Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹22.0 L+₹1.1 L (5.11%)Rejected-Finance | L2 | Rejected-Finance Rejected Being L2 | |
| 3 | L3₹22.6 L+₹1.7 L (8.00%)Rejected-Finance PLOT NO 361 FLAT NO 06 FIRST FLOOR SECTOR 11 HIRAN MAGRI UDAIPUR 313001 RAJ | UDAIPUR | UDAIPUR | RAJASTHAN | 313001 | L3 | Rejected-Finance Rejected Being L3 | |
| 4 | L4₹28.1 L+₹7.1 L (34.2%)Rejected-Finance | L4 | Rejected-Finance Rejected Being L4 | |
| 5 | L5₹30.3 L+₹9.4 L (45.2%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L5 | Rejected-Finance Rejected Being L5 |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
31 Mar 2021, 6:00 pmClosed
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
REPAIR AND MAINT OF WINDOW SPLIT AND DUCTABLE TYPE ACS AND REPAIR AND MAINTENANCE OF DESERT COOLERS UNDER AGE EM IN ARMY AREA UNDER GE ARMY CENTRAL JODHPUR (9005/E8)
2021_MES_429517_1
GE/J/A- OF2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (A) Central Jodhpur
₹46,000
19 Apr 2021
10 Mar 2021
2 Apr 2021
10 Mar 2021
31 Mar 2021
17 Mar 2021
Amount
M&L for checking of window type air conditioner of any make/capacity (1.5/2 TR ) in location and position at any site in Army Area Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality, testing for proper functioning of window type air conditioner in situ all as directed by Engr-in-Charge.(The rates quoted are deemed to be included for maintaining complete and proper record of machine ie Make with cap and location , date of servicing, user signature after servicing, concerned JEs signature duly verified by the Engr-in-Charge) Note : (a) Cleaning and decaling of condensing unit and cooling coil with caustic soda mixed water and air blower and sludge etc. all as directed by Engr-in-Charge.(b) Greasing/oiling of blower fan motor.including charging of gas if reqd and cost of gas will be paid seperately under respective item of BOQ, complete all as specified and as directed.
M&L checking of split type air conditioner indoor unit of any make and capacity (1.5/2 TR ) in location and position at any site in Army Area unit Jodhpur including necessary servicing .ie. electrical connection/wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil, replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner all as directed by Engr-in-Charge.(The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with cap and location , date of servicing , user signature after servicing , concerned JEs signature duly verified by the Engr- in-Charge.(b) Greasing /oiling of blower fan mator including charging gas if reqd and cost of gas will be paid seperately under respective item of BOQ, complete all as specified and as directed.
M&L for disconnecting, existing u/s sealed unit and replacement with new rotery type sealed reciprocating conventional compressure cap 1.5 ton ( for Window type ACs) , including pressuring system checking for leakage in system and flush out the system etc complete ; Make : kirloskar/Tecomusha Note: Gas charging etc shall be measured and paid separately under relevant item of BOQ complete all as specified and as directed.
M&L for disconnecting, existing u/s sealed unit and replacement with new rotery type sealed rotary type as per existing compressure cap 1.5/2.0 ton ( Split AC) including pressuring system checking of leakage in system and flush out the system etc complete .,make : kirloskar/Tecomusha. Note: Gas charging etc shall be measured and paid separately under relevant item of BOQ, complete all as specified and as directed.
Material and labour for rewinding of blower motor (speed 900 RPM) of window/Split Air conditioner of cap. 1/5 HP any make with super enamelled copper conductor winding wire including replacement of worn out bushes, shaft and capacitor etc and testing complete, complete all as specified and as directed. Make of winding wire : Atlas/Chetak/Devidayal).
All as per above item No 5 above but 45 /50 Mfd 240 Volts, 50 cycles for window type/ Split Type AC 1.5/2.0 Ton Cap. (Make : EPCOS/KELTRON/SIEMENS/SHARDA )
Supply and fixing over load protection with relay No 1622/2085 (Make : Shri Ram/Renutrol/Annapurna) for 1.5 Ton cap. For split/ window type AC, complete all as specified and as directed.
Supply and fixing over load protection with relay No 1062 (Make : Shri Ram/Renutrol) for split/window type AC, for 2.00 Ton Cap, complete all as specified and as directed. (Make : Annapurna/Indofoss No 2059/Ranutrol)
Material and labour for replacement of thermostatic switch for window type AC cap. 1.5/2.00 Ton Capacity, complete all as specified and as directed. (Make : Anupurna/Indofost No 2059/Ranutrol)
Material and labour for pressurising complete system , checking leakage and flushing out system , rectification of leakages if any and including gas charging using refrigerant M- 404/444/R-22 oil charging complete in compressor window type AC1.5/ 2 Ton all as directed & with entire satisfaction of Engr-in-Charge (Note :(i) The work is to be carried out in existing location and position. (ii)Cost of Gas will be paid separately under respective item of Schedule 'A'. )
All as per above item No 10 above but for Split AC 1.5/2 TR cap.any make in existing position and location etc, complete all as specified and as directed.
Material and labour for replacement of cooling coil for window type AC Cap. 1.5/2.0 TR as per existing, complete all as specified and as directed.
Material and labour for replacement of blade of condensor fan motor (as per sample) for window type AC cap 2 Ton, complete all as specified and as directed. (Make: AUE/EQUIVALENT ISI marked)
All as per above item No.13 above but for 1.5 Tonn cap AC, complete all as specified and as directed.
Material and labour for replacement of blower for AC cap. 1.5/2.0 Ton (as per sample), complete all as specified and as directed.
Material and labour for painting to outer cover split type AC unit of any cap and make with two coats of synthetic enamelled paint of approved colour as directed , complete incl. Cleaning and removing of rust filling putty etc complete.etc. all as directed by Engr-in-Charge.
Capacitor 2.5 MFD PTC Type, complete all as specified and as directed. (Make : EPCOS/KELTRON/SIEMENS/SHARDA )
M&L for taking out and refixing split type ACs any cap/Make from one location to another location including pressurising the system ,testing and leakage rectification in system , making good disturbed surfaces and testing all as directed by Engr-in-Charge. Note :- Rates are deemed to included for making holes for suction , discharge pipe and condensed water pipe (ii ) extra lenth of copper pipe duly insulated and gas if required shall be paid seperately .
Material and labour for replacement of digital type thermostat as per existing of walk in cooler, complete all as specified and as directed.
Material and labour for replacement of sub main wiring two run of PVC insulated,1100 volts grade ,FRLS, single core 6 sq mm (Nominal area) multistranded copper conductor cable including one 6 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dia rigid PVC conduit ISI marked complete including accessories , junction boxes with sheet top cover and other accessories complete all as directed by Engr-in-Charge. NOTE : Two run of 6 Sq mm and one run of 6 Sq mm as earth wire and pipe shall be measured as one length, complete all as specified and as directed. (Make of cable/PVC Pipe :- Polycab/ finolex/Havels ISI marked)
Material and labour for replacement of sub main wiring two run of PVC insulated,1100 volts grade ,FRLS, single core4 sq mm (Nominal area) multistranded copper conductor cable including one 4 Sq mm solid copper conductor PVC insulated cable in and including 20 mm dia rigid PVC conduit ISI marked complete including accessories , junction boxes with sheet top cover and other accessories complete all as directed by Engr-in-Charge. NOTE : Two run of 4 Sq mm and one run of4 Sq mm as earth wire and pipe shall be measured as one length, complete all as specified and as directed. (Make of cable/PVC Pipe :- Polycab/ finolex/Havels ISI marked)
Supply and replacing single pole and neutral enclosure with 2 pin earth plug ad socket complete with one MCB SP 25 Amps, complete all as specified and as directed. (Make -Legrand/Havells) as in replacement.
Material and labour for replacement of cord less remote with control panel suitable for split type AC Cap 1.5/2.0 Ton. Note : Make of remote shall be all as per existing, complete all as specified and as directed.
Material and labour for replacement of Swing motor of split type AC cap 1.5/2.0 Ton with flapper complete all as directed by Engr-in-Charge.
Material and labour for replacement of PVC condensed water drain pipe 15 mm dia for split type AC complete including providing saddle with clamping arrangement all as directed by Engr-in-Charge and
Material and labour for replacement of copper discharge tube of size 3/8" duly nylon insulated all as specified by Engineer -in-Charge.
Material and labour for replacement of copper suction tube of size 5/8" duly nylon insulated all as specified by Engineer -in-Charge.
Supply and fixing blower motor of indoor unit for 1.5 TON cap split type AC (Make Blue star/Voltas complete as per sample) as in replacement, complete all as specified and as directed.
Supply and fixing of indoor unit for 1.5 TON cap split type AC (Make : Blue star/Voltas complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replace auxillary supply PCB for indoor unit of split type Acs 1.5/2.0TON capacity of any make and model as oer sample, complete all as specified and as directed.
M&L for repairing secondary PCB for indoor/outdoor unit of Three phase/ split type Acs any capacity , complete all as specified and as directed. make , including replacement of programming IC , transformer , condensor , zener , diode , resistance etc.
All as per above item No. 31 above but PCB of single Phase AC of any cap and make all as directed by Engineer -IN-Charge.
Supply and fix heavy duty bracket powder coated suitable for out door unit split Acs , including steel fastner - 4 Nos, complete all as specified and as directed.
M&L for providing nylon insulation on discharge and suction pipe of split unit ACs in existing location and position including . NOTE: Rates are deemed to be measured as single length for one suction and discharge, complete all as specified and as directed.
Supply and replace single phase contactor for outdoor unit of split type Acs any capacity (!.5/2 TR), complete all as specified and as directed.
M&L checking of split type three phase air conditioner of any make / capacity 7.5/5.5/3.0 in location and position at any site in AA Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning condenser, blower fan motor servicing including replacement of both end bushes of approved quality cleaning cooling coil ,replacement of micro filter of approved quality and testing for proper functioning of split type air conditioner all as directed by Engr-in-Charge.( The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with Cap and Location., date of servicing , user signature after servicing , concerned JEs signature all as directed by engineer incharge ) (Note : The work is to be carried out in war centre existing location and position. ) , complete all as specified and as directed.
Material and labour for ,pressurising complete system of split type three phase air conditioner, checking leakage and flushing out system , rectification of leakages if any and including gas charging using refrigerant M- 404/444/R-22 oil charging complete in compressor /Split type AC cap.7.5/5.5/3 Ton all as directed & with entire satisfaction of Engr-in-Charge (Note : The work is to be carried out in war centre existing location and position. (ii)Cost of Gas will be paid under separately under Schedule 'A' ) , complete all as specified and as directed.
M&L for disconnecting, existing U/S sealed unit and replacement with new three phase hermatic sealed rotary compressure cap -4/4.25 ton ( for split type ACs) ,make : HITACHI Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A', complete all as specified and as directed.
Supply only refrigerant gas M- 404/444/R22, Make:Maffron/Floron ( Note : (i) The gas is to be supplied in cylinder duly sealed by manufacturer/ factory sealed with proper PVs and other documents .
Supply and replacing blower motor of indoor unit for 7.5 TON cap split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replacing blower motor of indoor unit for 5.00/3.5 TON cap split type AC (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement, complete all as specified and as directed.
Supply and replace PCB for indoor unit of three phase split type Acs any capacity, complete all as specified and as directed. make:HITACHI
Supply and replace PCB for Out door unit of three phase split type Acs any capacity, complete all as specified and as directed.make:HITACHI
Supply and replace contractor for outdoor unit of Three phase split type Acs any capacity, complete all as specified and as directed. make as per existing /sample.
Supply and replacing fan motor of outdoor unit for 4/5 Ton cap Three phase split type AC, complete all as specified and as directed. (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
Supply and replacing fan motor/Blower motor for out door/indoor for 3/3.5 TON cap three phase split type AC , complete all as specified and as directed. (Make Blue star/Voltas/HITACHI complete as per sample) as in replacement.
M&L for replacement of canopy /shed structure of split type AC Out door unit fabricated from 35x35x5 mm equal angle and MS flat of suitable size including bending and welding work and fixing /grouting of roof including painting with two coats of paint over a coat of red oxide etc, complete all as specified and as directed.
Material and labour for carefully dismentlling of automatic electronic voltage stablizer of cap 4KVA/5 KVA of any make and replacement of PCB and transformer complete unit reassembling and testing, complete all as specified and as directed.
Material and labour for DPX 160 MCCB DB TPN 4 Way Double door suitable for fixing MCCB as incomer and MCB for out going side including taking out existing DB and making good to distrubed surface, complete all as specified and as directed. Make Legrand/Havells/ABB
Material and labour for DPX 160 MCCB DB TPN 6 Way Double door suitable for fixing MCCB as incomer and MCB for out going side including taking out existing DB and making good to distrubed surface, complete all as specified and as directed. Make Legrand/Havells/ABB
Material and labour for DPX 160 MCCB 4 Pole not less than 16 KA of Cap 160 Amps adjustable type micro prcessor based including making connection for out going and incoming side, complete all as specified and as directed. Make ; Legrand/ABB/Havells.
Material and labour for DPX 160 MCCB 4 Pole not less than 16 KA of Cap 250 Amps adjustable type micro prcessor based including making connection for out going and incoming side all as specified and directed. Make ; Legrand/ABB/Havells.
Material and labour for replacement of MCB SP 20-32 Amps 10 KA , C , Curve, complete all as specified and as directed. Make ; Legrand/ABB/Havells
Material and labour for replacement of PVC/Fibre sheet 3m thick of superior quality of canopy of out door unit all as directed by Engineer-in-Charge.
Material and labour for ( in existing location and position) taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of any make, 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper winding wire of appropriate size ( as per existing ), complete all as specified and as directed. Make of winding wire : DEVIDAYAL /CHETAK complete
Supply and replacement of bush for cooler fan motor as per existing sample, complete all as specified and as directed.
Supply and replacement of shaft for cooler fan motor as per existing sample, complete all as specified and as directed.
Supply and replacement of oil filled capacitor 4.00 MFD for desert cooler fan motor, complete all as specified and as directed. Make : EPCOS/SHARDA/KENSTAR
Material and labour for replacement of bottom tank and top ( in existing location and position) of approx size - 750 X 750 X 200 mm ( as per existing ) for Desert Cooler made out of 18 gauge PGI sheet with and including two coats of synthetic enamel painting over one coat of red oxide primer on the new surfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing complete all as directed by Engineer-in-charge.
Material and labour for ( in existing location and position ) replacement of front grill ( as per existing )( horizontal and vertical members moveable) of the Desert Cooler made out of 20 gauge PGI sheet with Name plate complete all as approved by Engineer-in-charge.
Material and labour for replacement of side supporting columns to be fabricated out of 20 gauge PGI sheet of size 80x80x800 mm with and including necessary nut, bolts etc .all as directed by Engineer-in-charge.
Material and labour for replacement of side/rear panel made out of 22 gauge PGI Sheet with suitable handles with and including two coats of synthetic enamel paint over one coat of red oxide primer to match with the existing desert cooler all as directed by Engineer-in-charge.
Material and labour for painting to old steel surfaces of Desert cooler capacity up to 5000 Cft with one coat of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide primer on external surface and one coat of anti corrosive black paint inside the Body tank and side grills over a coat of red oxide primer complete including scraping/rubbing with wire brush on old surface of Desert cooler and writing of MES No etc complete at site or at E/M store yard all as specified and directed by Engineer-in-Charge .
Material and labour for replacement of Desert Cooler fan motor capacity 1/5 HP three speed, 1400 RPM single phase with aluminium fan blade, bracket supporting stand complete all as directed by Engr-in-Charge . Make: Crompton/ GEC/COOL HOME.
Material and labour for replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt complete all as directed by Engr-in-Charge . MAKE : RADO KR-1900/Khaitan/Coolhome
Material and labour for replacement of Wood wool pad for Desert Cooler of size 500 x 550 x30 mm (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill complete all as directed by Engr-in-Charge .
Material and labour for replacement of MS weld wire mesh having apparture size 25 mm and fitted in side grills/rear complete all as directed by Engr-in-Charge.
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 1.0 Sqmm cross sectional area superior quality complete all as directed by Engr-in-Charge .. Make: Plaza/Finolex
Material and labour for replacement of PVC water distribution cup of one inlet and 3 outlets fixed with MS nuts and bolts complete (as per sample) all as directed by Engr-in-Charge .
Material and labour for replacement of PVC elbow suitable for desert cooler (as per sample) all as directed by Engr-in-Charge .
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete all as directed by Engr-in-Charge .
Material and labour for painting to desert cooler stand with two coats of synthetic enameled paint of approved colour over a coat of red oxide primer including preparation of old surfaces complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz all as directed by Engr-in-Charge . Make :Anchor/Legrand/ABB
Material and labour for replacement of 3 pin plug top cap 15 Amp single phase AC Supply 240 Volts all as directed by Engr-in-Charge . Make :Anchor/Legrand/ABB
Material and labour for replacement of motor fixing ring (not less than 25 mm width ) for desert cooler eight screw / clip type(asper sample) complete all as directed by Engr-in-Charge .
M&L for taking down desert cooler installed at ground floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position, complete all as specified and as directed. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for taking down desert cooler installed at first floor /second floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position , complete all as specified and as directed. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for stand flush to wall for desert cooler fabricated out of MS angle iron 40 x 40 x 6 mm , 1.2 meter long bend to shape as top size 600 x 600 mm duly welded with two members to tie vertical support , including painting two coats of synthetic enamelled paint over a coat of red oxide primer including M&L for steel rack bolt / fastner 100 mm long 12 mm dia - 4 Nos for fixing stand all as directed by Engr-in-Charge .
Supply and fix in existing location and position PTMT stop cock 15 mm dia high pressure screwed for iron pipe, complete all as specified and as directed. Make: PRAYAG/POLYTUFF
Supply and fix in existing location and position PTMT Ball valves 15 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe, complete all as specified and as directed. Make: PRAYAG/POLYTUFF
M&L for wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FR PVC insulated , multistranded copper conductor cable ,( 2 X 1.5 Sq mm + 1X 1.5 Sqmm ), single core drawn in and including PVC casing capping 25 mm width , to be fixed on surface/ ceiling complete all as directed by Engr-in-Charge .
Supply and replace PVC moulded box of switch socket combination of cap - 15 Amp, complete all as specified and as directed. Make : ANCHOR/ LEGRAND
Note for all above items:-All items in BOQ are for"Materials and labour /Supply and fix" and to be executed in "Repairs i.e incl takng down old items" unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are required to quote their rates accordingly.
Dwarka Enterprises
M/s Ajay kumar Garge
M/S Dharam Chand Lal Chand Jain
S K TRADER
M/s Pankaj Enterprises
Bhawna Emporium
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .