Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.2 LAccepted-AOC 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.0 L+₹4.7 L (13.4%)Rejected-AOC 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | L2 | Rejected-AOC L2 | |
| 3 | L3₹46.9 L+₹11.6 L (32.9%)Rejected-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L3 | Rejected-AOC L3 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
31 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
PROVISION OF VOLTAGE STABILIZER AND CONNECTED WORKS IN NCN AT TS K ALWAYE AND PROVISION OF 02 NUMBER OF 2 KV UPS SINGLE PHASE FOR 04 MOTOROLA REPEATER AT 7TH FLOOR OF INHS SANJIVANI LIFT ROOM.
2023_MES_627166_2
8311/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
ALWAYE
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NS KOCHI
₹75,000
Yes
6 Apr 2024
12 Jan 2024
3 Feb 2024
12 Jan 2024
31 Jan 2024
13 Jan 2024
Amount
Surface excavation not exceeding 30cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and as directed by Engineer in Charge.
Excavation in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in dense or soft soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundation, etc, or for shafts, wells, cesspits, manholes, pier holes, etc, not exceeding 10 sqm on plan and not exceeding 1.5 metre in depth and getting out as in hard dense /soil complete all as specified
Material & Labour for Cement concrete type B2 type 1:2:4 (40 mm graded aggregate)in foundations, filling and mass concrete post holes filling etc complete all as specified and as directed by Engineer in Charge.
Supply & Fix Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161- 1979 grade St-240 complete all as specified and as directed by Engineer in Charge.
Supply & Fix Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self Tapping screws as specified complete all as specified and as directed by Engineer in Charge.
Supply & Fix Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self Tapping screws as specified complete all as specified and as directed by Engineer in Charge.
Supply & Fix Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk, for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets, complete all as specified and as directed by Engineer in Charge.
Material & Labour for Pre-cast cement concrete block masonry type C1 1:3:6 (20mm graded aggregate) with solid blocks, exceeding 10 cm in width and setting in mortar 1:6, complete all as specified and as directed by Engineer in Charge.
Material & Labour for forming embankments including raising earth, spreading in layers not exceeding 30cm thick, watering, ramming/rolling and finishing to required size, shape, etc. not exceeding 1.5 metre high from base work or concrete surfaces in CM 1:4 complete all as specified and as directed by Engineer in Charge.
Material & Labour for hardcore of gauge broken stone or boulders not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and as directed by Engineer in Charge
Material & Labour for 100mm thick PCC type C-2 1:3:6, (40mm graded aggregate) as in sub base, floor finishing etc, complete all as specified and as directed
Material & Labour for cement concrete 50mm thick type B-1, 1:2:4 (20mm graded aggregate) sub base, floorings, paving etc including finishing with even and smooth without using extra cement complete all as specified and as directed by Engineer in Charge
Material & Labour for Moorum/red bajri filling in floors or paving, laid in layers not exceeding 15 cm thick, spread, leveled and rammed including watering complete all as directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as directed
Material & Labour for preparation of new steel surfaces over 10 cm width or girth and treating surface with two coats of black bituminous paint over the priming coat of red oxide complete all as specified and directed
Material & Labour for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Material & Labour for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gram/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
Removing excavated materials in soils etc exceeding 250metre but not exceeding 500metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for soling (or sub base) 150 mm thick (spread thickness) in one layer with broken boulders or quarried stone, interstices filled, surface formed and rolled using power roller 8 to 12 tonne capacity and consolidated to required gradient and camber etc, complete all as specified and as directed
Material & Labour for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed.
Material & Labour for filling 12.5mm aggregate for cushioning of paver tiles with spreading and leveling as required complete all as specified and as directed
Material & Labour for Machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 80mm thick M-40 grade etc complete (with grey cement and no pigment) over sand cushioning complete all as specified and as directed.
Material & Labour for providing cement concrete type B1 1:2:4 (20mm graded aggregate) as in coping,bed plates of hold fast rounded or chamfered on edges, curb including all formwork etc complete all as specified and directed.
Excavation in trenches in Soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5metre in depth for foundation, laying of pipes, cables, etc, or for shafts, wells, cesspits, manholes, pier holes, etc, not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
Supply and spread M Sand for cushioning and covering of UG cables in trenches complete all specified and directed. (Note : For measurement purpose only punned thickness shall be measured and paid)
Supply and laying un-reinforced precast concrete cable cover class LV type-I flat size 250mm x 150mm x 40mm complete all specified and directed.
Supply & laying in replacement Galvanised steel tubing of size 80 mm bore, light grade to be fixed on walls or laid under roads for passing cables complete all specified and directed.
Supply and Laying UG cable in trenches/passing through pipes/fixed on walls or poles cable XLPE insulated, screened, PVC bedded, steel strip or wire armoured electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 3.5 core 300 Sqmm with suitable cable gland complete all as specified and directed.
Supply and fix Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled (including filling of initial oil), indoor type & designed for input variation between 269 to 465 Volt with output voltage stabilized at 415 Volts of capacity 400 KVA as per following:- (a) Servo Voltage Stabilizer shall be confirming to 9815 (Part -1) 1994 (Second revision) (Reaffirmed 2019). The performance requirement should be as per Para 9 of the BIS 9815 (Part - 1) (Reaffirmed 2019) which is reproduced as under :- (i) The corrector shall keep the output voltage within + 1% of the rated voltage irrespective of load and input voltage range, as per clause 9.1 of BIS. (ii) Speed of Correction: - The rate of correction of voltage shall not be less than 6 Volt per second between phase and neutral. The corrector shall be free from hunting during automatic operation, as clause 9.3 & 9.4 of BIS. (iii) Losses: - The manufacturer shall state the no load and full load losses corresponding to minimum and maximum rated input voltages. The tolerances on these declared values shall be provided in table 7 of IS 2026 (Part- I): 1977. The no load current shall not be more than 5% of the rated output current, as clause 9.3 & 9.4 of BIS. (iv) Efficiency: - The efficiency of servo voltage stabilizer shall be not less than 95%, as per clause 9.6 of BIS.
(b) Acceptance tests: The testing of servo voltage stabilizer should be carried out in accordance with Para 11.2 of the BIS 9815 (Part- 1) (Reaffirmed 2004) The following shall constitute acceptance tests :- (i) Physical examination. (ii) Insulation resistance. (iii) High voltage test. (iv) Leakage current test. (v) Provision for earthing. (vi) Output voltage. (vii) No load current. (viii) Measurement of no load losses (ix) Induced voltage test. (c) Test repot as per clause 11.1 for any rating as per clause 5.1 of BIS 9815 (Part - 1) should be obtained from manufacturer for the specified capacity/next higher capacity of any voltage range from govt. Lab/NABL accredited Lab and to be submitted by the contractor.
Material & Labour for Earthing complete with copper earth plate electrode 600x600x3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip 20x3 mm dia, soldered and riveted to earth plate. Earth strip will be protected by using 40mm dia bore GI pipe light grade. The earthing includes PCC Pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metres etc complete all as shown in electrical plate No. 3 of SSR Part-I 2009, connected to earthing test point all as specified or indicated including testing on completion.
Supply, install & Commissioning of 2 Kw UPS stand-alone configuration, single phase in and out (IP20) input PF 0.99, it shall be 100% generator compactible, with efficiency> 83% and output power factor unity (2Kva=2Kw) including all accessories etc., as required. The acoustic noise at 1metre of the system should be <55 db. The system shall be complied IEC/EN 62040-1,2,3 and relevant IS standard along, the system shall be true online double conversion DSP based UPS system and UPS shall be with automatic & manual bypass switch. The system shall have IGBT rectifier and inverter including rack and interconnecting cable and 30 minutes back up SMF battery of reputed approved make for above configuration 12V 26 Ah 6 no’s complete all as specified and directed.
Material and labour for point wiring using approved colour coding as per IS (Red, black & green for single phase circuits) with FRLSH 1.5 Sqmm size PVC single core unsheathed copper conductor multistranded cables drawn through and including PVC casing & caping of suitable size and all accessories, fire resistant, ISI Marked including concealed modular terminal box (recessed) with top cover including PVC single core unsheathed copper conductor multistranded cables FRLSH 1.5 Sqmm as earth continuity conductor for 5 pin 5 Amps switch socket outlet point on independent board complete all as specified and directed
Supply and fix Switch Socket combination, 5A - 5 pin 2 in 1 complete all as specified and directed.
Material and labour for sub main wiring with 2 runs of 6 Sqmm PVC insulated unsheathed single core multi stranded copper conductor cable, FRLS, ISI marked and one run of 4 Sqmm multi stranded insulated copper conductor cable, FRLS, ISI marked as earth continuity conductor drawn through and including PVC casing & caping of suitable size and all accessories, not less than 2mm thick, fire resistant, ISI marked and making good the disturbed surfaces of walls / floors / ceiling etc and complete all as specified and directed. Note: 3 run of cable and one run of PVC casing & caping shall be measured as one Unit.
Material and Labour for second class hardwood in in scantlings framed and fixed complete all as specified and directed.
Material and Labour for 2nd class hardwood supplied and fixed with nails in any situation bracket (except flooring and skirtings) clean swan with butt joint of thickness 25 mm fixed in shells, partitions and shells of built-in cupboard, almirahs, book cases, toilet boxes, racks, pelmet and similar work complete all as specified and directed.
Supply & fixing mild steel round bar of FE-410, 10mm dia and over, cut to length, bend to shape, required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Excavation in over areas not exceeding 1.5 deep and getting out in hard dense soil complete all as specified and directed.
Material labour for Cement concrete type D-2 1:4:8 (40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.
Material and Labour for rendering 10 mm thick own fair faces of brick work or concrete surfaces with 1:4 complete all as specified and directed.
Material labour for three coats of white washing on walls complete all as specified and directed.
Supply and fixing FE-410 W roof trusses (framed) trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, Tee, angle, channel or flat section) including distance pieces cleats etc. complete all as specified and directed.
Material labour for wooden surfaces of any description over 10 cm in width or girth not otherwise described, applying two coats of synthetic paint over one coats of pink primer complete all as specified and as directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
P K ENTERPRISES
ELAN ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .