Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC | ₹30.6 L Quoted ₹30.9 L | L1 | Accepted-AOC LOWEST TENDER |
| 2 | L2₹31.4 L+₹48,131 (1.56%)Rejected-Finance | ₹31.4 L+₹48,131 (1.56%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹34.7 L+₹3.8 L (12.2%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹34.7 L+₹3.8 L (12.2%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹36.5 L+₹5.6 L (18.3%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | ₹36.5 L+₹5.6 L (18.3%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹37.9 L+₹7.0 L (22.8%)Rejected-Finance DOOR NO 38 I H COLONY MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | ₹37.9 L+₹7.0 L (22.8%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
11 Jan 2021, 6:00 pmClosed
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING AND OPERATION OF CENTRAL AC PLANTS AT MO V AND WED AREA INCLUDING CERTAIN MISC E M WORKS UNDER AGE E M NO I OF GE UTILITY II VISAKHAPATNAM
2020_MES_399909_1
8745
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-II
₹96,000
Yes
22 Jan 2021
14 Dec 2020
12 Jan 2021
14 Dec 2020
11 Jan 2021
30 Dec 2020
Amount
Manning and operation of 02 Nos central air conditioning plants of capacity 3x30 TR, 3X24 TR water cooled AC Plants complete including cooling tower, AHUs, electrical control panels, pumps and connected equipments etc., complete of the chilled water type AC system, round the clock in 3 shifts of 08 hrs each including sundays and holidays complete all as specified and as directed.
Manpower:- Skilled Operator of trained and experienced in AC Plant Operating system - 01 No per shift for each plant (Total 02 Plants) Plant 1 :- 3 X 30 TR Plant 2 :- 3 X 24 TR Skilled Operator Total - 02 persons per Shift Note:- (i) The operator ensure the smooth operation and maintenance of the AC plants. (ii) Maintaining the hourly parameters Log book for the AC plant. (iii) Operation of DG sets and maintaining the Log book for DG sets. (iv) The operator ensure the smooth operation and maintenance of the DG Sets. (v) Operator must have skill to rectify minor repairs like gasket change, replacement of fuse cutouts etc., complete In case of any faults to put the plant on working condition.
(vi) The operator should be in a position to intimate major defects/ repairs immediately to the concern JE / Engineer-in-Charge. (vii) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge. (viii) One emergency light and necessary tools should be available in a tool box with operator for smooth functioning.
Manning and operation of 02 Nos central air conditioning plants of capacity 3x30 TR and 3x24 TR water cooled AC Plants complete including cooling tower, AHUs, electrical control panels, and pumps and connected equipments in complete of the AC system, in 2 shifts of 08 hrs including sundays and holidays complete all as specified and as directed.
Manpower :- One UN- Skilled ( Helper) per shift. (02 Nos Helper (un-skilled) for all the three plants in 2 shift of 08 Hrs.) Shift timings:- I st shift - 0600 Hrs to 1400 Hrs II nd shift - 1400 Hrs to 2200 Hrs
Note:- (i) Taking care of house keeping environmental cleanliness area all around installation shall be kept absolutely neat and clean. Cost of all consumable stores such as brooms, cotton waste, cutters etc., deemed to be included in quoted rate. (ii) The Helper should be able to assist all the operators in general shift after keeping the plants clean & tidy. (iii) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
S & F 45 Watts Security / Street light fitting, pressure die cast aluminium housing with heat resistant glass IP65 protection including bracket made of 40mm dia GI light grade pipe of length 1.2 long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly prewired with 3 core 1 Sqmm weather proof FRLS copper conductor to fittings and painting to Steel surfaces including taking down old fittings complete all as specified and as directed by the Engineer-in-Charge. [Make: Surya Roshini Ltd of Cat No. SLE UL45W IP66 LXN or its equivalent of Philips / CG / Wipro / GE / BAJAJ]
M&L for Sheet metal enclosure for LT panel of suitable size Indoor type made out of 2.00 mm thick CRCA Sheet and including 40 x 40 x 5 mm MS angle iron frame with weather proof canopy,Bus bar of rating 200A for pahse and 100A for neutral and mounted on suitable PCC 1:3:6 type C1 pedestal, Cubical type, front and rear side openable, compartment type with hinged door and locking arrangement for each compartment, provision of air vent, dust and vermin proof duly painted with 2 coats powder coating over a coat of anti corrosive red oxide primer and including the following accessories are in built in with Panel board and taking down existing panel board complete all as directed by Engineer-in-Charge:-
(i) Provision for MCCB ,415 V,50Hz ,63A-02 NoS (ii) Provision for soft strater with contractor 7.5HP-02 NoS (iii) MCB 32A -02 NoS (iv) Digital Ammeter 0-100 Amps with CT's - 04 Set (v) Digital Voltmeter 0-500 Volts - 04 NoS (vi) LED type Indication lamps R,Y,B for three phases (Set of 3) - 04 NoS
Excavation in trenches n.exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in soft / loose soil for foundation, pipe lines etc,
PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in bases / pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in hard/dense soil.
Removing surplus excavated soil n. exc. 50 m and depositing where directed at a level n-exc 1.5 m above the starting point.
Labour only for attending break down of pipe line bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, MS / CI / DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering by using necessary dewatering pumps, JCB's, Cranes complete all as specified and directed by Engr-in-Charge, for the following sizes:- Note 1 :- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for Dismantling /fixing CI/DI/MS pipes, specials, fittings etc. Note 2 :- Earth work, Supply only (as for site , as per types , as per size) pipes, specials, fittings will be measured and paid seperately under relevant items.
100/80 mm bore DI/MS pipe
150 mm bore DI/MS pipe
200 mm bore DI/MS pipe
300 mm bore DI/MS pipe
Supply only MS ERW heavy duty pipe of 200mm dia, all as directed by Engr-in-charge.
Supply only MS ERW heavy duty pipe of 150mm dia, all as directed by Engr-in-charge.
Supply only MS ERW heavy duty pipe of 100mm dia, all as directed by Engr-in-charge.
Supply only MS ERW heavy duty pipe of 80 mm dia, all as directed by Engr-in-charge.
Supply only DI K9 water supply pipe lines of size 300mm bore NOTE: (i) Earth work if necessary will be measured and paid seperately. (ii) Labour required for fixing of DI pipe rate is included in Sl. item No. 9 of BOQ.
All as per Sl. item No. 14 above but for 200 mm bore
All as per Sl. item No. 14 above but for 150 mm bore
Supply only DI specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, "Y" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 150 mm bore.
All as per Sl. Item No.17 above but 200 to 300 mm bore.
Supply only MS flange 25 mm thick for 300 mm bore to be welded to MS pipe and including flange joint 6 mm thick rubber gasket with necessary nuts and bolts etc., complete all as specified and directed by Engr-in-Charge.
All as per Sl. item No.19 above but 300 mm bore and 20 mm thick flange joint
All as per Sl. item No.19 above but 200 / 250 mm bore and 15 mm thick flange joint
All as per Sl. item No.19 above but 150 mm bore and 15 mm thick flange joint
Supply and replace Pressure gauge dial of 6" dia, 0-16 kgs/cm2 ratings suitable to the existing water pipe lines including suitable fixing lines with necessary fixing arrangement complete all as specified. Make:- H-GURU/ FIEBIG.
Supply and replace Pressure gauge dial of 6" dia, 0-10 kgs/cm2 ratings suitable to the existing water pipe lines including suitable fixing lines with necessary fixing arrangement complete all as specified. Make:- H-GURU/ FIEBIG.
Supply only MS specials such as bends (any type, radius and angle) tapers any type, straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch, "Y" junction, double branch, cross (all sockets or sockets and spigot) collars, caps and plugs upto 450 mm bore.
M& L for servicing of LT panels of any size by cleaning the panel, bus bar chamber with CTC solution, and welding the door using arc welding and fixing hinges, necessary nut and bolts, washers and made it completely functional for open/ close including painting of panel by spraying with two coats of epoxy based paint over a coat of red oxide primer, after cleaning of rusty panel surface both inside/ outside by emery paper and necessary preparation of smooth surface suitable for painting and including checking of incoming and outgoing connections, Re-fixing of existing ACBs & MCCBs, testing & commissioning, connected PCC & frame works, rewiring of control and power wiring with suitable size of FRLS copper cable but not less than 1.5 Sqmm, replacing of various unserviceable ON/ OFF switches, lugs etc making the panel fully functional Complete all as specified and as directed.
Supply and laying in repairs XLPE FRLS cable, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 16 sqmm 4 core.
All as per Sl.item No.27 above but 25 sqmm 4 Core.
All as per Sl.item No.27 above but 35 sqmm 3.5 Core.
All as per Sl.item No.27 above but 50 sqmm 3.5 Core.
Supply & fix CI sluice valve PN 1.6 conforming to IS 14846 flanged end with iron wheel head, stainless steel spindle, flange joints and including necessary nuts, bolts, washers, rubber washer etc, and takidng down old sluice valve for the 300mm dia complete all as specified and directed by Engr-in-Charge:-
All as per Sl.item No.31 above but 250 mm bore
All as per Sl.item No.31 above but 200 mm bore
Supply and replacement of CI foot valve 250 mm bore complete all as specified and directed by Engr-in-Charge.
All as per Sl.item No.34 above but 200 mm bore
All as per Sl. item No.34 above but 150 mm bore.
Supply& fix of shell and tube type cooler for water cooled chiller of capacity 30 TR central AC plant along with new tube fixing end to end expending with new shell, (tube size: 1/2 inch , tube length : 1900 mm, tube thickness : 1mm, no of tubes : 155) complete all as specified and directed by Engr-in-Charge.
Supply and replacement of scroll compressor 13 TR air cooled ductable package conditioner / package unit and rectify the control wiring defects if any, connecting back all control and refrigerant piping after necessary modifications as requirred for the system, pressure testing with nitrogen gas under constant pressure upto 300 PSI kg/Sqcm for minimum 24 hours vaccumising, gas charging, commissioning and checking the performance of the system complete all as specified and directed by Engr-in-Charge. Make : Blue star / York / Carrier
Supply of R 407 refrigerant gas complete all as specified and directed by Engr-in-Charge. Make:- Floron/Mafron
Y RAMESH
M/S EVEREST INFRA
SRIESWARI ENTERPRISES
Prasad and Suresh Constructions
AYYAPPA CONSTRUCTIONS
SAI ENGINEERING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .