| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.5 Cr+₹4.6 L (1.87%)Rejected-AOC S O LT MANINDRA BASUMATARY VILL P O BANARGAON P S DOTMA DIST KOKRAJHAR BTC ASSAM | BANARGAON | KOKRAJHAR | ASSAM | ₹2.5 Cr+₹4.6 L (1.87%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.5 Cr+₹4.9 L (1.98%)Rejected-AOC | ₹2.5 Cr+₹4.9 L (1.98%) | L3 | Rejected-AOC L3 |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
4 Nov 2019, 4:30 pmClosed
Sri J.M. Basumatary
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar
Construction of the proposed Residence for the Secretaries of Bodoland Territorial council at Kokrajhar under Grants to BTC for Infrastructure Development for the financial year 2019-20.
2019_BTC_14487_1
71/NIT/InfraDev/BTC/2019-20/10
Open Tender
Civil Works - Building
Item Rate
365 days
Bodofa Nwgwr
Refer to SBD
6 documents required · 6 mandatory
₹7,500
Principal Secretary, BTC, Kokrajhar.
₹5.0 L
Yes
21 Feb 2020
24 Oct 2019
5 Nov 2019
24 Oct 2019
4 Nov 2019
24 Oct 2019
24 Oct 2019 - 4 Nov 2019
Amount
CIVIL WORKS: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps, septic tank etc. up to depth of 2 M below the existing ground level including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in hard/dense soils including bailing out water where necessary as directed and specified.
1.1(B) Extra over item No. 1.1.(a) above for each 1m depth or part there of beyond the initial depth of 2m.
1.3(c ) Earth/Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150mm thick including necessary, carriage, watering ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
NOMINAL MIX (P.C.C. WORKS) 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.1.3 Providing and laying 25mm thick damp proof couarse with cement concrete in Prop : 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
REINFORCEMENT CEMENT CONCRETE WORKS: 2.2.1 Providing and laying controlled cement concrete work of grade 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (i) (A) In substructure upto plinth level. Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not below 100mm thick.
2.2.1 Providing and laying controlled cement concrete work of grade 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (ii) (B) In super structure Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase including preparing the top surface and finishing of noising.
2.4 Extra over item no. 2.2(I) above for each subsequent floor or part thereof above 1st floor level.
2.4 Extra over item no. 2.2(I) above for each subsequent floor or part thereof above 2nd floor level.
FORMWORK: 3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Column, pillars posts & struct of square/rectangular/Polygonal in plain or any shape like Tee/L etc having plane vertical face.
3.2.1.2 Sides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
3.2.1.3 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) floors etc. upto 200mm in thickness.
3.2.1.8 Staircase with sloping or stepped soffits including risers and stringers but excluding landing.
3.2.3 Providing form-work of 12mm thick plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first level. (a) Thickness not exceeding 200mm
3.2.4 Extra for each subsequent floor or part thereof above the 1st floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
3.2.4 Extra for each subsequent floor or part thereof above the 2nd floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
3.2.5 Extra for each subsequent floor or part thereof above the 1st floor level as mentioned in item no. 3.2.3(a).
3.2.5 Extra for each subsequent floor or part thereof above the 2nd floor level as mentioned in item no. 3.2.3(a).
BRICK WORK: 4.1.1 Providing brick flat soling in foundation and under floor with stone/best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials, and if necessary dewatering, complete.
4.1.2 Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
4.1.3 Extra for lifting of brick bats and sand for filling of suck floor for each subsequent floors above the ground floor as directed and specified.
4.1.4(d) Brick work in 1:6 cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level.
4.1.8(a) 112mm thick 1st class brick nogged wall in 1 cement: 4 samd mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level ( protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (i) In ground floor upto 1st floor slab.
4.1.16(i) Extra for brick wall for each subsequent, floor or part thereoff above the 1st floor level as mentioned in it. No. 4.1.7(a)
4.1.16(i) Extra for brick wall for each subsequent, floor or part thereoff above the 2nd floor level as mentioned in it. No. 4.1.7(a)
FLOORING 5.1.2 25mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12 mm nominal size) finished with a floating coat of neat cement finish( base concrete to be measured and paid separately) to be laid in panel including cuyring complete as directed.
5.7.2.1 Providing polished vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on skirting, floors, risers and tread of steps over cement plastering bed15mm thick in prop 1:3(1cement :3coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite /Rouf)/ Bal Endura/white cement slurry mixed with approved pigment to match shade of tiles, complete at all levels as specified and directed. (Cement plastering will be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (a) Normal range (Size 600mm X 600mm) (i) Orient made
(c ) Delux range (Size 1000mm X 1000mm) (vi) Orient made
5.7.1.2 Providing polished ceramic tiles of approved quality, size, shape and thickness not less then 8mm in dado on a bed of 10mm thick cement plaster 1:3 jointed flush with white cement slurry mixed with matching pigment at all levels as specified and directed in toilet. (b) Executive range (Size 200mm X 300mm and above) (a) Orient made.
5.11.1 Providing anti-skid tiles of approved quality size, shape and thickness not less than 8mm on floors, skirtings over a cement mortar bed 15mm thick of 1:3 (1cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-tiles (Choksey/Sika/Pedelite/Rouf)/ white cement mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (a) Normal range (Sizes 300mm X 300mm and above)
5.11.1 Providing anti-skid tiles of approved quality size, shape and thickness not less than 8mm on floors, skirtings over a cement mortar bed 15mm thick of 1:3 (1cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-tiles (Choksey/Sika/Pedelite/Rouf)/ white cement mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (a) Normal range (Sizes 600mm X 600mm and above)
5.10.3 Providing polished granite slab of approved quality, size , shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop 1:3(1cement :3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed.(Cement plastering to be measured and paid separately).(Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department.) (ii) With White cement.
5.8.2 Kota stone slab of 18mm thick in riser of steps, skirtings, dado and pillars laid with 10mm thick base of cement plaster 1:3 (1cement : 3 coarse sand) laid over and joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (i) 550mm X 550mm
5.9.2 18mm thick marbel stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop 1:3 (1cement :3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels. (a) With 18mm thick marble stone tiles of size 300mm X 300mm (iii) Kumari Marble.
5.7.3.1 Providing polished GEMS CONCRETE/ SUNROCK-Hi CTS of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (B) SUNROCK-HI CTS TILES
6.2.2(a) 15mm thick 1:4 cement plaster in single coat on rough side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal roundred angels, chamfers and/ or rounded angles not execeeding 80mm in curing finished even and as specified and directed.
6.2.2(b) 15mm thick 1:4 cement plaster in single coat on rough side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal roundred angels, chamfers and/ or rounded angles not execeeding 80mm in curing finished even and as specified and directed.
6.2.4(b) 20mm thick cement plaster in two coats, backing coat 15mm and finishing coat 5mm thick on rough side of single or half brick walls for interior plastering up to 1st floor level including arieses, internal rounded angles, chamfers and /or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed.
6.2.5 Exra over item no 6.2.1 to 6.2.5 for plastering on ceiling and soffits of stairs up to 1st floor level.
6.2.5 Exra over item no 6.2.1 to 6.2.5 for plastering on ceiling and soffits of stairs up to 2nd floor level.
6.2.6 Exra over item no 6.2.1 to 6.2.5 for plastering above 1st floor level for additional floor or part thereof including curing complete as directed. (i) Single coat plaster (a) in the first floor.
6.2.6 Exra over item no 6.2.1 to 6.2.5 for plastering above 1st floor level for additional floor or part thereof including curing complete as directed. (i) Single coat plaster (b) in the second floor.
6.2.8 Extra over item no 6.2.1 or 6.2.5 for exterior plastering over wall for every addl. floor or part thereof beyond 1st floor level including curing complete as directed. (i) Single coat plaster. (a) In the first floor.
6.2.8 Extra over item no 6.2.1 or 6.2.5 for exterior plastering over wall for every addl. floor or part thereof beyond 1st floor level including curing complete as directed. (i) Single coat plaster. (b) In the 2nd floor.
WOOD WORKS: 9.1.2 Providing wood work in frame (chowkaths) of doors, windows, clearstory window and other similar works wrought, framed and fixed in position in contant with C.C. or brick masonry wall including supplying, fitting and fixing M.S. hold fast (40mm X 3mm X 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber face in contact wit C.C and masonry as directed and specified. (b) With 1st class timber (Hollock/sundi)
9.6.1 Providing and fixing 1st class timber moulded architrave of size 50 X 20mm to door and window frames with countersunk wood screw, wooden plugs and applying a coat of wood preservative on unexpected surfaces etc. (b) 1st class local wood (Hollock/Bonsum)
9.9.2 Providing and fixing full pannelled door shutters including oxidised M.S butt hings ( 100mm X 75mm X 3.55mm) with necessary screw (other fittings to be measured and paid separately) (B) With 1st class local wood (Hollock/Bola/Bonsum) (ii) 35mm thick
9.12.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm X 75mm X 3.5mm) 6 nos with necessary wood screws. (c ) One face decorative and other face nondecorative type and block board core. (ii) 35mm thick.
13.3.1 Providing surface preoaration for walls, ceiling etc. using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and plaster of paris past, making the surfaces even and smooth complete at all levels as specified and directed.
13.2.2 Distempering (two coats) with oil bound distemper of approved brand and manufacture and of required shade on new ceiling surface to give an even shade, over and including a priming coat with alakli resistant primer of approved brand and manufacture after throughly brooming the surface free from mortar droppings and other foreign matter and also including preparing surface even and sand papered smooth. 13.2.2(d)+(n)(i)+(n)(ii)+(q)
13.4.7 Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from morter dropping and other foreign matter and sand papered smooth.
13.2.3(a) Applying one coat of cement primer of approved brand and manufacture on new internal and external wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.5 Finishing wall with water proofing weather coat smooth anti-fungal exterior painting of Ace brand of Asian Paints and of required shade on old/new wall after clearing the surface etc. including scaff-olding complete as directed at all levels. (two cats)
13.6.3(a) Applying priming coat with ready mixed paint,wood primer (pink) over new wood based surfaces over 100mm in girth/width after and including preparing the durface by throughly cleaning oil, grease, dirt and the foreign matter, sand papering and knotting.
13.6.5(a) Painting two coats surfaces over 100mm in width or girth (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian /Berger paint/ICI paint/J&N paint/Nerolac) to give an even shade including clearing the surfaces of dirt, dust and other foreign matter sand papering and stooping.
13.7.2(a) Applying primary coat with ready mixed "red-lead/red-oxide" primer over new steel and other metal surface up to 100m in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
13.7.4(i) (a) Painting two coats surfaces over 100mm in wdith or girth (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac paint) to give an even shade including clearing the surfaces of dirt, dust and other foreign matter.
10.2 Providing, fitting and fixing M.S. grill of required plain grill pattern for windows/ clerestory window/opening fixed to brickwork/P.C.C/R.C.C with M.S. flat at required spacing in frame all round, square or round M.S. bars with round headedbolts and nuts or screws. (I) Plain grill (c ) Fixed to brickwork/P.C.C/R.C.C.
15.3.1 Supplying, fitting, fixing brass fittings of approved make, reasonably smooth, free from sharp edges and corners, flawsand other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (a) Sliding bolts (ii) 250mm X 16mm sliding door bolt.
15.3.1 Supplying, fitting, fixing brass fittings of approved make, reasonably smooth, free from sharp edges and corners, flawsand other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (b) Tower bolts (iii) 200mm X 10mm tower bolt.
15.3.1 Supplying, fitting, fixing brass fittings of approved make, reasonably smooth, free from sharp edges and corners, flawsand other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (v) 150mm X 10mm tower bolt.
15.3.1 Supplying, fitting, fixing brass fittings of approved make, reasonably smooth, free from sharp edges and corners, flawsand other defects and with counter sunk holes for wood screws including necessary screws etc. complete. (c ) Door handles (iii) 150mm
15.5.1 Supplying, fitting and fixing drapery rods along with all accessories in doors, windows and other openings complete as specified and directed by the department at all levels. (A) MAC Drapery rod (i) Gold line and silver line
ALUMINIUM DOORS AND WINDOWS 11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangement, screws etc as required complete as specified and directed for all levels. (a) 2 Track sliding window (ii) 5mm frosted glass
11.1.2 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangement, screws etc as required complete as specified and directed for all levels. (b) 3 Track sliding window (i) 6mm clear glass
11.2.8 Providing, fitting and fixing anodised aluminium framed double leaf glazed doors with anodised aluminium frame made of 100mm X 45mm X 2 mm sections with door style of size 81mm X 45mm X 2mm, top rails 50mm X 45mm X 2.0mm, lock rails 81mm X 45mm X 2mm, bottom rails 100mm X 45mm X 2mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock , angles, cleat etc. complete as specified and directed by the department at all levels. (i) 6mm clear glass.
PLINTH PROTECTION WORKS AND PERIPHERY DRAINS 19.2 Proving plinth protection with brick flat laid in cement martar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
19.5 Providing 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm drain with brick work in cement mortar in prop. 1:5 with half brick side wall and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plaster in prop 1:3 finished with a floating coat of cement slurry as directed with necessary earth work in excavation of foundation trenches and refilling the sides after completion of work as specified.
ANTI TERMITE TREATMENT 26.1.1 Pre constraction anti-termite treatment at the bottom of foundation pits and walls on either side upto a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @5(five) liters per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or euivalant) and water. This provies emulsion containing 1% chloropirophose solution (by weight)
26.1.2 Pre construction anti-termite treatment in the back filling in immediate contact with the foundation structure after completion of column wall etc. to a depth of 450mm and width 300mm (When required refill in 200mm thick layers) by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (trical or euivalant) and water, this provides emulsion containing 1% chloropirophose solution (by weight)
26.1.3 Pre constraction anti- termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the department complete. (a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or equivalent) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
26.1.5 Pre construction anti-termite treatment by applying the soil along the external perimeter of the building after completion of construction to a distance close to the plinth wall as specified and as directed by he deptt. Up to a depth of 300mm making rod holes at 150mm c/c upto 300mm below by applying emulsion @ 4.5 (four point five) litres per running meter ensure moistening of the soil with the emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) With aqueous emulsion having concentration 1:19 with chloropirophose solution ( tricel or euivalent ) and water. This provides emulsion containing 1% chloropirophose solution (by weight)
REINFORCEMENT: 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, spacers etc. complete (up to 1st floor level) (b) ISI approved super ductile TMT bars. (ii) Other ISI marked.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, spacers etc. complete (up to 1st floor level) (d) Exra for each subsequent floor or part thereof above first floor level.
18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, spacers etc. complete (up to 1st floor level) extra for each subsequent or part thereof above second floor level.
18.9.1 Providing, fitting and fixing Godrej SS 304 grade railing with pipes/glass for different staircase, cutous areas, balcony etc. with complete installation, Acrylic finish etc. which is fitted with mid pipes and top pipes of good quality steel. Moreover, depending on the requirement glass panels can also be fittedon specific railings. Good quality screws are provided for fixing up the railings. (a) SS Railing Steel with Wire Locator.
DOOR FRAMS 18.7.1 Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mm X 40mm X 5mm fabricated, welded, mitred and joined as per relevent I.S. Codes including fitting 8 nos of M.S. hold fast, providing closing/holding device for 2nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hings to be paid as per relevent item of the schedule of rates)
ROOFING 8.1.41 Providing colour coated DURASHINE/TATA BLUESCOPE zinc-aluminium profile sheet (Total coated thickness=0.45mm) of nominal 1015mm effective cover width and nominal 28mm deep ribs with subtle square fluting in the five pan at nominal 203mm centre-to-centre including fasteners class 2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) (A ) DURASHINE ROOF PROFILE (0.45mm(TCT) X 1072mm)
8.1.45 Providing colour coated DURASHINE (TATA BLUESCOPE) zinc-aluminium roof,wall and tile profile sheet accessories (Total coated thickness=0.45mm) including fasteners class2 SDS, fitting and fixing complete. (Roof trusses, purlins etc. to be measured and paid separately.) (i) Plain Ridge
9.4.1 Providing barge board of size 200mm X 20mm with 1st class local Hollock/ Bonsum timber/BISON Board including fitting and fixing with necessary wood screws etc. complete.
22.3.10 Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified styrene Butadiene Rubber based polymer lijke Sika Latex of Sika India Ltd., by brush after proper surface preparation (Surface preparation including through cleaning of surface to be measured and paid separately) as specified & directed by the Department complete,
ROOF TRUSS 18.3.1 providing, fitting, hoisting and fixing of roof trusses including purlins fabricated out of M.S. black tubes conforming to relevent I.S. code as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed.
FALSE CEILING 7.2.8 Supplying fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which including G.I. Perimeter channels of size 0.55mm thick (having one flang of 20mm and another flang of 30mm and a web of 27mm) along with perimeter of ceiling, screws fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm C/C. The suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the sofits at 1220mm c/c with ceiling angle of width 25mm X 10mm X 0.55mm thick fixed to soffits wih G.I cleat and steel expansion fasteners. Ceiling section of 0.55 thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermidiate channels with the help of connecting clip and in direction prependicular to the intermediate channel at 457mm c/c, 9.5mm/12.5mm tapered edge Gypboared (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. screws fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally , the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square of the boards with jointing compound , joints paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed .(for light fitings, providing opening for doors, window , ventilators etc, cut out made with frame of perimeter channel supported suitable to be measured and paid separately where necessary) (ii) 12.5mm thick
29.2.1 Supply, Installation, fixing of DRY CHEMICAL POWDER Fire Extinguisher conforming to IS:2171 with ISI mark and CO2 cartridge will be conforming to IS:4947 with ISI mark, Powder will be conforming to IS:4308 with ISI mark (5 KG) BRAND:FIRESTOP/FIREND/FIRE SHIELD/GETECH/MINIMEX
29.2.9 Supply, Installation, fixing of CARBON DIOXIDE Fire Extinguisher conforming to IS:2878 with ISI mark (4.5 LITERS) BRAND:FIRESTOP/FIREND/FIRE SHIELD/GETECH/MINIMEX
MARKET RATE: Providing, fitting and fixing glassfiber Reinforced concrete (GRC) Cornice Profile of BHUTAN GRC brand to RCC chajjas with anchor bolts as per details including making good the surface by filling the joints with 1:3 cement sand mortar wherever required as directed abd specified. Gun Sprayed GRC Cornice Profile unto approved mould developing ultimate strength of not less than 20 MPa having minimum 1990KG/M3 dry density. (i) Single band with cornice
MARKET RATE: Providing, fitting and fixing glassfiber Reinforced concrete (GRC) Cornice Profile of BHUTAN GRC brand to RCC chajjas with anchor bolts as per details including making good the surface by filling the joints with 1:3 cement sand mortar wherever required as directed abd specified. Gun Sprayed GRC Cornice Profile unto approved mould developing ultimate strength of not less than 20 MPa having minimum 1990KG/M3 dry density. (ii) Double band with cornice
SANITARY WORKS: 1.1.3 Providing fitting and fixing starwhite vitreous water closet squatting pan (Indian type W.C. Orissa pattern) of size 58 X 44 X 25 with 100mm SCI 'P' or 'S' trap, 10 litre low level PVC flushing cistern with manually controlled device (handle over) (Sleek Plus Single Flush) of Hindware make with all fittings and fixtures complete including cutting and making good the walls and floors wherever required (Cat. No. 20076)
1.3 Providing, fitting and fixing starwhite vitreous china wall mounted type KYLIS water closet (European type W.C. pan 380 X 370 X 550) of Hindware make with starwhite CONSTELLATION slow falling PVC seat with cover of HINDWARE make including all accessories provided for by the manufacture including painting of fittings and brackets, cutting and making good the walls wherever required with P trap. (Cat. No. 92080)
Providing, fitting and fixing starwhite vitreous china pedestal type STAR S water closet (European type W.C. pan 390 X 360 X 550) of Hindware make with starwhite CONSTELLATION slow falling PVC seat with cover of HINDWARE make including all accessories provided for by the manufacture including painting of fittings and brackets, cutting and making good the walls and floors wherever required with S trap. (Cat. No. 20087)
Providing, fitting and fixing PVC concealed cistern 77.5 mm deep with all accessories provided for by the manufacture with two lever Glossy Chrome plated flush plated including cutting and making good the walls wherever required. (Concealo Smart 77.5-code 506743)
1.7(v) Providing, fitting and fixing starwhite vitreous china flat back type lipped front urinal basin of size 610 X 390 X 370 of Hindware make with C.I/M.S brackets etc. complete, with photo volltaic sensor automatic flushing with all accessories as provided for by the manufacture including painting of fittings and brackets, cutting and making good to the walls and floors wherever required. (SENSO ART-60018)
1.13(B) Providing vitreous china STUDIO wash basin of size 570 X 480 of Hindware make with semi pedestal including CI/MS brackets,. 32mm CP brass waste coupling of standard pattenr, CP stop cock, CP brass chain with plug, PVC waste pipe with all accessories as provided for by the manufacture including painting of fittings and brackets, cutting and making good to the damage of the floors and walls (a) Starwhite vitreous china wash basin of size 570 X 480mm (cat. No. 10096 & 11038)
1.13.5 Counter Top Basin (B) ii Hindware make (Optra 570 X 440 (Cat No 91008)
1.13.3 Wall hang Basin (a) White vitreous china wash basin of size 45 X 30mm (Cat No. 10004)
1.9.5 Providing fitting and fixing stainless steel kitchen sink of Agmeco make coupling and strainer of same make, C.I. brackets, PVC waste pipe including painting of fittings, cutting and making good the walls and slabs wherever required. (B) Single Bowl with single drain board (vii) bowl size of 355 X 355 X 180mm
1.18 Providing, fitting and fixing mirror with plastic frame of size 500 X 400mm complete as directed and specified.
21(a) Providing, fitting and fixing recessed soap tray /soap dish complete as directed and specified.
1.23(ii)a Providing, fitting and fixing liquid soap Dispenser and liquid soap container of Agmeco make complete as specified and directed.
1.24(iv) Supplying, fitting and fixing chrome plated C.P. towel rail of Sona make complete as specified and directed.
1.15.5(b) Supplying, fitting and fixing chrome plated C.P. towel rack of sona make complete as specifed and directed.
Supplying, fitting and fixing chrome plated C.P. towel of Agmeco make complete as specifeid and directed.
1.27(c )ceramake Supplying, fitting and fixing chrome plated C.P. robe hook of Agmeco make complete as specifeid and directed.
1.30 Supplying, fitting and fixing Brass tumbler Holder of Agmeco make complete as specified and directed.
33(b) Supplying, fitting and fixing C.P. bottle trap Economy model of Sona make complete as specified and directed.
1.37.1 Supplying,fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamp etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (ii) 110mm dia.
1.37.2 Supplying, fitting and fixing 87.5 degree PVC bend of Supreme/Prince make including, joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed. (a) In exposed surfaces or in trenches. (ii) 110mm dia
1.37.3 Supplying, fitting and fixing 45 degree PVC bend of Supreme/Prince make including, joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed. (a) In exposed surfaces or in trenches. (ii) 110mm dia
1.37.5 Supplying fitting and fixing PVC Plain single tee of Supreme/Prince make including joining, fitting and fixing etc. as necessary complete as all levels including below G.L. as directed. (a) In exposed surfaces or in trenches. (ii) 110mm dia
1.37.6 Supplying fitting and fixing PVC single tee with door of Supreme/Prince make including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
1.37.13 Supplying fitting and fixing P.V.C coupler of Supreme/Prince make including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed. (a) In exposed surfaces or in trenches. (i) 110mm
1.39(ii) Providing, fitting and fixing 110mm dia PVC cowel of ISI make complete as directed and specified.
1.40 Providing, fitting and fixing CP grating to the floor complete as directed and specified with PVC floor trap. (b) 100 mm dia
1.47 Providing fitting and fixing 450mm dia 90mm thick C.I. Man hole cover and frame of 58Kg weight complete as directed and specified.
1.52 Construction of inspection pit inside measurement 450mm X 450mm X 450mm flush with 110/160 dia PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 115cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor finished with floating coat of neat cement, 450mm X 450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pits as directed.
1.51 Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/ charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (Size of soak pit may vary depending on the size and capacities of the septic tank as well as the number of sures as mentioned in the table.)
Providing brick masonry septic tank of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc. are provided at suitable points complete as directed. 25 users.
Excavation of 300 wide and 450 deep trench to lay 110 dia. PVC pipes including flat brick soling, laying of pipe, covering pipe by laying 200 thick 1:3:6 PCC over soling and PVC pipe by providing shuttering on both sides and back filling earth complete as directed.
WATER SUPPLY WORKS 3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0M spacing. This include joining of pipes & fittings with one step CPVC solvent cement and tetsting of joints complete at all level as directed and specified. I. In exposed surface or in trenches. e. 40mm dia
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0M spacing. This include joining of pipes & fittings with one step CPVC solvent cement and tetsting of joints complete at all level as directed and specified. I. In exposed surface or in trenches. f. 50mm dia.
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0M spacing. This include joining of pipes & fittings with one step CPVC solvent cement and tetsting of joints complete at all level as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C.?RCC and making good the dameges. f. 15mm dia.
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0M spacing. This include joining of pipes & fittings with one step CPVC solvent cement and tetsting of joints complete at all level as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C.?RCC and making good the dameges. e. 20mm dia.
3.16 Supplying fitting and fixing Ajoy Flowguard brand CPVC pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting including clamps at 1.0M spacing. This include joining of pipes & fittings with one step CPVC solvent cement and tetsting of joints complete at all level as directed and specified. II. Concealed by chiselling or breaking brick wall/C.C.?RCC and making good the dameges. d. 25mm dia.
3.2.1(IV)(V) Supplying fitting and fixing C.P. two bib cock with flange as directed and specified.
3.2.1(IV)(iv) Supplying fitting and fixing C.P. long body bib cock with glange of Agmeco make as directed and specified.
3.3.2 Supplying fitting and fixing C.P. cock of as directed and specified. b(i) Angle cock (Cat No. F110004)
3.3.2 Supplying fitting and fixing C.P. cock of as directed and specified. b(ii) Concealed stop cock 15mm (Cat No. F110005)
3.9.1(I)(i) Supplying and fitting fixing C.P. central hole basin mixer as directed and specified.
3.5.1(III)(a) Supplying and fitting and fixing C.P. pillar cock of Hindware (IMMACULA) make as directed and specified. (Cat No. F110001)
3.6.1(ii)(a) Supplying and fitting and fixing C.P. pillar cock of Hindware (IMMACULA) make as directed and specified. (Cat No. F110021)
3.8.2(III) Supplying fitting and fixing chrome plated (C.P.) over head shower.
3.8.2(V) Supplying fitting and fixing chrome plated (C.P_ heavy casted shower arm
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specifed and directed. (a) 50mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specifed and directed. (b) 40mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specifed and directed. (c ) 25mm dia
3.17.1 Supplying and fitting gun metal country pit valve (full way valve) ISI make as specifed and directed. (d ) 20mm dia
5.4.2 Supplying and placing plastic cylindrical vertical claused top PCVC tank sintex/ polycon/ patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes complete as directed. (A) 2000 litre capacity (i) Sintex make
SECRETARIES APARTMENT: A. SCHEDULE ITEMS Wiring with HFFR cable and Modular switch etc. (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 3.11 Wiring for light point/fan point/call bell point with 1.5 sq mm insulated (ISI maked) HFFR Copper Conductor Cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by short point up to 3.00 mtr. Length
3.11 Wiring for light point/fan point/call bell point with 1.5 sq mm insulated (ISI maked) HFFR Copper Conductor Cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by Medium point up to 6.00 mtr length
3.11 Wiring for light point/fan point/call bell point with 1.5 sq mm insulated (ISI maked) HFFR Copper Conductor Cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by Long point uo to 10.00 mtr. Length
3.11 Wiring for light point/fan point/call bell point with 1.5 sq mm insulated (ISI maked) HFFR Copper Conductor Cable in recessed P.V.C conduit, 2.0mm thick of required size with ceiling rose, without switch and switch board as directed by Extra long point uo to 15.00 mtr. Length
SB 8.24 Supplying including installation of socket outlet 3/16 Amps 3/5 pin combine shuttered complete as per direction of department.
SB 8.26 Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete as per direction of department.
SB 8.9 Supplying with fitting fixing 16 Amp one way modular clip in switch in recessed system with lector/indicator including making necessary connection complete as direction of
SB 8.2 Supplying with fitting fixing 6 Amp one way modular clip in switch in recessed system including making necessary connection complete.
SB 8.23 Supplying with fitting fixing 6 Amp one way modular clip in bell in recessed system including making necessary connection as per
AB 8.1.1 Supplying with fitting and fixing 120watt electronic modular fan speed controller including making necessary connection as per direction of
SB 8.34 Supplying including and fixing of metal boxes in recessed system complete as direction of (a) 1-3 module flash type
SB 8.34 Supplying including and fixing of metal boxes in recessed system complete as direction of (b) 4-5 module flash type
SB 8.34 Supplying including and fixing of metal boxes in recessed system complete as direction of (c ) 6-8 module flash type
SB 8.34 Supplying including and fixing of metal boxes in recessed system complete as direction of (d ) 10 module flash type
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of a) 1 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of b) 2 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of c) 3 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of d) 4 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of e) 5 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of f) 8 module
SB 37 Supplying including fitting fixing of logic front plate of suitable colour as per direction of g) 10 module
13.2 Supplying with fitting fixing plug and socket D B's common for lexic MCB and load Kontakt/load stop 13.2.1.1 Flush mounting distribution board with metal plug and socket 20 Amps capacity
9.1.6 Wiring for sub -main with insulated (ISI or approved) HFFR Copper conductor Cable single core in recessed conduit, 2.0mm thick with earth continuity as directed by the department. With 4 X 10 sq.mm + earth continuity with 1 X 4 sq.mm PVC. Insulated unsheathed single core copper Rigid PVC Conduit pipes.
P.V.C INSULATED COPPER WIRING IN RECESSED PVC CONDUIT WITH SINGLE CORE STRANDED COPPER CONDUCTORSPECIFIC BRAND OF MATERIALS (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 4.7 Wiring for drawing sub-main line with P.V.C insulated unsheathed 1.1 K.V grade (ISI marked, R.R. cable/Finolex?Havells make) single core copper conductor cable in with earth continuity in Recessed PVC conduit wiring 4.7.1 With 2 X 2.5 sq.mm + earth continuity with 1 X 2.5sq.mm PVC insulated unsheathed single core copper condctorcable 20mm dia. 2mm
4.7 Wiring for drawing sub-main line with P.V.C insulated unsheathed 1.1 K.V grade (ISI marked, R.R. cable/Finolex?Havells make) single core copper conductor cable in with earth continuity in Recessed PVC conduit wiring 4.7.2 With 2 X 4 sq.mm + earth continuity with 1 X 2.5sq.mm PVC insulated unsheathed single core copper condctor cable 25mm dia. 2mm thick. Rigid PVC Conduit Pipes.
4.7 Wiring for drawing sub-main line with P.V.C insulated unsheathed 1.1 K.V grade (ISI marked, R.R. cable/Finolex?Havells make) single core copper conductor cable in with earth continuity in Recessed PVC conduit wiring 4.7.3 With 2 X 6 sq.mm + earth continuity with 1 X 4sq.mm PVC insulated unsheathed single core copper condctor cable 20mm dia. 2mm thick. Rigid PVC Conduit Pipes.
SUPPLYING AND FIXING RIGID P.V.C CONDUIT IN SURFACE AND RECESSED SYSTEM (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONTMENT FRIENDLY) Supplying including fitting and fixing of rigid PVC Conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view 6.1(a) 19 mm dia, 1.5mm thick rigid PVC. Conduit
Supplying including fitting and fixing of rigid PVC Conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view 6.2(b) 25 mm dia, 1.5mm thick rigid PVC. Conduit
Supplying including fitting and fixing of rigid PVC Conduit pipes in recessed wiring system including cutting the wall beam column etc. and making finish the its original Architectural view 6.3(c ) 32 mm dia, 2mm thick rigid PVC. Conduit
11.15 Supplying and fixing fancy wall bracket of Anodized aluminium 12mm. Dia fixed on 3mm. Thick 170mm X 40mm M.S. plate with brass bracket lamp holder including shade etc.
11.21 Supplying and fixing 200/250/305mm dia. (Normal size) flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder including connections etc. (b) 250mm dia. Etc. as required
11.10 Supplying and fixing brass batten holder including connections etc. complete (Without shades &
11.25 Supplying and fixing frosted glass shed of 100mm dia. (Nominal size) as required
11.32 Supplying and fixing call bell (Buzzer) including 5 Amps capacity flush Piano type bell push switch including connections etc. as required complete.
PROVIDING EARTH, LOOP EARTH AND EARTH STATIONS AND LIGHTING CONDUCTOR( ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 193(a) Installation of Earth station with 40mm. Dia and 4.50 metre long G.I. pipe with necessary G.I. reducing socket 40mm X 20mm. Size locking arrangement with h'inged cover plate, funnel, G.I. nuts, through bolts etc. for putting pipe and re-fitting with necessary enclosure on the top etc. as
22.12 Extra for using salt (5kg) and charcoal (64kg) for pipe earth electrode as required.
22.1 Installation of earth stations with necessary earthplate including providing all accessories masonary enclosure with cover plate having locking arrangement and 20mm dia. G.I. pipe watering pipe with funnel, G.I. bolts, nuts, checknuts etc. but without Charcoal or cock and with 600mm X 600mm X 3mm. thick (10.5 kg. approx) Copper earth plate.
21.2(c ) Extra for Charcoal (96k.g) and salt (5kg) for G.I. Copper plate earth electrode as required
22.23 Supplying and laying G.I. strips 0.50 metre below ground level as strip earth electrodes including soldering excavation work and refilling etc. as with 25mm X 4mm G.I. strip
22.24 Supplying and laying 25mm X 4mm size Copper strip in 40mm dia G.I. pipe from earth electrodes including providing and fixing necessary bend etc. including soldering excavation work as refilling etc. as required complete.
22.25 Providing and fixing 25mm X 4mm. Copper strip on surface or in recessed fitted with necessary copper saddles including connection etc.
22.28 Providing and fixing 25mm X 4mm G.I strip on surface or in recess earth connection fitted with necessa G.t Saddles including connection etc.
22.31 Providing and fixing of lightning conductor finial made of 25mm. Dia 300mm long copper tube having single prongat top with 85mm dia. 3mm thick copper base plate including making hole
22.29 Providing and fixing G.I. strip 20mm X 3mm thicks on parapet and surface or wall for lightning (a) For horizontal runs
22.29 Providing and fixing G.I. strip 20mm X 3mm thicks on parapet and surface or wall for lightning (b) For vertical runs
Ceiling fan, Exhaust fan & Cabin fan (All PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 27.1.6 Supplying including fitting fixing of high speed A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections etc,. as required complete and as directed by the Department. (a) 1200 mm sweep
27.2.1.8 Supplying including fitting fixing of A.C. Exhaust fan in the existing hole on the wall of following sweeps and making necessary connections etc. as required complete and as directed by the department. (a) Domestic (i) 300mm sweep
27.4 Supplying including fitting of swing wall fan complete with all accessories and making necessary connections etc. as required completeand as directed by the department.
14.1 Supplying fitting and fixing industrial plug & Socket in durface mounting SP sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar complete with making necessary connection etc. as specified and directed by the deptt. [legrand/merlin gerin/
15.6.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted double door surface mounting SPN MCB DB (IP-43 protection) incorporated with bas-bar, Neutral link, earth bar and din rail etc. fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as specified and directed by the deptt. (a) 4 way SPN Double Door
15.8.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.8.1 ABB, Schneider MG, legrand, Hager make) 15.8.1.1 4way TPN (4+12) double door.
6.1 Supplying with fitting and fixing single pole 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415Hz MCB (a) 6A
6.1 Supplying with fitting and fixing single pole 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415Hz MCB (c ) 16A
6.1 Supplying with fitting and fixing single pole 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. [Legrand/Merlin Gerin/Hagger make] A. B Series 1. Single Pole 10KA 240/415Hz MCB (d ) 20A
16.3.2 Supplying with fitting and fixing DP 10KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. 1. DP 10KA 240/415 50Hz MCB (C series) (d) 25A
16.7.1 Supplying with fitting and fixing 100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as specifeid and directed 1. 300mA sensitivity 440/415 50Hz 4p RCCB (b) 40A
16.6 Supplying with fitting and fixing 4 Pole 10 KA 415V 50Hz MCB of the following capacity complete with making necessary connection as specified and directed by the deptt. 1.4 Pole 10KA 240/415 50Hz MCB (f) 40A
U.G. POWER CABLE LAID THROUGH GROUND (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) 32.1.3.4 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in ground/partially in air (10.0% of cable length) including excavation of cable trench upto depth of 75cm, refilling, protective brick covering, sand cushioning etc. complete handling of (d) 70.00mm 3and1/2 core U.G. cable
32.5.3.4 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 11KV gd aluminium conductor LT armoured U.G. cable laid in pucca flooring road crossing, drain crossing and partially in air through G.I. Pipe (Tata/Nezone make) with necy bend and socket including excavation and refilling the treance and making (d) 70 sqm 3 1/2 core U.G. cable in 50mm dia medium quality G.I. Pipe.
23.1.6 Supplying, installation, testing and commissioning of the following prewired CFL/Flourescent luminaries complete with all accessories such as ballast, starter etc. directly on wall/ceilling including connection with 1.5 sq.mm PVC insulated single core copper conductor as reqd. (d) (iii) Box type luminaries with copper ballast and 1 X 36 watt. Flourescent tube. (Havells make)
Supply & Installation of LT cable route marker with inscription, bolted/welded to 35cm X 35cm X 6mm iron, 60cm long of following sizes. 150mm dia CI marker
Supply installation testing and commissioning of brass bed side light of make decon cat no. 05 BT or equivalent including supply of 1 X 60w GLS.
Recessed type night lamp/Skirting Light of reputed make with 1no. Of 15W incandescent lamp (milky lamp). (NL)
Supply installation testing and commissioning of compact flourescent fittings with powder coated CRCA sheet steel housing with opal acrylic diffuser and decorative end plates of make Bajaj Cat No. BJEXL 111 or equivalent with 1
External Electrification Works: 32.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV grade solid standed conductor XLPE insulated, cores laid up, PVC tape inner sheathed, Armour(Aluminium for single core upto 70sq. mm balance Allminium strip, Galvanised for cables up to 2 X 10 sq.mm, 3 X 10 sq. mm, 4 x 6 sq.mm balance all galvanized steel strip) , extruded PVC type ST2 sheathed, 650/1100 V Graded as per IS 7908(Part - I) 1988 armoured U.G. cable U.G cable laid in ground/partically in air (as required for termination over ground including excavation of cable trench up to depth of 75 cm, refilling, protective brick covering, sand cushioning etc. complete handling of surplus spoil, debris etc. to proper place as specified and directed by the deptt. (NICCO/Havells/RPG/CCI/Polycab/Gloster/Finolex make or equivalent) 32.1.1 2 core A2XWaY A2XFaY. 32.1.1.1 4.00 sq.mm 2core armoured U.G. cable.
32.1.1.2 6.00 sq.mm 2core armoured U.G. cable.
ECBC 3.25 Supplying and fixing of jaquar or equivalent Philips/ Wipro LED outdoor light fittings complete with all accessories including connection cable as approved by the deptt. Etc. as required. ECBC 3.25.3 LED Garden Light 12W/16W.
Supplying with fitting and fixing of three phase Digital type Energy Metre with ASEB Tested service connection including load security, metre security connection charge etc. complete with all necessary materials and accessories as required and specified by the department.
Cast in situ Cement concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165mm respectively, 250mm high in M20grade PCC on M10 grade foundation 150mm thick , foundation having 50mm projection beyond kerb stone, kerb stone laid with kerb laying machine , foundation concrete using concrete mixer
5.7.4.3 Providing polished OMI'S INTERLOCKING PAVERS tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessaryfinished with flush pointing with Fix-A Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment (a) 60mm thick
20.12 Supplying and planting of ornamental trees (plant sapling height '1-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (A) Neem/Bakul/Kadam/Palash/Ajar/Gulmohar
20.12 Supplying and planting of ornamental trees (plant sapling height '1-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (B) kanchan/Nahar
20.12 Supplying and planting of ornamental trees (plant sapling height '1-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (C ) Sonaru
20.12 Supplying and planting of ornamental trees (plant sapling height '1-0") including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (D ) Nil Gulmohar/Debdaru
20.13 Supplying and planting of ornamental shurb (plant sapling height 1'-0" ) including pit making (60cm X 60cm X 60cm), filling the pit with appropriate soil media, manure and fertilizers and necessary maintenance for a period of one year from the date of planting complete as specified and directed. (B) Togor
19.6.5 Providing and laying non-pressure NP 2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including tetsting of (i) 450mm dia
1.6 Supplying and filling sand gravel in foundation trenches of column footings over slushy soil including local carriage of material within 8 km pumping out of water, ramming etc. complete for strengthening the bearing capacity of the soil as directed and specified including payment of Forest Royalty and Sales Tax and other duties and taxes as may be necessary.
1.7 Extra lead per km truck carriage for sand gravel beyond thr initial lead of 8km (extra 10km)
Boundary wall 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. (b) In hard/dense soil Foundation of RCC column
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 1. Foundation of RCC column.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 2. Under tie beams
2.12(ii) 1. in coping over columns
2.12(ii) 2. in coping over wall
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft amd mass concrete works etc. (i) Using 38mm thick plank 1. Foundation base of RCC column
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft amd mass concrete works etc. (i) Using 38mm thick plank 2. Tie beam sides.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 1. RCC columns upto tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 2. RCC columns above tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 3. In coping bottom
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 4. in coping sides.
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 1. Foundation base
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 2. Column
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Column stirrups
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Tie beam main bars
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Tie beam stirrups
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 1. column base
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 2. column base taperred portion
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 3. Column upto tie beam
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 4. In tie beam
5.2 (ii) In super structure from plinth level up to 1st floor level. (b) Columns, pillars, posts, structs, suspended floor, roof, landing, sheld and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surface and furnishing and nosing. columns
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (a) In proportion 1:5 ( 1 cement : 5 sand) 4.1.5 115 thick
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 1. Wall
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 2. copping top
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 3. copping sides
13.2.3 (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.2 Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
Boundary wall gate 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. (b) In hard/dense soil Foundation of RCC column
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 1. Foundation of RCC column.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately ) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume. 2. Under tie beams
2.12(ii) 2. in coping over columns
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft amd mass concrete works etc. (i) Using 38mm thick plank 1. Foundation base of RCC column
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft amd mass concrete works etc. (i) Using 38mm thick plank 2. Tie beam sides.
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 1. RCC columns upto tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 2. RCC columns above tie beam
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 3. In coping bottom
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.3 Columns, pillars, posts, structs (i) Using 38mm thick plank 4. in coping sides.
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 1. Foundation base
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 2. Column
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Column stirrups upto soffits of 2nd tie beam
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Tie beam main bars
18.1.1 Supplying, fitting and fixing in position (b) TMT bar (i) TATA/SAIL 3. Tie beam stirrups
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 1. column base
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 2. column base taperred portion
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 3. Column upto tie beam
2.2.2 Providing and laying plain/reinforced cement croncrete works in prop 1:1.5:3(1 cement :1.5 coarse sand : 3 graded stone chips, 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (i) In substructure up to plinth level Foundation , footing, columns with base tie and plinth beam, pile cap, base cap, retaing walls, walls of septic tank, inspection pit and and the like and other not less than 100mm thick up to plinth level. 4. In tie beam
5.2 (ii) In super structure from plinth level up to 1st floor level. (b) Columns, pillars, posts, structs, suspended floor, roof, landing, sheld and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surface and furnishing and nosing. columns
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 1. Sides
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 2. copping top
6.2.5 20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10 mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal round angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:3 3. copping sides
13.2.3 (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.9.2 Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats).
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Ornamental grill Fixed to brickwork/PCC/RCC 1. 12mm square bars.
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Ornamental grill Fixed to brickwork/PCC/RCC 2. 48 X 96 RHS horizontals
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Ornamental grill Fixed to brickwork/PCC/RCC 3. 48 X 96 RHS verticals
10.2 Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with round headed bolts and nuts or screws. Ornamental grill Fixed to brickwork/PCC/RCC 4. 48 X 96 RHS rail
13.7.2 + 13.7.4 Painting two coats ( including priming coats) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/ J& Npaint/Nerolac) and bushing to give an even shade including cleaning the surface of all dart, dust and other matter. Surface over 100mm in wdith or girth
1.1 RAISING LOW SITE: Raising low site around the building with approved soil obtained from outside by truck carriage includingbreaking clods, dressing etc. complete including paying nessary forest royalty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shinkage to be made from b. Other than Guwahati city.
DEEP TUBE WELL & IRON REMOVAL WATER FILTER: 5.3.2 Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00 after first 3.00 depth and delivering the same in nearest P.W.D. camp in the small tin container (container scaffolding tools etc. will have to be arranged by the contractor at his own cost).
5.3.4 Labour for boring hole for inserting tube pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the department. (vi) Bore hole of 200mm diameter
5.3.5 Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II. PVC pipe SUPREME/PRINCE/FUSION/SFMC Brand (vii) 160mm diameter
5.3.6 Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevent IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes concentrically in the casing pipes complete as directed. A. GI. Pipe a) TATA/SAIL (Medium) socket should be welded to the pipes. (iv) 50mm diameter
5.3.8 Supplying fitting and fixing brass Tez filter 2.00 metre long
5.3.11 Supplying fitting and fixing check valve (non return valve)including thread to pipes. (iv) 50mm diameter
5.3.12 Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
5.3.13 Flushing, clearing, washing and watering of the tube well
6.3.2 Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour DOLPHIN make with all necessary fittings such as valve,bib cock, pipe connection etc. with a free maintanance period of six months. (A) With Zoloto fittings (I) 1000 liters capacity (a) 4mm thick Vessel.
39.3.6 5 HP single phase centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter (Crompton/Greaves/Control & switch Gear/BCH/ L&T/Siemens make)
DHANANJAY BASUMATARY
SRI ZANDER BRAHMA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .