 39728.71
MR 07 Transporation 1 Pair 20000.00 20000.00
DSR Chain Link Fencing:3 mtr Ht 480
2.6 Earth work in excavation by mechanical means (Hydraulic
excavator)/manual means over areas (exceeding 30 cm in depth, 1.5
m in width as well as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and for all lift, as directed
by Engineer-incharge. 28.80 Cum 177.50 172.71 4974.60
2.6.1 All kinds of soil
4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of
centering and shuttering - All work up to plinth level :
4.1.10 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural
sources : 10 graded stone
aggregate 40 mm nominal size derived from natural sources) 4.85 Cum 6518.60 6342.60 30786.59
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources
: 4 graded stone
aggregate 20 mm nominal size derived from natural sources) 19.47 Cum 7878.50 7665.78 149245.85
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
10.16 Steel work in built up tubular (round, square or rectangular hollow
tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and applying a priming
coat of approved steel
primer, including welding and bolted with special shaped washers etc.
10.16.3 Electric resistance or induction butt welded tubes 4502.43 Kg 194.40 189.15 851639.92
16.71 Providing and fixing G.I. chain link fabric fencing of required width in
mesh size 25x25 mm
made of G.I. wire of dia 3 mm including strengthening with 2 mm dia
wire or nuts, bolts and
washers as required complete as per the direction of
Engineer-in-charge. 480.06 Sqm 1149.25 1118.22 536812.81
13.5 Applying priming coat:
13.50.3 With ready mixed red oxide zinc chromate primer of approved brand
and manufacture on steel
galvanised iron/ steel works 960.12 Sqm 67.40 65.58 62964.86
13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even
13.61.1 Two or more coats on new work 960.12 Sqm 155.90 151.69 145641.27
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SUMMARY OF EXTERNAL ELECTRICAL WORK
S. No. Description of item
Schedule Item DSR - 2022 Non-Schedule Item
A MAIN LT PANEL 1,467,235.14
B CAPACITOR PANEL 395,602.05
C FEEDER PANELS 2,151,944.09
E EARTHING 368,142.62 0.00
F EXTERNAL LIGHTING 1,601,614.31
G 11 KV HT Structure 286,471.15
H TRANSFORMER 2,319,725.61
J LT PANELS 4,578,055.83
GRAND TOTAL 23,915,032.71
GRAND TOTAL 23,915,032.71
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ External Electrical Work
DSR rate with GST DSR rate with
S.No. Description of Items Unit Qty DSR Rate 2022 DSR-Amount NSR Rate NSR-Amount Remarks
factor correction factor
A MAIN LT PANEL
Design, manufacture, supply inspection, instalation, handling, assembling, affecting proper
connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical
type Main L.T. Panel, floor mounting, dust & vermin proof, front operated construction,
enclosure class - IP 52, powder coated after proper treatment with 9 tank process with
top/bottom removable gland plates, as required, double compression type cable glands,
earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all
inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The
Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic
aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable up to
3.5 / 4 core 300 sq mm armoured aluminium cable or Aluminium Bus Duct as required.
All incoming / bus coupler MCCB shall be microprocessor based with O/L & S/C and E/F
protection and all Outgoings MCCB's may be thermo-magnetic based O/L & S/C
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with trip
setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral
The breaking capacity specified for breakers is Ics value (service rating).
The instrument chamber shall be separate and shall comprise of flush type ammeter,
voltmeter, selector switches, cast resin type CT's & PT's, etc. Separate CT's shall be provided
for protective and measuring system.
All Energy Analyser / TVM Shall have RS 485 Modbus RTU on board Communication protocol
for SCADA communication.
The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.
GA drawings shall be got approved from Owners / Architects / Consultants before
fabrication.The panel has to be specifically fabricated as per the space available at Stilt
It shall be electrically & Mechanically interlocked with both incoming & Bus coupler's
contactor in such a way that at any one time two supply should not get mixed up.
i. 1 nos 400 AMP FP MCCB of 35 KA with following accessories
ii. Metering for incomers
iii. 1 nos. Under voltage relay with timer.
iv. 0-500 volt range voltmeter with selector switch (P.T. connected)
v. 1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for metering.
1 set of 3 CT's of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR.
1 nos. Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of
Conzerve or equi.) with RS 485 communication port for communication / report generation.
Power factor meter.
Frequency meter.
Indications for incomers
3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB.
1 nos. 400 Amps FP MCCB Bus coupler (35 KA)
It shall be electrically & Mechanically interlocked with both incoming & Bus coupler's
contactor in such a way that at any one time two supply should not get mixed up.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
3 Nos. LED type phase indicating lamps, 3 Nos. LED type indicating lamps for indicating the
status of feeder - ON / OFF / TRIP. each lamp shall be with bakup HRC fuse/MCB.
1 section of 500 AMP , 415 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium
bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat
shrinkable sleeves and clip on shrouds for joints.
The current density of bus bar up to 400 Amp shall be minimum 1.00 sq mm / amp.
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The
temperature rise should be restricted to 35 deg C above design ambient temperature of 50
All outgoing feeders shall be provided with one set of phase indication lamps and trip
indication lamps with protection fuses/MCB and ammeter with selector switch with suitable
ratio CT's of accuracy class 1.0
3 No. 300 amps 4P MCCB 35kA outgoing feeder .
2 No. 200 amps 4P MCCB 35kA outgoing feeder
2 No. 200 amps 4P MCCB 35kA outgoing feeder
4 No. 250 amps 4P MCCB 35kA outgoing feeder .
2 No. 100amps 4P MCCB 35kA outgoing feeder .
TOTAL CARRIED TO SUMMARY 1 1,467,235.14 1,467,235.14
B CAPACITOR PANEL
Design, manufacture, supply, inspection, handling, assembling, affecting proper
connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical
type 100 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR capacitor units in tier
formation, housed in an integrated cubicle type automatic switching ON and OFF control
panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP
52, powder coated after proper treatment with 9 tank process with top/bottom removable
gland plates, as required, double compression type cable glands, earth bus, hinged and
lockable doors to achieve dust and vermin proof complete with all inter connections small
wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of
suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 .
The incoming MCCB shall be microprocessor based with inbuilt O/L & S/C release with E/F
protection and All outgoings MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C
All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with
adjustable O/L & S/C trip setting as per load requirement. All TP MCCB's shall be with AC 3
duty contactor for neutral isolation. All TP MCCB shall be with heavy duty solid isolable
neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be
separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's,
Capacitor duty contactors should be used for switching individual capacitor banks.
The fault withstanding capacity of panel & its control gear shall be min. 35 KA rms for 1 sec.
Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation
The maximum height of the panel should not exceed 2100 mm unless specifically approved.
The capacitor panel shall be integrated with the main L T Panel as per schematic diagram.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
1 no. 200 AMP. Three Pole, MCCB with heavy duty solid neutral link, with O/C , S/C, E/F
protection, adjustable thermal magnetic release, 35 KA Breaking Capaciy.
1 set- 3 CTs , ratio 200/5A Class 1.0 accuracy 15 VA burden for metering.
1Nos- (0-250A) digital Ameter with selector switch
Micro processor based automatic power factor control relay (3 phase) (including power
factor meter) in 16 steps for automatic cut off or add on capacitor units to keep the power
factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be
provided with in the scope of work.
Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to
indicate On/Off status of capacitor unit.
200 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of
suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable
sleeves and clips on shrouds for joints. The current density of bus bar shall be minimum 1.00 sq
The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The
temperature rise should be restricted to 35 deg C above ambient temperature.
1 no. of 125 AMPS TPN 35 KA MCCB and 80 amps AC3 duty contactor with 50 KVAR gas filled
415 V capacitor bank, auto-manual selector switch, start stop push button for manual
operation including on/off indicating lamps and delay timer complete.
1 no. of 63 AMPS TPN 35 KA MCCB and 80 amps AC3 duty contactor with 20 KVAR gas filled
415 V capacitor bank, auto-manual selector switch, start stop push button for manual
operation including on/off indicating lamps and delay timer complete.
2 no. of 63 AMPS TPN 35 KA MCCB and 80 amps AC3 duty contactor with 10 KVAR gas filled
415 V capacitor bank, auto-manual selector switch, start stop push button for manual
operation including on/off indicating lamps and delay timer complete.
2 no. of 25 AMPS TPN 35 KA MCCB and 32 amps AC3 duty contactor with 5 KVAR gas filled
415 V capacitor bank, auto-manual selector switch, start stop push button for manual
operation including on/off indicating lamps and delay timer complete.
C FEEDER PANELS
1 ESSENTIAL LIGHTING FEEDER PILLAR
Design, manufacture, supplying fixing in position of outdoor type feeder pillar, metal clade,
suitable for 415 volt, 3-phase, 50 Hz with suitable foundation and arrangement for incoming/
outgoing cable termination, earthing, locking arrangement, insulated aluminium bus bars
system, interconnection etc.
200 amps TP+N MCCB with following accessories:
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
1 Set of 200A TPN Aluminium Bus Bar with colour coded PVC Sleeves
63A DP MCB -14 No.
25A FP MCB -4 No.
EXTERNAL LIGHTING FEEDER PILLAR _ described as above Set 2 195,631 391,262
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
2 BUILDING FEEDER PANEL-1
BUILDING FEEDER PANEL-1( SCHOOL BUILDING, WTP,Borewell & Pump Room)
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 300 amps 4P 36 kA, Moulded Case Circuit Breaker with TM release
Digital electronic VAF meter with and 300/5 Amps 5 VA, CL 1 CTs . - 1 Set
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
300 Amps 4 Pole 36 kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
1 No. 250 amps 4 Pole MCCB 36kA outgoing feeder.
3 No. 150 amps 4 Pole MCCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-1_as described above. Set 1 293,447 293,447
3 BUILDING FEEDER PANEL-2
BUILDING FEEDER PANEL-2 (School building, Multi purpose hall, Guard room)
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 250 amps 4P 36 kA, Moulded Case Circuit Breaker with TM release
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Digital electronic VAF meter with and 250/5 Amps 5 VA, CL 1 CTs . - 1 Set
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
250 Amps 4 Pole 36 kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
2 No. 250 amps 4 Pole MCB 36A outgoing feeder.
1 No. 150 amps 4 Pole MCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-2_as described above. Set 1 293,447 293,447
4 BUILDING FEEDER PANEL-3
BUILDING FEEDER PANEL-3 (Boys Warden Residence, Boys Dormitiory)
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 250 amps 4P 36 kA, Moulded Case Circuit Breaker with MP release
Digital electronic VAF meter with and 250/5 Amps 5 VA, CL 1 CTs . - 1 Set
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
250 Amps 4 Pole 356kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
1 No. 250 amps 4 Pole MCCB 36kA outgoing feeder.
1 No. 150 amps 4 Pole MCCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-3_as described above. Set 1 293,447 293,447
5 BUILDING FEEDER PANEL-4
Girls Dormitiory, Girls Warden Residence
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 250 amps 4P 36 kA, Moulded Case Circuit Breaker with MP release
Digital electronic VAF meter with and 250/5 Amps 5 VA, CL 1 CTs . - 1 Set
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
250 Amps 4 Pole 36 kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
1 No. 250 amps 4 Pole MCCB 36kA outgoing feeder.
1 No. 150 amps 4 Pole MCCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-4_as described above. Set 1 293,447 293,447
6 BUILDING FEEDER PANEL- 5
Kitchen, Principal Residence, Borewell-2
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 250 amps 4P 36 kA, Moulded Case Circuit Breaker with MP release
Digital electronic VAF meter with and 250/5 Amps 5 VA, CL 1 CTs . - 1 Set
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
250 Amps 4 Pole 36 kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
1 No. 250 amps 4 Pole MCCB 36kA outgoing feeder.
2 No. 150 amps 4 Pole MCCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-4_as described above. Set 1 293,447 293,447
7 BUILDING FEEDER PANEL- 6
Type-II Residential quarter, Type-III Residential quarter , Vice Principal Residence
& Guest house, STP
Design, manufacture, supplying fixing in position of the following front operated cubicle
type, front access, dead back, 2mm thick steel enclosed free standing, dust and vermin
proof, switchboard with IP52 protection with hinged and lockable doors complete with
interconnections, tinned copper/Al crimping lugs, bonding to earth and painting, suitable for
use at 415 volts, 3 phase 4 wire 50 Hertz system, and suitable for a fault level of 35 kA
symmetrical at 415 volts . It should be complete with in all respects as per techinical
specifications.
1No. 300 amps 4P 36 kA, Moulded Case Circuit Breaker with MP release
Digital electronic VAF meter with and 300/5 Amps 5 VA, CL 1 CTs . - 1 Set
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Additional earth fault protection will be provided in all incoming MCCBs.
Metering & Indication
1 set of R,Y,B phase indicating lamps each with 3 nos. 6A SP MCBs.
Phase indicating light shall be protected by 6A MCB. - 1 Set
300 Amps 4 Pole 36 kA for 1 sec. Alumminium bus bars with heat coloured shrinkable
insulation sleeve. - 1 Set
3 No. 200 amps 4 Pole MCCB 36kA outgoing feeder.
3 No. 150 amps 4 Pole MCCB 36kA outgoing feeder.
BUILDIN FEEDER PILLAR-4_as described above. Set 1 293,447 293,447
TOTAL CARRIED TO SUMMARY 2,151,944.09
D HT & LT CABLES
Supply, installation, testing and commissioning of the following HT & LT cables or approved
11 KV Grade HT Cable
Supply of following sizes of XLPE insulated PVC sheathed aluminium conductor armoured
power cable of 11kV grade H.T. Cable shall be of earthed grade and shall be of stranded
construction, comply to IS 8130., and with electrolytic grade purity aluminium conductor,
shall be manufactured & tested in accordance with IS : 7098 (Part II). Outer sheath shall be
of tough, PVC compound as per IS: 5831 and shall be extruded over the armouring.
etc.complete as per technical specifications.
LAYING OF HT CABLES
Laying of 11 kV Grade HT Cables
Laying of one number XLPE power cable of 11 KV grade of following size in in Ground,
Surface and Cable Trays and Load in Hume Pipe/Duct. etc.complete as per technical
specifications.
2.1 Above 120 sq. mm and upto 400 sq. mm Mtr 50 577 614 597 29,848 DSR-8.1.2
11 kV HT CABLE END TERMINATION
Supplying & making indoor cable end termination with Heat shrinkable jointing kit complete
3 with all accessories, bimetallic washers and including lugs for the following size of 3 core XLPE DSR-10.1
aluminium conductor cable of 33kV grade complete as required.
3.1 3 C x 240 sq.mm 11 KV XLPE (E) cable (indoor type) SET 4 3549 3,774 3,672 14,687 DSR-10.1.3
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Supplying & making Outoor cable end termination with Heat shrinkable jointing kit complete
4 with all accessories, bimetallic washers and including lugs for the following size of 3 core XLPE DSR-10.2
aluminium conductor cable of 33kV grade complete as required.
4.1 3 C x 240 sq.mm 11 KV XLPE (E) cable (indoor type) SET 4 6293 6,691 6,511 26,043 DSR-10.2.3
Supply of XLPE insulated, armoured heavy duty electric cable with aluminium conductor,
1100 volts grade, cross-sectional area as follows
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories
like socket, bend, couplers etc. conforming to IS 14930, Part II complete With fitting and
2 cutting, jointing etc-direct in ground (75 cm below ground level) including excavation and DSR-14.16
refilling the trench but excluding sand cushioning and protective covering etc.complete as
90 mm dia COD-90 mm & ID-76 mm nominal) Mtr 829 290 308 300 248,726 DSR-14.16.2
120 mm dia COD-120 mm & ID-103 mm nominal) Mtr 246 368 391 381 93,659 DSR-14.16.3
Laying of one number PVC insulated and PVC shethed/XLPE power cable of 1.1 KV grade of
following size in the existing RCC/HUME/Metal pipe as required
Above 35 sq. mm and upto 95 sq. mm Mtr 829 57 61 59 48,888 DSR-7.5.2
Above 95 sq. mm and upto 185 sq. mm Mtr 246 77 82 80 19,597 DSR-7.5.3
Above 185 sq. mm and upto 400 sq. mm Mtr 482 134 142 139 66,822 DSR-7.5.4
Supplying and making end termination with brass compression gland and aluminium lugs for
4 following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 DSR-9.0
KV grade as required.
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
TOTAL CARRIED TO SUMMARY 2116202.922 5588002
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing
masonry enclosure with cover plate having locking arrangement and watering pipe etc. Each 22 6855 7,289 7,092 156,027 5.2
with charcoal/ coke and salt as required,
Providing & fixing of 25mm x 5mm GI strip on surface or recess for earth connection as
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Meter 300 70 74 72 21,726 5.16
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and
providing masonry enclosure with cover plate having locking arrangement and watering Set 8 13838 14,714 14,317 114,533 5.6
pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc.
TOTAL CARRIED TO SUMMARY 368,142.62 0.00
F EXTERNAL LIGHTING
Supply, installation, testing and commissioning of the following lighting fixtures & poles or
approved equivalent:
1.1 Outdoor street light fixture with 45W LED complete with all accessories as required. No. 63 8,458 532,845 MR
Outdoor Integrated all-in-one solar street light with pole and Lithium Ferro Phosphate
battery, solar panel and charger built into the luminaire. Pressure die cast aluminium for
1.2 sturdiness and long life. Specially designed pole mounting bracket allows different tilt angles, No. 6 30,011 180,065 MR
lateral and pole top mounting. SunStay has highest ever system efficacy of more than
175lm/w. with all accessories as required. (50 W)
Supply Installation Testing Commissioning of GI 6.0 mtr octagonal Pole with 1200mm single
Arm with inbuilt weather proof junction box including CC foundation (1:2:4 cement concrete
(1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size) including
1.3 excavation & refilling etc minimum size 350mm x350mmx500mm with 300mm x 300mm x10 Nos 63 12,277 773,435 MR
mm Base plate including 4 Nos. heavy duty foundation nut bolts with suitable length as
required and complete in all respect as per direction of Engineer in Charge as complete
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Supply, Installation, Testing and Commissioning of (4W-9W) Bollard lighting fixture with IP54
TOTAL CARRIED TO SUMMARY 0.00 1,601,614
G 11 KV HT Structure
1 11 KV HT Structure
SITC of Complete set as required
Erection of steel tubular pole of length 10-12
mtr. in cement concrete 1:3:6 foundation
including excavation and refilling etc as
Supplying and erection of galvanised stay set
for 11 KV over head lines complete with 19/
20 mm dia X 1.8 metres long stay rod,
anchor plate of size 45 cm X 45 cm X 7.5
mm thick, thimble, stay clamps, turn buckle (
20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay
wire and 11 KV strain insulator etc in
cement concrete 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 40 mm
nominal size ) foundation including
excavation and refilling etc. as required
Supplying of two lengths of channel iron 75
mm X 40 mm X 6 mm (7.14 kg per metre)
double pole cross arm for three wire 11KV
over head line conductors complete with
through bolts and nuts for clamping to the
poles, 50mmX 6 mmM.S.flats welded on
one side to the channel iron and with bolts
and nuts on the other side for tying the cross
arms together, including drilling holes for
insulator pins/ fittings, bolts, nuts and
washers etc (as per drawing) and painting
with primer and finish paint as required
Supplying and erection of a set of cross
bracing FRLSame work for 11 KV over head
line double pole structure having four
members fabricated out of 50 mm X 50
mm X 6 mm angle iron to form a rectangle
of minimum size 1400 mm width X 2500
mm height, complete with 50 mm X 6mm
M.S. flat iron clamps, bolts and nuts
including drilling holes for insulator pins,
bolts and nuts etc (as per drawing) and
painting with primer and finish paint as required
Supply and Erection of 440 V shackle
insulator with G.I bolt nut and washer as
Supply & Erection of 100X65 mm pin
insulator complete set with GI spindle and
nuts as required
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
TOTAL CARRIED TO SUMMARY SET 2 143,236 286,471
SITC of 250 KVA, 33/0.433 KV 3 Phase 50
cycle oil immersed, naturally cooled, outdoor type transformer connected
delta on H.T. side and star on L.T. side, hand operated off load Tap changer
switch, 250 KVA, rating Copper wound ,Energy efficiency level -2 and
diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve
with plug, temperature not exceeding 50 º C on load, oil conservator with
1 drain plug, oil filling hole with plug, dehydrating silica gel breather on eye MR
level, four unidirectional roller, arcing horns, explosion vent, terminal
arrangement bushing on H.V. side and cable box on LV side, first filling of
oil upto desired level with required materials arrangement as required ISI
marked & as per IS specification. and confirming to IS 1180 level 2 as per
specificationattached complete in all respects as required at site.Contactor /Vendor shall
submit shop drawing to consultant before implementation.
SAFETY EQUIPMENTS;
Supply, installation, testing and commissioning of all safety Equipments.
2 Supplying of Rubber hand gloves suitable for 1 kV. Pair 1 MR
3 Supply & fixing of Rescue Hook,Discharge Rod of 11Kv grade required in panel room Set 1 MR
Supplying and fixing of Shock treatment chart both in Regional, Hindi,Tamil & English.and
framed with 5mm thick glass as required.
Supply & fixing MV danger notice plate of 200 mm x 150mm, made of mild steel sheet of at
5 least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red Each 1 DSR-2.21
colour on front side as required.
Supply & fixing HT danger notice plate of 250 mm x 200mm, made of mild steel sheet of at
6 least 2mm thick & vitreous enamelled white on both sides and with inscription in signal red Each 1 DSR-2.22
colour on front side as required.
Supply of First aid box containing material as prescribed by St. John Ambulance brigade OR
Indian Red Cross complete as required.
Providing of Insulation mat 1 meter wide & 2.5mm thick to withstand 36kV dielectric strength
as per IS 15652- 2006
9 Supply & fixing of 2nos. Sand bucket with stand and other accessories. set 1 MR
10 Supply & fixing of 1nos. Dos & don't chart and other accessories. nos. 1 MR
Supply, installation, testing and commissioning fire extinguisher of carbon dioxide type
consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the
approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal
discharge tube, 1 meter long high pressure discharge hose, non conducting horn,
suspension bracket, fully charged bearing IS: making fixed to wall as directed conforming IS :
Capacity 4.5 Kg. nos. 1 MR
TOTAL CARRIED TO SUMMARY SET 2 1,159,863 2,319,726
PROVIDING, INSTALLING, TESTING AND COMMISSIONING OF 'SILENT TYPE' DIESEL GENERATING SET
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Supply, installation, testing and commissioning of 82.5 KVA Dual Fuel Mode DG set with
Acoustic Enclosure along with electronic governor with AMF Panel with 200 A 4Pole MCCB
35kA, base frame, Alternator (capable of delivering true 82.5 kVA output), Static Excitation
System, Lube Oil System, Batteries, Battery charger, Instrumentation, 200 liter day oil fuel
tanks, Silencer with bellows, alarms, Engine Control Panel, AVM pads, AVR Panel,Terminal
arrangements in termination box suitable to 3.5cx50 sqmm aluminium cables with all other
associated equipment / work as per specifications. complied latest CAQM/DPCC Pollution
prevention guidelines and Also as per latest CPCB norms.
Supply, installation, testing and commissioning of exhaust pipe 'B' class heavy duty MS pipe
with all fixing accessories and hardwares. The exhaust pipes shall be insulated with 75 mm
thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium
sheet including all support. complete set.
TOTAL CARRIED TO SUMMARY SET 2 1,521,019 3,042,037
LT Panels Locations -
1. Type-II Residential quarter,
2. Type-Type-III Residential quarter 10,
3. Type-III Residential quarter 8
SITC of Main Incomer With Metering & Control
200 A FP MCCB 36KA With Microprocessor based release having S/C & O/L Protection.
Digital VAF Meter, Class 1.0, 96sq mm
Resin Cast CT 200/5A Class 1.0 For metering
Phase Indication Light Led R,Y,B 220V AC
Control MCB 6A SP 10KA
Isolating Neutral Link 32A
Electrolytic Grade Aluminium Busbar with PVC Heat Shrinkable Colour Coated Sleeve Suitable for
Incoming & Outgoing Feeders (Main Busbar 200A, FP Aluminium
Outgoing Section - -
2 No. 100A 25kA Thermal Magnetic Release based MCCB (With S/C,O/L Protection)
1 No. 63 amps 4 Pole MCCB 25kA outgoing feeder.
TOTAL CARRIED TO SUMMARY Set 3 289,197.90 867,593.69
LT Panels Locations -
1. Principal Residence
2. Vice Principal Residence
3. Girls Warden Residence
4. Boys Warden Residence
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SITC of Main Incomer With Metering & Control
150 A FP MCCB 36KA With Microprocessor based release having S/C & O/L Protection.
Digital VAF Meter, Class 1.0, 96sq mm
Resin Cast CT 150/5A Class 1.0 For metering
Phase Indication Light Led R,Y,B 220V AC
Control MCB 6A SP 10KA
Isolating Neutral Link 32A
Electrolytic Grade Aluminium Busbar with PVC Heat Shrinkable Colour Coated Sleeve Suitable for
Incoming & Outgoing Feeders (Main Busbar 150A, FP Aluminium
Outgoing Section - -
2 No. 150 amps 4 Pole MCCB 25kA outgoing feeder.
1 No. 63 amps 4 Pole MCCB 25kA outgoing feeder.
TOTAL CARRIED TO SUMMARY Set 8 266,007.47 2,128,059.77
LT Panels Locations -
1. Girls Dormitiory
2. Boys Dormitiory
4. School & School Courtyard
5. Multi purpose hall
SITC of Main Incomer With Metering & Control
250 A FP MCB 25KA With Microprocessor based release having S/C & O/L Protection.
Electrolytic Grade Aluminium Busbar with PVC Heat Shrinkable Colour Coated Sleeve Suitable for
Incoming & Outgoing Feeders (Main Busbar 250A Aluminium)
Outgoing Section - -
2 No. 200 amps 4 Pole MCCB 25kA outgoing feeder.
1 No. 63 amps 4 Pole MCCB 25kA outgoing feeder.
TOTAL CARRIED TO SUMMARY
TOTAL CARRIED TO SUMMARY 4,578,056
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
CONSTRUCTION Of JNV PHASE-A WORKS AT JAFFARPUR
SUMMARY OF EXTERNAL PLUMBING WORK
S. No. Description DSR Amount NON DSR Amount
1 EXTERNAL WATER SUPPLY 1,398,351.89 30,575.86
2 SEWERAGE & DRAINAGE NETW 2,363,591.45 444,887.13
3 RAIN WATER HARVESTING PIT 1,533,471.98 -
5 UNDERGROUND TANK 4,341,855.25 675,800.00
8 SEPTIC TANK 3,952,256.74
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
BOQ EXTERNAL PLUMBING
S.No DSR RATE CORRECTION
ITEM UNIT 2023 FACTOR QUANTITY DSR AMOUNT NDSR AMOUNT'
0.973 EXTERNAL TOTAL
[1] EXTERNAL SERVICES
EXTERNAL WATER SUPPLY
Excavating trenches by mechinical / manual means of
required width for pipes, cables, etc including excavation
for sockets, and dressing of sides, ramming of bottoms,
for all depth, including getting out the excavated soil, and
1 2.1 then returning the soil as required, in layers not
exceeding 20 cm in depth, including consolidating each
deposited layer by ramming, watering, etc. and disposing
of surplus excavated soil as directed, within a lead of 50
2.10.1 All kinds of soil
1.1 2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. metre 215.60 209.78 1,086.91 1,086.91 228,009.84
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded
fittings This includes jointing of pipes & fittings with one
step CPVC solvent cement, trenching, refilling & testing
of joints complete as per direction of Engineer in Charge.
Providing and fixing gun metal gate valve with C.I. wheel
of approved quality (screwed end) :
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
Fixing water meter and stop cock in G.I. pipe line
including cutting and threading the pipe and making
long screws etc. complete (cost of water meter and stop
cock to be paid separately). -
Providing, fixing, joints and testing in position the
following UPVC Pipe confirming to IS:4985 of
10kg/sqcm quickfit type for garden irrigation system cut
to required length pipe to be laid below level in trenches
5 NS-01 up to required depth, including excavation in all kind of
soil (hard rock) dewatering, refilling, watering, ramming
and removing the surplus excavated material and
putting 100 m sand all-around and making good the
Providing, fixing, In position Brass Sprinkler including
6 NS-02 riser pipe & accessories for garden/green area complete Each 2,317.83 6.00 6.00 13,906.97
Providing, fixing, in position 25 mm dia Lawn hydrant
7 NS-03 consisting of 25 mm dia Ball Valve, G.I nipple and Each 6,226.32 2.00 2.00 12,452.65
threaded hose reciever complete as required.
Constructing masonry Chamber 60x60x75 cm inside, in
brick work in cement mortar 1:4 (1 cement : 4 coarse
sand) for sluice valve, with C.I. surface box 100mm top
diameter, 160 mm bottom diameter and 180 mm deep (
inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm
nominal size ) , i/c necessary excavation, foundation
concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone
aggregate 40 mm nominal size) and inside plastering
with cement mortar 1:3 (1 cement : 3 coarse sand) 12
mm thick, finished with a floating coat of neat cement
complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of
Digitally signed by
PRADYUMNA MUKHERJEE
BOQ JNV East Delhi R1
SE SEWERAGE & DRAINAGE NETWORK
Excavating trenches of required width for pipes, cables,
etc, including excavation for sockets, depth upto 1.5 m,
including getting out the excavated materials, returning
the soil as required in layers not exceeding 20 cm in
depth, including consolidating each deposited layers by
ramming, watering etc., stacking serviceable material for
measurements and disposal of unserviceable material as
directed, within a lead of 50 m :
2.10.1.1 All Kind
Pipes, cables etc. exceeding 80 mm dia. but not exceeding
Providing and laying non-pressure NP2 class (light duty)
R. . . pipes with collars jointed with stiff mixture of
cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete :.
Constructing brick masonry circular manhole 1.22 m
intemal dia at bottoni and 0.56 m dia at top in cement
mortar (I cement coarse sat'"dV inside cement plaster 12
mm thick with cement mortar 1:3 (1 cement 3 coarse
sand) finished with a floating coat of neat cement
foundatio@ mncrete 1:3:6 (1 cernent : 3 coarse sand : 6
graded stone aggregate 40 mm nominal size) and
making necessary channel in cement concrete 1:24 (1
cement : 2 coarse sand : 4 graded stone aggregate 20
mm; nominal size) per standard design ;
1.68 m deep with SFRC Cover and frame (heavy duty
HD-20 grade designation) 560 mm internal diameter
conforming to I.S. 12592, total weight of cover and frame
to be not less than 182 kg. fixed in cement concrete 1:2:4
19.11.1 (1 cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12 mm thick
cement plaster atthe external surface shall be paid for
With common bumt clay F.P.S. (non modular)
bricks of class desi nation 7.5 each 24,702.75 24,035.78 40.00 40.00 961,431.03
Digitally signed by
PRADYUMNA MUKHERJEE
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Approved Makes List.pdf
Tender Document
GCC 2022.pdf
Tender Document
Integrity pact.pdf
Tender Document
SCC.pdf
Tender Document
JNV East Delhi ARCH1.pdf
Tender Document
JNV East Delhi ARCH 2.pdf
Tender Document
JNV East Delhi ARCH 3.pdf
Tender Document
Technical Spec.pdf
Tender Document
Technical Ciculars 01-27.pdf
Tender Document
Physical Milestone.pdf
Tender Document
NIT.pdf
Tender Document
Revised BOQ.pdf
Tender Document
corrigendum-3527-Cor-Adm-03.pdf
pdf • 0.17 MB
corrigendum-3143-Corr02 Final.pdf
pdf • 0.44 MB
addendum-4877d31b5e7a-Corr02 Final.pdf
pdf • 0.44 MB
corrigendum-3117-CorrAdm01.pdf
pdf • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .