Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC MANDIR ROAD NEW ABADI AKALGARH AIR FORCE STATION HALWARA TEH RAIKOT DISTT LUDHIANA PB 141106 | LUDHIANA | LUDHIANA | PUNJAB | 141106 | ₹30.1 L Quoted ₹33.4 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹34.4 L+₹1.0 L (3.06%)Rejected-Finance RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | ₹34.4 L+₹1.0 L (3.06%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹40.7 L+₹7.3 L (21.9%)Rejected-Finance | ₹40.7 L+₹7.3 L (21.9%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹43.4 L+₹10.0 L (30.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹43.4 L+₹10.0 L (30.0%) | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Dec 2023, 6:00 pmClosed
GE (AF) Halwara
GE (AF) Halwara
REPAIR/MAINT OF SEWAGE PUMP MOTOR, STARTER PANEL AND MISC E/M WORKS IN DOMESTIC AND TECH AREA AT AF STN HALWARA
2023_MES_623726_1
GE/HAL-44/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a(ii)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹80,000
Yes
5 Jan 2024
17 Oct 2023
6 Dec 2023
17 Oct 2023
4 Dec 2023
20 Nov 2023
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5M in depth for laying of GI/DI/CI pipe lines etc, getting out including forming bottom surface to required level and gradient in soft / loose soil complete all as specified.
Returning and filling in excavated soil including spreading, leveling, watering, well ramming in layers not exc 25 cm thick complete all as specified.
Removing of excavated materials not exceeding 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for repair to rubber gasket joint of 80mm bore CI pipe including jointing materials complete all as specified Note :- Excavation and earth work will be measured and paid separately if repair carried out for joint only.
All as per Srl item No. 4.00 above but 100 mm bore.
All as per Srl item No. 4.00 above but 150 mm bore.
All as per Srl item No. 4.00 above but 200 mm bore.
Repairs to 80mm dia sluice valves such as replacement of unserviceable/warnout gland on stuffing box, rubber gasket of suitable size, filling or grinding to gate valve, replacement of worn out check nut, cleaning inside gate valve properly and remove scaling and other waste materials, replacement of worn out nut/bolts with washers including testing of leakage and operation complete all as specified and directed.
All as per Srl item No. 8.00 above but 100 mm dia
All as per Srl item No. 8.00 above but 150 mm dia
All as per Srl item No. 8.00 above but 200 mm dia.
All as per Srl item No. 8.00 above but 300 mm dia.
Disconnecting and removing the unserviceable/wornout spindle from sluice valve 80 mm dia after opening the nut and bolts and replace the same with new brass spindle of same size, length and turns including necessary fixing arrangements, testing and commissioning complete all as specified and directed.
All as per Sl item No 13.00 above but 100mm dia
All as per Sl item No 13.00 above but 150mm dia
All as per Sl item No 13.00 above but 200mm dia
All as per Sl item No 13.00 above but 300mm dia
S&F cast iron sluice valve 80mm dia both end flanged with brass spindle and cast iron handle wheel, heavy duty, class PN-1.0 (ISI marked) and fixing with existing pipe line including jointing material nuts,bolts, washers & gasket as in replacement complete all as specified.
All as per Srl item No. 18.00 above but 100mm dia
All as per Srl item No. 18.00 above but 150mm dia
All as per Srl item No. 18.00 above but 300mm dia
Taking out existing CI pipe 80mm bore (including all fittings) with spigot and socket ends and lead joints / flange joint including burning out joints and recovering lead from the ground cleaning the pipes free from sedimentation/scaling etc for reusing the serviceable pipes complete all as specified. Note :- Excavation and earth work will be measured and paid separately.
All as per Srl item No. 22.00 above but 100 mm bore.
All as per Srl item No. 22.00 above but 150 mm bore.
Laying only cast iron pipes 80mm bore complete all as specified and directed. Notes : (i) Serviceable pipes obtained from dismantling shall be reused in the work after cleaning. (ii) Joints and jointing material shall be measured seperately.
All as per Srl item No. 25.00 above but 100 mm bore
All as per Srl item No. 25.00 above but 150 mm bore
M&L for CI pipe 100mm bore with spiogt and socket ends centrifugally cast, class LA suitable, in any length, laid in trenches including necessary cut to length to match the existing fitting/pipes complete all as specified and as directed.
All as per Srl item No. 28.00 above but 150 mm bore.
Cutting the 100mm bore CI pipe for insertion of new CI specials such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc to reduce the length in position complete all as specified and directed.
All as per Srl item No. 30.00 above but 150 mm bore.
M&L for CI/GI specials such as bends, tees, collars tail pieces flanges, etc complete suitable for CI/GI mains upto 200 mm sizes complete all as specified and directed
M&L for cast iron double flanged non slam round type non return valve 80mm dia with by pass arrangements (ISI marked) heavy duty confirming to IS-5312 Part I / 84 of pressure rating PN 1.0 as in replacement complete all as specified.
All as per Srl item No. 33.00 above but 100 mm dia
All as per Srl item No. 33.00 above but 150mm dia
All as per Srl item No. 33.00 above but 200mm dia
S&F cast Iron flanged type foot valve 80 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainer, nuts, bolts, washers etc as in replacement complete all as specified.
S&F cast Iron flanged type foot valve 100 mm bore with drilled flanged end all as per IS : 4038 with Cast Iron Strainer nuts, bolts, washers etc as in replacement complete all as specified and directed
Taking up or down steel water GI tubing 80mm bore and connections including cleaning the pipes free from scaling for reusing the same complete all as specified and directed.
All as per Srl item No. 39.00 above but 100 mm bore.
M&L for supply and laying steel water tubing GI medium grade 80mm bore ISI marked with all fittings laid in trenches or fixed to wall etc complete all as specified. Note :- Excavation and earth work will be measured and paid separately.
All as per Srl item No. 41.00 above but 100mm bore.
Taking up or down 100mm bore existing centrifugally cast (spun) ductile iron pressure pipes for water with socket and spigot ends suitable for rubber gasket pushon joining complete all as specified and directed.
All as per Srl item No. 43.00 above but 150 mm bore
All as per Srl item No. 43.00 above but 300 mm bore
Supply and laying 100 mm bore centrifugally cast (spun) ductile iron pressure pipes for water with socket and spitot ends suitable for rubber gasket pushon joining confirming to IS 8329:2000 having inside cement mortar lining and outside zinc coating with finishing layer of blue epoxy in standard length, classification K-9 in standard length of 5.50/6.0 mtrs including push on joints with cement mortar lining complete all as specified and directed.
All as per Srl item No. 46.00 above but 150 mm bore
All as per Srl item No. 46.00 above but 300 mm bore
S&F in repairs 25mm bore dia Gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed complete all as specified and directed.
All as per Srl item No. 49.00 above but 40mm bore dia
All as per Srl item No. 49.00 above but 50mm bore dia
S&F MS column pipe medium grade of size 100mm dia 10' long flanged both ends and slot made for submersible cable as in replacement complete all as specified and directed.
All as per Srl item No. 52.00 above but 125mm bore.
Opening and disconnecting centrifugal pump from electric motor 20 HP capacity, including shifting, transportation, overhauling shaft metering, welding , brazing and grinding the shaft and replacing of worn out parts and re-assembling and connecting it to the electric motor complete all as directed by EIC. Note : (i) The unit rate shall include for minor spares such as bolts, nuts washers, oil seal, gasket, greasing etc as required. (ii) Major spares as required shall be measured and paid for separately.
All as per Srl item No. 54.00 above but 5 to 12.5 HP
All as per Srl item No. 54.00 above but 0.5 to 3.00 HP including booster motor
Rewinding of electric motor of capacity upto 5 HP for centrifugal non clog pumping set with supper enameled copper winding wire of existing gauge, size and weight with insulating material, all as specified. Note :- Motor of any site undergone repair/ rewinding will be liable for repair again free of cost incase of same fault occuring during the engagement of contract Repair/ Rewinding of the motor will be measured only once for a particular site/ motor. The downtime at site/ time required for repair of motor if is more than 24 hrs, the contractor will be liable to provide & install a standby motor at site during the downtime with no extra cost to the department failing to this the contractor will be liable to a penalty of Rs. 500/- every hour post 24 hrs repair timeline.
All as per item No 57.00 above but for but 12.5 HP
All as per item No 57.00 above but 20 HP
Supply & fixing MS coupling with rubber bush and coupling nuts & bolts for 20 HP non clog pumping set complete all as specified and directed.
Supply & fixing Impeller GM for 20 HP CF pumping set complete all as specified and directed.
Supply& fixing Gland box for 20 HP CF pumping set complete all as specified and directed.
Supply& fixing ball bearing for 20 HP non clog pumping set complete all as specified and directed.
Supply & fixing in replacement Ball bearing of electric motor upto 12.5 HP capacity complete all as specified and directed.
Supply & fixing in replacement Gun metal bushes of pump upto 12.5 HP capacity complete all as specified and directed.
Supply & fixing in replacement MS coupling of pump upto 12.5 HP complete all as specified and directed.
Supply & fixing in replacement Ball bearing of electric motor upto 5 HP capacity complete all as specified and directed.
Supply & fixing in replacement Gun metal bushes of pump upto 5 HP capacity complete all as specified and directed.
Supply & fixing in replacement Rubber coupling of pump upto 5 HP complete all as specified and directed..
Supply and fix in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel)enclosure with Surge protection device, Single phase preventor, 230-400 V Coil Overload relay range 3.8/6.0 A Back up Fuse (A)20 Suitable for Submersible motor upto capacity 3 HP complete all as specified and directed
Supply and fix in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel)enclosure with Surge protection device, Single phase preventor, 230-400 V Coil Overload relay range 6.0/9.3/3.8 A Back up Fuse (A)25 suitable for Submersible motor capacity 7.5HP complete all as specified and directed
Supply and fix in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel) enclosure 8.9-13.5 A with 230-400 V Coil Overload relay suitable for CF Pump upto 10 HP complete all as specified and directed
Supply and fix in replacement fully automatic Auto start Direct on Line starter in SS (stainless Steel) enclosure 6.0-9.3 A with Surge protection device, Single phase preventor, 230-400 V Coil Overload relay suitable for CF Pump upto 20 HP complete all as specified and directed.
Supply and fixing in replacement single phase 1.5 HP relay 8.9-13.5 contactor rating 16 Amp SPS with 2P contactor + overload relay (Ammeter+Voltmeter) wiogh 160-220 V AC coil complete all as specified and directed
Supply only 2.5 sqmm single core cable life line plus S3 Yellow HRFR PVC flexible cable complete all as specified and directed.
Supply and fixing in replacement of Isolator single pole 32 Amp complete all as specified and directed.
Supply and fixing in replacement MCB SPN 06 to 40 Amp 415 V including all terminals fitting etc complete all as specified and directed.
Supply and fixing in replacement single core PVC insulated unsheathed stranded copper FR conductor of size 06 sqmm 1100 volt grade confirming to IS 694-1`990 complete all as specified and directed.
All as per item No 78 here-in-before for but size 10 Sqmm
All as per item No 78 here-in-before for but size 16 Sqmm
S&F First Aid chart with clear glass cover & wooden frame as per sample kept in AGE E/M Office complete all as specified and directed .
All as per Sl item No 81 above but shock treatement chart.
Supply Only First Aid Kit box No-08 (Size : 360 mm x 150 mm x 80 mm) caintaining following items complete all as specified and directed :- (a) Dettols bottle100 ml 02 bottles (b)Antiseptic Ointment 100 mg © Crocin tabletes 01 strips ( containings 10 Tablets each). (d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos (f) Cotten strip small roll 04 Nos (g)Moove tube 01 Nos (h) Betadine Tube 100 mg
S&F Submersible Cable 2.5Sq mm flat Three Core PVC Insulated & PVC Sheathed copper conductor 1100 Volts for Submersible Pump Moter complete all as specified and directed
All as per item No 84 here-in-before for but 4 Sqmm.
All as per item No 84 here-in-before for but 6 Sqmm.
All as per item No 84 here-in-before for but 10 Sqmm.
All as per item No 84 here-in-before for but 16 Sqmm.
S & F Ammeter 25 A for three phase submersible pump starter complete all as specified and directed.
S & F Ammeter 50 A for three phase submersible pump starter complete all as specified and directed.
S & F volt meter 0-500 volts for three phase submersible pump starter complete all as specified and directed.
S & F volt meter 0-300 volts for three phase submersible pump starter complete all as specified and directed.
S & F in replacement MCCB 4 Pole 63A breaking capacity ICU at 415 (18KA) complete all as specified and directed.
S & F in replacement MCCB 4 Pole 100A breaking capacity ICU at 415 (36KA) complete all as specified and directed.
S & F in replacement MCCB 4 Pole 125A breaking capacity ICU at 415 (36KA) complete all as specified and directed.
S & F in replacement MCCB 4 Pole 160A breaking capacity ICU at 415 (25KA) complete all as specified and directed.
S & F in replacement MCCB 3 Pole 100A breaking capacity ICU at 415 (18KA) complete all as specified and directed.
S & F in replacement MCCB 3 Pole 63A breaking capacity ICU at 415 (18KA) complete all as specified and directed.
S & F in replacement off load change over switch AC-21 100 Amp side handle in sheet encloser, 415 V AC, 50 Hz complete all as specified and directed.
S & F in replacement off load change over switch 160A AC-23 side handle in sheet encloser, 415 V AC, 50 Hz complete all as specified and directed.
S & F in replacement off load change over switch AC-21 200 Amp side handle in sheet encloser, 415 V AC, 50 Hz complete all as specified and directed.
S & F power contactor 3 pole AC control AC-3 rating 32 Amps (20 HP/15KW) 415 volts including Aux contact 1 No + NC with colil voltage 380/415 volts as in replacement complete all as speciied and directed.
S & F power contactor 3 pole AC control AC-3 rating 40 Amps (20 HP/15KW) 415 volts including Aux contact 1 No + NC with colil voltage 380/415 volts as in replacement complete all as speciied and directed.
S & F power contactor 3 pole AC control AC-3 rating 63 Amps (50 HP) 415 volts including Aux contact 1 No + NC with colil voltage 380/415 volts as in replacement complete all as speciied and directed.
S & F Electronic timer for three phase submersible pump starter as in replacement complete all as speciied and directed.
S&F in replacement PVC (heavy)duty electric cables with copper Conductor 1100 volts cross section area 6 sqmm 3 core complete all as specified and directed.
M&L for boring under road/path/hard standing to pass the Pipe lines upto 150mm dia bore with the own arrangement of T&P complete all as specified and directed.
S&F copper thimbles of size 6 sqmm to 25 sqmm conductor as in replacement complete all as speciied and directed.
S&F Alluminium thimbles of size 6 sqmm to 35 sqmm conductor as inreplacement complete all as specified and directed.
M&L for preparation of old painted surface of steel over 10 cm width or girth and applying one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed Note : Colour of paint shall be stricity as per existing colour.
S&F distribution chart / electronic board for water/electrical distribution network to the writing letter locations complete all as specified and directed.
Supply, fabrication and fixing in replacement mild steel work conforming to Fe-290, E-165 as in framed grills, gratings, framed guard bars, ladder, framework of volve pit cover, water tanks etc or similar work as ordered and febricated from MS rolled section of any size and shape as complete all as specified and directed. Note: MS sheet where required shall be measured and paid seperately.
S&F mild steel plate / sheet plain or chequered 3.00mm thick cut to piece as required and fixed to MS frame work be means of electric arc / gas welding complete all as specified and directed.
M&L for masonary valve pit of size 1.2mx1.2mx1.1m (internal size) using 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate for foundation, 230mm thick brick wall with sub class `B’ bricks built in CM 1:6, 40mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate for coping, 15mm rendering in CM (1:4) on internal surfaces, 15mm thick rendering in CM 1:6 on external surfaces including provision of MS sheet cover 2mm thick fixed to MS angle frame made of 50x50x6mm thick and applying 2 coats of synthetic enamel paint over one coat of red oxide primer to steel surfaces and making locking arrangements including dismantling old unserviceable valve pit with necessary excavation and earth work in any type of soil complete, all as specified and directed.
All as per item No 114 above but Size 0.9mx0.9mx.86m.
Supply, installation, testing and commissioning in replacement LT panel, indoor cubical type whether and vermin proof totally enclosed made out of 3.00 mm thick CRCA sheet machine preesed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz with front and rear openable with locking arrangement incl shutters for mounting switchgear etc, bottom gland plate with sufficient numbers of circular cable entry holes, prewired complete duly powder coated with 7 tank process mounted on agle iron stand made out of angle size 50 x 50 x 6 mm grouted in PCC (1:3:6) 450mm above ground level, 400 mm below ground level comprising with following complete all as specified :- (a) Bus bar strip, four pole and capacity 500 Amps copper strip size be based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc. (b) Indicator with LED lamps for RYB, 3 phase with MCBs set of three-01 Set INCOMING (a) MCCB 250 Amp, 415 V, 25 KA, 4 pole with microprocessor release - 01 Nos (b) Panel meter of size 96 x 96 mm with LCD display, accuracy class 1.0, having parameters voltage, current, frequency, power factor, power & energy with RS 485 including suitable CT complete all as specified, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete. OUTGOING (a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with adjustable thermal magnetic release-02 Nos (b) Onload changeover switch 250 A, 4P 415 V open execution type -01 . (c) MCB SPN 32 Amp, 240 V, 10 KA, 02 Nos. (d) MPCB 100 A -01. (e) SP preventor- 01. (f) Automatic Star delta starter three phase 36-80A-01 Nos.
Supply, installation, testing and commissioning in replacement LT panel, indoor cubical type whether and vermin proof totally enclosed made out of 3.00 mm thick CRCA sheet machine preesed of suitable size, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz with front and rear openable with locking arrangement incl shutters for mounting switchgear etc, bottom gland plate with sufficient numbers of circular cable entry holes, prewired complete duly powder coated with 7 tank process mounted on agle iron stand made out of angle size 50 x 50 x 6 mm grouted in PCC (1:3:6) 450mm above ground level, 400 mm below ground level comprising with following complete all as specified :- (a) Bus bar strip, four pole and capacity 250 Amps copper strip size be based on 1.5 Amps per sqmm, coloured with plastic coated insulated and sleaves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts and bolts and washers etc. (b) Indicator with LED lamps for RYB, 3 phase with MCBs set of three-01 Set INCOMING (a) MCCB 125 Amp, 415 V, 25 KA, 4 pole with microprocessor release - 01 Nos (b) Panel meter of size 96 x 96 mm with LCD display, accuracy class 1.0, having parameters voltage, current, frequency, power factor, power & energy with RS 485 including suitable CT complete all as specified, duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete. OUTGOING (a) MCCB 100 Amp, 415 V, 25 KA, 4 pole with adjustable thermal magnetic release-02 Nos . (b) Onload changeover switch 100 A, 4P 415 V open execution type -01 . (c) MCB SPN 32 Amp, 240 V, 10 KA, 02 Nos. (d) MPCB 63 A -01. (e) SP preventor- 02. (f) Automatic start Direct on Line starter three phase 15-30A-02 Nos. (g) MCB TPN Four pole 63 Amp, 240 V, 10 KA, 02 Nos.
M&L for Earthing complete in replacement for LT Panel / Feeder Pillars with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level earth plate surrounded by 15cm thick and packed with layer of charcoal dust and common salt earth lead GI strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end connecions to main switch board and protected by galvanised iron light grade 50mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover (1:2:4) type B-1 using 20mm graded stone aggregate and 8mm dia TMT bar @ 10cm c/c both way including MS frame using MS angle of size 45mmx4mmx5mm complete all as specified and shown in electrical plate No-5 in MES Schedule (Part-I).Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position.(Earth wire and protection pipe upto 7.50m length is included in the unit rate)
M&L for replacement energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 60 watt LED for building security lights with high efficiency electronic driver BIS approved, having IP-65/66 protection, surge protection min 2 KV power factor more than 0.9 complete operative on AC supply 140 volts to 270 volts pre-wired and product should be made in India only including GI pipe medium grade 40mm dia 1.2 mtr long bend to shape as required and fixing with two nos MS clamp of size 40x6mm for fixing of street light fitting complete all as specified and directed. Note : (i) Contractor shall provide 2 years written manufacture's guarntee for the LED fixture complete including driver from the certified date of completion. (ii) Contractor shall produce LM-79 & LM-80 report of NABL accredited laboratory from manufacturer's.
Bailing out sludge water from sludge tank/sewage sump by using pumping set/mechanical suction and disposing off the same to a distance not less than 500 metres away from site complete all as specified and directed.
Bailing out mud/sludge from sewage tank/sump by using any mechnaincal means/ sewer suction cum jetting machine and removing sludge at the bottom of the tank & throwing away upto 500 metres from site including washing the sewage tank/ sump using normal clean water thoroughly & recleaning the same using pumping machine & throwing dirty water away not less than 500 mtr from the site post cleaning of the sump and applying one coat of white wash the entire sump/ tank using lime complete all as specified and directed. Note:- (i) Skilled supervisor shall be deputed on site by the contractor during sump cleaning & included in quoted rates. (ii) While desludging / taking out water / cleaning / painting of the sewage tank/ sump, alternate arrangements to ensure unhindered sewage flow/ storage of sewage line to be made by the contractor & the rate of the same be deemed to includied in the quoted rates.
Supply, laying and testing 25 Sqmm 4 core 1100 volts aluminium conductor cable XLPE insulated screened PVC bedded , galvanised steel strip of wire armoured , electric power cable (heavy duty) laid in trenches and through ducts including testing and taking down old unserviceable cable complete all as specified and as directed.
All as per Sl item No 122 above but 35 Sqmm 4 core
All as per Sl item No 122 above but 70 Sqmm 4 core
Supplying and laying bricks common brunt clay building bricks sub class B as protection to cables including removing of old bricks complete all as specified and directed.
Surface dressing,cleaning, grass/tree cutting and removing of raw material and labour for sand cushioing with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning down shall be considered for payment.
S & F in replacement TPN MCB,4 pole, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 40 to 63 Amps complete all as specified & directed.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of struts, PCC blocks including necessary form work and fair finish to exposed surfaces without using extra cement etc, complete all as specified and directed.
Surface dressing and cleaning sludge from the 03 Nos oxidation pond of size 149.70m x 62.20m twice during the currency of contract period, removal of rotten solid waste from the pond & providing a layer of sand cushioning (Qty of sand not less than 10.00 Cum to be laid & spreaded at every time after cleaning of pond ) at the site as directed by Engr-in-Charge. The vegetation around the oxidation ponds to be cleaned and make up of broken/ distorted boundaries of the pond, the cost of all these is deemed to be included in quoted rates without any additional charge to the Govt. The sludge removed from the oxidation pond shall be removed and deposted at locations as directed by Engr-in-Charge.
M&L for replacement of Sub main wiring with PVC insulated cable copper conductor FRLS two single core 4 Sqmm drawn through existing or new PVC rigid non metallic conduit including earth continuity FRLS copper conductor 4 Sqmm PVC insulated with green insulation complete all as specified. Note : PVC conduit shall be measured and paid separately.
M&L for replacement of 25mm dia PVC rigid non metallic conduit fire proof medium grade, surface or concealed including conduit accessories such as tee, elbow ,bend junction box complete all as specified. Note : Cutting chases where ever required and making good is deemed to be included in the quoted rates.
M/S SANGA SINGH AND CO
M/S MG GROUP
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .