Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹5.1 L (4.72%)Rejected-Finance 108 3 CHANDAR NAGAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.1 Cr+₹5.1 L (4.72%) | L2 | Rejected-Finance Highest Rate Quoted by bidder |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
26 Dec 2024, 12:00 pmClosed
General Manager (Garhwal)
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, Kamla Nagar(Opp. ONGC Hospital), Dehradun
SITC of compact Substation and accessories work of Multipurpose Hall at Parade Ground Dehradun
2024_MDPEY_78694_1
4931/Nivida(Garh)Elect.DDun/37 Dt.11/12/24
Open Tender
Electrical Works
Item Rate
365 days
DEHRADUN
Please refer tender document
3 documents required · 3 mandatory
₹4,720
PM,Const.Unit(Elect.),UKPJN, Dehradun
₹2.2 L
Dehradun
28 May 2025
13 Dec 2024
27 Dec 2024
13 Dec 2024
26 Dec 2024
16 Dec 2024
14 Dec 2024
Amount
PAR 6.2.1 Supply, Installation, testing and commissioning of (C.S.S) 33 Kv/0.33 Kv or 11 kv/0.433 substation equipment comprising HT panel, transformer, HT cable, bus trunking from transformer to LT panel, LT panel, automatic power factor correction panel, active harmonic filters, TVSS(transient voltage suppression system), SPD, essential panel, earthing required inter-connections substation safety equipments including LT cabling from substation to the building fed by the substation
DSR 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
DSR 7.1.1 Upto 35 sq. mm
DSR 7.1.4 Above 185 sq. mm and upto 400 sq. mm
DSR 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
DSR 9.1.31 3½ X 400 sq. mm (82mm)
DSR 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
DSR 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
DSR 9.4 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
DSR 9.4.18 3½ X 35 sq. mm
DSR 9.4.28 3½ X 400 sq. mm
DSR 10.5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
DSR 10.5.2 120 sq.mm
DSR 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
DSR 5.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Non Schedule Supply, Installatin, testing & commissioning of L.T Panel made of CRCA sheet steel dust and vermin proof with incommer 800 amp with change over switch & outgoing 400 amp FPMCCB 02 nos, & 63 amp FPMCCB 04 nos complete with all respect
Non Schedule Supply ,Installation ,Testing , commissionig and aiming of high wattage LED Floodlight fixture having system wattage of 500W made of aluminium pressure die cast housing to ensure durability in harsh environment and excellant heat dissipation. The Luminaire should have optical cover/lens made of polycarbonate with beam angles ranging from 20° to 60°. The Lumiaire should comply with IK08 mechanical impact protection and IP66 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 60000 Lumens with a system efficacy of 120Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 90 i.e TLCI > 90. the Drivers should be BIS certified with efficiency of > 85%, THD< 10% and P.F>0.95. Surge Protection sholud be Upto 20Kv
Non Schedule Supply ,Installation ,Testing , commissionig and aiming of 1x4 Linear surface mounted LED Luminaire having system wattage of 36W made of CRCA Powder coated body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 3600 Lumens with a system efficacy of 100Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of > 85%, THD< 10% and P.F>0.95. Surge Protection sholud be Upto 4Kv
Non Schedule Supply of 3.5 c x 400 sq.mm L.T aluminium armoured cable
Non Schedule Supply of 3.5 c x 35 sq.mm L.T aluminium armoured cable
Non Schedule Supply of 3 c x 120 sq.mm H.T aluminium armoured cable
Non Schedule Fencing for L.T Panel Room
Non Schedule Installation, testing and commissioning of 630 KVA C.S.S & construction of foundation including supply of material, labour, T&P etc complete.
Non Schedule Shifting/ relocating of existing sports lighting from vertically downward to mount on walls as per requirement of badminton including supply/fabrication of mounting fixture arrangement for light.
MITTAL MACHINES PVT LTD (BID ID -353188)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .