Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹20.4 L+₹2.7 L (15.3%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹22.8 L+₹5.1 L (28.5%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹22.8 L+₹5.1 L (29.0%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹29.6 L+₹11.9 L (67.2%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Nov 2020, 6:00 pmClosed
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)/AMB-37(P)/2020-21 REPAIR/ REPLACEMENT AND RE-WIRING OF INTERNAL ELECTRIFICATIONS WITH OTHER ALLIED CONNECTED WORKS IN AREA -IV IN SECTOR B MD ACCN AND OTHER AREAS OF AGE E AND M (NORTH) AMBALA CANTT
2020_MES_339220_3
GE(N)Amb-37(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹60,000
Yes
16 Dec 2020
4 Nov 2020
26 Nov 2020
4 Nov 2020
24 Nov 2020
11 Nov 2020
4 Nov 2020 - 11 Nov 2020
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed/surface type on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes (modular type, size/modules as required at site) with and including screws, washers and modular cover plate over sunken box for housing the modular switches , socket outlets & fan regulators etc and making good the disturbed surfaces as per existing for one light point/bell/fan point controlled by one switch. Note:-1. Modular metal flush/sunken Box alongwith modular switch/socket cover plate & sheet are inclusive in the item rate quoted. 2. Only switch, socket and fan regulators to be measured and paid separately.
Description all as per Item No.1.02 here-in-before but One 3 pin socket point 5 Amps on independent board, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per Item No. 1.02 here-in-before but One 3 pin socket point 5 Amps on same board, complete all as specified and as directed by the Engineer-in-Charge.
Description all as per Item No 1.02 here-in-before but for one socket point 15 Amp with 4 sq mm PVC unsheathed FRLS-H, 1100 volts grade ISI marked with multi stranded copper conductor cable along with 4 sq mm green colour FRLS-H, 1100 volts grade ISI marked copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
S&F modular switch 6 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F switch modular 16 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F socket outlet modular 2/3 pin 5 Amp 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F socket outlet modular 6 pin 6/16 Amp 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F of electronic Fan regulator modular 5 step,100 watt 2 module complete all as specified and as directed by the Engineer-in-Charge.
S&F modular bell push 6 Amp 1 way 1 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S & F Calling bell ding dong type SP, AC supply, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S & F TV modular sockets 5 Amp 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix lamp holder,PVC/polycarbonate type with back plate for angular batten fittings complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down U/S bulbs complete all as specified and as directed by the Engineer-in-Charge.
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down U/S bulbs complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED box type fitting 18-20 watt, 4 feet, 6500K, aluminum housing and integrated electric driver including tube rod 18/20 watt, cool/warm white, surface/wall mounted industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, 6500K aluminium housing and integrated electronic driver including tube rod cool/warm type industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED surface mounted bulk head luminaries 8-10 W with min 800 lumen, industrial model, IP 65, Aluminum housing, surge protection including driver & LED lamp etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
S & F LED Bollard 8-11 W, IP-65 luminaire made of extruded aluminium housing & clear glass 240 volt, 50HZ, AC supply , complete with all accessories internally pre wired including connecting with flexible copper conductor from Electric Supply Source to connector of the light including PCC 1:3:6 of size 400x400x400 mm, including disconnecting and taking down existing old U/S fitting and removing complete all as specified and as directed by the Engineer-in-Charge.
S & F LED post top luminaire 30W-35W, 5700K, IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with fitting and provision of 3 core PVC flexible copper conductor from Electric Supply Source to connector of the light, including disconnecting and taking down existing light fitting and removing old U/S fitting complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB 20 Amp, 10 KA, 'C' curve including removing old Unserviceable enclosure complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DBs 8 way with 200 Amps rated bus bar single pole and neutral IP-43, double door fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surface after removing old Unserviceable MCB DB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral (VTPN) with TPN MCCB 125 Amp for 415 volts 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SP 6-32 Amps, 240 volt, 10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 32/40 Amps, 240 volt, 10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps 2 Pole, 2 module 100 mA (HI immunity) sensitivity 230 volts 50 Hz ISI marked, including removing old Unserviceable RCBO complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in repair over voltage release 230 V, single phase in one module complete all as specified and as directed by the Engineer-in-Charge.
S&laying sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor with one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified including taking out of old U/s sub main wiring of any size . Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Two run of 6 sqmm cable, one run of 6 sqm cable and PVC conduit shall be measured as one unit i.e RM.
S&laying sub main wiring with two run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor with one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified including taking out of old U/s sub main wiring of any size . Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Two run of 10 sqmm cable, one run of 10 sqm cable and PVC conduit shall be measured as one unit i.e RM.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 6 sq mm nominal cross sectional area cable with PVC insulated aluminium conductor multi stranded served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross sectional area cable with PVC insulated aluminium conductor multi stranded served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area 3.5 core with multi stranded aluminium conductor, 1100 volts grade, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge. Note:- For measurement, punned thickness shall be measured and paid.
Supply and laying well burnt bricks sub class-B old size, laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cables complete all as specified and as directed by the Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolts, including disconnecting and taking down existing pipe and removing complete all as specified and as directed by the Engineer-in-Charge.
M&L for earthing complete (in repairs) with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point and testing on completion all as specified and directed. Note :- Cost of excavation and earth work, PCC pit in cement concrete 1:3:6 type C1, RCC 1:2:4 type B1 in cover , 50mm thick reinforced with 8mm dia TMT bars bothways @ 15 cm center to center, funnel, watering pipe, wire mesh, charcoal dust, common salt and earth lead up to 7.5 mtr long shall be deemed to be included in the unit rate for earthing complete all as specified and as directed by the Engineer-in-Charge.
Refixing only existing serviceable LED light fittings of any description after cleaning complete all as specified and as directed by the Engineer-in-Charge.
M/S Sonu Traders
LAKHANPAL ELECTRIC
Saurav Enterprises
R N Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .