Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
25 Apr 2022, 11:00 amClosed
Chief Engineer Project Shivalik
HQ CE (P) Shivalik, IDPL Complex, Virbhadra, Rishikesh-249202
Repair, Replacement of Internal Fitting and Fixture of E and M Works for HQ DGBR Complex (Seema Sadak Bhawan), Ring Road, Delhi Cantt in the area of 1353 GE /21 BRTF under Project Shivalik in New Delhi (Retender)
2022_BRO_516725_1
80260/Bldg Maint/EM Wks/DGBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
HQ DGBR Complex, Ring Road, Delhi Cantt
As per tender documents
8 documents required · 8 mandatory
₹0
₹86,000
Yes
18 Jun 2022
5 Apr 2022
26 Apr 2022
5 Apr 2022
25 Apr 2022
14 Apr 2022
6 Apr 2022 - 13 Apr 2022
Amount
Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) complete such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing complete all as specified and directed.
M&L for point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable(phaseneutral and earth wire)in and including surface PVC Casing Capping ISI marked of suitable size medium grade with PVC fittings such as tees, bends, elbow, reducers etc. earth wire, connecting to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing modular switches/sockets etc with modular type cover plate 3mm thick plastic laminated sheet for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as specified and directed. Note : The cost of Metal boxes including concealed in wall and moduler cover plates etc will be included in quoted rate.
All as per item no. 2 here-in-before but for one socket outet point 5 amps on the same board complete all as specified and directed.
All as per item no. 2 here-in-before but for one socket outet point 5 amps on the independent board complete all as specified and directed.
All as per item no. 2 here-in-before but for one light point controlled by two nos of 2 way switch complete all as specified and directed.
All as per item no. 2 here-in-before but with 3x 2.5 sq mm (Nominal area) FRLS PVC insulated unseathed and stranded copper wire conductor cable (phase ,neutral and earth wire) for 15 Amp power point complete all as specified and directed.
M&L for concealed point wiring with 3x1.5 Sq mm (nominal area) FRLS PVC insulated un-sheathed and stranded copper conductor cable(phaseneutral and earth wire)in and including PVC concealed conduit ISI marked of suitable size medium grade with PVC conduit fittings such as tees, bends, elbow, reducers including cutting chasing and making good to disturbed surface , earth wire, connecting to common earth dolly with and including pressed steel sheet Metal sunken box of suitable size for fixing modular switches/sockets etc with modular type cover plate 3mm thick plastic laminated sheet for one light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push complete all as specified and directed. Note : The cost of cutting chasing for concealed wiring in wall /floor and including Metal boxes concealed in wall and modular cover plates etc will be included in quoted rate.
All as per item no. 7 here-in-before but for one socket outlet point 5 amps on the same board complete all as specified and directed.
All as per item no. 7 here-in-before but for one socket outlet point 5 amps on the independent board complete all as specified and directed.
All as per item no. 7 here-in-before but with 3x 2.5 sq mm (Nominal area) FRLS PVC insulated unseathed and stranded copper wire conductor cable (phase ,neutral and earth wire) for 15 Amp power point complete all as specified and directed.
S & F in repair Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed.
S &F in repair Modular switch 6 Amp, 2 way, 1 module size complete all as specified and directed.
S & F in repair Modular switch 16 Amp, 1 way, 1 module size with indicator lamp complete all as specified and directed.
S&F in repair bell push, Modular type, 5 Amps complete all as specified and directed.
S&F in repair Bell, AC 230 Volts, single pole complete all as specified and directed.
S &F in repair modular socket two-in-one, 6 Amp universal type, 02 module size complete all as specified and directed.
S & F in repair modular Socket, 16 Amp, multipurpose shutter type, 02 module size complete all as specified and directed.
S & F in repair Modular Fan regulator step type, 120 watts, 2 Module , 5 step complete all as specified and directed.
S&F in repair lamp holder insulated body and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed.
S&F in repair Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified and directed.
Taking down of celling fan and exhaust fan and Hanging /Re-fixing connecting up after repair including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
M&L for rewinding of ceiling fans 1200mm /1400mm of any type and make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including replacement of ball bearing as requirement of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep complete all as specified and directed.
M&L for rewinding of exhaust fan / ventilating fan /circular fan of 300mm / 250mm sweep of any type & make complete with super enamelled copper wire (HTP) including taking out old wind copper wire with appropriate gauge &quantity, both sides of rewinding locked with high quantity varnish complete inclusion of ball bearing of SKF/NBC make and provisions of new nuts pin all as specified & directed.
M&L for painting of ceiling fans 1200mm/1400m complete in situ with synthetic enamel paint of white colour by spraying including filling cavities with filler ,one coat after cleaning all dust etc complete all as specified and directed
Supply and fixing replacement of capacitator 2.50/3.15 Mfd, 240 V complete all as specified and directed.
Supply & fix celling fan blades(03Nos 1 set) for 1200/1400 mm sweep ceiling fans complete all as specified and directed.
Supply and fixing in repair of inner shell of steel body suitable for 25Ltrs capacity of geyser including taking down, descaling, replacement of Gasket and any other minor repair for geyser made serviceable and testing complete all as directed by Engr-in-Charge as per existing pattern complete all as specified and directed.
S& F in repair copper heating element 1500 watt embedded copper, sheathed tubular with theremostat casing cap triangular/Round type of IS : 4159 complete all as specified and directed
S&F in replacement thermostat suitable for Geyser capacity 25Ltr water temperature 30° to 75° C electric cut up for any type of water heater complete all as specified and directed.
S & F in replacement copper flange assembly suitable for 25 ltrs capacity water storage heater (geyser) with nut & bolt as per site requirement complete all as specified and directed.
Supply and fixing in replacement outer body dully powder coated by white paint suitable for water heater 25Ltrs capacity of geyser including taking down old one , replacement of Gasket and any other minor repair for geyser made serviceable and testing complete all as directed by Engr-in-Charge.
S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply and fixing PVC Connection 600 mm long complete all as specified and directed.
S & F in repair Flush/ surface mounted neon indicator lamp in colours red and green complete all as specified and directed
S & F in repair Glass wool for geyser insulation complete all as specified and directed.
S & F in repair Air reliese valve for water Heater complete all as specified and directed.
S&F in repair of non return brass valve 15mm bore complete all as specified and directed.
S&F in repair of EPDM gasket complete all as specified and directed.
Supply and fixing in replacement of solar panel collector complete all as specified and directed.Make: Supremen or equivalent as approved.
S&F in repair of hose pipe 25 mm dia& 18" long complete all as specified and directed.
S&F in repair of sacrificial and complete all as specified and directed.
Supply and laying in repair CPVC pipe of 25 mm outer dia including fittings & taking down old pipe +complete all as specified and directed.
S & F in repair copper Heating element 3KW for solar water heater embeded copper sheathed tubular with casing cap triangular/round shape.
S&F in repair of factory made epoxy polyester powder coated distribution board 8 way SPN DB-507611 fabricated from minimum 1.2 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB all as specified and directed. NOTE (a) MCBs SP ,SPN shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed fit included in item rate
Supply & Fix in repair factory made epoxy polyester powder coated distribution board 4 way VTPN DB-507745 with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incomer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE: - (a) MCCB /MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed fit included in item rate
Checking and attending complaints with one electrician and one helper in HQ DGBR office Complex and JCOs /ORs OTM Accn complex area inNarayna means of repairing/rectifying the electric defects/faults related to electricalequipment’s ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : 1 The electrician deployed by the contractor shall have ITI /03 years experience certificate in concerned trade.Helper deployed shall be min 8th pass with min 03 years experience in relevant trade.2. This item covers only cost of labour for attending complaint and taking down of old material. 3. Item to be replaced under this item shall be either issued free for fixing under schedule 'B'or shall be contractor supply under respective items of this schedule as decided by Engineer-in -charge. Decided of GE in this regard shale be found and bonding.4. Complaints noted'' NO Light'' shall be attended immediately up to 2200 hrs without fail, failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill.5. Minor items as PVC wire of any size as per requirement up to 1.0m length, thimble,electric tape etc shall deemed to be included in the quoted rate of this items.6.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed on the contractor and recovery shall be made from his dues.7. Contractor shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed.8. Contractor or his rep will report daily at complaint cell for collection of complaints fromthe concerned JE's in charge,in case after checking& attending the defects, if it is not possible to rectify the defects within 08 hrs, the facts shall be brought to the notice of Engineer in charge by the contractor/his rep immediately. If Engr -in -charge is satisfied with contractor's view, no recovery will be made on this account.9.Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ.
S&F in replacement MCCB, 415 volts, four pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in replacement MCCB, 415 volts, four pole of cap 63 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in replacement MCCB, 415 volts, four pole of cap 125 Amps, 25 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in replacement MCCB, 415 volts, four pole of cap 200 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in replacement MCCB, 415 volts, four pole of cap 250 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in replacement MCCB, 415 volts, four pole of cap 400 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader teRunning Materials / thimble of suitable size and making connections complete all as specified and directed.
S&F in repair metal clad sockets 2 pole + earth rating 20 amps 250 volt complete all as specified and directed.
S&F in repair MCB 6 to 32 amp, SP ,240 v, 50 Hz AC ,10KA complete all as specified and directed.
S&F in repair MCB ,SPN 6 to 32 amp ,240 v, 50 Hz AC ,10KA complete all as specified and directed.
S&F in replacement MCB DP,40 amp, 240 v, 50 Hz AC ,10 KA complete all as specified and directed.
S&F in replacement MCB DP ,63 amp, 240 v, 50 Hz AC ,10 KA complete all as specified and directed.
S&F in replacement MCB TPN 63 Amps, 240 v, 50 Hz AC ,10 KA terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 complete all as specified and directed.
Checking and attending complaints with one electrician and one helper in JCOs and ORs Married Accn in Behindbuchary area by means of repairing/rectifying the electric defects/faults related to electricalequipment’s ,devices,accessories and fixtures maintained by MES .Tightening the loose connections complete all as specified and directed. Note : 1 The electrician deployed by the contractor shall have ITI /03 years experience certificate in concerned trade.Helper deployed shall be min 8th pass with min 03 years experience in relevant trade.2. This item covers only cost of labour for attending complaint and taking down of old material. 3. Item to be replaced under this item shall be either issued free for fixing under schedule 'B'or shall be contractor supply under respective items of this schedule as decided by Enge-in -charge.Decided of GE in this regard shale be found and bonding.4. Complaints noted'' NO Light'' shall be attended immediately up to 2200 hrs without fail, failing which recovery of Rs.240/ per complaint shall be effected from the RARs/ F Bill.5. Minor items as PVC wire of any size as per requirement up to 1.0m length,thimble,electric tape etc shall deemed to be included in the quoted rate of this items.6.The complaints shall be attended & defects shall be rectified within 08 hrs commencing from date and time of notifying the complaint slip failing which a penalty @ Rs.120 per complaint per day shall be levied/imposed on the contractor and recovery shall be made from his dues.7. Contractor shall arrange suitable T&P incl necessary from work and scaffolding and safety measures to make it functional complete all as specified and directed.8. Contractor or his rep will report daily at complaint cell for collection of complaints fromthe concerned JE's in charge,in case after checking& attending the defects, if it is not possible to rectfy the defects within 08 hrs, the facts shall be brought to the notice of Engineer in charge by the contractor/his rep immediately. If Engr -in -charge is satisfied with contractor's view, no recovery will be made on this account.9.Labour charges for this item shall not be included under items which includes 'M&L','S&F' in repair',fixing only /Fixing in repair etc in respective item of this Schedule/BOQ.
Supply only PVC wire copper conductor unsheathed stranded nominal cross sectional area 1.5 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed.Make :- Havells /Finolex/Kalinga /polycab.
Supply only PVC wire copper conductor unsheathed stranded nominal cross sectional area 2.5 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed.Make :- Havells /Finolex/Kalinga /polycab.
Supply only PVC wire copper conductor unsheathed stranded nominal cross sectional area 4.0 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed.Make :- Havells /Finolex/Kalinga /polycab.
Supply only PVC wire copper conductor unsheathed stranded nominal cross sectional area 6.0 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed.Make :- Havells /Finolex/Kalinga /polycab.
Supply only PVC wire copper conductor unsheathed stranded nominal cross sectional area 10 Sqmm single core LT 1100 Volt grade cable complete all as specified and directed.Make :- Havells /Finolex/Kalinga /polycab.
Supply only 9 Watt LED Bulbs, high energy efficiency LED luminaire with lumen output of 800-900 lumens , Make : Havells /Jaquar/Philips / Crompton Greaves.
S & F in repar Endura Rugby Neon IP65 Bulkhead light fitting 10 watt LED type with complete all accessories including connecting up with three core twisted flexible cable. Make - Havells /Jaquar/Philips / Crompton Greaves.
S & F in repair Mirror light 02 fit Linnet reflectionwithout shadows complete all as specified and directed Make : Havells /Jaquar/Philips / Crompton Greaves.
S &F in repair surface and walll mounted (2 fit ) LED betten 10W light extended aluminium houseing provided for efficient heat disipation with polycarbonate diffuser &intigrated with electronic driver 10W with 2fit LED tube Rod complete Make :- Havells /Jaquar/Philips / Crompton Greaves.
S & F in repair LED Regal Batten (4ft) for LED tube light complete fitting 1x22Watt universal batten suitable for use with single LED tube Cat part no. REGALBATTEN8UPTO 1X22WSSBSWH. Make : Havells /Jaquar/Philips / Crompton Greaves.
S &F in repair LED Regal Batten (4ft) for LED light complete fitting 2x22Watt batten suitable for use with single LED tube . Make : Havells /Jaquar/Philips / Crompton Greaves.
S&F in repair LED tube light 20W suited for installation in existing T8 betten, extruded aluminium heat sink provided for efficient heat dissipation & integrated 20W LED 6000K (4 ft) LED Tube Rod complete all as specified and directed.Make : Havells /Jaquar/Philips / Crompton Greaves.
S&F in repair LED PLUTO NEO (High Lumen) FLAT PANEL 2x2 fit 34 Watt LED 6000K Ultra modern compact surface luminaire suitable for armstrong/ grid/ POP ceiling complete with electronic driver & high brightness SMD LEDs fixure of size 595x595mm complete all as specified and directed.Make : Havells /Jaquar/Philips / Crompton Greaves.
S & F in repair 18W LED Surface mounted downlight with white powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete all as specified and directed.Make : Havells /Polycab /Jaquar/Philips .
S& F in repair New generation Post Top Lantern ,energy saving environmental frindly, long life aesthetically designed with semetrical light distribution, spum aluminium landscape luminaire with high power LEDs as light source Cat Part No CORALPT 25W LED 757PSYMTOPC Make : Havells /Polycab / Philips / Crompton Greaves.
Supply only Ventilating Fan Maxima DXI 200 mm white DOM 230v AC,50Hz plastic body including self cosing louver and making all electric connections complete all as directed.Make : Havells / Bajaj / Crompton Greaves.
Supply only Switch socket combination 6/16 A 250V AC universal with box in polycarbonate.
Supply only switch piano flush button type 5 amps single pole one way
Supply only switch piano flush button type 15 amps single pole one way
Supply only socket outlet multipurpose 2/3 pin 5 amps flush button type
Supply only socket outlet multipurpose 2 in 1, 5 and 15 Amps
Supply only ceiling fan regulator 5 step type .
Supply only Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, Make : Legrand /Havells /Indo Asian
Supply Only Flexi LED Strip Light warm type 5 Watt /Mtr 5mtr Roll Make: SYSKA Cat Part No SSK-ST-8060-EX-D ,or equivalent of Halonix,,Bajaj,Havells.
Supply only LED Down light Round 5 Watt(Clear Lens)Make: SYSKA, Cat Part No: SSK LNTH 201 B ,Halonix,Bajaj,Havells
Supply only LED Panel light Round 8 Watt white Make: SYSKA, Cat Part No: SSK PA 2344E ,Halonix,Bajaj,Havells.
supply only LED Down light warm (SMD) 12 Watt Make: SYSKA, Cat Part No: SSK-DLS- 4" 12W ,Halonix,,Bajaj,Havells.
Supply only Aesthetically designed energy saving LED 10W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K .Make - Polycab , Cat. Part No. LD00112001 ,Havells,SYSKA ,Philips ,
Supply only LED Panel light Round 8 Watt warm 3000K Make: Havells,Cat Part No: LHEEBPP51LIW008 ,or equivalent of Halonix,,Bajaj,Philips
Supply only Aesthetically desined energy saving LED 18W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K .Make - Polycab , Cat. Part No. LD00112003 , ,Havells,SYSKA ,Philips ,
Supply only Aesthetically designed energy saving LED 22W wall light / Surface fitting white powder coated CRCA housing and PMMA dome diffuser,6000K .Make - Polycab , Cat. Part No. LD00112004,or equivalent of Halonix,Havells,Philips
Supply only 4 way extension Board 4 universal socket outlet+1switch/indicator /cord length 1.5meter Cat part No. SAC0100001 Make: Polycab or equivalent of Havells/Anchor /Bajaj
Supply only twin core flexible, PVC insulated, unsheathed, multi-stranded copper conductor wire of size 24x0.0076, complete all as directed. Make : Kalinga/Havells/Polycab./finolex
Supply only lamp holder insulated body and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed. Make: Anchor /SSK/Legrand
Supply only PVC casing & capping 20mm size with fitting material for existing disturbed wiring etc at various locations as directed and making good surfaces, match existing etc complete all specified.
AKANSHA CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .