Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC Awarded to lowest | |
| 2 | L2₹12.7 L+₹61,255 (5.05%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹13.3 L+₹1.2 L (9.76%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹13.5 L+₹1.3 L (11.0%)Rejected-Finance | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | Sourab Kuthiala L2 | upvinder kumar L1 | KISHORI LAL SHARMA GOVT. CONTRACTOR L4 | M/s Jamwal nxt gen energy solutions L3 |
|---|---|---|---|---|---|---|---|
| 1.00Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus) | |||||||
| 1.10 | Group C | 223 | P/Pt | 1,600 ₹3,56,800 | 1,525 ₹3,40,075 Lowest | 1,600 ₹3,56,800 | 1,650 ₹3,67,950 |
| 2.00Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus) | |||||||
| 2.10 | Group C | 6 | P/Pt | 1,600 ₹9,600 | 1,550 ₹9,300 Lowest | 1,600 ₹9,600 | 1,600 ₹9,600 |
| 3.00 | Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI/SCI/Havells/Plaza) | 115 | P/Mtr | 250 ₹28,750 | 220 ₹25,300 Lowest | 275 ₹31,625 | 280 ₹32,200 |
| 4.00 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI/SCI/Havells/Plaza) | 85 | P/Mtr | 300 ₹25,500 | 290 ₹24,650 Lowest | 362 ₹30,770 | 320 ₹27,200 |
| 5.00 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Make:-KEI/SCI/Havells/Plaza) | 20 | P/Mtr | 450 ₹9,000 | 440 ₹8,800 Lowest | 542 ₹10,840 | 450 ₹9,000 |
| 6.00Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-KEI/SCI/Havells/Plaza) | |||||||
| 6.10 | 2x2.5 Sq. mm. | 140 | P/Mtr | 270 ₹37,800 | 250 ₹35,000 Lowest | 320 ₹44,800 | 320 ₹44,800 |
| 6.20 | 2x10 Sq. mm. | 40 | P/Mtr | 500 ₹20,000 | 490 ₹19,600 | 620 ₹24,800 | 420 ₹16,800 Lowest |
Tender Value
₹9.8 L
EMD Value
₹20,000
Closing Date
21 Feb 2022, 10:00 amClosed
Executive Engineer
Elect. Division HPPWD Palampur
C/O Govt. Degree College at Dhaliara (Admin. Cum Academic Block-B) in Tehsil Dehra Distt. Kangra (HP) (SH- Providing E.I. therein)
2022_PWD_56705_3
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Dhaliara in Teh. Dehra
Please refer Tender documents.
10 documents required · 10 mandatory
₹350
₹20,000
25 Sept 2026
11 Feb 2022
21 Feb 2022
11 Feb 2022
21 Feb 2022
11 Feb 2022
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Group C
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.(Make:-KEI,Anchor,L&T )Legrand (Myrius),L&T(Oris),Anchor(Roma plus)
Group C
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI/SCI/Havells/Plaza)
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI/SCI/Havells/Plaza)
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. (Make:-KEI/SCI/Havells/Plaza)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(Make:-KEI/SCI/Havells/Plaza)
2x2.5 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.16 Sq.mm. (4x16+2x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(Make:-KEI/SCI/Havells/Plaza)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(Make:-KEI/SCI/Havells/Plaza)
3x1.5 Sq. mm.
3x2.5 Sq. mm.
3x4 Sq. mm.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.Makes:- Legrand(Myrius),L&T(Oris),Anchor Roma(Plus)
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-Makes:- L&T/Legrand/Schneider.
Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- L&T/Legrand/Schneider.
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Makes:- L&T/Legrand/Schneider.
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-6 way
Double door-12 way
Double door-16 way
Makes:- L&T/Legrand/Schneider.
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Makes: Usha,Bajaj,Crompton or any other approved make.
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required.
Supplying, Installation, Testing and Commissioning of cubical type, intdoor type,single door,wall mounted, fixed type, free standing single front, dust proof & compartmentalized MainL.T.Panel made out of M.S. CRC Sheet 16G,duly painted with Siemens Grey Powder Coated Paint as per specificationApproximate Size (H)1250MM X (W)1050MM X (D)200MM and Assembly Charges of 125A 4Strip Copper Busbar ( Vertical/Horizontal) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade , Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black andAssembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB /MCCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables and Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. and Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139(EVA or approved Equivalent make).
MATERIAL:
OUTGOING :
MCCB 63A 4P 25kA-02 Nos with O/L & S/C protection- 3 No's,Spreater Terminal MCCB 63A 4P-6Nos.
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Makes for MCCB : Schneider/L&T/ABB .
Supplying, Installation, Testing and Commissioning of cubical type, intdoor type,single door,wall mounted, fixed type, free standing single front, dust proof & compartmentalized MainL.T.Panel made out of M.S. CRC Sheet 16G,duly painted with Siemens Grey Powder Coated Paint as per specificationApproximate Size (H)650MM X (W)450MM X (D)200MM and Assembly Charges of 63A 4Strip Copper Busbar ( Vertical/Horizontal) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade , Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black andAssembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB /MCCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables and Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. and Assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139(EVA or approved Equivalent make).
MATERIAL:
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc,
Makes for MCCB : Schneider/L&T/ABB .
Providing and fixing surface mounted Square/Round downlighter with die cast Al housing in white powder coated finish, anti glare diffuser and and energy efficient electronic driver ,suitable for surface application with the use of the latest technology 20 watt (2000 Lumen) 4000K and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Surface mounting Square/Round downlighter 20 watt
Makes:- Panasonic (Cat No PDLM10204BS),Bajaj,Wipro,Philips or any other approved make.
Providing, Installation, testing and commissioning of ceiling fan with two module modular step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep, Category-A
Makes:-Usha Technix Plus 3 Star Rating, Bajaj,Crompton, or any other approvred make.
Providing and fixing indoor decorative aluminium extruded LED Batten including tube rod 18 watt and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
Batten for T8 Tube Light with tube rod
Makes:- Bajaj (Cat. No. BLRB DB 118 ),Tube rod(Cat. No.BLRB 18W CWi) ,Panasonic or any approved make
Providing and fixing LED Bulk head of following rating made of aluminium housing and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Bulk head fitting 10 watt
Makes: Philips,Panasonic(Cat No.-PBHM01107),Bajaj ,Wipro or any other approved by Engineer-in-Charge.
Sourab Kuthiala
M/s Jamwal nxt gen energy solutions
KISHORI LAL SHARMA GOVT. CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .