Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹47.9 CrAdmitted-Finance AT GANDAPADA PO CHARMPA PS BHADRAK DIST BHADRAK STATE ODISHA PIN 756163 | BHADRAK | BHADRAK | ODISHA | 756163 | +7.20% | ₹47.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹48.9 CrAdmitted-Finance | +9.60% | ₹48.9 Cr | L2 | Admitted-Finance |
Tender Value
₹44.7 Cr
EMD Value
₹45 L
Closing Date
10 Mar 2026, 5:00 pmClosed
DIRECTOR, PORTS AND IWT, ODISHA, BHUBANESWAR
DIRECTORATE OF PORTS AND INLAND WATER TRANSPORT, GROUND FLOOR, ZONE-A, FORTUNE TOWERS, CHANDRASEKHARPUR, BHUBANESWAR-751023
CIVIL CONSTRUCTION WORKS
2026_PIWT_126287_1
DPIWT-33/2025-26
Open Tender
Civil Works - Others
Arakhakuda under Krushnaprasad Block of Puri Distr
PLEASE REFER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹10,000
₹45 L
Yes
DIRECTORATE OF PORTS AND INLAND WATER TRANSPORT, G
29 Apr 2026
19 Feb 2026
11 Mar 2026
19 Feb 2026
10 Mar 2026
19 Feb 2026
19 Feb 2026 - 25 Feb 2026
26 Feb 2026
Setting up the piling gantry and connected equipment over each pile location, including cost of shifting, cost of all materials for (1000mm Dia Pile) piling gantry, labour, setting up the rig to alignment and correct dimensions as shown in the drawing and as directed by the Engineer-in-Charge.
MAIN JETTY
FINGER JETTY
Boring 600 mm dia piles to the required depth through all types of soil strata including hard rock if any up to the founding level and stacking the bored soil at convenient place and transport to dispose the same at low lying area outside the working area with cleaning & washing the bore including cost of bentonite solution, labour, labour cess, tools, equipments, required to complete in all respect as per direction of the Engineer’-in-charge. Note:- 01. If the boring tool encounters rock at an elevation higher than the termination level of the pile indicated in the drawing then the boring shall be continued one metre into the rock from where the boring tool encounters rock first. 02. In case the soil stratum at the founding level is loose the Engineer or his representative may direct the contractor to carryout additional length of boring and payment for such additional work shall also be made under this item. 03. The sample of bored materials at regular interval shall be collect and produce for the verification of the Engineer or his representative at no extra cost. In the event of any dispute about the type of strata bored, the samples so collected shall be referred to an authorised laboratory / agency indentified by the Engineer and the decision of such authorised laboratory / agency is final and binding on both the parties. However the cost of such testing shall be borne by the contractor.
MAIN JETTY
FINGER JETTY
Providing and fabricating M.S.liners confirming to IS specifications of SAIL of specified thickness for required length with M.S. shoes of 1.0m height using 6mm thick M.S. plates for bored vertical pile measured from cut off level of pile to the terminating level including supplying, cutting, rolling, bending, handling and welding cost, labours, materials, accessories,all taxes, hire and running charges of all machineries, royality, labour, material, T&P, conveyance charges, Port entry fees etc. all complete as per drawings and specification as directed by Engineer-In-charge.
MAIN JETTY
FINGER JETTY
Dismantling of Reinforced Concrete Pile head complete as per drawing and Technical Specification
MAIN JETTY
FINGER JETTY
Providing and laying reinforced cement concrete in concrete mix M40 for pile excluding cost of steel reinforcements in position as per approved drawing and as directed by the Engineer- In-Charge including mixing, laying, consolidating, curing, including all labours, slings, shackles, supply of all labour, material, transportation cost, hire and running charges of all machineries such as cranes, lorries etc., complete as directed by the Engineer-In-Charge.
MAIN JETTY
FINGER JETTY
Providing and laying reinforced cement concrete in concrete mix M35 for Pile Cap excluding cost of steel reinforcements in position as per approved drawing and as directed by the Engineer-In-Charge including shuttering, mixing, laying, consolidating, curing, including all labours, slings, shackles, supply of all labour, material, transportation cost, hire and running charges of all machineries such as cranes, lorries etc., complete as directed by the Engineer-In-Charge.
MAIN JETTY
FINGER JETTY
R.C.C. M-35 Slab with 20 mm. down graded black hand granite crushed broken stone chips including shuttering cost and conveyance of all materials with all taxes, royalty, labour and T&P required for the work etc. complete as directed by the Engineer-in-Charge.
MAIN JETTY
FINGER JETTY
Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-charge. Cold Twisted bars, Thermo-Mechanically-treated bars.
MAIN JETTY
FINGER JETTY
Providing and laying Cement concrete wearing coat M-35 grade including reinforcement complete as per drawing and Technical specifications.
MAIN JETTY
FINGER JETTY
Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2 mm @ 0.90mtrsC/Cand stainless pipe square bracing of size 32mm x 32mm x2mm in 3 row in stair case as per approved design and specification buffaing, polishing etc. eith cost, conveyance and all other taxes of materials, labour charges, T & P etc. required for the work complete in all respect as per specification and directon of Engineer in Charge.
MAIN JETTY
FINGER JETTY
Conducting High Strain Dynamic Test as per standard practices(ASTMD 4945 of 1989) The rate is inclusive of testing, hire charges for all equipments like transducers, strain gauge, oscilloscope hammer crane and cost of development of pile concrete with line and dismantling the developed length of concrete, transportation of equipment, labour and furnishing the test result etc., complete and as directed by the EIC. MAIN JETTY
Bitumenous expansion joint board (I.S.I.) (25mmthick) FOR MAIN AND FINGER JETTY
Supplying, handling, transporting and fixing in position of Cast iron Bollard (20T ton capacity)with necessary cutting, concrete chipping, drilling, grouting, welding with deck reinforcement steel and necessary coal tar painting(wherever required) including all materials, labour,consumable items etc. complete as per drawing and specifications as directed by the EIC. FINGER JETTY
Supplying approved Marine ''D" hallow Rubber fender of size 150 x150 x25 mm as per specification and drawing including cost & taxes of Fender with transport charges to deliver at work site etc. complete in all respect as per the direction of the Engineer in charge. FINGER JETTY
Labour for cutting Marine ''D" hallow Rubber fender of required size and fitting &fixing the same as per specification and drawing along the jetty fender beam using stainless steel Anchore bolts, Nuts and washers of required size by drilling holes in the existing concrete surface and making good good of the damage with cement mortar(1:1) (1cement :1sand) including cost, conveyance, taxes of all materials labour, labour cess,T&P etc. required to complete the work in all respect as per drawing,design specification and direction of Engineer in charge (Excluding cost of Fender) FINGER JETTY
DREDGING
Desilting by Dredging from river /nallah for depths varying from 1.00m to 3.00 m including fixing of pipelines , Floaters and floating pipelines for disposing of water slurry consisting of all kinds of soil including medium fine sand & coarse sand with gravelly earth . The rate shall include the cost of labour , materials , consumables POL, spare parts and accessories to keep dredger , T&P etc. including building in the island by providing geo tubes and accessories or by tin sheets for information of bund for dumping of dredged material with all lead and lift excluding GST as per direction of the Engineer-in-Charge .The job includes all pre and post dredging surveys for payment purpose.
WAITING HALL
Provide, bring to site and install in position at first pile location, all the plants and equipments necessary for bored cast in situ piling work and removing the said plants and equipments after completion of piling work including cost of transportation, labour, labour cess & all other taxes etc. complete in all respect as per direction of Engineer-in-Charge.
Boring 600 mm dia piles to the required depth through all types of soil strata including hard rock if any up to the founding level and stacking the bored soil at convenient place and transport to dispose the same at low lying area outside the working area with cleaning & washing the bore including cost of bentonite solution, labour, labour cess, tools, equipments, required to complete in all respect as per direction of the Engineer’-in-charge. Note:- 01. If the boring tool encounters rock at an elevation higher than the termination level of the pile indicated in the drawing then the boring shall be continued one metre into the rock from where the boring tool encounters rock first. 02. In case the soil stratum at the founding level is loose the Engineer or his representative may direct the contractor to carryout additional length of boring and payment for such additional work shall also be made under this item. 03. The sample of bored materials at regular interval shall be collect and produce for the verification of the Engineer or his representative at no extra cost. In the event of any dispute about the type of strata bored, the samples so collected shall be referred to an authorised laboratory / agency indentified by the Engineer and the decision of such authorised laboratory / agency is final and binding on both the parties. However the cost of such testing shall be borne by the contractor.
Providing and fabricating M.S.liners confirming to IS specifications of SAIL of specified thickness for required length with M.S. shoes of 1.0m height using 6mm thick M.S. plates for bored vertical pile measured from cut off level of pile to the terminating level including supplying, cutting, rolling, bending, handling and welding cost, labours, materials, accessories,all taxes, hire and running charges of all machineries, royality, labour, material, T&P, conveyance charges, Port entry fees etc. all complete as per drawings and specification as directed by Engineer-In-charge.
Cutting and dressing pile heads to required line and level and /or as directed and stacking the debris at convenient place and transport the same to any low lying area outside the working area and all associated cleaning of projecting reinforcements including all labour, labour cess, materials, tools, equipments etc., complete in all respect as per direction of the Engineer-in-charge.
Earth work in excavation of foundation inhard soil within 50m initial lead &1.5 M initial lift including rough dressing and leveling the bed and depositing the excavated materials away from the working areas as per specification and directon of Engineer in Charge.
Filling foundation & Plinth with filling sand including all cost , conveyance complete as per specification and directon of Engineer in Charge.
P.C.C of (1:3:6 ) with 4 cm down H.G.C.B metal includig hoisting, laying, compacting, curing and wateringetc. with all t&P required for the work including cost con veyance royality and all other taxes of materials compelte in all respect as per specification and directon of Engineer in Charge.
Providing and laying reinforced cement concrete in concrete mix M35 for Pile Cap excluding cost of steel reinforcements in position as per approved drawing and as directed by the Engineer-In-Charge including shuttering, mixing, laying, consolidating, curing, including all labours, slings, shackles, supply of all labour, material, transportation cost, hire and running charges of all machineries such as cranes, lorries etc., complete as directed by the Engineer-In-Charge.
Providing and laying reinforced cement concrete in concrete mix M40 for pile excluding cost of steel reinforcements in position as per approved drawing and as directed by the Engineer- In-Charge including mixing, laying, consolidating, curing, including all labours, slings, shackles, supply of all labour, material, transportation cost, hire and running charges of all machineries such as cranes, lorries etc., complete as directed by the Engineer-In-Charge.
Providing, lifting, hoisting and laying Reinforced cement concrete of M-35 grade as per approved designs and drawings having a minimum compressive strength (in work test) 350 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. at all floors and all heights. (Note:- Before Execution of Foundation Plate Load Test to be done by the contractor as per instruction of the Engineer-In-Charge)
GROUND FLOOR
Plinth beam length
Col. above P.B. to Slab Bottom
Lintel & Sill band
Chajja
roof Volumn & staircase
Roof Beam
FIRST FLOOR
Col. above G. Floor Slab. to First floor Slab Bottom
Lintel
Chajja for
Roof Beam
roof Volumn & staircase
TERRACE FLOOR
Column, Beam, C1
Lintel
Head room Slab
Chajja
Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-charge. Cold Twisted bars, Thermo-Mechanically-treated bars.
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Brick works with fly ash bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than75 Kg/ cm2 with dimensional tolerance + or - 2% in cement mortar (1:6) in foundation including cost conveyance,royality and all other taxes of materials etc. with curing complete in all respect as per specification and directon of Engineer in Charge.
Brick works with fly ash bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than75 Kg/ cm2 with dimensional tolerance + or - 2% in cement mortar (1:6) in Super structure including cost conveyance,royality and all other taxes of materials etc. with curing complete in all respect as per specification and directon of Engineer in Charge.
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Brick works with fly ash bricks 25 cm x 12 cm x 8 cm size having crushing strength not less than75 Kg/ cm2 with dimensional tolerance + or - 2% in cement mortar (1:4) in Super structure including cost conveyance,royality and all other taxes of materials etc. with curing complete in all respect as per specification and directon of Engineer in Charge.
GROUND FLOOR
FIRST FLOOR
16 mm thick cement plaster in cement mortor (1:6) over brick Masonary including cost and conveyance of all materials with all the taxes, royality, labour, T & P required for the work etc. complete as per specification and directon of Engineer in Charge.
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
12mm (1/2")thick cement plaster in cement mortar (1:4) over brick work,roof slab & R.C.C.work including cost, conveyance, royality and all other taxes of materials with curring etc.complete as per specification and direction of Engineer-in-charge
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Providing and laying Vitrified floor tiles 1200x1800 mm (thickness to be specified by the manufacturer) 1st quality conforming to IS: 15622 of NITCO, VARMORA, ASIAN, KAJARIA or equivalent approved make, colours & shades, except white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1cement: 4coarse sand ) including pointing the joints with white cement and matching pigments, etc. complete as per direction of EIC at all floors and all heights.
GROUND FLOOR
FIRST FLOOR
Supplying,fitting &fixing Ceramic Wall tiles in walls,skirting and risers of step on 12mm thick bed of cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including cost, conveyance, all taxes etc. complete. as per direction of Engineer in charge
GROUND FLOOR
FIRST FLOOR
Supplying,fitting & fixing Granite tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) (1 cement, 1 sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including cost, conveyance, all taxes etc. complete as per specification and directon of Engineer in Charge.
GROUND FLOOR
FIRST FLOOR
Finishing surface of walls with cement based wall putty ( Water Based ) of approved make to make it finished smooth & even surface including cost of paint , materials, taxes , labour, labour cess, and T&P etc. required to complete the work in all respect as
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Priming one coat with water bound cement primer and all other materials including cost of paint and Labour charges etc. Complete in all respect as per specification and directon of Engineer in Charge.
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures including cost of all door fittings and fixtures etc. complete
GROUND+FIRST+TERRACE FLOOR
Providing and fixing of Partly fixed, partly top hung and partly louvered windows of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS- 513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Section for internal top and bottom frames in the louvered areas should be 18 x 40 mm.Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete including cost of materials all taxes, labour, labour cess, T&P including cost of glass etc. complete as per specification and directon of Engineer in Charge.
GROUND FLOOR+ FIRST FLOOR
Supplying,fitting & fixing 30mm WPC Door with 125mm x 65mm Frame for Choukath with all cost, conveyance, taxes,labour,T&P,with all fittings, hire charges of drilling machine, labour,T&P, etc complete in all respect as per direction of Engineer in charge.
GROUND FLOOR+FIRST FLOOR+TERRACE FLOOR
Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2 mm @ 0.90mtrsC/Cand stainless pipe square bracing of size 32mm x 32mm x2mm in 3 row in stair case as per approved design and specification buffaing, polishing etc. eith cost, conveyance and all other taxes of materials, labour charges, T & P etc. required for the work complete in all respect as per specification and directon of Engineer in Charge.
GROUND FLOOR+ FIRST FLOOR
Supplying, fitting & fixing of G.I. Window Grills of approved design including cost,conveyance, fabrication charges,labour,T&P required as per direction of engineer in charge.
GROUND FLOOR+FIRST FLOOR
Priming one coat with any approved primer including cost of paint.conveyance,labour,T&P required as per specification and directon of Engineer in Charge. ( For Iron work)
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Finishing walls with weather coat (ISI) of approved shade on new work i.e. two coats to gaive an even shade including cost ofa weather cost and labour charges with curing etc. complete in all respect as per specification and direction of Engineer in charge.
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Painting two coats with approved paints on new iron work including cost of paint, materials, taxes , labour, labour cess, and T&P etc. required to complete the work in all respect as directed by Engineer In Charge
GROUND FLOOR
FIRST FLOOR
TERRACE FLOOR
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025.
FOR GROUND & FIRST FLOOR
Providing and fixing stainless steel (Grade 304) member made of hollow tubes, S.S. wires, channels, plates, etc., including welding, grinding, buffing, polishing, and making curvature (wherever required), and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the member with necessary accessories and stainless steel dash fasteners, stainless steel bolts/anchor fasteners of Hilti make, etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (For payment purposes, only the weight of stainless steel members shall be considered.)
GROUND FLOOR+ FIRST FLOOR
Wall painting two coats with plastic emulsion paint of approved shade to give an even shade including cost of paint and labour charges etc. complete in all respect as per direction of Engineer-in-charge.
GROUND FLOOR
FIRSR FLOOR
TERRACE FLOOR
Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm in both ways injecting chemical with water in propertion (1:20) or any approved propertion in floor and plinth & junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour, labour cess, conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge. GROUND FLOOR
ACP Panel Lining Work: Supplying and fixing of aluminium composite cladding with skin material comprising 0.5 mm thick aluminium sheet cover material, natural polyethylene aluminium cladding panel, fixed with extruded aluminium base frame (50x25x1.5mm) angle cleats, weather sealants, rivets, and GI brackets, all as approved. This includes using suitable bolts on structural steel work, incorporating necessary accessories, and completing all labour charges, etc., for the finished item of work. However, it excludes the cost of structural steel fabrication and scaffolding charges, if any. The ACP cladding is 4 mm thick.
TERRACEFLOOR Waterproofing Treatment :- Terrcae Roof Top Surface. Providing and installing two component acrylic modified cementitious waterproofing coating with masterseal 551/Equivalent over roof slab after carrying out pond test on roof slab filling all defects, saturating the surface mixing the products and then application in 2 mm thickness (1.8kg/sqm coverage rate for 1mm thickness ) in suitable layers complete in all respect, all materials, tools,plant & labour complete in all respect. ( Approved rate for MPH building Sl no-05)
PARKING AREA
Earthwork in excavation of foundation trenches in All kinds of soil including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge.
Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. `
Construction of subgrade and earthen shoulders with approved material obtained from borrowpits having CBR not less than 8% with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300-2
Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. In depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. (Measurement will be taken on finished compacted section only).
Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018.
Supplying and fixing of Pre cast kerb stone of size 300mm x 300mm x 150mm of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction fixed in required pattern etc. complete in all respect conforming to IS 5758:1984.
Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
TOUCH PILE
Providing and laying of Filter media with stone crushed aggregates of 63mm & 45 mm size satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification as directed by the Engineer-in-charge.
Bored cast-in-situ M35 Grade R.C.C. Pile dia 450mm( Touch Pile) excluding Reinforcement complete including bailing, flushing the bore bentonite with required density, chiselling, shifting of materials etc as per Drawing and Technical Specifications and removal of excavated earth with all lifts and lead upto 1000 m complete as per directed by the Engineer-In-charge.
Cutting and dressing pile heads to required line and level and /or as directed and stacking the debris at convenient place and transport the same to any low lying area outside the working area and all associated cleaning of projecting reinforcements including all labour, labour cess, materials, tools, equipments etc., complete in all respect as per direction of the Engineer-in-charge.
Providing and laying reinforced cement concrete in concrete mix M35 for Capping beam excluding cost of steel reinforcements in position as per approved drawing and as directed by the Engineer-In-Charge including shuttering, mixing, laying, consolidating, curing, including all labours, slings, shackles, supply of all labour, material, transportation cost, hire and running charges of all machineries such as cranes, lorries etc., complete as directed by the Engineer-In-Charge.
Bored cast-in-situ M35 Grade R.C.C. Bollard Dia 250mm excluding Reinforcement complete as per Drawing and Technical Specifications and removal of
Supplying, straightening, cutting, bending, placing in position and binding reinforcement steel work in RCC/reinforced brick works as per drawing and specification including preparation of respective bar bending schedule and binding (Binding wire to be used as per the IS code) etc. all complete as per direction of Engineer-In-charge. Cold Twisted bars, Thermo-Mechanically-treated bars.
Earthwork in excavation of foundation trenches in All kinds of soil including dressing of sides and leveling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering and dewatering (if required) with cost of labour, hire & running charges of water pumps sundries & T&P required for the work complete as directed by the Engineer-in-charge.
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
Construction of subgrade and earthen shoulders with approved material obtained from borrowpits having CBR not less than 8% with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300-2
Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600.1, cement content not to be less than 150kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver and compacting with vibratory roller, finishing and curing as per Clause 601 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing and as per Clause 602 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
PH ITEM (INTERNAL)
Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes S.D.R-11 as per IS-15778 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD
25mm dia
20mm dia
Providing all materials, labour, T&P for laying/ fixing of following dia uPVC pipes Sch-80 as per ASTM-D-1785/2004 including fixing of required size PVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD
32mm dia
40mm dia
40mm dia
Providing all materials, labour, T&P for laying/fixing of following dia uPVC pipes as per IS-4985 with ISI mark of 6 kgf/cm2 including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD ( 50mm dia)
Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials, curing, conveyance, taxes of all materials etc. all complete as per specification & direction of EIC.
Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge.For 250mm thick wall
Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge.
Providing all materials, labour, T&P for fitting & fixing of following Brass Ball Valves with ISI mark in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of all duties,transportation scaffolding etc. all complete as per specification and direction of Engineer-in-charge. Make:ZOLOTO/LEADER
40mm dia ball valve
32mm dia ball valve
25mm dia ball valve
40mm dia ball valve
Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china Wall mounted water closet (European pattern) of size with P Trap with seat cover (solid) of approved make in all floor & consealed Flush tank with frame, flush plate including supply of sutaible bracket, PVC wall plug and Brass screws etc. all complete including cost, conveyance as per specification all complete as per direction of Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA. Rate as per CERA S1044178,B1110111,B1120101 or equivalent
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china integrated Half Padestal wash hand basin of size 565 x 460 x 395 mm of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all duties, transportation etc. all complete as per direction of EIC. Make : JAQUAR/HINDWARE/CERA. Rate as per CERA S2010103 with Fixing Accessories
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china under counter wash hand basin of size 550 x 405 x 205 mm of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4) etc. including all duties, transportation etc. all complete as per direction of EIC. Make : JAQUAR/HINDWARE/CERA. Rate as per CERA S2030105 with Fixing Accessories
Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china back inlet urinal basin of size 310 x 300 x 555 mm confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from supply pipe with all taxes, duties, transportation etc. all complete as per specification & direction of the Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA .Rate as per CERA S4020114 or equivalent
Providing all materials, labour, T&P for fitting and fixing of white glazed vitreous china water closet (European pattern) 'P' or 'S' type with cistern & seat cover, wash hand basin with one pair basin bolt, one no. hinged rail 760mm long & 5 nos. grab rails 600mm long including supply of sutaible PVC wall plug and Brass screws etc. suitable for handicapped toilets in all floor etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA. Rate as per HINDWARE 70002 or equivalent
Supplying, fitting and fixing of following types CP fittings of approved make and quality confirming to relevant IS specifications with leak proof threaded joints including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. Make : JAQUAR/HINDWARE/CERA
Hand Shower (Health Faucet) Health Faucet ABS body with 1 meter SS braided connection pipe & Wall Hook (As per Cat. No F8030109AB of CERA)
15mm dia Angular Stop Cock with wall flange (As per CERA F1015201)
Two way Bib cock with Wall Flange (As per Cat. No.F1015163 of CERA)
CP soap dish holder (AS PER F5013116CH OF CERA)
C.P. Toilet Roll holder with stainless steel flap (As per Cat no.F5013110CH of CERA)
Towel Ring Round (As Per F5013115CH OF CERA)
150mmX150mm square anti cockroach trap
32mm Half Thread Waste Coupling (As per F8050102 OF CERA)
32mm Full Thread Waste Coupling (F8050101 OF CERA)
15mmx450 mm Braided Hose Connection Pipe with nuts & washer
Extension Piece(15 x 25 mm)(As per CERA, Cat. No.: F8070301)
32mm dia C.P.Coat Hook(Double)(AsperCat.No.F5003108 OF CERA)
32mm dia CP on Brass Bottle Trap (As per Cat. No. F8060101)
Mirror (700x500mm) (Cat. No: B3510114 of CERA)
Pressmatic Pillar Cock (Cat. No: F9020101 of CERA)
Urinal Valve Auto Closing System with Built-in Control Cock & Wall Flange (F8010109 OF CERA)
SS 304 Service sink (24"x 18" x 10" STEEL sink single bowl) (B4511122 OF CERA)
Sink Cock with Regular Swinging Spout (Wall Mounted Model) With Wall Flange
Providing all materials, labour, T&P for fixing Overhead Shower ø230mm Round Shape (ABS Body & Face Plate Chrome Plated) & Overhead shower arm 450 mm (18”) with wall flange and telephonic shower (F7010602AB,F7040206,F7030313AB of CERA)
Single Lever Exposed Parts Kit of Hi-flow Diverter (F1021721 OF CERA)
Concealed body for single lever highflow diverter F4030101 OF CERA
Spout with wall flange (F1021662 OF CERA)
Providing all materials, labour, T&P for fitting and fixing of 6 lit storage type hot water geyser including all necessary nut, bolts , piping acceosories etc complete
Providing all materials, labour, T&P for fitting and fixing HPL Urinal partition Made of 12 mm thick compact laminate total height 1195 mm , Depth 450 with duties, transportation etc. all complete as per specification & direction of Engineer-in-charge. (Make: Merino)
Providing all labour, T&P and machinaries for installation,commissioning of Three phase sensor with level indicator (Domestic OHT & UGR) and cables etc as per direction of EIC.
Supply, installation,testing & commisioning of water cooler cum purifier with chiller in floor of following capacity including fixing the same on the floor with necessary water connection & waste waste arrengments with all labour, T&P etc.all complete as per the specification & direction of EIC. SS 304 Storage Cooler cum UV Water Purifier 80 lit Capacity 60 ltr per hr cooling capacity, 80 ltr storage Model-AG Green Pure Chill 80SS UV (Eureka Forbes/Kent)
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B) of approved make confirming to IS-13592/1992, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. Make:ASTRAL/ASHIRVAD/FINOLEX (110mm dia soil & Waste pipe)
Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Ringfit) fittings of approved make confirming to IS-14735 in all floor with all taxes, duties, transportation & requisite testing as per specification & direction of EIC.Make:ASTRAL/ASHIRVAD/FINOLEX
110mm Pushfit Coupler
110mmx87.5º bend
110mmx87.5º door bend
110mmx45º bend
110mm dia Single Tee
110mm dia Single Tee with Door
110mm dia Single 'Y'
110mm dia Single 'Y' with Door
110mm dia Double 'Y'
PVC Clamp Suitable for 110mm dia pipe
110mm dia Vent cowl
110mm Socket plug
Multi floor trap
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-A) For rain water Stacking pipe in the Duct(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as per specification & direction of the Engineer-in-charge. Make:ASTRAL/ASHIRVAD/FINOLEX
110mm dia Bend (87.5 degree)
110mm dia pushfit coupler
110mm dia pipe
110mm dia Bend (87.5 degree) Door bend
Vertical Grating 150x150mm for Rain water gutter on terrace, opening to 110mm dia Rain water pipes
Supplying all materials,labour,T&P and fixing three layer Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701-1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto required height above ground level and placing the tank to the required position and providing flyash brickwork in cement mortar (1:4) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:4) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge.(Make -Sintex/Supreme)(2000 Litres Capacity Triple Layer Tank white)
EXTERNAL PH
Providing all materials, labour, T&P required for construction of RCC M-25 man hole chamber of following sizes having cube strength 200 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm, 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed). PCC 1:3:6 with 40mm size h.g.c.b. metal of 100mm thick, moulding & shaping the channel & benching with C.C. 1:2:4 with 12mm size h.g.c.b. chips, 12mm thick cement plaster 1:3 with cement punning on inner wall surface, earth work excavation in all types of soil/rock including cement concrete cutting as per site condition, filling the foundation base with sand duly watered & rammed, providing, fitting & fixing of pre-cast factory made man hole cover with frame ( heavy duty) for clear opening 560mm dia, providing, fitting & fixing of poly propylene steel reinforced man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical wall with centre to centre 375mm (staggered) etc.all complete as per specification & direction of EIC.
Manhole chamber of Inner size 910mmx910mmx 910mm depth.
Extra for every additional depth of 0.10mtr. or part there of manhole size 910mmx910mmx 910mm upto 1500mm depth.
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. (Excluding cost for earth wok, back filling which will be paid separately).(160mm dia u-pvc pipe alround concrete)
SEPTIC TANK & UGR
Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft.
Supplying and filling sand in foundation and over areas including watering, ramming, consolidating and dressing, labours, tools, taxes etc. all complete as per the specification and direction of Engineer-In-Charge.
Providing and laying plain cement concrete 1:3:6 (1 cement : 3 sand : 6 stone agregate 40mm nominal size) as levelling course in floor and plinth including tempering, curring, shuttering etc. complete all depth and height.
Providing, lifting, hoisting and laying Reinforced cement concrete of M-35 grade as per approved designs and drawings having a minimum compressive strength (in work test) 350Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. (TOP & BOTTOM SLAB OF UGR) (TOP & BOTTOM SLAB ,RCC WALL, BEAM OF SEPTIC TANK)
RCC Wall, Partition Wall & beam of UGR
Cutting, straightening coiled or bent up HYSD Rod or tor steel of SAIL/ TATA / RINL (VIZAG) make including bending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculated basing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement) etc. complete as per specification & direction of Engineer-in-charge.
16mm thick cement plaster (1:6) with standard water proofing compound including punning with cost and conveyance of all materials with all taxes, royalty, labour, labour cess,and T&P required for the work etc. complete as directed by the Engineer-in Charge.
Supplying all materials labour, T&P and fitting and fixing RCPC Cover all compete as per specification and direction of the Engineer in charge. RCPC COVER (24" round)
2.5 cm thick grading concrete (1:2:2) on roof slab with 6.7mm & down grades size hard granite crusher broken chips on new work in Ground Floor 1x8.16x3.16=
BOREWELL
Supplying all materials, labour, tools and plant and setting up boring equipments including erection of suitable staging for installation of the required size of tubewell, dismantling and removing the same after completion of the work, includifng transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc. levelling of site all complete as per direction of Engineer-in-charge
Supplying all labour, tools and plants and transporting boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement bentonite and gravels etc to work sites including loading and unloading etc. complete as per the direction of the Engineer-in-charge
Supplying all labour, tools and plants and drilling pilot bore not less than 102 mm dia without casing pipes in all kinds of soils for the following depths excluding supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per the direction of Engineer-incharge
Supplying all required labour for logging the bore through departmental logging team (till logging team arrives at the site, the contractor is to keep the bore intact by circulating mud through the mud circulating system) and when the logging team arrives at the site, the contractor will withdraw the boring pipe with cutter etc. and keep the bore suitable for loggifng and supply required labour to carry out the logging operation
Supplying all labour, tools land plant and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer-in-charge
Reaming from 100 mm to 150 mm dia, 0 mtr to 300 mtr
Reaming from 150 mm to 200 mm dia, 0 mtr to 300 mtr
Reaming from 200 mm to 250 mm dia, 0 mtr to 30 mtr
Supplying all labour, tools and plant and jointing materials and lowering the 300mm dia top casing pipes into the positioin and removing the same after use all complete as per direction of Engineer-in-Charge.
Supplying all labour, tools and plant and jointing materials and lowering the pvc casing pipes, fittings and well screens in position including fitting and fixing of centraliser, cutter plug and washing the bore etc complete as per direction of Engineer-in-Charge.
100 mm (Sch 80) ASTM pvc pipe including Stainer
150 mm (Sch 80) ASTM pvc pipe
Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 150mm dia pvc Casing pipe {Each bag cement (50 kg) added with 24 ltr of water and 1 to 2 kg bentonite powder will form 40ltrs of slurry (0.021 cum)} including cost of cement & Bentonite powder all complete as per the direction of the Engineer-in-Charge
Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc all complete as per the direction of the Engineer-in-charge (Up to 270 mtr)
Supplying all labour, tools and plant and grouting with cement slurry for sanitary sealing in the bore around the upper most 3 metres of 150 mm dia PVC casing pipe {Each bag cement (50 kg) added with 24 ltr of water and 1 to 2 kg bentonite powder will form 40ltrs of slurry (0.021 cum)} including cost of cement & Bentonite powder all complete as per the direction of the Engineer-in-Chargee
Supplying all labour, tools and plant and materials for cleaning and developing the tubewell with compressor continuously washed till clean and adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour complete in all respect as per the direction of the Engineer-in-Charge
Supply of all labour,Materials & T&P for 100 mm dia C.I plug cutter and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and fixing all jointing materials etc. complete including cost and taxes of materialsas per the direction of the Engineer-in-Charge
Supply of all labour,Materials & T&P for 150 x 100 mm PVC R/S and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and fixing all jointing materials etc. complete including cost and taxes of materialsas per the direction of the Engineer-in-Charge.
Providing and fixing 40mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS 15778,having thermal stability for hot & cold water supply including all CPVC plain & brass threadedfittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer- in-Charge
Supply of 3 phase-3HP, borewell submersible pump-1no (Make-Crompton Greaves) with Submersible pump controller-1no, 6mm (6x19)Stainless Steel Wire rope-40 mtr, 2.5 Sqmm 3 core flat submerisble elctric Cable-50 Mtr and fitted and fixed up perfectly in vertical position & testing including cost, conveyance, taxes of all materials, labour, labour cess,T&P etc. required to complete in all respect as per the direction of the Engineer-in-Charge.
INTERNAL ELECTRIFICATION
Wiring for light point/ fan/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed 2 mm thick PVC conduit with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable including providing modular box with cover of requisite number of modules including providing cover plates as required. Make: Conduit:precision/AKG/BEC/Anchor Wire:KEI/Finolex/Polycab Switch & socket: Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Group-A: L.P= F.P= C.B.P=
Group-B: L.P= F.P= C.B.P=
Group-C: L.P= F.P= C.B.P=
Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing board. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
1 nos 6 Amp 3-pin socket with 6 Amp switch.
2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch.
Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modular socket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. Make:Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying, installation, testing & commissioning of 25 amp modular socket outlet on surface or in recess, on 1 Nos two module GI box with 25A Starte motor . complete as direction of Engineer-in-charge.Switch & socket: Legrand(Myirus)/schneider-Zenclo/Simens(Marq)
Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required. Make-KEI/Finolex/Polycab
2 x 1.5 sq.mm + 1 x 1.5 sq.mm (for Light loop/group circuit wiring)
2 x 2.5 sq.mm + 1 x 1.5 sq.mm (for Light plug circuit wiring)
2 x 4 sq.mm + 1 x 1.5 sq.mm (For power circuit)
2 x 6 sq.mm + 1 x 4 sq.mm(For SPN DB & AC POINT)
4 x 6 sq.mm + 2 x 4 sq.mm (For TPN DB)
4 x 10sq.mm + 2 x 4 sq.mm (For TPN DB)
Supplying of recess/surface mounted 2'x2' 36W (595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Bajaj /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years.
Supplying of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make-Wipro/Philips/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make-Wipro/Philips/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supplying of Energy efficient surface /recess mounted square /round shape 9 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 9 watt and lumen output of 900 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge.(Make-Wipro/Philips/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying of surface Mounted Led bulk head Lighter comprising of 10W LED BULK HEAD LIGHTwith non integral / integral driver, 6500K color temp having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 120 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc. to complete the job. (Make-Wipro/Philips/Baja)
Supplying of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Crompton/ Orient/ Havells/Polycab).(1200 mm sweep)
Supplying of Exhaust fan / fresh air fan with louvre as required.(Make : Crompton/ Orient/ Havells/Polycab).
Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers(Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
MCB, DB and PANELS
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ ABB ITUS/LK -Exora as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
6 way(8+18), Double door, ETPN DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supply and fixing of 6 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required Make :-ABB/LK/Legrand
40 Amps2P,30mA, RCBO
40 Amps 2P RCCB
6A/32A SPMCBs(C-Curve)
Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supply and laying of 25/32mm U PVC trunking system and acessories.(Make:Legrand/MK(honeywell)
Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent/other LED fitting of all sizes complete with all accessories and tube etc. directly on ceiling wall, including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.
Installation, Testing and Commissioning of ceiling , including wiring the down rods of standard length (upto 30 cm) and wall mounted fan with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.
Installation, testing and commissioning of exhaust fan up to 200 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.
Providing and fixing extra down rod of 20 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.
FIRE EXTINGUISHER SYSTEM
Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket . (Make: supremax/Cease fire/Minimax)
Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. (Make: supremax/Cease fire/Minimax)
Supplying, installation, testing and commissioning of Mechanical Foam type 9 litre capacity Fire Extinguisher, ISI marked, IS: 10204, containing 540 ml AFFF liquid ISI marked, IS: 4989 Part II and a polyurethane coated CO2 Gas Cartridge, ISI marked, IS: 4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket.(Make: supremax/Cease fire/Minimax)
Supplying of Fire buckets ( WITHOUT SAND) round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket.
Supplying of First Aid Box.
AIR TERMINAL
Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts . Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ). (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp tested upto 100KA lightning current . (Make:OBO/ABB/ DHEN).
DOWN CONDUCTOR
Supply , Installation, Testing & commissioning of 8 mm Aluminum Round Conductor. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Ring & vertical earthing system
Supply , Installation, Testing & commissioning of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of universal clamp made of SS to connect rod with flat conductor (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested (Make:OBO/ABB/ DHEN).
Supply , Installation, Testing & commissioning of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system (Make:OBO/ABB/ DHEN).
Installation of The above arrangements including all accessories as per Direction of Engg. In charge.
REFRIGRANT PIPING
LT PANEL
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD 25 kA 20X10MM Separate Aluminium Earth bus bar should be installed.Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Busbar -125A AL busbar with SC rating of 25KA Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator.
125A FP Automanual Changeover (supply from EB & Future DG supply as required) with other accessories as required.
Incomer feeder consisting of
Two (2) 100 Amp Moulded Case Circuit Breaker, 4P, Breaking capacity – 25 KA breaking capacity as mentioned in the BOQ with Therma Magnet Based Release with Ics=100% Icu with 3 NosIndicating lamp for ON/OFF/Trip with control fuse/ MCB, 3 Nos 100A/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F) Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Six(6) - Outgoing Feeders : 01 Nos for PHE Panel, 2 nos per External Lighting Feeder Panel & 02 Nos Spare each comprising of63Amp,4p,MCB,C-CURVE Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
Twelve(12) - Outgoing Feeders :04 Nos for LDB , 4no AC+PDB, 1 no Pump house L+PDB & 03 nos Spares each comprising of 40Amp,4p,MCB,C-CURVE Make-Schneider(CVS)/Legrand(DPX3)/Siemens(3VA)/ABB(Formula)
PANEL AS ABOVE
EARTHING
Earthing with GI earth pipe 3m long 40mm dia ISI marked including all accessories and providing masonary enclouser with cover plate having locking arrangement and watering pipe etc. with charcoal & salt as required as per the direction of Engineer-in-charge.
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required.
Providing and fixing 8 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
Cable Supply
Supplying & Testing of 1.1 KV grade Aluminium XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply.
3.5C X 50 sqmm Al
4C X 10 sqmm
CABLE LAYING
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size in the existing RCC/HUME/STONEWARE/METAL pipe as required.
Above 25 sqmm and upto120 sqmm
upto 25 Sqmm
Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. Upto 25 Sqmm
TERMINATION OF CABLES :-
Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable)
3.5C X 50 sqmm Al
4CX 10 sqmm
Providing,fixing and laying of fallowing dia PN16 HDPE pipe 63mm(medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
SITC of HT Rubber mat 1m X 2m & SITC of Shock treatment chart.
EXTERNAL ELECTRIFICATION
Single Arm Street Lights:
Supply, erection, testing & commissioning of road lighting HDG Octagonal Pole conforming to IS 875 and BS EN ISO 1461 & 410 SP 33 of 7.0 meter with base plate drilling of 1" dia hole on the upper portion of the pole for the installtion of street light and 1" dia hole on the lower portion of the pole for entry of the wire Base pole paintng of red oxide and two coats of black enamel paint. The poles shall have extra provided and fixed with 4'x2' dia being erected by laying 5'x2'x2' (length, breadth and width) cement concrete block in the ratio 1:3:6 and block be continued up to 1 feet above the ground level i.e 4 feet below ground level including surface plastering the job including excavation of pole with 4 feet deep and refilling the same after installation of the pole and with holes at top of the pole for fixing ring type single armed GI braket for the installation of the integral flood light luminaire of 72 watt (Make : Bajaj Cat no: ZELA P 86L WH PO TG SD or equivalent of CG, Unilux ). The Dust and wheather proof gasket using for 250mmx200mmx150mm deep box nominal size of 16 SWG thick MS sheet cable looping box with the existing pole with MS clamp made out of 25mmx3mm thick flat iron with suitable nuts and bolts complete with hinged cover and locking screws earth studs neoprene gasket suitable for Nos 4 pole mounted including supply and fixing one no 6 Amp MCB carrier with base and 4 way 60 Amp terminal block suitable to receive PVC armoured cable fixed on suitable size Baketillte sheet base complete connection through GI pipe (classB) 40 mm dia Nominal 1.5 mtr length along the pole or protection of underground cable (on vertical run) with painting all complete as the direction of EIC.
EXTERNAL FEEDERE PILLER
Supply, installation, testing and commissioning of cubicle type sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base channel, complete with all accessories including interconnections, earth bus etc as required. Make-L&T/Schneider/ABB/Legrand Busbar -100AL busbar with SC rating of 25KA suitable for operation at 415 Volt, 50 HZ , 3 phase Supply.
(a) Busbar -100AL busbar with SC rating of 25KA suitable for operation at 415 Volt, 50 HZ , 3 phase Supply. One (1) - 63 Amp, 25 KA, 4P MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos 100/5 A 15VA Cl 1.0 CTs, 1No - Multifunction meter (V,A,KWHr, KW, P, F) with suitable digital timer. (b) 1 Nos - 40 Amp 4P MCB Outgoing 5 Nos - 16 Amp SP MCB Outgoing 1 No - 16 Amp SP MCB with 6/16 Amp socket outlet with 10 Amp modular switch and 1 No- Bracket Holder with 6 Amp Modular switch.
PANEL AS ABOVE
CABLE SUPPLY
Supplying & Testing of 1.1 KV grade Aluminium XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. MAKE:KEI/RR Kable/Havells/Polycab
3.5C X 35 sqmm Al
4C X 16 sqmm Al
Cable Supply
Supplying & Testing of 1.1 KV grade Aluminium XLPE armoured power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. MAKE:KEI/RR Kable/Havells/Polycab
Above 25 sqmm and upto120 sqmm
upto 25 Sqmm
TERMINATION OF CABLES :-
Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable),MAKE:Dowells/Comet/Jainson.
3.5C X 35 sqmm
4CX 16 sqmm
Supply and laying of 60MM Dia HDPE Pipe with sol Excavation & Refilling as per the direction of EIC.
Supply, Exivation & Refilling of HUME Pipe, 150MM Dia(NP-4)
SOLAR POWER SUPPLY WORKS
Supply, Installation & Commissioning of 7.5 KVA Off Grid Rooftop Solar PV power Plant with Mounting Structure
Supply of Solar PV panel (545 wp mono perc (Grade 1))
Supply of Battery (Exide c-10 Super 200 Ah)
Supply of PV Inverter (7.5 KVA)
Supply of Mounting Structure for 8 KW (Gl standard grade)
Supply of Electrical components (Havells/Reputed make)
Supply of Lightning arrestor (Copper based high grade)
Installation & commissioning
Electrical wiring & charging point
Transportation etc.
SITC of 2.5 kw Submersible water pump with suitable DOL starter, 3 Ph Flat submersible cable and earthing as required single stage single entry pumps connected to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical. discharge pipe, in built level controller with operational moded as one pump working at low level, pumps at high level with a hooter alarm and cut off at dry level as determined. The pump shall be provided with a lifting devise of pull chain/guide rail & G.I. heavy class rising main of required length cable etc. as per requirement complete in all respects.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
BOQ_581961.xls
BOQ • 0.86 MB
DTCN.pdf
Tender Documents • 6.53 MB
Download all tender documents and submit your bid